Tender For Special Repair /Replacement Of Existing Unsv Bollards,Gate/Pillar Lights And Connected Misc Items Of Various Unit/Locations And Special Repair/Replacement Of Existing Unsv Hpsv/Mv/Mh/Cfl Security Light Fittings Into Led Fittings Alongwith
Tender Overview
Project Description
Tender for Special Repair /Replacement Of Existing Unsv Bollards,Gate/Pillar Lights And Connected Misc Items Of Various Unit/Locations And Special Repair/Replacement Of Existing Unsv Hpsv/Mv/Mh/Cfl Security Light Fittings Into Led Fittings Alongwith Connected Misc Items Of Various Unit/Locations And Main Rds At Borarupak Mil Stn Under Ge 872 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling / Taking out old existing Bollard light fitting of any capacity complete all as specified and directed. |
| 2 | Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 3 | S&F IP 65 rated LED bollard light fitting of capacity 10 watt new generation energy saving, with robust design and efficient light distribution complete all as specified and as directed. |
| 4 | S&F 1100 volts grade heavy duty cable PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular of size 6 Sqmm complete all as specified and as directed. |
| 5 | All as per Item No-04 but of size 4 Sqmm complete all as specified and as directed. |
| 6 | S&F (FR) PVC insulated and PVC round unsheathed multistranded copper conductor flexible cable of size 1.5 sqmm x 3 core along with PVC Conduit Pipe laid on ground for used in LED Bollard Lights complete all as specified and directed. |
| 7 | Supply and laying of GI tubing light grade in protection of cable at road crossing /hard standing/pole protection fixed with clamps as per site requirement of size 50 mm dia bore , etc all as specified and directed |
| 8 | All as per item No-07 above but size 25 mm dia bore .complete all as specified & directed. |
| 9 | Supply only for fixed in repair of DB, Single pole & Neutral, 2 way with 200 Amps rated bus bar, Single Door, 240 volts complete all as specified and directed. |
| 10 | Supply only for fixed in repair of MCB SPN, 240 volts, 32 Amps, 10 kA, 50 Hz complete all as specified and directed. |
| 11 | Dismantling / Taking out old existing Poles complete all as specified and directed. |
| 12 | Disconnecting / Taking out unsv LT UG Cables of any size complete all as specified and directed. |
| 13 | Excavation in trenches not exc 1.5 mtr width and not exc 1.5 mtr in depth and getting out in hard/dense soil for laying of UG cable complete all as specified and directed. |
| 14 | Excavating in trenches, not exceeding 1.5 mtr wide and exceeding 1.5 mtr deep and not exceeding 3 mtr deep for excavation of poles and getting out in any type of soil complete all as specified and directed. |
| 15 | Returning , filling in incl spreading, leveling , watering and well ramming in layers not exc 25 cm thick in soils , complete all as specified and directed |
| 16 | Removal of surplus soil to a distance not exc 50 mtr away and depositing where directed as a level not exc 1.5 mtr above the starting point , etc all as specified and directed |
| 17 | M&L for sand cushioning using dry and clean tibba sand in two layers, first layers of 80 mm thick before laying of cable and second layer of 150 mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. Note :- Punned thickness only will be measured and paid. |
| 18 | Supply and laying well burnt Bricks , locally available best quality (sub class \\"B\\" bricks) laid in trenches perpandicular to U/G cable for cable protection complete all as specified. |
| 19 | Supplying, errecting and fixing steel tubular swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type 410 SP-31 (8.5 metres long) including painting with two coats of aluminium paint over one coat of redoxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing 3 Nos of 30cm wide circular bands with black & yellow paint starting from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 5 cm large bold letters 2\\" (inch) wide complete all as specified and directed. (Note :- Excavation, earth work, PCC in foundation and coping shall be measured and paid separately under relevant item of this sch) |
| 20 | Material and labour for PCC 1:4:8 type D2 using 40mm stone aggregate as in foundation and mass concrete all as specified and directed. |
| 21 | Material and labour for PCC 1:3:6 type C2 using 40mm stone aggregate as in foundation mass concrete all as specified and directed. |
| 22 | Material and labour for PCC 1:2:4 type B1 using 20mm stone aggregate in coping to pole including form work all as specified and directed. |
| 23 | Supply and lay XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade of size 25 Sqmm x 4 Core complete all as specified and directed. |
| 24 | All as per item No-23 here in after but of size 16 Sqmm x 4 Core ,complete all as specified and directed. |
| 25 | All as per item No-23 here in after but of size 16 Sqmm x 2 Core ,complete all as specified and directed. |
| 26 | All as per item No-23 here in after but of size 10 Sqmm x 2 Core ,complete all as specified and directed. |
| 27 | Cutting the existing road straight by manual 50/80 mm dia dore, depth and width not less than 1 Mtr below ground level for passing of underground cable and filling back with excavated soil up to 75 % road portion and 25 % shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed. |
| 28 | S&F Automatic Street light Time Swith Panel, 3 Phase, 415 volts, 50 Hz comprising of power contactor of rating 32 Amps/TP controlled by automatic Digital Type all prewired suitable for 3 phase operation including MCB TPN 40 Amps as incomming all enclosed in suitable size MS enclosure with locking arrangement fixed to PCC/steel tubular poles with necessary clamps made out of MS flat Iron 30 mm X 5 mm thickness along with provision of cable entiies etc complete all as specified and directed. |
| 29 | Supply and fixing LED street light fitting of capacity 35 Watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal anagement in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 30 | All as per item No-29 above but of capacity 60 Watt ,complete all as specified and directed. |
| 31 | Supply and fixing LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp all as specified and directed. |
| 32 | S&F pole mounted shockproof and rustproof Junction Box rectangular shape, 4 way of size 240X130X95 mm indoor/outdoor type and fixing with one MCB SP 10 Amps, 'C' curve, 10 kA including fixing with two nos flat iron clamps of suitable size with necessary mild steel nuts & bolts complete all as specified and as directed. |
| 33 | M&L Street light bracket made out of 150 cm long 25/32/40 mm dia light grade GI pipe with provision of nut and bolts for fixing on top of the pole duly painted with two coats of silver paint over a coat of red oxide primer complete all as specified. |
| 34 | S&F (FR) PVC insulated and PVC round unsheathed multistranded copper conductor flexible cable of size 1.5 sqmm x 3 core along with PVC Conduit Pipe laid on ground for used in LED Bollard Lights complete all as specified and directed. |
| 35 | Supply, lay, commissioning and testing of cable jointing Kit for 1100 V grade cable for straight through joint with jointing material and accessories suitable for aluminium conductor cable of size upto 50 Sqmm x 3.5 Core complete all as specified and directed. |
| 36 | S&F sheet metal enclosure double break Switch Fuse Unit (Main Switch), 100 Amps TPN, 415 V complete all as specified and directed. |
| 37 | S&F sheet metal enclosure double break Switch Fuse Unit (Main Switch), 63 Amps TPN, 415 V complete all as specified and directed. |
| 38 | M & L for painting the existing LT Steel Poles including cross arms, clamps, street light junction boxes etc with 2 coats of aluminium paint over a coat of red oxide primer including throughly cleaning the existing surface, writing of pole numbers in yellow circle 15 cm with black paint on poles. Painting the poles up to 1.5 Mtr height with alternate bands 30 cm height (3 Nos black and 2 Nos Yellow) from ground level, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender