Tender For Repairs And Renovation Work Of Electrical Installations At Fci R.O. Building Bhopal.
Tender Value
15.17 Lakhs
Estimated cost
Bid Submission
16 Sep 2026
2 days left
EMD
30360
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repairs And Renovation Work Of Electrical Installations At Fci R.O. Building Bhopal.
BOQ
| Sl. No. | Item Description |
| 1 | Sub Head - 1 (Establishment) |
| 2 | SPECIAL CONDITIONS : 1) The work shall be carried out in coordination with the Civil Works in live building, wherever required, to ensure proper execution and sequencing of the associated works. 2) Bidders are advised to visit the site and acquaint themselves with the site conditions, existing installations and other relevant aspects before submission of their bid. 3) The existing electrical installations shall be retained and reused to the extent found technically suitable and serviceable at site. Replacement or new provision shall be undertaken only for those portions found unserviceable, unsafe or unsuitable for continued use, as determined by the Engineer-in-Charge during execution.4) All electrical materials shall conform to relevant BIS/IS standards, wherever applicable, and visible installations shall have a neat, uniform and aesthetically compatible finish, subject to approval of the FCI. |
| 3 | Careful dismantling/removal and subsequent re-laying/re-fixing of existing serviceable electrical/lane/ telephone conduits and wiring, as required in connection with the ongoing renovation works, including identification and marking, safe removal without damage, temporary storage and preservation, re-routing, re-laying/re-fixing, drawing/pulling of existing serviceable wires through conduits, making necessary connections and terminations, testing and commissioning, complete as required and as directed by the Engineer-in-Charge. Any serviceable conduit or wire damaged due to the contractor's negligence during execution shall be replaced by the contractor at his own cost. |
| 4 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories for recess including cutting the wall and making good the same (surface laying is allowed only in case of concrete wall.) |
| 5 | 20 mm |
| 6 | 25 mm |
| 7 | 32 mm |
| 8 | Supplying and fixing of following sizes of Heavy-Duty PVC Casing-Capping along with pre-made accessories like socket , connector , bends of make of reputed brand under MII confirming to relevant IS and IEC codes) as approved by Engineer in charge. |
| 9 | 20 x 12 mm |
| 10 | 25 x 15 mm |
| 11 | Supplying and drawing following sizes of FRLS/HFFRPVC insulated copper conductor, single core cable inthe existing surface/ recessed steel/ PVC conduit asrequired. |
| 12 | 3 x 1.5 sq. mm |
| 13 | 3 x 2.5 sq. mm |
| 14 | 3 x 4.0 sq. mm |
| 15 | 3 x 6.0 sq. mm |
| 16 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 17 | 5 / 6 amp switch |
| 18 | 3 / 5 pin 5 / 6 amp socket outlet |
| 19 | 15 / 16 amp switch |
| 20 | 6 pin 15 / 16 amp socket outlet |
| 21 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 22 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. |
| 23 | 1 or 2 Module |
| 24 | 3 Module |
| 25 | 6 Module |
| 26 | 8 Module |
| 27 | 12 Module |
| 28 | Wiring for light point/ fan point/ exhaust fan point/ callbell point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable in surface/recessed medium class PVC conduit, with modularswitch, modular plate, suitable GI box and earthingthe point with 1.5 sq.mm FRLS/HFFR PVC insulatedcopper conductor single core cable etc. as required. Group C (surface laying is allowed only in case of concrete wall.) |
| 29 | Wiring for group controlled (looped) light point/fanpoint/exhaust fan point/ call bell point ( withoutindependent switch etc.) with 1.5 sq. mm FRLS/HFFRPVC insulated copper conductor single core cable insurface/ recessed PVC conduit, and earthing thepoint with 1.5 sq. mm FRLS/HFFR PVC insulatedcopper conductor single core cable etc. as required. Group C (surface laying is allowed only in case of concrete wall.) |
| 30 | Supplying of following rating 240 / 415 volts \\"C\\" curve, miniature circuit breaker sutaible for lighting and inductive load of following poles etc as and when required |
| 31 | Single pole (5A to 32 A) |
| 32 | Double pole (5A to 32 A) |
| 33 | Four Pole (63 A) |
| 34 | Supplying and fixing following rating, double pole,(single phase and neutral), 240 V, residual currentcircuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete withconnections, testing and commissioning etc. asrequired. |
| 35 | 63 amp |
| 36 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 37 | 12 way , Double door |
| 38 | Providing and fixing following rating and breakingcapacity and pole MCCB with thermomagneticrelease and terminal spreaders in existing cubiclepanel board including drilling holes in cubicle panel,making connections, Ics=100% Icu and OperationalVoltage 690V etc. as required. |
| 39 | 100 A,30KA,FPMCCB |
| 40 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCCBs and incomer) as required. (Provision of MCCB fixing as incomer should be given) |
| 41 | 12 way (4 + 36), Double door |
| 42 | Fabrication , supplying and installation of following size powder coated M.S. non-perforated cable trunking with suitable cover, in convenient sections, joined with suitable connectors and fixed directly on wall/railing using suitable brackets, clamps, fasteners, bolts and nuts etc., for routing and concealing LT cables, complete as required. All accessories should be prefabricated. Colour shall be as directed by Engineer incharge. |
| 43 | 100 mm width X 50 mm depth X 1.6 mm thickness |
| 44 | 150 mm width X 50 mm depth X 1.6 mm thickness |
| 45 | 300 mm width X 50 mm depth X 1.6 mm thickness |
| 46 | Supply and fixing of following Amp 4 Pole Manual Change over of make of reputed brand under MII confirming to relevant IS and IEC codes) as approved by Engineer in charge |
| 47 | 63 AMP |
| 48 | Supplying of surface mounted cool white following watt Led battens in Powder Coated CRCA Sheet Body (Thickness >0.50 mm) of make of reputed brand under MII confirming to IS and IEC codes respectively including acessaries for connection and fixing etc. as required directly on wall with round block as approved by Engineer In Charge. |
| 49 | LED BATTEN LIGHT 20W (+/- 2W) |
| 50 | LED BATTEN LIGHT 40W (+/- 4W) |
| 51 | Installation, Testing and Commissioning of pre-wired,fluorescent fitting / compact fluorescent/ LED fitting ofall types, complete with all accessories and tube/lampetc. directly on ceiling/ wall, including connectionswith 1.5 sq. mm FRLS/HFFR PVC insulated, copperconductor, single core cable and earthing etc. asrequired. |
| 52 | Supplying of 380mm sweep Exhast Fan complete suitable for 230/240 volts ,50HZ, single phase confirming to IS codes as amended from time to time running at 1400 RPM of make of reputed brand under MII confirming to relevant IS and IEC codes) as approved by Engineer in charge. Design and colour to be approved by Engineer Incharge. |
| 53 | Installation, Testing and Commissioning of exhaustfan in the existing opening, including making good thedamage, connection, testing, commissioning etc. asrequired. |
| 54 | Upto 450 mm sweep |
| 55 | Supplying of 1200mm sweep capacitor type AC. Ceiling Fan complete with 30 cm. down rod with hanging shackle blade and canopy suitable for 230/240 volts ,50HZ, single phase confirming to ISS/374/1966as amended from time to time running at 370 RPM with air delivery of 215 cmm and opal white colour or equivalent etc as reqd. (of make of reputed brand under MII confirming to relevant IS and IEC codes) as approved by Engineer in charge . Design and colour to be approved by Engineer Incharge. |
| 56 | Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required. |
| 57 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 58 | 3 X 25 sq. mm (25mm) |
| 59 | Dismantling of ceiling fan and painting the same withone or more coats of spray painting with syntheticenamel paint of approved brand and manufacture togive an even shade, including cleaning of surface withdetergent and replacing the damaged rubber reel,nuts and bolts with washers and safety pins,reinstalling the same as required. |
| 60 | Dismantling and removal of redundant/unserviceable switches, sockets, DBs, MCBs, RCCBs and other associated electrical accessories/equipment, including safe disconnection and stacking of dismantled materials, complete as directed by the Engineer-in-Charge. |
| 61 | Supply, Installation, Testing and commissioning of Maintenance Free chemical Earthing comprising of single Copper Pipe Electrode of 50 mm outer diameter of Length 3 meter along with highly conductive, non-corrosive material.With Supply of Earth Enhancement compound. (2 Bags of 25 K.G) which is highly hygroscopic, non-corrosive & good pH Value certified by NABL approved Lab required to fill up the excavated earth with required quantity including charges of excavation of bore of 150 mm dia of 3.5 mtr depth & shifting of bore machine from one bore to another as per requirement i/c testing of earth resistance of earth electrode by digital or analog method etc as reqd. (Make-- ISI Mark Company) |
| 62 | Credit for dismantled / unseviceable items removed from office / flats. |
| 63 | Conduit Pipe, old Panel Board, MS clamp, Iron material etc |
| 64 | Aluminium cables, wires etc. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 04, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 16, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysSep 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer