Tender For Repair/Maintenance Of Ht Ug Cable ,Various Types Of Power &Distribution Transformer,Ht Breakers And Connected Works At Cme Under Ge (Cme) Khadki
Tender Value
60 Lakhs
Estimated cost
Bid Submission
06 Oct 2026
25 days left
EMD
1.15 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maintenance Of Ht Ug Cable ,Various Types Of Power &Distribution Transformer,Ht Breakers And Connected Works At Cme Under Ge (Cme) Khadki
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling and removing and setting aside for credit to contractor old unused steel tubular pole any type/size by breaking PCC foundation after disconnecting electrical connection including site clearance complete all as specified and directed by Engineer-in- Charge. |
| 2 | S & F in replacement steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11.0 metres long) complete all as specified and directed by Engineer-in- Charge. |
| 3 | M&L in repair cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat and one finishing coat of paint complete all as specified and directed by Engineer-in- Charge. |
| 4 | Supply, laying, connecting and testing in replacement XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric power cable (heavy duty) with stranded aluminium conductor for 11000 volts working voltage cross sectional area 3 core, 95 sqmm complete all as specified and directed by Engineer-in- Charge. |
| 5 | All as per item No 4 above but of size 3 core 150 sqmm |
| 6 | Supply, laying and testing in reapir XLPE insulated screened PVC bedded, galvanised steel strip/ wire armoured, electric power cables (Heavy Duty) with stranded Aluminium conductor, 22000 V grade of size 3 core 300 Sqmm including taking down old unsv cable complete all as specified and directed by Engineer-in- Charge. |
| 7 | All as per item No 6 above but of size 3 core 185 Sqmm |
| 8 | All as per item No 6 above but of size 3 core 150 Sqmm |
| 9 | All as per item No 6 above but of size 3 core 120 Sqmm |
| 10 | S&F in repair cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed by Engineer-in- Charge. |
| 11 | All as per item No 10 above but outdoor termination joint |
| 12 | All as per item No 10 above but straight through joint |
| 13 | S&F in repair cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm complete all as specified and directed by Engineer-in- Charge. |
| 14 | All as per item No 13 above but outdoor termination joint |
| 15 | All as per item No 13 above but straingh through joint |
| 16 | S&F in repair cable end termination, outdoor, heat shrinkable type joint complete with jointing material and accessories suitable for 22 KV, 3 core 120 to 185 sqmm, XLPE armoured aluminium conductor cablecomplete all as specified and directed by Engineer-in- Charge. |
| 17 | All as per item No 16 above but indoor type joint |
| 18 | All as per item No 16 above but straight through joint |
| 19 | S&F in repair cable end termination, outdoor, heat shrinkable type joint complete with jointing material and accessories suitable for 22 KV, 3 core, 300 Sqmm, XLPE armoured aluminium conductor cable complete all as specified and directed by Engineer-in- Charge. |
| 20 | All as per item No 19 above but indoor type end termination joint |
| 21 | All as per item No 19 above but straight through joint |
| 22 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed by Engineer-in- Charge. |
| 23 | All as per item No 22 above but in Soft /Loose Soil |
| 24 | All as per item No 22 above but in Hard/Dense soil |
| 25 | Excavating in trenches, n.exc 1.5 m wide but n.exc 3 m in depth; for foundation, etc. n exc 10 sq m on plan and exc 1.5 m in depth and getting out in hard/dense soil com complete all as specified and directed by Engineer-in- Charge. |
| 26 | Returning filling in including spreading levelling watering and well ramming in n.exc. 25 Cum complete all as specified and directed by Engineer-in- Charge. |
| 27 | Removing the excavated material ( soil ) n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point complete all as specified and directed by Engineer-in- Charge. |
| 28 | Supply & spread sand for cushioning of cables laid in trenches complete all as specified and directed by Engineer-in- Charge. |
| 29 | Supply and laying unreinforced precast concrete cable cover, class HV, Type I flat of size 300mm x 180mm x40mm complete all as specified and directed by Engineer-in- Charge. |
| 30 | S&F in repair GI tubing light grade with all fittings for protection of cable laid in tranches or fixing to pole , wall with suitable size of FI clamp complete all as specified and directed by Engineer-in- Charge. |
| 31 | All as per item No 28 above but in 100 mm dia bore |
| 32 | All as per item No 28 above but in 80 mm dia bore |
| 33 | S&F in repair pin type, porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and directed by Engineer-in- Charge. |
| 34 | S&F in repair disc type, porcelain vitreous 145 mm high and 255 mm dia ball and socket type white, brown or green insulator single disc assembly for conductors working pressure 11 KV gradecompletecomplete all as specified and directed by Engineer-in- Charge. |
| 35 | S&F in repair disc Type, Porcelain, vitreous, white, brown green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts for 22 KVcomplete all as specified and directed by Engineer-in- Charge. |
| 36 | S&F in repair pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, for 22KV grade ccomplete all as specified and directed by Engineer-in- Charge. |
| 37 | S&F in repair lightining arresters expulsion type complete with all fittings transmission class discharge capacity 65 Kilo Amp suitable for 11000 volts complete including taking out old unservicable lightining arrester complete all as specified and directed by Engineer-in- Charge. |
| 38 | S&F in repair Polymeric expulsion fuse unit single pole mounted on insulator & steel frame complete with fused barrel (drop out fuse) suitable for 11 KV for current rating upto 200 Amp complete all as specified and directed by Engineer-in- Charge. |
| 39 | S&F in repair polymeric gang operated air Brake switch triple pole mechanically operated mounted on insulator & steel frame with operating mechanisam worked from ground level suitable for 11 KV for current rating upto 400 Amp of approved make with and including operating rod, GI tubing 25mm dia medium grade single piece of suitable length and insulated handlecomplete all as specified and directed by Engineer-in- Charge. |
| 40 | S&F in repair lightning arresters expulsion type complete with all fittings transmission class discharge capacity 10 Kilo Amp suitable for 22KV complete all as specified and directed by Engineer-in- Charge. |
| 41 | S&F in repair Polymeric HT 22 KV outdoor type dropout fuses double stack channel type complete with insulator of rating up to 200 Amps complete all as specified and directed by Engineer-in- Charge. |
| 42 | S&F in repair Polymeric gang operated air brake switch triple pole mechanically operated mounted on insulator & steel frame with operating mechanisam worked from ground level suitable for 22 KV for current rating upto 400 Amp of approved make with and including operating rod, GI tubing 25mm dia medium grade single piece of suitable length and insulated handle complete all as specified and directed by Engineer-in- Charge. |
| 43 | M&L for bituminous road cutting to a width of 60cm and depth 90cm for laying of HT cable and making good with PCC (1:3:6) type B1(using 20mm grade stone aggregate) complete all as specified and directed by Engineer-in- Charge. |
| 44 | M & L for scrapping of old painted surfaces of electric pole covered by dust and other deposited materials by cleaning from steel tubular pole of length upto 11 metres including cross arms, bracing, clamps etc and painting with one coat of aluminium paint, retaining & repainting marking on pole & replacement of reflective band of width 4 cm RED-YELLOW-RED alternate coloured 3 numberscomplete all as specified and directed by Engineer-in- Charge. |
| 45 | M & L for scrapping existing deteriorated old aluminium paint by hard wire brush painting the existing 2 pole structure by aluminium paint including cross arms, support angles, clamps and any other structural part complete all as specified and directed by Engineer-in- Charge. |
| 46 | All as per srl item No. 41 herein above but for 4 pole structure. |
| 47 | All as per Srl item No. 41 herein above but for 6 pole structure. |
| 48 | M & L for fault detection in damaged HT/LT UG cable by using cable fault detector/locator vehicle mounted comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc to accuracy of 2 meter for various location inside CME for UG cables of any size any type upto 22 KV incl excavation & Earthwork in any type of stratra to usually inspect/repair the damaged cable when and where required complete all as specified and directed by Engineer-in- Charge.Note : (i) Compaint will be notified to contractor on mobile phone at any time and contractor is responsible to rectify the fault within 4 hrs after notification, failing which Rs. 500/- per hrs shall be recovered from contractors dues. (ii) Rates included necessary earth work in any type of strata or road for opening the cable and prepare the cable ready to jointing work and making good to match with existing finishes. |
| 49 | M & L for Loose filling with aggregates of broken stone gauge 40 to 80 mm in HT substation yard complete including removal of any debris etc allcomplete all as specified and directed by Engineer-in- Charge. |
| 50 | M & L for scrapping existing deteriorated old paint by hard wire brush, painting the existing HT bus bar panel by aluminium paint including handles minor parts complete and any other structural partcompletecomplete all as specified and directed by Engineer-in- Charge. Please Enable Macros to View BoQ information |
| 51 | M & L for scrapping existing deteriorated old paint by hard wire brush, painting the existing HT bus bar panel by aluminium paint including handles minor parts complete and any other structural partcompletecomplete all as specified and directed by Engineer-in- Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 25 daysOct 09, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 28 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender