Agriculture Boards / Undertakings / PSU Closing in 2 days TDR #57348532

Tender For Repairs And Renovation Work Of Electrical Installations At Fci R.O. Building Bhopal.

Issued by Boards / Undertakings / PSU · Bhopal, Madhya Pradesh
Tender Value
15.17 Lakhs
Estimated cost
Bid Submission
16 Sep 2026
2 days left
EMD
30360
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repairs And Renovation Work Of Electrical Installations At Fci R.O. Building Bhopal.

BOQ

Name of Work:- Repairs and Renovation work of electrical installations at FCI R.O. building Bhopal.
Sl. No. Item Description
1Sub Head - 1 (Establishment)
2SPECIAL CONDITIONS : 1) The work shall be carried out in coordination with the Civil Works in live building, wherever required, to ensure proper execution and sequencing of the associated works. 2) Bidders are advised to visit the site and acquaint themselves with the site conditions, existing installations and other relevant aspects before submission of their bid. 3) The existing electrical installations shall be retained and reused to the extent found technically suitable and serviceable at site. Replacement or new provision shall be undertaken only for those portions found unserviceable, unsafe or unsuitable for continued use, as determined by the Engineer-in-Charge during execution.4) All electrical materials shall conform to relevant BIS/IS standards, wherever applicable, and visible installations shall have a neat, uniform and aesthetically compatible finish, subject to approval of the FCI.
3Careful dismantling/removal and subsequent re-laying/re-fixing of existing serviceable electrical/lane/ telephone conduits and wiring, as required in connection with the ongoing renovation works, including identification and marking, safe removal without damage, temporary storage and preservation, re-routing, re-laying/re-fixing, drawing/pulling of existing serviceable wires through conduits, making necessary connections and terminations, testing and commissioning, complete as required and as directed by the Engineer-in-Charge. Any serviceable conduit or wire damaged due to the contractor's negligence during execution shall be replaced by the contractor at his own cost.
4Supplying and fixing of following sizes of medium class PVC conduit along with accessories for recess including cutting the wall and making good the same (surface laying is allowed only in case of concrete wall.)
520 mm
625 mm
732 mm
8Supplying and fixing of following sizes of Heavy-Duty PVC Casing-Capping along with pre-made accessories like socket , connector , bends of make of reputed brand under MII confirming to relevant IS and IEC codes) as approved by Engineer in charge.
920 x 12 mm
1025 x 15 mm
11Supplying and drawing following sizes of FRLS/HFFRPVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit asrequired.
123 x 1.5 sq. mm
133 x 2.5 sq. mm
143 x 4.0 sq. mm
153 x 6.0 sq. mm
16Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
175 / 6 amp switch
183 / 5 pin 5 / 6 amp socket outlet
1915 / 16 amp switch
206 pin 15 / 16 amp socket outlet
21Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
22Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
231 or 2 Module
243 Module
256 Module
268 Module
2712 Module
28Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable in surface/recessed medium class PVC conduit, with modularswitch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable etc. as required. Group C (surface laying is allowed only in case of concrete wall.)
29Wiring for group controlled (looped) light point/fanpoint/exhaust fan point/ call bell point ( withoutindependent switch etc.) with 1.5 sq. mm FRLS/HFFRPVC insulated copper conductor single core cable insurface/ recessed PVC conduit, and earthing thepoint with 1.5 sq. mm FRLS/HFFR PVC insulatedcopper conductor single core cable etc. as required. Group C (surface laying is allowed only in case of concrete wall.)
30Supplying of following rating 240 / 415 volts \\"C\\" curve, miniature circuit breaker sutaible for lighting and inductive load of following poles etc as and when required
31Single pole (5A to 32 A)
32Double pole (5A to 32 A)
33Four Pole (63 A)
34Supplying and fixing following rating, double pole,(single phase and neutral), 240 V, residual currentcircuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete withconnections, testing and commissioning etc. asrequired.
3563 amp
36Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
3712 way , Double door
38Providing and fixing following rating and breakingcapacity and pole MCCB with thermomagneticrelease and terminal spreaders in existing cubiclepanel board including drilling holes in cubicle panel,making connections, Ics=100% Icu and OperationalVoltage 690V etc. as required.
39100 A,30KA,FPMCCB
40Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCCBs and incomer) as required. (Provision of MCCB fixing as incomer should be given)
4112 way (4 + 36), Double door
42Fabrication , supplying and installation of following size powder coated M.S. non-perforated cable trunking with suitable cover, in convenient sections, joined with suitable connectors and fixed directly on wall/railing using suitable brackets, clamps, fasteners, bolts and nuts etc., for routing and concealing LT cables, complete as required. All accessories should be prefabricated. Colour shall be as directed by Engineer incharge.
43100 mm width X 50 mm depth X 1.6 mm thickness
44150 mm width X 50 mm depth X 1.6 mm thickness
45300 mm width X 50 mm depth X 1.6 mm thickness
46Supply and fixing of following Amp 4 Pole Manual Change over of make of reputed brand under MII confirming to relevant IS and IEC codes) as approved by Engineer in charge
4763 AMP
48Supplying of surface mounted cool white following watt Led battens in Powder Coated CRCA Sheet Body (Thickness >0.50 mm) of make of reputed brand under MII confirming to IS and IEC codes respectively including acessaries for connection and fixing etc. as required directly on wall with round block as approved by Engineer In Charge.
49LED BATTEN LIGHT 20W (+/- 2W)
50LED BATTEN LIGHT 40W (+/- 4W)
51Installation, Testing and Commissioning of pre-wired,fluorescent fitting / compact fluorescent/ LED fitting ofall types, complete with all accessories and tube/lampetc. directly on ceiling/ wall, including connectionswith 1.5 sq. mm FRLS/HFFR PVC insulated, copperconductor, single core cable and earthing etc. asrequired.
52Supplying of 380mm sweep Exhast Fan complete suitable for 230/240 volts ,50HZ, single phase confirming to IS codes as amended from time to time running at 1400 RPM of make of reputed brand under MII confirming to relevant IS and IEC codes) as approved by Engineer in charge. Design and colour to be approved by Engineer Incharge.
53Installation, Testing and Commissioning of exhaustfan in the existing opening, including making good thedamage, connection, testing, commissioning etc. asrequired.
54Upto 450 mm sweep
55Supplying of 1200mm sweep capacitor type AC. Ceiling Fan complete with 30 cm. down rod with hanging shackle blade and canopy suitable for 230/240 volts ,50HZ, single phase confirming to ISS/374/1966as amended from time to time running at 370 RPM with air delivery of 215 cmm and opal white colour or equivalent etc as reqd. (of make of reputed brand under MII confirming to relevant IS and IEC codes) as approved by Engineer in charge . Design and colour to be approved by Engineer Incharge.
56Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required.
57Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
583 X 25 sq. mm (25mm)
59Dismantling of ceiling fan and painting the same withone or more coats of spray painting with syntheticenamel paint of approved brand and manufacture togive an even shade, including cleaning of surface withdetergent and replacing the damaged rubber reel,nuts and bolts with washers and safety pins,reinstalling the same as required.
60Dismantling and removal of redundant/unserviceable switches, sockets, DBs, MCBs, RCCBs and other associated electrical accessories/equipment, including safe disconnection and stacking of dismantled materials, complete as directed by the Engineer-in-Charge.
61Supply, Installation, Testing and commissioning of Maintenance Free chemical Earthing comprising of single Copper Pipe Electrode of 50 mm outer diameter of Length 3 meter along with highly conductive, non-corrosive material.With Supply of Earth Enhancement compound. (2 Bags of 25 K.G) which is highly hygroscopic, non-corrosive & good pH Value certified by NABL approved Lab required to fill up the excavated earth with required quantity including charges of excavation of bore of 150 mm dia of 3.5 mtr depth & shifting of bore machine from one bore to another as per requirement i/c testing of earth resistance of earth electrode by digital or analog method etc as reqd. (Make-- ISI Mark Company)
62Credit for dismantled / unseviceable items removed from office / flats.
63Conduit Pipe, old Panel Board, MS clamp, Iron material etc
64Aluminium cables, wires etc. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57348532
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 15.17 Lakhs
LAST DATE 16-09-2026
Authority
Authority Name Food Corporation Of India
Work Description Tender for Repairs And Renovation Work Of Electrical Installations At Fci R.O. Building Bhopal.
Basic Detail
Tender No 07/2026-27
Bidding Type Tender
Location
City Bhopal
State Madhya Pradesh
Key Dates
Publish Date 04 Sep 2026
Submission Date 16 Sep 2026
Open Date 17 Sep 2026
Finance
Tender Value 15.17 Lakhs
Tender Fee Ref. Documents
EMD 30360
Exemption Not Available
Document List
BOQ_971962.xls
ecca08a5-beb4-4342-9646-a29f4db2035d.html
MTF.pdf
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 16, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Sep 17, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_971962.xls

html

ecca08a5-beb4-4342-9646-a29f4db2035d.html

pdf

MTF.pdf

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender