Tender For Work Of Narmada Based Water Supply Project For 163 Villages Of Dhorimanna And Chouhtan Block, Distt. Barmer (Package Cp-03, Chouhtan-1 Under Jica Funded Rajasthan Rural Water Supply And Fluorosis Mitigation Project Phase Ii On Spr Basis With On
Tender Overview
Project Description
Tender For Work Of Narmada Based Water Supply Project For 163 Villages Of Dhorimanna And Chouhtan Block, Distt. Barmer (Package Cp-03, Chouhtan-1 Under Jica Funded Rajasthan Rural Water Supply And Fluorosis Mitigation Project Phase Ii On Spr Basis With One-Year
BOQ
| Sl. No. | Item Description |
| 1 | BILL 1 - WATER TREATMENT PLANT |
| 2 | Survey, Design, Construction, Testing and Commissioning of Rapid Gravity Water Treatment Plant (Output Capacity 58 MLD or 2636.365 KL/Hr.) including all relevant Civil, Electrical, Mechanical, Instrumentation, Automisation, SCADA Works along with Ancillary Civil Works as per specifications and Employer's requirement complete in all respect. at ALETI HW. (Instrumentation, Automisation and SCADA works shall be paid as per Section for Instrumentation, Outdoor Switchyard as per Section for Electrical). |
| 3 | Inlet and Distribution System:Inlet chamber, Measuring channel, Flash Mixers, Main/ By Pass Channel to Filter Beds, Walkways, Stairs, Railings etc. |
| 4 | Equipments |
| 5 | Civil works |
| 6 | Clariflocculator:Pipes between Flash Mixers and Clariflocculator, Clariflocculator, Walkways, Stairs, Railings, Clarified Water Channel to the Filter Inlet Channel and Sludge Pipe to Sludge Buffer Tanks etc. |
| 7 | Equipments |
| 8 | Civil works |
| 9 | Filters and Filter House:Filters, Distribution/ Back Wash Channel, Pipe Gallery with Clear Water Channel and Sump, Control Gallery, observation Platforms, Walkways, Stairs, Railings, Back Wash Water Tank, Clear WaterMeasuring Channel, and any other item required for completion of filter plant other than specified in BOQ. |
| 10 | Equipments |
| 11 | Civil works |
| 12 | Administrative and Control Building:Administrative Control Building, Backwash Pumps, Air Blowers, Laboratory Equipment, Water Cooler, Furniture etc. as per Scope of Work and Specifications |
| 13 | Equipments |
| 14 | Civil works |
| 15 | Chemical House:Chemical House, Alum/PAC and Lime Dosing Equipment, Piping to the Injection Point and Injection Devices |
| 16 | Equipments |
| 17 | Civil works |
| 18 | Chlorine Building, Chlorination and Chlorine Storage: Chlorine Storage Area, Chlorine Building, Chlorine Toners, Chlorination Equipments, Chlorination Chamber, Injection Devices etc |
| 19 | Equipments |
| 20 | Civil works |
| 21 | Backwash Water and Sludge Recycling and Disposal: Construction of Water Recirculation System including associated work of Inlet/Outlet, Recycling of Backwash Water and SludgeHandling and Disposal System, Pumps and Piping etc. |
| 22 | Equipments |
| 23 | Civil works |
| 24 | BILL-2 - PIPELINE WORKS |
| 25 | Earth work in Excavation in all kind of Strata (all type of Soil/ soft rock/ hard rock etc), including Road Cutting in all type of road (RCC/Cement Concrete / bitumen road/stone pitching road /gravel road etc) and including road restoration in all type of road (RCC/Cement Concrete / bitumen road/stone pitching road /gravel road etc), Sand/Soil Bedding in rocky starta or wherever required, disposal of surplus excavated Earth for the Trench, Road Cuttings/Crossing (other than pushin) & Road restoration , River/ Drain and Canal/Gas/Petroleum Pipelines Crossing (other than pushin), Construction of RCC - Pedestals, Anchor/Thrust/Fixidity Blocks, Cross walls, Protective Aprons, Encasing, other Civil Works etc as per specifications and Employer requirement for following diameter Pipe Line:- |
| 26 | 100 mm |
| 27 | 110mm |
| 28 | 125mm |
| 29 | 140mm |
| 30 | 150 mm |
| 31 | 160 mm |
| 32 | 180mm |
| 33 | 200 mm |
| 34 | 225mm |
| 35 | 250 mm |
| 36 | 300 mm |
| 37 | 350 mm |
| 38 | 450 mm |
| 39 | 500 mm |
| 40 | 700 mm |
| 41 | 900 mm |
| 42 | 1200 mm |
| 43 | Survey, Design, Supply, Laying, Jointing, Testing and Commissioning of ISI marked S/S DI (Ductile Iron) K7 Class Pipe as per IS:8329-2000 (Amended up to date) for Raw / Clear Water Transmission, ESR/ GSR Rising Main, Cluster/ Village Distribution including Flanged Pipes wherever required, Socket/ Flanged Specials and Isolations and Interconnection works with existing system where dovetailing is required. This work also includes the required Laying above the Ground Level, Crossing required for Drain, Canal, River and Road crossings with Reinstatement Works, following diameters of Pipe Lines as per Employer requirement and Specification. (Payment for Casing Pipe to Cross National/ State/ Mega Highway/ GREF Road shall be made as per separate item. However, MS / DI DF / Fitting for other to this shall be paid in this section). |
| 44 | 100 mm dia |
| 45 | 150 mm dia |
| 46 | 200 mm dia |
| 47 | 250 mm dia |
| 48 | 300 mm dia |
| 49 | 350 mm dia |
| 50 | 450 mm dia |
| 51 | 500 mm dia |
| 52 | 700 mm dia |
| 53 | 900 mm dia |
| 54 | Survey, Design, Supply, Laying, Jointing, Testing and Commissioning of ISI marked S/S DI (Ductile Iron) K9 Class Pipe as per IS:8329-2000 (Amended up to date) for Raw / Clear Water Transmission, ESR/ GSR Rising Main, Cluster/ Village Distribution including Flanged Pipes wherever required, Socket/ Flanged Specials and Isolations and Interconnection works with existing system where dovetailing is required. This work also includes the required Laying above the Ground Level, Crossing required for Drain, Canal, River and Road crossings with Reinstatement Works, following diameters of Pipe Lines as per Employer requirement and Specification. (Payment for Casing Pipe to Cross National/ State/ Mega Highway/ GREF Road shall be made as per separate item. However, MS / DI DF / Fitting for other to this shall be paid in this section). |
| 55 | 100 mm dia |
| 56 | 150 mm dia |
| 57 | 200 mm dia |
| 58 | 250 mm dia |
| 59 | Survey, Design, Supply, Laying, Jointing, Testing and Commissioning in position to correct line spirally welded MS/SAW/Fabricated Pipe having bevelled end plates / coils, confirming to IS 3589-2001 or its latest revision/ amendments, for thickness (as per approved design) and inside dia Mtr, including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges, including cost of labour and material, specials (Tee, bend etc.), field joints, satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge; Providing and applying following Coating to the External surface of MS pipes, including preparation of surface by cleaning as per ISO 8502-3/ SSPC-SP10/ NACE No.2 near white blast cleaning and abrasive blasting to a finish to SA 2.5 as per ISO: 8501-1 and surface profile / anchor profile of 50-75 / 75-100 microns as per ISO: 8503- 2, including field joint coating at site complete as per Technical specifications and direction of Engineer –in-charge: 3 LPE (3 Layer Polyethylene) / DFBE (Dual Layer Fusion Bonded Epoxy)/ PU (Polyurethane)/ Polyolefin Tape coating . Providing and applying Solvent free, two pack liquid epoxy lining to internal surface of M.S. Pipe as per BS 6920:2000 and AWWA C210 standard including preparation of internal surface of pipe by cleaning and abrasive blasting including field joints coating at site complete as per technical specification and direction of Engineer in Incharge. Liquid Epoxy shall be NSF/ WARS approved for drinking water. Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. |
| 60 | 100 mm dia confirming to IS 3589-2001 or its latest revision/ amendments |
| 61 | 125 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed |
| 62 | 150 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed |
| 63 | 200 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed |
| 64 | 250 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed |
| 65 | 300 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed |
| 66 | 350 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed |
| 67 | 450 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed |
| 68 | 500 mm dia confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed |
| 69 | Outer Dia. 711 mm & 06.30 mm min. thickness confirming to IS 3589-2001 or its latest revision/ amendments/reaffirmed |
| 70 | Outer Dia. 914 mm & 08 mm min. thickness confirming to IS 3589- 2001 or its latest revision/ amendments/reaffirmed |
| 71 | Outer Dia. 1219 mm & 10 mm min. thickness confirming to IS 3589- 2001 or its latest revision/ amendments/ reaffirmed |
| 72 | Providing, erction and commissioning of Cathodic protection for the buried portion of 900 mm & 1200 mm MS pipeline including cost of rubber gaskets etc. required for cathodic protection seperation, if any, construction of terminals etc. as per specification |
| 73 | 900 mm dia |
| 74 | 1200 mm dia |
| 75 | Survey, Design, Supply, Lying and Pushing of MS Casing Pipe as per approved design & drawing of concern Department Authority/EIC ( for following carrier pipe dia.) of specified thickness (thikness as per approved drawing & design) including all type of required size of casing pipe , Sluice Valves/other Valves at U/S and D/S and jointing/supporting materials with valve chamber etc civil work approved by concerned Department Authority/EIC by Trenchless Method adopting any suitable Technology Below Ground at required depth under Running Traffic Condition as per NH/SH/GREF/MEGA Highway Standard/GREF road/Canal Crossing, including Excavation of Driven Pits and Exit Pit with proper Protection, Construction of Temporary Works etc. as per approved by concern Authority Specification as per Employer's Requirement Specification for following Carrier Pipe diameter (Carrier Pipe shall be measured in Pipe Line Length in separate item) including all type of Excavation of boring pit & receiving pit provide Thrust Wall / Bed as required boring, jacking of MS pipe in embankment for crossing as per approved design & drawing - For all soil strata (for Canal/road etc Crossing ) by trenchless technology |
| 76 | MS Casing Pipe required for carrier pipe of 100 mm dia |
| 77 | MS Casing Pipe required for carrier pipe of 125 mm dia |
| 78 | MS Casing Pipe required for carrier pipe of 150 mm dia |
| 79 | MS Casing Pipe required for carrier pipe of 200 mm dia |
| 80 | MS Casing Pipe required for carrier pipe of 250 mm dia |
| 81 | MS Casing Pipe required for carrier pipe of 300 mm dia |
| 82 | MS Casing Pipe required for carrier pipe of 350 mm dia |
| 83 | MS Casing Pipe required for carrier pipe of 450 mm dia |
| 84 | MS Casing Pipe required for carrier pipe of 500 mm dia |
| 85 | MS Casing Pipe required for carrier pipe of 700 mm dia |
| 86 | MS Casing Pipe required for carrier pipe of 900 mm dia |
| 87 | MS Casing Pipe required for carrier pipe of 1200 mm dia |
| 88 | Survey, Design, Supply, Laying, Aligning, Fixing in position, Jointing, Testing, Commissioning of ISI marked HDPE Pipes of Class PE 80, PN-6 suitable for Potable Water as per IS 4984:1995 (Amended up to date) with Specials and necessary Jointing Material like Mechanical Connectors i.e. Thread / Insert Joint / Quick Release Coupler Joint /Compression Fitting Joint or Flanged Joint and Special Jointing Pipe by Butt Fusion / Electro Fusion Welding method, Flanged Joints shall be used for Jointing HDPE Pipes to Valves and Non-HDPE Pipes. This work also includes the Drain/ Canal/ River/ Road Crossings with Reinstatement works for following outer diameters of Pipe Lines as per Employer's Requirement and Specification: (Payment for Casing Pipe to Cross National/State/Mega Highway/GREF Road shall be made as per seperate item. However MS / DI DF / Fitting for other to this shall be measured in this section).- |
| 89 | 110mm |
| 90 | 125mm |
| 91 | 140mm |
| 92 | 160mm |
| 93 | 180mm |
| 94 | 200mm |
| 95 | 225mm |
| 96 | Supply, Installation, Testing and Commissioning of following diameter PN 1.0 Rating Tamper Proof CI Single Air valve including construction of RCC Air Valve Shaft (height 3.0m above ground level) complete work on DI/HDPE Pipe Lines as per Employer's Requirement and Specification - |
| 97 | 25 mm |
| 98 | Supply, installation, Testing and Commissioning of following diameter PN 1.6 Rating DI Kinetic type temper proof Double orifice Air Valve with Isolation Valves including construction of RCC Air Valve Shaft (height 3.0m above ground level) complete work on DI/HDPE Pipe Lines as per Employer's Requirement andSpecification - |
| 99 | 100mm |
| 100 | 150mm |
| 101 | Supply, installation, Testing, Commissioning and Jointing in pipe line, combination Air Release Valve Kinetic type with single chamber housed Double orifice and have 3 functions, large Air exhaust, small Air venting and large air intake during vacuum of pipeline of approved makes of following pressure rating and dia and as per following specifications: Governing standard- AWWA C512, Body and bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865, Float & internal trim: AISI 304 stainless Steel, Seat ring & Gasket - EPDM/NBR Drilled as per IS:1538. Electrostatic Epoxy Powder (EP- P)/ Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body & cover inside and outside Fasteners- CS/ Galvanised steel, Outlet of big orifice will have a screen to prevent Tamper of float, Big orifice size should be equal or larger than the inlet flange bore, for fully comply with AWWA C512), Valve including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge. |
| 102 | 150 mm dia (PN 1.6 ) |
| 103 | Supply, Installation, Testing and Commissioning of following diameter PN 1.0 Rating CI Scour Valves with Dismantling Joints, Fittings and Specials, complete work at all required locations per Employer's Requirement and Specification :- |
| 104 | 100mm |
| 105 | Supply, Installation, Testing and Commissioning of following diameter PN 1.6 Rating CI Scour Valves (with Gear Arrangement if required) with Dismantling Joints, Fittings and Specials, complete work at all required locations as per Employer's Requirement and Specification:- |
| 106 | 100mm |
| 107 | 150 mm |
| 108 | 200 mm |
| 109 | 250 mm |
| 110 | 300 mm |
| 111 | Supply, Installation, Testing and Commissioning of following diameter PN 1.0/1.6 Rating D/F CI Sluice Valves (with Gear Arrangement if required) with Dismantling Joints, Fittings and Specials, complete work at all required locations per Employer'sRequirement and Specification:- |
| 112 | 100 mm dia |
| 113 | 150 mm dia |
| 114 | 200 mm dia |
| 115 | 250 mm dia |
| 116 | 300 mm dia |
| 117 | Supply, Installation, Testing and Commissioning of following diameter suitable Rating DI Soft Seated Sluice Valves (with Gear Arrangement if required) for Off takes/Junctions, Sectionalising, outside of pump house and at upstream of FCV to Pipe Line, including in-village pipelines as per Employer's Requirement and Specification :- |
| 118 | Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 |
| 119 | 100mm |
| 120 | 125mm |
| 121 | 150mm |
| 122 | 200mm |
| 123 | 250mm |
| 124 | 300mm |
| 125 | 350mm |
| 126 | 400mm |
| 127 | 450mm |
| 128 | 500mm |
| 129 | 600 mm |
| 130 | 700 mm |
| 131 | 800 mm |
| 132 | 900 mm |
| 133 | 1000 mm |
| 134 | 1100 mm |
| 135 | Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.6 |
| 136 | 100 mm dia |
| 137 | 125 mm dia |
| 138 | 150 mm dia |
| 139 | 200 mm dia |
| 140 | 350 mm dia |
| 141 | 400 mm dia |
| 142 | 500 mm dia |
| 143 | 600 mm dia |
| 144 | 700 mm dia |
| 145 | 900 mm dia |
| 146 | 1000 mm dia |
| 147 | 1200 mm dia |
| 148 | Supply, Installation, Testing and Commissioning of following diameter suitable Rating DI Soft Seated Butterfly Valves for Sectionalising to Pipe Line as per Employer's Requirement and Specification :- |
| 149 | Class PN 1.6 Manually Operated with Gear |
| 150 | 1200mm |
| 151 | Class PN 1.6 Motorised Operated |
| 152 | 700 mm dia |
| 153 | 900 mm dia |
| 154 | 1000 mm dia |
| 155 | 1200 mm dia |
| 156 | Supply, Installation, Testing and Commissioning of following diameter suitable Rating Plungar Type Flow and Pressure Control Valves along as per Employer's Requirement and Specification :- |
| 157 | 150mm |
| 158 | Carrying out Surge Analysis, Construction, Supply, Installation, Testing and Commissioning of suitable Surge Controlled Devices as approved with all Piping, Valves, Accessories for the Transmission and Rising/ Pumping Mains complete as per Employer's Requirement and Specifications :- |
| 159 | Transmission Main |
| 160 | Raw Water Transmission Main from RD 74 Km RWPS TO Aleti H/W |
| 161 | RWR TO WTP |
| 162 | ALETI HEAD WORKS to IPS BAMARALA |
| 163 | IPS BAMARALA to IPS PHAGALIYA |
| 164 | IPS BAMARALA to IPS SOBHALA DARSHAN |
| 165 | IPS PHAGALIYA to CPS FAKIRON KA NIWAN |
| 166 | IPS PHAGALIYA to CPS SATA |
| 167 | IPS SOBHALA DARSHAN to IPS DHANAOO |
| 168 | IPS SOBHALA DARSHAN to CPS SERWA |
| 169 | ESRs Rising Main from |
| 170 | Aleti HEAD WORKS |
| 171 | IPS BAMARALA |
| 172 | IPS PHAGALIYA |
| 173 | CPS SATA |
| 174 | CPS FAKIRON KA NIWAN |
| 175 | CPS SERWA |
| 176 | IPS SOBHALA DARSHAN |
| 177 | Survey, Design, Construction of RCC valve chambers for Sectionalizing valves, offtake/junction valves, flow meters(FM+DJ) and (FM+DJ+SV), complete work at all required locations. This also includes excavation in all type of Strata with all lift, refilling of earth, disposal of excess earth materials for following pipe sizes as per employer's requirement and Specification :- |
| 178 | up to 125 mm (Minimum size 1.13mx0.85m) |
| 179 | above 125 mm & up to 200mm (Minimum size 1.17mx0.95m) |
| 180 | above 200 to 300mm (Minimum size 1.26mx1.185m) |
| 181 | 350 to 450mm (Minimum size 1.39mx1.43m) |
| 182 | 500 to 700mm (Minimum size 1.61mx1.75m) |
| 183 | 750 to 1200mm (Minimum size 2.10mx2.30m) |
| 184 | Survey, Design, Construction of RCC chambers for Scour valves, supports, complete work at all required locations. This also includes end excavation in all type of Strata with all lift, refilling of earth, disposal of excess earth materials for the following Valve sizes as per employer's requirement and Specification :- |
| 185 | 80/100 mm dia (Minimum size 1.13mx0.85m) |
| 186 | Survey, Design, Construction of RCC chambers for SV+DJ+FCV+FM+DJ, within campus, supports, complete work at all required locations. This also includes end excavation in all type of Strata with all lift, refilling of earth, disposal of excess earth materials the following Valve sizes as per employer's requirement and Specification :- |
| 187 | up to 250mm (Minimum size 3.0mx1.5m) |
| 188 | BILL-3 - RESERVOIR WORKS |
| 189 | Surveying, Geotechnical Investigations, Designing and construction of Raw water Reservoir, earth work, Double PCC Block Lining work, HDPE film work, Ramp, inlet sump, inlet/delivery well, including the works related to inlet arrangements delivery well, making interconnection, Bituminous Road work all around the RWR; with all finishing work to complete the structure in all respect etc. as per attached drawing, scope of work, specification and as per direction of Engineer-in-charge complete in all respect at Aleti HW. (As per approved Drawing & Design from MNIT Jaipur/MBM Engineering college Jodhpur or any Indian Institute of Technology Govt. of India.) |
| 190 | 1420 ML capacity |
| 191 | Survey, Design, Construction, Testing, commissioning of circular RCC Clear Water reservoirs including CI/DI puddle collars for inlet, one/two outlets, overflow and washout. It also includes Providing and fixing double flanged ISI marked DI class K- 9 pipes {as per IS:8329-2000 (amended upto date), as cortical pipes for RCC reservoirs including specials required such as duckfoot bend, bend tee etc. Providing clamps at every 3 MTR, jointing materials such as nuts, bolt, rubber packing, hydraulic testing etc. Complete in all respect upto and form valve chamber as per direction of EIC, technical specification and scope of work} for inlet, outlet, overflow and washout along with ductfoot bends, DI soft seated Valves along with Dismantling Joints on inlet, outlet and washout pipes with sluice valves (both of these piping upto the chamber where these will join storm water drain pipe), construction of chamber to join overflow+washout with storm water drain pipe complete in all respect at following locations:- |
| 192 | CPS Sata (800 KL) |
| 193 | CPS Fakhiron ka Niwan (700 KL) |
| 194 | CPS Serwa(500 KL) |
| 195 | CPS Aleti HW (5750 KL) |
| 196 | IPS Bamarla (5600 KL) |
| 197 | IPS Phagaliya (1400 KL) |
| 198 | IPS Dhanoo (3200 KL) |
| 199 | IPS Shobhala Darshan (3700 KL) Please Enable Macros to View BoQ information |
| 200 | IPS Shobhala Darshan (3700 KL) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 41 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 41 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender