Tender For Modification And Repairs Of Compressor Room / Instrument Room In Fcl Building At Csir-Iict, Hyderabad.
Tender Overview
Project Description
Tender for Modification And Repairs Of Compressor Room / Instrument Room In Fcl Building At Csir-Iict, Hyderabad.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-Sep-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 18-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 3 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 4 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats |
| 5 | Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | 15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall. |
| 7 | French spirit polishing : Two or more coats on new works including a coat of wood filler |
| 8 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge. |
| 9 | Repair of aluminium window, shutters and partitions etc., providing and change of wheels handles with PVC/neoprene gasket etc., complete as per the architectural drawings and as directed by Engineer-in-Charge |
| 10 | Providing and fixing polyster fabric Roller blinds of approved design as per the direction of Engineer-in-charge. Product or its equivalent approved make and shade/desgin as per the manufacturers specifications and as directed. |
| 11 | Supply of 4C x 16 sq.mm Al. Conductor armoured XLPE, PVC sheathed 1.1kV grade, ISI marked cable. |
| 12 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm) |
| 13 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle) |
| 14 | Rewiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C |
| 15 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 MM |
| 16 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (Make: Finolex) |
| 17 | (i) 3 x 4 sq. mm |
| 18 | (ii) 5 x 6 sq. mm |
| 19 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required as directed by engineer incharge. Make: Legrand Myrius |
| 20 | (i) 6 Module |
| 21 | (ii) 12 Module |
| 22 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make: Legrand Myrius |
| 23 | (i)5/6 A switch |
| 24 | (ii)15/16 A switch |
| 25 | (iii)3pin 5/6 A socket outlet |
| 26 | (iv)6 pin 15/16 A socket outlet |
| 27 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 28 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper busbar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door Make:Legrand |
| 29 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:Legrand |
| 30 | Single pole |
| 31 | Double pole |
| 32 | Triple pole and neutral |
| 33 | Supply of poly carbonate 1x18 watts, 4feet, LED Tube light set, along with 1xTLED fixture, LED Tube-1no, complete with all accessories as directed by Incharge Electrical.Cat.no.TMC501P 1xTLED 20W-14# LED tube 18watts, 865, T8Make:Philips |
| 34 | Installation, testing and commissioning of pre-wired, fluorescentfitting/LED Fittings compact fluorescent fitting/LED Fittings of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 35 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32A 240 V \\"C\\" curve DP MCB complete withconnections,testing and commissioning etc. as required. |
| 36 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 37 | Disconnecting and removing of old DB/ Light fittings and Ceiling fans: Disconnecting and removing of existing Tubelight fittings/ Ceiling Fans/ wall mount fans/ Recessed LED Light fittings and Existing Switch boards, MCB Enclosure boxes, Old DB of all types including existing wiring and transporting all the dismantled materials with out any damage from the site to departmental stores/ debries yard as directed by the Engineer in charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender