Drinking Water Supply and Sanitation Government Departments Closing in 41 days TDR #57361888

Tender For Work Of Narmada Based Water Supply Project For 163 Villages Of Dhorimanna And Chouhtan Block, Distt. Barmer (Package Cp-03, Chouhtan-1 Under Jica Funded Rajasthan Rural Water Supply And Fluorosis Mitigation Project Phase Ii On Spr Basis With On

Issued by Government Departments · Barmer, Rajasthan
Tender Value
Ref. Documents
Estimated cost
Bid Submission
26 Oct 2026
41 days left
EMD
13.15 Crore
Bank guarantee accepted
Document Fee
50000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Barmer → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Work Of Narmada Based Water Supply Project For 163 Villages Of Dhorimanna And Chouhtan Block, Distt. Barmer (Package Cp-03, Chouhtan-1 Under Jica Funded Rajasthan Rural Water Supply And Fluorosis Mitigation Project Phase Ii On Spr Basis With One-Year

BOQ

Name of Work:- Work of Narmada Based Water Supply Project for 163 Villages of Dhorimanna and Chouhtan Block, Distt. Barmer (Package CP-03, Chouhtan-1 under JICA funded Rajasthan Rural Water Supply & Fluorosis Mitigation Project Phase II on SPR basis with one-year Defect Notification period & 10 years O&M. (CP-03)
Sl. No. Item Description
1BILL 1 - WATER TREATMENT PLANT
2Survey, Design, Construction, Testing and Commissioning of Rapid Gravity Water Treatment Plant (Output Capacity 58 MLD or 2636.365 KL/Hr.) including all relevant Civil, Electrical, Mechanical, Instrumentation, Automisation, SCADA Works along with Ancillary Civil Works as per specifications and Employer's requirement complete in all respect. at ALETI HW. (Instrumentation, Automisation and SCADA works shall be paid as per Section for Instrumentation, Outdoor Switchyard as per Section for Electrical).
3Inlet and Distribution System:Inlet chamber, Measuring channel, Flash Mixers, Main/ By Pass Channel to Filter Beds, Walkways, Stairs, Railings etc.
4Equipments
5Civil works
6Clariflocculator:Pipes between Flash Mixers and Clariflocculator, Clariflocculator, Walkways, Stairs, Railings, Clarified Water Channel to the Filter Inlet Channel and Sludge Pipe to Sludge Buffer Tanks etc.
7Equipments
8Civil works
9Filters and Filter House:Filters, Distribution/ Back Wash Channel, Pipe Gallery with Clear Water Channel and Sump, Control Gallery, observation Platforms, Walkways, Stairs, Railings, Back Wash Water Tank, Clear WaterMeasuring Channel, and any other item required for completion of filter plant other than specified in BOQ.
10Equipments
11Civil works
12Administrative and Control Building:Administrative Control Building, Backwash Pumps, Air Blowers, Laboratory Equipment, Water Cooler, Furniture etc. as per Scope of Work and Specifications
13Equipments
14Civil works
15Chemical House:Chemical House, Alum/PAC and Lime Dosing Equipment, Piping to the Injection Point and Injection Devices
16Equipments
17Civil works
18Chlorine Building, Chlorination and Chlorine Storage: Chlorine Storage Area, Chlorine Building, Chlorine Toners, Chlorination Equipments, Chlorination Chamber, Injection Devices etc
19Equipments
20Civil works
21Backwash Water and Sludge Recycling and Disposal: Construction of Water Recirculation System including associated work of Inlet/Outlet, Recycling of Backwash Water and SludgeHandling and Disposal System, Pumps and Piping etc.
22Equipments
23Civil works
24BILL-2 - PIPELINE WORKS
25Earth work in Excavation in all kind of Strata (all type of Soil/ soft rock/ hard rock etc), including Road Cutting in all type of road (RCC/Cement Concrete / bitumen road/stone pitching road /gravel road etc) and including road restoration in all type of road (RCC/Cement Concrete / bitumen road/stone pitching road /gravel road etc), Sand/Soil Bedding in rocky starta or wherever required, disposal of surplus excavated Earth for the Trench, Road Cuttings/Crossing (other than pushin) & Road restoration , River/ Drain and Canal/Gas/Petroleum Pipelines Crossing (other than pushin), Construction of RCC - Pedestals, Anchor/Thrust/Fixidity Blocks, Cross walls, Protective Aprons, Encasing, other Civil Works etc as per specifications and Employer requirement for following diameter Pipe Line:-
26100 mm
27110mm
28125mm
29140mm
30150 mm
31160 mm
32180mm
33200 mm
34225mm
35250 mm
36300 mm
37350 mm
38450 mm
39500 mm
40700 mm
41900 mm
421200 mm
43Survey, Design, Supply, Laying, Jointing, Testing and Commissioning of ISI marked S/S DI (Ductile Iron) K7 Class Pipe as per IS:8329-2000 (Amended up to date) for Raw / Clear Water Transmission, ESR/ GSR Rising Main, Cluster/ Village Distribution including Flanged Pipes wherever required, Socket/ Flanged Specials and Isolations and Interconnection works with existing system where dovetailing is required. This work also includes the required Laying above the Ground Level, Crossing required for Drain, Canal, River and Road crossings with Reinstatement Works, following diameters of Pipe Lines as per Employer requirement and Specification. (Payment for Casing Pipe to Cross National/ State/ Mega Highway/ GREF Road shall be made as per separate item. However, MS / DI DF / Fitting for other to this shall be paid in this section).
44100 mm dia
45150 mm dia
46200 mm dia
47250 mm dia
48300 mm dia
49350 mm dia
50450 mm dia
51500 mm dia
52700 mm dia
53900 mm dia
54Survey, Design, Supply, Laying, Jointing, Testing and Commissioning of ISI marked S/S DI (Ductile Iron) K9 Class Pipe as per IS:8329-2000 (Amended up to date) for Raw / Clear Water Transmission, ESR/ GSR Rising Main, Cluster/ Village Distribution including Flanged Pipes wherever required, Socket/ Flanged Specials and Isolations and Interconnection works with existing system where dovetailing is required. This work also includes the required Laying above the Ground Level, Crossing required for Drain, Canal, River and Road crossings with Reinstatement Works, following diameters of Pipe Lines as per Employer requirement and Specification. (Payment for Casing Pipe to Cross National/ State/ Mega Highway/ GREF Road shall be made as per separate item. However, MS / DI DF / Fitting for other to this shall be paid in this section).
55100 mm dia
56150 mm dia
57200 mm dia
58250 mm dia
59Survey, Design, Supply, Laying, Jointing, Testing and Commissioning in position to correct line spirally welded MS/SAW/Fabricated Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for thickness (as per approved design) and inside dia Mtr, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge; Providing and applying following Coating to the External surface of MS pipes, including preparation of surface by cleaning as per ISO 8502-3/ SSPC-SP10/ NACE No.2 near white blast cleaning and abrasive blasting to a finish to SA 2.5 as per ISO: 8501-1 and surface profile / anchor profile of 50-75 / 75-100 microns as per ISO: 8503- 2, including field joint coating at site complete as per Technical specifications and direction of Engineer –in-charge: 3 LPE (3 Layer Polyethylene) / DFBE (Dual Layer Fusion Bonded Epoxy)/ PU (Polyurethane)/ Polyolefin Tape coating . Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/ WARS approved for drinking water. Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately.
60100 mm dia confirming to IS 3589-2001 or its latest revision/ amendments
61125 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
62150 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
63200 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
64250 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
65300 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
66350 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
67450 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
68500 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
69Outer Dia. 711 mm & 06.30 mm min. thickness confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed
70Outer Dia. 914 mm & 08 mm min. thickness confirming to IS 3589- 2001 or its latest revision/ amendments/reaffirmed
71Outer Dia. 1219 mm & 10 mm min. thickness confirming to IS 3589- 2001 or its latest revision/ amendments/ reaffirmed
72Providing, erction and commissioning of Cathodic protection for the buried portion of 900 mm & 1200 mm MS pipeline including cost of rubber gaskets etc. required for cathodic protection seperation, if any, construction of terminals etc. as per specification
73900 mm dia
741200 mm dia
75Survey, Design, Supply, Lying and Pushing of MS Casing Pipe as per approved design & drawing of concern Department Authority/EIC ( for following carrier pipe dia.) of specified thickness (thikness as per approved drawing & design) including all type of required size of casing pipe , Sluice Valves/other Valves at U/S and D/S and jointing/supporting materials with valve chamber etc civil work approved by concerned Department Authority/EIC by Trenchless Method adopting any suitable Technology Below Ground at required depth under Running Traffic Condition as per NH/SH/GREF/MEGA Highway Standard/GREF road/Canal Crossing, including Excavation of Driven Pits and Exit Pit with proper Protection, Construction of Temporary Works etc. as per approved by concern Authority Specification as per Employer's Requirement Specification for following Carrier Pipe diameter (Carrier Pipe shall be measured in Pipe Line Length in separate item) including all type of Excavation of boring pit & receiving pit provide Thrust Wall / Bed as required boring, jacking of MS pipe in embankment for crossing as per approved design & drawing - For all soil strata (for Canal/road etc Crossing ) by trenchless technology
76MS Casing Pipe required for carrier pipe of 100 mm dia
77MS Casing Pipe required for carrier pipe of 125 mm dia
78MS Casing Pipe required for carrier pipe of 150 mm dia
79MS Casing Pipe required for carrier pipe of 200 mm dia
80MS Casing Pipe required for carrier pipe of 250 mm dia
81MS Casing Pipe required for carrier pipe of 300 mm dia
82MS Casing Pipe required for carrier pipe of 350 mm dia
83MS Casing Pipe required for carrier pipe of 450 mm dia
84MS Casing Pipe required for carrier pipe of 500 mm dia
85MS Casing Pipe required for carrier pipe of 700 mm dia
86MS Casing Pipe required for carrier pipe of 900 mm dia
87MS Casing Pipe required for carrier pipe of 1200 mm dia
88Survey, Design, Supply, Laying, Aligning, Fixing in position, Jointing, Testing, Commissioning of ISI marked HDPE Pipes of Class PE 80, PN-6 suitable for Potable Water as per IS 4984:1995 (Amended up to date) with Specials and necessary Jointing Material like Mechanical Connectors i.e. Thread / Insert Joint / Quick Release Coupler Joint /Compression Fitting Joint or Flanged Joint and Special Jointing Pipe by Butt Fusion / Electro Fusion Welding method, Flanged Joints shall be used for Jointing HDPE Pipes to Valves and Non-HDPE Pipes. This work also includes the Drain/ Canal/ River/ Road Crossings with Reinstatement works for following outer diameters of Pipe Lines as per Employer's Requirement and Specification: (Payment for Casing Pipe to Cross National/State/Mega Highway/GREF Road shall be made as per seperate item. However MS / DI DF / Fitting for other to this shall be measured in this section).-
89110mm
90125mm
91140mm
92160mm
93180mm
94200mm
95225mm
96Supply, Installation, Testing and Commissioning of following diameter PN 1.0 Rating Tamper Proof CI Single Air valve including construction of RCC Air Valve Shaft (height 3.0m above ground level) complete work on DI/HDPE Pipe Lines as per Employer's Requirement and Specification -
9725 mm
98Supply, installation, Testing and Commissioning of following diameter PN 1.6 Rating DI Kinetic type temper proof Double orifice Air Valve with Isolation Valves including construction of RCC Air Valve Shaft (height 3.0m above ground level) complete work on DI/HDPE Pipe Lines as per Employer's Requirement andSpecification -
99100mm
100150mm
101Supply, installation, Testing, Commissioning and Jointing in pipe line, combination Air Release Valve Kinetic type with single chamber housed Double orifice and have 3 functions, large Air exhaust, small Air venting and large air intake during vacuum of pipeline of approved makes of following pressure rating and dia and as per following specifications: Governing standard- AWWA C512, Body and bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float & internal trim: AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR Drilled as per IS:1538. Electrostatic Epoxy Powder (EP- P)/ Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside Fasteners- CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, Big orifice size should be equal or larger than the inlet flange bore, for fully comply with AWWA C512), Valve including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.
102150 mm dia (PN 1.6 )
103Supply, Installation, Testing and Commissioning of following diameter PN 1.0 Rating CI Scour Valves with Dismantling Joints, Fittings and Specials, complete work at all required locations per Employer's Requirement and Specification :-
104100mm
105Supply, Installation, Testing and Commissioning of following diameter PN 1.6 Rating CI Scour Valves (with Gear Arrangement if required) with Dismantling Joints, Fittings and Specials, complete work at all required locations as per Employer's Requirement and Specification:-
106100mm
107150 mm
108200 mm
109250 mm
110300 mm
111Supply, Installation, Testing and Commissioning of following diameter PN 1.0/1.6 Rating D/F CI Sluice Valves (with Gear Arrangement if required) with Dismantling Joints, Fittings and Specials, complete work at all required locations per Employer'sRequirement and Specification:-
112100 mm dia
113150 mm dia
114200 mm dia
115250 mm dia
116300 mm dia
117Supply, Installation, Testing and Commissioning of following diameter suitable Rating DI Soft Seated Sluice Valves (with Gear Arrangement if required) for Off takes/Junctions, Sectionalising, outside of pump house and at upstream of FCV to Pipe Line, including in-village pipelines as per Employer's Requirement and Specification :-
118Manually Operated Resilient Seated Sluice Valves of Class PN 1.6
119100mm
120125mm
121150mm
122200mm
123250mm
124300mm
125350mm
126400mm
127450mm
128500mm
129600 mm
130700 mm
131800 mm
132900 mm
1331000 mm
1341100 mm
135Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6
136100 mm dia
137125 mm dia
138150 mm dia
139200 mm dia
140350 mm dia
141400 mm dia
142500 mm dia
143600 mm dia
144700 mm dia
145900 mm dia
1461000 mm dia
1471200 mm dia
148Supply, Installation, Testing and Commissioning of following diameter suitable Rating DI Soft Seated Butterfly Valves for Sectionalising to Pipe Line as per Employer's Requirement and Specification :-
149Class PN 1.6 Manually Operated with Gear
1501200mm
151Class PN 1.6 Motorised Operated
152700 mm dia
153900 mm dia
1541000 mm dia
1551200 mm dia
156Supply, Installation, Testing and Commissioning of following diameter suitable Rating Plungar Type Flow and Pressure Control Valves along as per Employer's Requirement and Specification :-
157150mm
158Carrying out Surge Analysis, Construction, Supply, Installation, Testing and Commissioning of suitable Surge Controlled Devices as approved with all Piping, Valves, Accessories for the Transmission and Rising/ Pumping Mains complete as per Employer's Requirement and Specifications :-
159Transmission Main
160Raw Water Transmission Main from RD 74 Km RWPS TO Aleti H/W
161RWR TO WTP
162ALETI HEAD WORKS to IPS BAMARALA
163IPS BAMARALA to IPS PHAGALIYA
164IPS BAMARALA to IPS SOBHALA DARSHAN
165IPS PHAGALIYA to CPS FAKIRON KA NIWAN
166IPS PHAGALIYA to CPS SATA
167IPS SOBHALA DARSHAN to IPS DHANAOO
168IPS SOBHALA DARSHAN to CPS SERWA
169ESRs Rising Main from
170Aleti HEAD WORKS
171IPS BAMARALA
172IPS PHAGALIYA
173CPS SATA
174CPS FAKIRON KA NIWAN
175CPS SERWA
176IPS SOBHALA DARSHAN
177Survey, Design, Construction of RCC valve chambers for Sectionalizing valves, offtake/junction valves, flow meters(FM+DJ) and (FM+DJ+SV), complete work at all required locations. This also includes excavation in all type of Strata with all lift, refilling of earth, disposal of excess earth materials for following pipe sizes as per employer's requirement and Specification :-
178up to 125 mm (Minimum size 1.13mx0.85m)
179above 125 mm & up to 200mm (Minimum size 1.17mx0.95m)
180above 200 to 300mm (Minimum size 1.26mx1.185m)
181350 to 450mm (Minimum size 1.39mx1.43m)
182500 to 700mm (Minimum size 1.61mx1.75m)
183750 to 1200mm (Minimum size 2.10mx2.30m)
184Survey, Design, Construction of RCC chambers for Scour valves, supports, complete work at all required locations. This also includes end excavation in all type of Strata with all lift, refilling of earth, disposal of excess earth materials for the following Valve sizes as per employer's requirement and Specification :-
18580/100 mm dia (Minimum size 1.13mx0.85m)
186Survey, Design, Construction of RCC chambers for SV+DJ+FCV+FM+DJ, within campus, supports, complete work at all required locations. This also includes end excavation in all type of Strata with all lift, refilling of earth, disposal of excess earth materials the following Valve sizes as per employer's requirement and Specification :-
187up to 250mm (Minimum size 3.0mx1.5m)
188BILL-3 - RESERVOIR WORKS
189Surveying, Geotechnical Investigations, Designing and construction of Raw water Reservoir, earth work, Double PCC Block Lining work, HDPE film work, Ramp, inlet sump, inlet/delivery well, including the works related to inlet arrangements delivery well, making interconnection, Bituminous Road work all around the RWR; with all finishing work to complete the structure in all respect etc. as per attached drawing, scope of work, specification and as per direction of Engineer-in-charge complete in all respect at Aleti HW. (As per approved Drawing & Design from MNIT Jaipur/MBM Engineering college Jodhpur or any Indian Institute of Technology Govt. of India.)
1901420 ML capacity
191Survey, Design, Construction, Testing, commissioning of circular RCC Clear Water reservoirs including CI/DI puddle collars for inlet, one/two outlets, overflow and washout. It also includes Providing and fixing double flanged ISI marked DI class K- 9 pipes {as per IS:8329-2000 (amended upto date), as cortical pipes for RCC reservoirs including specials required such as duckfoot bend, bend tee etc. Providing clamps at every 3 MTR, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. Complete in all respect upto and form valve chamber as per direction of EIC, technical specification and scope of work} for inlet, outlet, overflow and washout along with ductfoot bends, DI soft seated Valves along with Dismantling Joints on inlet, outlet and washout pipes with sluice valves (both of these piping upto the chamber where these will join storm water drain pipe), construction of chamber to join overflow+washout with storm water drain pipe complete in all respect at following locations:-
192CPS Sata (800 KL)
193CPS Fakhiron ka Niwan (700 KL)
194CPS Serwa(500 KL)
195CPS Aleti HW (5750 KL)
196IPS Bamarla (5600 KL)
197IPS Phagaliya (1400 KL)
198IPS Dhanoo (3200 KL)
199IPS Shobhala Darshan (3700 KL) Please Enable Macros to View BoQ information
200IPS Shobhala Darshan (3700 KL) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57361888
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 26-10-2026
Authority
Authority Name public health engineering department
Work Description Tender For Work Of Narmada Based Water Supply Project For 163 Villages Of Dhorimanna And Chouhtan Block, Distt. Barmer (Package Cp-03, Chouhtan-1 Under Jica Funded Rajasthan Rural Water Supply And Fluorosis Mitigation Project Phase Ii On Spr Basis With One-Year
Basic Detail
Tender No IFB 01/2026-27
Bidding Type Tender
Location
City Barmer
State Rajasthan
Key Dates
Publish Date 04 Sep 2026
Submission Date 26 Oct 2026
Open Date 26 Oct 2026
Finance
Tender Value Ref. Documents
Tender Fee 50000
EMD 13.15 Crore
Exemption Available
Document List
174c0116-d4ad-496f-8098-d8f7839ae9e9.html
BOQ_1055254.xls
Tendernotice_1 (72).pdf
VOLUME-I.pdf
VOLUME-II.pdf
VOLUME-III.pdf
VOLUME-IV.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 26, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 41 days
Oct 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 41 days

Tender Documents

Download All (ZIP) ↓
html

174c0116-d4ad-496f-8098-d8f7839ae9e9.html

xls

BOQ_1055254.xls

pdf

Tendernotice_1 (72).pdf

pdf

VOLUME-I.pdf

pdf

VOLUME-II.pdf

pdf

VOLUME-III.pdf

pdf

VOLUME-IV.pdf

Disclaimer