Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Volley Ball Court With Associated Facilities And Addition / Alteration To Indoor Badminton Court And Gymnasium Of Sports Complex In Drdo Township, Phase-Ii, Cv Raman Nagar, Bangalore
BOQ
| Sl. No. | Item Description |
| 1 | Schedule 'A' Part-I (BUILDINGS AND STRUCTURES)This Schedule (contains under mentioned Sl item No. 1.01) is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Col 6. |
| 2 | Construction of \\"Sanitary annexe, sports store & changing room\\" including all fittings and fixtures complete all as specified and as shown on drawings. |
| 3 | Lump sum price worked out by the Contractor for “SITE CLEARANCE\\" as listed in Schedule ‘A’ Part - II representing ______________ % _________________ percent Above / Below the lump sum price of `1,37,266.95 inserted by the MES in Schedule ‘A’ Part - II |
| 4 | Lump sum price worked out by the Contractor for “BADMINTON COURT AND GYMNASIUM” as listed in Schedule ‘A’ Part - III representing __________ % ____________ percent Above / Below the lump sum price of `27,41,738.11 inserted by the MES in Schedule ‘A’ Part - III |
| 5 | Lump sum price worked out by the Contractor for “SEATING ARRANGEMENT” as listed in Schedule ‘A’ Part - IV representing __________ % ____________________ percent Above / Below the lump sum price of ₹14,35,374.20 inserted by the MES in Schedule ‘A’ Part - IV |
| 6 | Lump sum price worked out by the Contractor for “VOLLEY BALL GROUND” as listed in Schedule ‘A’ Part - V representing ________ % ____________ percent Above / Below the lump sum price of ₹4,41,468.86 inserted by the MES in Schedule ‘A’ Part - V |
| 7 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part - VI representing ________ % ____________ percent Above / Below the lump sum price of ₹13,929.15 inserted by the MES in Schedule ‘A’ Part - VI |
| 8 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VII representing _____________ % __________________ percent Above / Below the lump sum price of ₹6,85,145.00 inserted by the MES in Schedule ‘A’ Part - VII |
| 9 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VIII representing ____________ % _____________________ percent Above / Below the lump sum price of `66,173.50 inserted by the MES in Schedule ‘A’ Part - VIII |
| 10 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - IX representing _________ % __________________ percent Above / Below the lump sum price of `5,13,547.00 inserted by the MES in Schedule ‘A’ Part - IX |
| 11 | Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - X representing ____________ % _____________________ percent Above / Below the lump sum price of `46,097.26 inserted by the MES in Schedule ‘A’ Part - X |
| 12 | Lump sum price worked out by the Contractor for “COMPOUND WALL, FENCING AND GATE” as listed in Schedule ‘A’ Part - XI representing __________ % _________________ percent Above / Below the lump sum price of ₹14,55,245.94 inserted by the MES in Schedule ‘A’ Part - XI |
| 13 | Schedule 'A' Part-XIIThis Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 13.00 to 41.00. |
| 14 | SITE CLEARANCEDismantling existing unserviceable concrete pole complete all as specified and directed. |
| 15 | BADMINTON COURT AND GYMNASIUMSupply and installation of USFS FLOOR 21mm SPORTS WOODEN FLOORING BWF STANDARD with 57to 90mm width and in random length in tongue and groove shape, the edges of the boards will have a finger lock groove and the bottom side with air pass groove fixed on pine wood runners of 70mm x 45mm treated with anti-termite solution and fixed on the bottom side with 10mm thick air-cushion pads by staple through the two wings at 350mm c/c an expansion gap of 12 to 15mm will be left open between the wooden flooring and the surrounding tiled area or walls, after installation the floor will be machine sanded in uniform level with water base PU polish complete all as specified and directed. |
| 16 | Supply and installation of BWF approved Sports Synthetic PVC Vinyl Flooring 4.5MM (Crystel Sand Pattern) with installation and Pre-Mark marking. Technical details:- • Surface treatment - PUR coating with UV treatment.• Impact Resistance - DIN 18032 8.• Indentation Resistance - EN 1016 0.50.• Chemical Resistance - Excellent.• Fire Resistance (Grade) - C-s1.• Vertical Deformation - 1.5mm.• Ball Bounce - >90%.• Shock Absorption % >30.• Roll Width - 1.8 Mtr.• Roll Length - 15 Mtr. |
| 17 | (a) M&L for mechanical cleaning of surface to make it free from any bituminous residue / dirt oil and greese all as specified and directed by GE/Engineer-in-Charge.(b) M&L for cracks treatment by cutting open cracks and cleaning it from dirt / loose materials and filling with polyurethane based sealant with and including application of PU based primer all as directed by GE/Engineer-in-Charge. |
| 18 | (c) M&L for applying water based polyurethane modified dispersion (single component, cold applied, non toxic, VOC complaint) in 03 coats including 01 coat of primer of same material after dilution of water at 50% or specific primer matching same material as per manufacturer specification and as directed by GE/EIC. A layer of geotextile grid of minimum 40gsm sandwich in between two PU layers as per manufacturer’s specification be provided.Properties of Polyurethane based chemical shall confirm to following techincal parameters:- |
| 19 | (i) Highly elastic (ii) UV resistance(iii) Adhesion to concrete >1N/Sqmm(iv) Tensile Strength - not less than 2.0 N/Sqmm for free film (v) Elongation - not less than 300%(vi) Solid content by weight - not less than 60%(vii) Air/Water permeability BSEN 12390 at 5 bar - 72 hours should be NIL and minimum dry film thickness of water proofing membrane must be 1.0mm (viii) Accelerated weathering (ASTM 453): Pass 1000 Hours.(ix) Reaction to fire - non inflammable. |
| 20 | Notes:(i) To be applied by the rep of manufacturer’s authorised applicator only. Contractor has to provide manufacturer’s test certificate for the above mentioned technical parameters and purchase voucher.(ii) Removal of existing treatment to be paid separately.(iii) Roof slop to be ensured to avoid water ponding.(iv) For accessible terrace and in-accessible terrace, 300mm height of vertical surface / parapet wall to be treated with same specification of slab. |
| 21 | M&L for interlocking rubber tiles 16mm thick with fabric backing of approved tint (plain colour) of size 50cm x 50cm or more fixing with or without adhesive as per the manufactures instructions laid in floor and skirting complete all as specified and directed. |
| 22 | S&F, looking mirror 600 x 1800mm without frame, but with back supported with 6mm thick AC building board or plywood sheet fixing with necessary fixing arrangement to wall complete all as specified and directed. |
| 23 | VOLLEY BALL GROUNDSupply & apply of USFS floor BWF approved polyurethane sports coating with full Unique Sports PU resins applied on existing concrete for Outdoor Volleyball Court. (i) One layer of Adhesive Primer. (ii) One layer of 10mm black SBR rubber flooring with DOW PU binder. (iii) One layer of PU Pore Sealer Coat with black powder or silica. (iv) Two layers of PU coating (2mm) (v) Two layers of Color Coat. (vi) White Game Line Marking Total Thickness - 12mm. |
| 24 | Volley ball fix Goal Post with height adjustable system and Net complete all as specified and directed. |
| 25 | INTERNAL WATER SUPPLYS&F, health faucet (ABS body) mild steel chromium plated suitable for 15mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 26 | S&F, fancy type chromium plated 2 way bib tap 15mm dia with CP flange as fixed in repair complete all as specified and directed. |
| 27 | S&F in repair 15mm pillar taps, cast copper alloy fancy type, chromium plated screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe including taking down old pillar taps complete all as specified and directed. |
| 28 | S&F, PVC floor trap with plain / single hole CP grating including jointing to waste pipe in cement joint of outlet 75mm dia as fixed in repairs complete all as specified and directed. |
| 29 | INTERNAL ELECTRIFICATIONTaking down carefully unserviceable aluminium / copper point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, sockets etc, removing materials to store for keeping in safe custody or for reuse / issued under Schedule of Credit and making good the distrubed surface as the existing one complete all as specified and directed. |
| 30 | Taking down exiting copper / aluminium sub main wiring complete for taking credit (credit for above items should be made as per conditions separately) and making good to disturbed surfaces in any type and size complete all as specified and directed. |
| 31 | S&F, surface / wall mounting essential Smart Bright LED tube light fitting light weight and screw-less linear batten with high efficacy for modern commercial applications including luminaire (with tube rod) for 1 x 40 watt LED taking down old fitting etc., complete all as specified and directed. |
| 32 | S&F, extruded aluminium batten 4 ft run length suitable for surafce, wall & conduit mounting with all mounting accessories including luminaire (with tube rod) for 1 x 22 watt LED complete all as specified and directed. |
| 33 | S&F, LED mirror light 18 W, batten type including LED lamp and all fixing arrangement connection complete all as specified and directed. |
| 34 | S&F, LED building security light 1 x 45 Watt new generation energy saving and environmental friendly long life LED high performance street light luminaire with single die ceramic base high power LED light source, IP66 protection, PDC HOUSING & aesthetic finless design and toughened glass cover and street light optics for lighting and impact resistance of IK 07 including suitable size of bracket bend in shape with 02 Nos of clamps, nuts, bolts etc; including taking down existing fitting complete all as specified and directed. |
| 35 | Supplying, installation, testing & commissioning of 70 W flood light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -50C to 500C, internal surge protection of 5 KV L, N, E as per IEC 61000-4-5, Driver efficiency >85%,THD <10% as per IEC 61000-3-2, P.F.≥0.95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, driver & electrical circuitry) of minimum 50000 |
| 36 | burning hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6500°K (as per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard complete in all respect including external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with minimum 05 year OEM warranty. System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as |
| 37 | per BIS shall be submitted, shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 38 | S&F, LED higbay light cool white 70W, 10000 lumens, CCT 5700 K, IP66 protection with complete fixing arrangement for hanging upto the level of exiting fitting including taking down old fitting etc. complete all as required and directed. |
| 39 | S&F, LED Surface mounted 38 W, 3300 lumen, CCT 6500K square shaped luminaire with low height CRCA housing and high transmissivity diffuser including taking down old fitting etc. complete all as required and directed. |
| 40 | S&F, ceiling / recess LED light fittings 20 W, round shape, high performance LED downlights for commercial applications, 100 lumen/watt efficacy, efficient heat sink (die cast) with steel clips, integrated driver control (for easy installation) complete all as required and directed. |
| 41 | Taking down the exisitng ceiling fans, exhaust fans & wall fans refixing the same after servicing repairing including greasing, oiling and painting complete all as specified and directed. |
| 42 | S&F in repair ceiling fan of size 1200mm sweep, energy saving model, AC single phase, 240 V including down rod, necessary connection with flexible copper cable from ceiling rose complete all as specified and directed. |
| 43 | S&F in repair heavy duty exhaust fan, AC single phase, 240V of size 300mm sweep with louvers including necessary connection and replacement of flexible copper cable from ceiling rose and taking down of old unserviceable fan complete all as specified and directed. |
| 44 | EXTERNAL ELECTRIFICATIONSupplying, installation, testing & commissioning of flood light of 200 W powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5oC to 50oC, internal surge protection of 5 KV L, N, E as per IEC 61000-4-5, Driver efficiency >85%, THD < 10% as per IEC 61000-3-2, P.F.≥0.95, IP-66, IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tiltable |
| 45 | fitting, life time (LED, driver & electrical circuitry) of minimum 50000 burning hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6500°K (as per ANSI Bin), SDCM (Standard Deviation Colour Matching) <5, maximum power consumption should not more than the specified rating and fixture shall be of relevant BIS standard complete in all respect including external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with minimum 05 year OEM warranty. |
| 46 | System lumen efficacy >135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted, shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) and 2.5 Sqmm three core (nominal area) PVC insulated and PVC sheathed multistranded unarmed copper conductor cable LT 1100 volt grade FRLS drawn through pole for connecting to flood light and pole JBs with cable terminal pole wirings connecting up with flood light feeder (Junction Box) including unplasticised |
| 47 | PVC pipes of pressure rating 10 Kgf/cmSq 15mm bore and 3mm thick complete fixed on pole using suitable clamps nuts & bolts (not less than 03 Nos) complete with made to bracket made of MS channel 75 x 5mm approx. 1.2mtr length and fixed to pole with FI 50mm x 6mm clamps, 02 Nos and suitable size necessary nuts & bolts, including complete set painting of two coat red oxide and aluminium painted fittings with swaged tubular pole connected complete all as specified and directed. |
| 48 | S&F, pole mounting type junction box factory made, water proof & fire proof, Sheet Moulding Compound (SMC) of minimum size 290 x 200 x 100mm of FRP sheet duly powder coated with front openable hinged door, locking arrangements with 04 Nos aluminium bus bars 63 Amps rating mounted on SMC / porcelain insulator, cable glands and lugs consisting DIN type rails for fixing MCB SP 6/10 Amps, 10 kA suitable for domestic loading - 01 No., including mild steel flat iron clamp and supporting flat iron made out of 40 x 4mm FI, nuts, bolts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 49 | S&F in repair automatic operation street light timing switch having lighting control (ON-OFF) through Astronomical Calculation of sunrise / sunset by setting date, time and degree of longitude and latitude without separate light sensors and prewired with suitable size of copper conductor single core PVC insulated and sheathed cable and all mechanism fitted into panel, outdoor type, pole mounted with FI 25 x 4mm clamps, nuts, bolts and washers duly painted, connecting and testing factory made, epoxy powder coated, three phase street light panel, Astronomical 24 hrs, suitable for 12 KW (max) complete with 63 Amps TP contactor and 63 Amps TPN MCBs and fixed on pole / wall / feeder pillar complete all as specified and directed. |
| 50 | Supply, installing, testing & commissioning of LT outdoor type factory made (CPRI approved), feeder pillar box of size 900mm x 750mm x 450mm (overall dimension) with mild steel angle iron of size 40 x 40 x 5mm vertical frame and legs with mild steel flat iron 40 x 6mm in horizontal sides of the frame LT FPB (KIOSK), outdoor type, platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, the panel shall be dust and vermin proof, IP 65 class protection and made of 3.15mm MS sheet and 40 x 40 x 5mm thick angle iron frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front & back opening |
| 51 | type with aprons for cable entry and fixing danger notice plate made of 1.6mm thick mild steel sheet, vitreous enamelled white of size 20 x 15cm with letter, figures and conventional skull bones in signal red colour and fixed front and back door pillar box with voltage and danger indicated in Hindi and English with double door shutter and locking arrangement (including provision of 65mm Godrej (Freedom) stranded lock - 02 Nos with 3 keys with MCCB 4 pole, 415 volts AC grade, 160 Amps rating and 25 KA rupturing capacity - 01 No aluminium bus bar of size 10 x 6mm x 400mm long with drilled holes for incoming / outgoing cable core connection including aluminium lugs, GI bolts, |
| 52 | nuts and washers of suitable size, procelain / synthetic bridge insulators, heavy duty with necessary steel / GI screws, bolts, nuts and washers, platform for the panel with PCC 1:4:8 type D2 with 40mm graded crushed stone, 15cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C1 using 20mm graded crushed stone aggregate on top and grouting bolts for feeder pillar box, the platform shall be such that it is of a height 45cm above the nearest road level complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 09, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender