Housing Urban and Rular Development Government Departments Closing in 11 days TDR #57358688

Tender For M & R To W.S.S. At Talegaon Industrial Area...Replacement & Repairs Of Miscellaneous Electrical Circuitry System Like Avr, Protection And Power Control Panel, Air Pump, Inflator, Pneumatic Pump At Wtp Talegaon, Raw & Pure Water Works.

Issued by Government Departments · Pune, Maharashtra
Tender Value
39.65 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
11 days left
EMD
39700
Bank guarantee accepted
Document Fee
8850
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for M & R To W.S.S. At Talegaon Industrial Area...Replacement & Repairs Of Miscellaneous Electrical Circuitry System Like Avr, Protection And Power Control Panel, Air Pump, Inflator, Pneumatic Pump At Wtp Talegaon, Raw & Pure Water Works.

BOQ

Name of Work:- M & R to W.S.S. at Talegaon industrial area...Replacement & repairs of miscellaneous electrical circuitry system like AVR, Protection and power control Panel, Air Pump, inflator, Pneumatic pump at WTP Talegaon, Raw & Pure water works.
Sl. No. Item Description
1Sub Estimate for Replacement & repairs of miscellaneous electrical circuitry system like AVR, Protection and power control Panel, Air Pump, inflator, Pneumatic pump at WTP Talegaon, Raw & Pure water works.
21) Supply, Unloading, Storage, Aligning, Installation, testing & commissioning of LV panel boards compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. as required and as per IS 8623 or refer latest IEC/IS Standards specifications. Panel has to be fabricated out of 14 / 16 SWG CRCA sheet, and surface treated with phosphate seven tank process and duly powder coated with RAL 7035 or any approved color with Aluminium busbar The rates should also include its supporting/mounting arrangement as per actual GA diagrams & site conditions.1.1) Main LT Panel Incomer: 1 No of 630A EDO, ACB 50kA FP, MICROPROCESSOR based for Incomer with RYB Indicators, On, Off, Trip Indicators, Multifunction Meter, Digital Ammeter etc. Outgoing: 2Nos of. 400A, 36KA, TP Thermal Based MCCB based with LSIG Protection with ON & OFF Indication Lamps for APFC Panel and Ascaltor Panel 1 Nos of. 250A, 36KA, TP Thermal Based MCCB based with LSIG Protection for Backwash Pump 2Nos of. 125A, 36KA, TP Thermal Based MCCB based with LSIG Protection for MLD Panel and Recycling Panel 1 Nos. for spare.
31) 1) Supply, Unloading, Storage, Aligning, Installation, testing & commissioning of LV panel boards compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. as required and as per IS 8623 or refer latest IEC/IS Standards specifications. Panel has to be fabricated out of 14 / 16 SWG CRCA sheet, and surface treated with phosphate seven tank process and duly powder coated with RAL 7035 or any approved color with Aluminium busbar The rates should also include its supporting/mounting arrangement as per actual GA diagrams & site conditions.1.2) 250KVAR APFC Panel Incomer: 1 No of 400A 36 kA Thermal Magnetic Based MCCB for Incomer with On, Off, Trip Indicators, Multifunction Meter, etc Outgoing: 2 Nos of 50 kVAR Capacitor Bank with 100A TP MCCB as incomer with Contractor, Selector Switch, ON OFF Push Button Illumination Type Indication, etc. 3 Nos of 25 kVAR Capacitor bank with 63A TP MCB as incomer with Contractor, ON Push Button Illumination Type 3 Nos of 20 kVAR Capacitor bank with 40A TP MCB as incomer with Contractor, ON Push Button Illumination Type 1 Nos of 10 kVAR Capacitor bank with 32A MCB as incomer with Contractor, ON Push Button Illumination Type 1 Nos of 5 kVAR Capacitor bank with 10A TPN MCB ON Push Button Illumination Type Selector Switch, RYB Indicators, Push Button Etc
41) 1) Supply, Unloading, Storage, Aligning, Installation, testing & commissioning of LV panel boards compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. as required and as per IS 8623 or refer latest IEC/IS Standards specifications. Panel has to be fabricated out of 14 / 16 SWG CRCA sheet, and surface treated with phosphate seven tank process and duly powder coated with RAL 7035 or any approved color with Aluminium busbar The rates should also include its supporting/mounting arrangement as per actual GA diagrams & site conditions.1.3) Panel No. 2 Incomer: 1 No of 400A, 36kA FP, TM based MCCB for Incomer with RYB Indicators, On, Off, Trip Indicators, Multifunction Meter Outgoing: 4Nos of. 100A, 25KA, 4P Thermal Based MCCB based with LSIG Protection with ON & OFF Indication Lamps for Filter Outlet, Backwash 2 Nos of. 63A, 10KA, 4P MCB with ON Indication Lamp for Air Wash
51) 1) Supply, Unloading, Storage, Aligning, Installation, testing & commissioning of LV panel boards compartmental cubicle type freestanding with appropriate cable entries, front operating, front maintained wherever required complete with base frame etc. as required and as per IS 8623 or refer latest IEC/IS Standards specifications. Panel has to be fabricated out of 14 / 16 SWG CRCA sheet, and surface treated with phosphate seven tank process and duly powder coated with RAL 7035 or any approved color with Aluminium busbar The rates should also include its supporting/mounting arrangement as per actual GA diagrams & site conditions.1.4) Panel No. 3 - Changeover panel Incomer: EB - 1 No of 200A, 36kA FP, TM based MCCB for Incomer with RYB Indicators, On, Off, Trip Indicators, Multifunction Meter DG - 1 No of 200A, 36kA FP, TM based MCCB for Incomer with RYB Indicators, On, Off, Trip Indicators, Multifunction Meter 200 Amp. Motorised Chageover Switch Outgoing: 1Nos of. 100A, 25KA, 4P Thermal Based MCCB based with LSIG Protection with ON & OFF Indication Lamps 2 Nos of. 63A, 10KA, 4P MCB with ON Indication Lamp.
62) LT Cables (Aluminum) (CB-LT/AL).2.1) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
72) LT Cables (Aluminum) (CB-LT/AL).2.2) Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 240 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
83) Voltage Stabilizers. 3.1) Supplying and erecting fully automatic line Voltage stabilizer buck and boost type for operation on input voltage 160 to 270 V and output voltage 230 V + 1% rated for 3 kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core flexible cord and 3 pin 6/16 A plug top complete with overload & short circuit protection
94) Cable Joints & End Termination Kits (LT Cables) (CB-JT/LT).4.1) Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 70 to 120 sq mm., with necessary material as per specification No. CB-JT/LT
104) Cable Joints & End Termination Kits (LT Cables) (CB-JT/LT).4.2) Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 240 to 300 sq mm., with necessary material as per specification no. CB-JT/LT
115) Cable Enclosures (CB-CE).5.1) Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete.
125) Cable Enclosures (CB-CE).5.2) Supplying & laying (including excavation) reinforced cement concrete pipe of NP-2 class of 150 mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
135) Cable Enclosures (CB-CE).5.3) Supplying and laying (including excavation of suitable width & depth up to 90 cm) 160 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete.
146) Cable Tray (CB-CT).6.1) Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG GI sheet of 150 mm width & 100 mm height with required standard accessories.
157) Supplying, erecting, testing and commissioning of soft starters control panel for three phase 415 V, A.C. supply water pump up to 2 No x 50 HP consisting of RS-485 communication port, compact size & range, internal bypass contactor, 400% max. allowed overload of nominal current, with compatibility with teleservice software \\"remote drive\\" on internet, having protection for motor overload, phase sequence, excess start time, phase loss, power circuit fault, supply frequency, communication failure combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated vibration proof enclosure with IP54 protection with single phasing, phase reversal, phase imbalance, etc. complete.
168) Supplying, erecting, testing and commissioning of soft starters control panel for three phase 415 V, A.C. supply water pump up to 2 No x 25 HP consisting of RS-485 communication port, compact size & range, internal bypass contactor, 400% max. allowed overload of nominal current, with compatibility with teleservice software \\"remote drive\\" on internet, having protection for motor overload, phase sequence, excess start time, phase loss, power circuit fault, supply frequency, communication failure combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated vibration proof enclosure with IP54 protection with single phasing, phase reversal, phase imbalance, etc. complete.
179) Supplying, erecting, testing & commissioning SS01 LB-10 TM100L ELGi Make RECIPROCATING AIR COMPRESSOR having capacity 2.12 CFM. Maximum working pressure 10.0 Bar , Normal working pressure 7.0 Bar No. of Stages 1 with Main motor Nominal rating 1 HP Dimensions 1270mm*390mm*840mm (L*B*H) Weight of the package 100 Kg Air Receiver Capacity 100 L At normal working pressure erected on a common frame with proper coupling and electric connection from control panel , as per detailed specification & erected on base frame including All Material, Labour, Trial & testing etc. completed. SCOPE OF SUPPLY : Receiver Tank Mount Horizontal receiver tank with drain plugs Sockets with plugs on each dish safety valve Drive System Belt drive system Top Block: - Cast iron top block and cylinders - Forged crank shaft and connecting rods - Stainless steel valve plates - Aluminum pistons with piston rings - Air filter - Aluminum finned after cooler pipe Controls and Safety: - Pressure switch with unloader Direct on line start : Non – return valve
1810) Repairing, servicing and overhauling of existing twin lob type rotary air blower having capacity 1800 cum /hr., pressure 0.4 kg /cm2 in the new WTP building .including all required material , spare- parts ,technician , foundation alignment & electric panel work, Trial & testing etc. complete Job.
1911) Repairing, servicing and overhauling of existing twin lob type rotary air blower having capacity 1200 cum /hr., pressure 0.4 kg /cm2 in the OLD WTP building .including all required material , spare- parts ,technician , foundation alignment & electric panel work ,Trial & testing etc. complete Job. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57358688
AUTHORITY Government Departments
TENDER VALUE 39.65 Lakhs
LAST DATE 21-09-2026
Authority
Authority Name Maharashtra Industrial Development Corporation
Work Description Tender for M & R To W.S.S. At Talegaon Industrial Area...Replacement & Repairs Of Miscellaneous Electrical Circuitry System Like Avr, Protection And Power Control Panel, Air Pump, Inflator, Pneumatic Pump At Wtp Talegaon, Raw & Pure Water Works.
Basic Detail
Tender No 37581
Bidding Type Tender
Location
City Pune
State Maharashtra
Key Dates
Publish Date 04 Sep 2026
Submission Date 21 Sep 2026
Open Date 22 Sep 2026
Finance
Tender Value 39.65 Lakhs
Tender Fee 8850
EMD 39700
Exemption Available
Document List
45c94829-88d1-4f5c-9ba8-2e6506be595c.html
BOQ_2283947.xls
ItemSpecification.pdf
TenderdocumentsAVR.pdf
Tendernotice_1 (72).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Sep 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

45c94829-88d1-4f5c-9ba8-2e6506be595c.html

xls

BOQ_2283947.xls

pdf

ItemSpecification.pdf

pdf

TenderdocumentsAVR.pdf

pdf

Tendernotice_1 (72).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders