Tender For Repair And Maintenance Of Pumps And Cleaning Of Tanks (Oht/Ug Sumps), Repair Of Centrifugal/Submersible Pumps And Connected Items Under The Aor Of Ge Golconda.
Tender Overview
Project Description
Tender for Repair And Maintenance Of Pumps And Cleaning Of Tanks (Oht/Ug Sumps), Repair Of Centrifugal/Submersible Pumps And Connected Items Under The Aor Of Ge Golconda.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Sep-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) File No 8127/E8 Tender Inviting Authority: GARRISON ENGINEER GOLCONDA Name of Work: REPAIR AND MAINTENANCE OF PUMPS AND CLEANING OF TANKS (OHT/UG SUMPS), REPAIR OF CENTRIFUGAL/SUBMERSIBLE PUMPS AND CONNECTED ITEMS UNDER THE AOR OF GE GOLCONDA. Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder including all TaxesRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | Cleaning of RCC Over Head Reservoir of capacity 50000 Glns complete all as specified and as directed and as described below :-i) Before starting the cleaning of Over Head Reservoir, distribution line from OH tank is to be disconnected and plugged with suitable fitting. After cleaning, plugged line should be washed out and connected to the distribution pipe line as per existing position. Cost of required earth work and excavation at places is deemed to be included in item rate quoted by the contractor.ii) The inner surface of the walls and ceiling of the tank shall be cleaned with high pressure jet pump after emptying the water in the tank. iii) After thorough cleaning of the tank, the cleaning water and sludge is to be removed by using pump and the sludge has to be disposed off at a place as directed.iv) After removing the sludge from tank, the tank shall be first cleaned thoroughly by using high pressure water pump and again the floor and inner surfaces of the tank shall be cleaned by using a industrial vacuum cleaner and the tank shall be made fully dirt free.v) After making the tank dirt free, the inner surfaces of walls and ceiling of the tank shall be treated with anti bacterial agents.vi) After the treatment as mentioned at (iv) above, the inner surfaces of walls and ceiling shall be treated with UV Radiator. (v) Date of cleaning shall be marked with synthetic enamel paintNOTE : (i) The unit rate quoted deemed to be including draining of water with mechanical equipment and working in water and mud etc.(ii) The unit rate quoted deemed to be inclusive of all safety precautions which shall be taken while working on RCC over head tank/underground sump and contractor or his Engineer shall be available during execution of the job.(iii) Lighting arrangements if required shall be provided by the contractor temporarily at his own arrangements and the rate quoted is deemed to be inclusive of this and electricity / diesel shall not be provided by the department. (iv) Contractor will not be allowed more than one day to do the work inside each OH tank/UG sump to prevent interruption of water supply to the users.Over head tank of 50000 Gallon capacity at a) hill top 9 MT area/Taramati Md Accn Pump house/Outside MKD near Swimming pool at Arty Centre b) 64 ORs Map qtr, Towli Chowki Qtrs/KVS - II, and Map Md Accn (near Signal Centre Pump House) at Asif Nagar and c) Old Md Lines (Near 19 Rajput Md Accn) at MH/MD Lines |
| 3 | All as per Item No:1 here-in-before but Over head tank of 25000 Gallon capacity at following location:-a) Near cook house 9 MT area/16 Dogra Regt 7th mile area at Arty Centreb) butchery, 40 JCOs patter bldg at Asif Nagar c) MH Golconda (near SHO office) |
| 4 | All as per Item No:1 here-in-before but Over head tank of 250000 Gallon capacity near CHQ main office area at Arty Centre. |
| 5 | All as per Item No:1 here-in-before but Over Head Tank capacity of 150000 Gallon at New 40 JCO' Pump House at Asif Nagar. |
| 6 | All as per Item No:1 here-in-before but Over head tank of 100000 Gallon capacity at following location:-a) 12 Jakli unit Area at Asif Nagarb) Offrs Md Accn (Near RSI) at MH/MD area andc) Signal Centre Pump House at MH/MD area |
| 7 | All as per Item No:1 here-in-before but Over head tank of 75000 Gallon capacity at 13 Dogra Area at Asif Nagar. |
| 8 | All as per Item No:1 here-in-before but Over head tank of 25000 Ltrs capacity at 60 ASC Supply Depot Unit Area. |
| 9 | All as per Item No:1 here-in-before but Over head tank of 10000 Ltrs capacity at 613 Missile Unit Area. |
| 10 | All as per Item No:1 here-in-before but cleaning of RCC under ground sump / semi under ground sump of following :-Semi under ground sump of capacity 50000 Gallona) at Hanuman mandir PH and b)Outside MKD near Swimming pool PH at Arty Centre,c)64 ORs Map qtrs Area and Signal Centre Pump House and MAP Md Accn (near Signal Centre Pump House) at MH/MD Lines |
| 11 | All as per Item No:1 here-in-before but Semi under ground sump of capacity 30000 Gallon at Inside MKD PH/taramati Md Accn PH & Near Indoor Stadium 3 Trg Arty Centre. |
| 12 | All as per Item No:1 here-in-before but Semi under ground sump of capacity 15000 Gallon at 16 Dogra Regt PH & Pantathalom Stadium Outside MKD Arty Centre |
| 13 | All as per Item No:1 here-in-before but Semi under ground sump of capacity 10000 Gallon at :-a)Firing range PH/Inside MKD near Officers Md accn PH & IB line JCOs mess PH at Arty Centre andb) 28 JCO's pump house, 40 JCOS pattar bldg at Asif Nagar |
| 14 | All as per Item No:1 here-in-before but Semi under ground sump of capacity 250000 Gallon at IB line PH at Arty Centre. |
| 15 | All as per Item No:1 here-in-before but Semi under ground sump of capacity 300000 Gallon infront of 354 Fd Hosp area at Asif Nagar. |
| 16 | Providing Water samples collected from 5 nos source from HMWS and water quality standard test report of 16 basic quality parameters tested asper BIS10500 to be applied for NABL accreditation this report submitted to first week of every month complete all as specified and as directed. |
| 17 | Providing water samples collected from 13 nos distribution of over head tanks and water quality standard test report of 16 basic quality parameters tested asper BIS10500 to be applied for NABL accreditation this report submitted to first week of every quarter complete all as specified and as directed. |
| 18 | M&L for Attending emergency breakdown of water supply installations where directed, Lifting up defective submersible pumpset of cap 5HP, 3 phase, 415 volts, any stage and deep, column pipes (any number) from bore well, setting aside and stacking column pipes for reuse, transportation unserviceable pumpset from borewell to workshop Opening of the defective motor & pump in MES store yard/ workshop, cleaning the covers and parts as applicable in presence of Engineer in Charge to ascertain the quantum of defects and repairs involved and assembling the motor & pump after carrying out repair works to make smooth functioning, applying spray painting to the repaired motor& pump externally with two coats of synthetic enamel paint of shade as directed by the Engineer in Charge transporting repaired pumpset from workshop to bore well site after completion of repair work, lowering of submersible pumpset with column pipes in the bore well as existing with new nut bolt and washer including rubber gasket 3 mm thick, including electrical supply connections as per existing for smooth functioning of pump motors complete all as specified and directed.Note: Repair work of submersible pump set spares will measured and paid separately under respective items of this schedule. |
| 19 | All as per item 17 above here in before but for submersible pumpset and motor of capacity 7.5 HP. |
| 20 | All as per item 17 above here in before but for submersible pumpset and motor of capacity 10 HP.Note for Sl. Item Nos. 17 to 19 :-(i) Any spare parts required to replaced during repair, servicing, overhauling of motor, pump set etc shall be measured and paid separately under respective items of this schedule as supply only. Labour element involved in replacement of material shall deemed to included in the rates quoted.(ii) Any minor repairs involved to make the motor, pump functional even if notified by the Engineer in Charge shall be carried out by the contractor without any extra cost to the department.(iii) In case of rewinding of stator of motor shall be measured and paid separately under respective item of this schedule.(iv) Greasing/ oiling etc., of parts as required shall deemed to inclusive in the rate quoted. |
| 21 | Supply only the following spares required against Sl. Item No. 17, where required for submersible pumpset of capacity 5 HP as per the model and make complete all as specified and as directed. :-Water lubricant seal suitable for motor. |
| 22 | All as per item 20 above here in before but Thrust bearing for pumps |
| 23 | All as per item 20 above here in before but Bearing cover sleeve. |
| 24 | All as per item 20 above here in before but Thrust bearing for motors |
| 25 | All as per item 20 above here in before but Impeller fibre type |
| 26 | All as per item 20 above here in before but Neck ring |
| 27 | All as per item 20 above here in before but Stainless steel key for impeller shaft |
| 28 | All as per item 20 above here in before but Stainless steel motor - pump shaft coupler |
| 29 | All as per item 20 above here in before but Body bush for pump |
| 30 | All as per item 20 above here in before but Stainless steel sleeve for pump shaft |
| 31 | All as per item 20 above here in before but Pump shaft gun metal of appropriate size |
| 32 | All as per item 20 above here in before but Thrust pad |
| 33 | All as per item 20 above here in before but Rubber bushes to motor shaft. |
| 34 | All as per item 20 above here in before but Thrust plate |
| 35 | Supply only the following spares required against Sl. Item No. 18, where required for submersible pumpset of capacity 7.5 HP as per the model and make complete all as specified and as directed.:-Water lubricant seal suitable for motor. |
| 36 | All as per item 34 above here in before but Thrust bearing for pumps |
| 37 | All as per item 34 above here in before but Bearing cover sleeve. |
| 38 | All as per item 34 above here in before but Thrust bearing for motors |
| 39 | All as per item 34 above here in before but Impeller GM/PVC for 7.5HP submersible pump. |
| 40 | All as per item 34 above here in before but Neck ring |
| 41 | All as per item 34 above here in before but Stainless steel key for impeller shaft |
| 42 | All as per item 34 above here in before but Stainless steel motor - pump shaft coupler |
| 43 | All as per item 34 above here in before but Body bush for pump |
| 44 | All as per item 34 above here in before but Stainless steel sleeve for pump shaft |
| 45 | All as per item 34 above here in before but Pump shaft gun metal of appropriate size |
| 46 | All as per item 34 above here in before but Thrust pad |
| 47 | All as per item 34 above here in before but Rubber bushes to motor shaft. |
| 48 | All as per item 34 above here in before but Thrust plate |
| 49 | Supply only the following spares required against Sl. Item No. 19 where required for submersible pumpset of capacity 10 HP as per the model and make complete all as specified and as directed. :-Water lubricant seal suitable for motor. |
| 50 | All as per item 48 above here in before but Thrust bearing for pumps |
| 51 | All as per item 48 above here in before Bearing cover sleeve. |
| 52 | All as per item 48 above here in before Thrust bearing for motors |
| 53 | All as per item 48 above here in before Impeller GM/PVC for 7.5HP submersible pump. |
| 54 | All as per item 48 above here in before Neck ring |
| 55 | All as per item 48 above here in before Stainless steel key for impeller shaft |
| 56 | All as per item 48 above here in before Stainless steel motor - pump shaft coupler |
| 57 | All as per item 48 above here in before Body bush for pump |
| 58 | All as per item 48 above here in before Stainless steel sleeve for pump shaft |
| 59 | All as per item 48 above here in before Pump shaft gun metal of appropriate size |
| 60 | All as per item 48 above here in before Thrust pad |
| 61 | All as per item 48 above here in before Rubber bushes to motor shaft. |
| 62 | All as per item 48 above here in before Thrust plate |
| 63 | M&L Rewinding of stator of submersible motor of capacity 10 HP with water proof insulated copper wire of existing gauge and size to achieve the specified / required RPM including taking out old unserviceable winding complete all as specified and directed. |
| 64 | M&L Rewinding of stator of submersible motor of capacity 7.5 HP with water proof insulated copper wire of existing gauge and size to achieve the specified / required RPM including taking out old unserviceable winding complete all as specified and directed. |
| 65 | M&L Rewinding of stator of submersible motor of capacity 5 HP with water proof insulated copper wire of existing gauge and size to achieve the specified / required RPM including taking out old unserviceable winding complete all as specified and directed. |
| 66 | Servicing, overhauling of centrifugal pump, monoblock motor pump set of capacity 75 HP, 3 phase induction motor including carrying out maintenance check along including transportation complete all as specified and as directed with following repairs:(a) Dismantling of monoblock motor pump set in presence of MES representative and display all the parts without damage any portion for inspection of Engineer in Charge to ascertain the serviceability of existing parts.(b) Heating, varnishing to stator, rotor with super quality varnish and drying out properly with external heat.(c) Cleaning, washing of bearing and use right quantity of ball bearing grease for bearing.(d) Checking play of impeller and bushing of pump.(e) Assembling of motor with old serviceable parts and replacement of unserviceable parts with new as ordered where necessary. (f) Installation of motor by making connections as per existing and testing on load. |
| 67 | All as per item No. 65 above but for centrifugal pump, monoblock motor pump set of capacity 40 HP. |
| 68 | All as per item No. 65 above but for centrifugal pump, monoblock motor pump set of capacity 30 HP. |
| 69 | All as per item No. 65 above but for centrifugal pump, monoblock motor pump set of capacity 15 HP. |
| 70 | All as per item No. 65 above but for centrifugal pump, monoblock motor pump set of capacity 10 HP.Notes :(i) Any spare parts required to replaced during servicing, overhauling of motor, pump set etc., shall be measured and paid for separately under respective items of this schedule as supply only. (ii) Labour element involved in replacement of spares shall deemed to be included in quoted rates against this item.(iii) Any minor repairs involved to make the motor, pump functional even if notified by the Engineer in Charge shall be carried out by the contractor without any extra cost to the department.(iv) In case of rewinding of stator of motor shall be measured and paid separately under respective items of this schedule.(v) Greasing/ oiling etc of parts as required shall deemed to inclusive of rate quoted by the tenderer. |
| 71 | M&L for Rewinding of stator of induction motor working on 3 phase, 440 volts for Centrifugal monoblock motor pump set of capacity 75 HP with bare copper winding of appropriate gauge, complete all as specified and as directed. |
| 72 | M&L for Rewinding of stator of induction motor working on 3 phase, 440 volts for Centrifugal monoblock motor pump set of capacity 40 HP with bare copper winding of appropriate gauge, complete all as specified and directed. |
| 73 | M&L for Rewinding of stator of induction motor working on 3 phase, 440 volts for Centrifugal monoblock motor pump set of capacity 30 HP with bare copper winding of appropriate gauge, complete all as specified and directed. |
| 74 | M&L for Rewinding of stator of induction motor working on 3 phase, 440 volts for Centrifugal monoblock motor pump set of capacity 15 HP with bare copper winding of appropriate gauge, complete all as specified and directed. |
| 75 | M&L for Rewinding of stator of induction motor working on 3 phase, 440 volts for Centrifugal monoblock motor pump set of capacity 10 HP with bare copper winding of appropriate gauge, complete all as specified and directed. |
| 76 | Supply only the following spare parts to incorporate against centrifugal monoblock motor pumpset of capacity 75 HP as required at site complete all as specified and directed.Cast iron impeller |
| 77 | All as per item 75 above here in before Ball/Thrust bearing suitable for different motor capacity as per existing. |
| 78 | All as per item 75 above here in before Gland cup gun metal heavy duty. |
| 79 | All as per item 75 above here in before Neck ring bush |
| 80 | All as per item 75 above here in before Body bush |
| 81 | All as per item 75 above here in before Thrust plate |
| 82 | Supply only the following spare parts to incorporate against centrifugal monoblock motor pumpset of capacity 40 HP as required at site complete all as specified and directed.Cast iron impeller |
| 83 | All as per item 81 above here in before Ball/Thrust bearing suitable for different motor capacity as per existing. |
| 84 | All as per item 81 above here in before Gland cup gun metal heavy duty. |
| 85 | All as per item 81 above here in before Neck ring bush |
| 86 | All as per item 81 above here in before Body bush |
| 87 | All as per item 81 above here in before Thrust plate |
| 88 | Supply only the following items to incorporate against centrifugal monoblock motor pumpset of capacity varying from 30 HP as required at site complete all as specified and directed:-Cast iron impeller |
| 89 | All as per item 87 above here in before Ball/Thrust bearing suitable for different motor capacity as per existing. |
| 90 | All as per item 87 above here in before Gland cup gun metal heavy duty. |
| 91 | All as per item 87 above here in before Neck ring bush |
| 92 | All as per item 87 above here in before Body bush |
| 93 | All as per item 87 above here in before Thrust plate |
| 94 | Supply only the following items to incorporate against centrifugal monoblock motor pumpset of capacity varying from 15 HP as required at site complete all as specified and directed:-Cast iron impeller |
| 95 | All as per item 93 above here in before Ball/Thrust bearing suitable for different motor capacity as per existing. |
| 96 | All as per item 93 above here in before Gland cup gun metal heavy duty. |
| 97 | All as per item 93 above here in before Neck ring bush |
| 98 | All as per item 93 above here in before Body bush |
| 99 | All as per item 93 above here in before Thrust plate |
| 100 | Supply only the following items to incorporate against centrifugal monoblock motor pumpset of capacity varying from 10 HP as required at site complete all as specified and directed:-Cast iron impeller |
| 101 | All as per item 99 above here in before Ball/Thrust bearing suitable for different motor capacity as per existing. |
| 102 | All as per item 99 above here in before Gland cup gun metal heavy duty. |
| 103 | All as per item 99 above here in before Neck ring bush |
| 104 | All as per item 99 above here in before Body bush |
| 105 | All as per item 99 above here in before Thrust plate |
| 106 | Taking down water level indicator unit from Over head reservoir/Semi Under ground sump, supply and fix new water level indicator with complete accessories such as copper ball, necessary pulley, nylon rope, steel patti duly painted white with marking at every 10cm interval, letter writing of size 15mm width and 100mm long with signal red radium paint and painting of indicator with illumination postal red paint and erected at the height of 3 meter from ground level with necessary angle iron, nut and bolts complete all as specified and as directed. |
| 107 | Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hexagonal head screw including taking out old unserviceable one complete all as specified and as directed. |
| 108 | S&F Air termination, single pointed aluminium rod 12mm dia and 300mm long including taking out old unserviceable one complete all as specified and as directed. |
| 109 | Supply, laying, connecting, testing and commissioning PVC insulated, PVC sheathed armoured, heavy duty electric power cable with multi stranded copper conductor, 1100 volts grade, of cross-sectional area 2.5 Sqmm 3 - core for aviation obstruction light of OH reservoir upto 25m height including cutting to required lengths and connecting with necessary lugs and glands at both ends and taking out the existing burnt/ unserviceable one from panel/ starter complete all as specified and as directed. |
| 110 | Supply and replace MCB DB DD 4 - way SPN 240 Volts and removing unserviceable materials out of site including connecting complete all as specified and as directed. |
| 111 | Supply and replace existing unserviceable MCB SPN 5 - 30 Amps complete all as specified and as directed. |
| 112 | Supply and replace aviation obstruction light aviation yellow painted die cast aluminium alloy housing built in heat resistant clear thick glass and accessories LED aviation obstruction light suitable to operate on 230 volts single phase AC supply complete on OH reservoir complete all as specified and as directed. |
| 113 | Disconnecting existing water level indicator, taking out defective MS wire rope from overhead tanks of any head, pulley, ball and replacing with new MS wire rope, ball of dia 300mm with provision for fixing wire, greasing and refixing both the pullies on another side as directed including marking the level on the indicator complete all as specified and as directed. |
| 114 | S & F foot valve of 80 MM dia size for CI pipeline as that of existing model complete with necessary nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing complete all as specified and as directed. Make : Kirloskar / Upadhaya or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 115 | S & F foot valve of 100 MM dia size for CI pipeline as that of existing model complete with necessary nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing complete all as specified and as directed. Make : Kirloskar / Upadhaya or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 116 | S & F foot valve of 150 MM dia size for CI pipeline as that of existing model complete with necessary nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing complete all as specified and as directed. Make : Kirloskar / Upadhaya or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 117 | S & F Air release valve of 50 MM dia size to the existing CI/DI pipeline as that of existing model complete with necessary , balls, nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing complete all as specified and as directed. Make : Kirloskar / Upadhaya or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 118 | S & F NRV of 80 MM dia size to the existing CI pipeline as that of existing model complete with necessary , balls, nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing complete all as specified and as directed.Make : Kirloskar / Upadhaya or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 119 | S & F NRV of 100 MM dia size to the existing CI pipeline as that of existing model complete with necessary , balls, nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing complete all as specified and as directed.Make : Kirloskar / Upadhaya or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 120 | S & F NRV of 150 MM dia size to the existing CI pipeline as that of existing model complete with necessary , balls, nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing complete all as specified and as directed.Make : Kirloskar / Upadhaya or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 121 | S & F NRV of 200 MM dia size to the existing CI pipeline as that of existing model complete with necessary , balls, nuts,bolts and gasket as per site requirement fixing in position complete including taking out existing complete all as specified and as directed.Make : Kirloskar / Upadhaya or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 122 | Supply and fix in repair plastic jar for chlorine dosing complete all as specified and directed. |
| 123 | Supply and fix in repair chlorine dosing pump system 6 BPH at 4 Bar complete all as specified and directed. |
| 124 | Supply and lay galvanized steel water tubing medium grade of 50 mm bore complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions including taking up or down existing steel tubing with fittings complete all as specified and directed. |
| 125 | Supply and lay galvanized steel water tubing medium grade of 40 mm bore complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions including taking up or down existing steel tubing with fittings complete all as specified and directed. |
| 126 | Supply and lay galvanized steel water tubing medium grade of 80 mm bore complete with all fittings such as bends elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps and pigs, unions including taking up or down existing steel tubing with fittings complete all as specified and directed. |
| 127 | S&F for gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe of 50mm bore including taking down complete all as specified and directed. |
| 128 | S&F for gunmetal globe or gate valve with iron wheel head screwed both ends for iron pipe of 40mm bore including taking down complete all as specified and directed. |
| 129 | M&L for 150 mm dia Ductile iron pipes with spigot and socket end including tyton joints, Class K-9 laid in trenches alongwith taking up or down GI/CI/DI water mains 150mm dia (including all fittings) with spigot and socket ends and lead joints, burning out points and recovering lead complete all as specified and directed. |
| 130 | Material & Labour DI fittings for spigot/flanged end pipes such as bends any type (radius and angle) tapers any type (straight, bend increasing or decreasing double socket flanged etc), Tee pieces, single branch, 'Y' junction, double branch cross (all socket or socket and spigot or flanged, Collars, caps and plug etc up to 250mm bore complete all as specified and directed |
| 131 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in Hard / Dense soil complete all as specified and as directed. |
| 132 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc.,25cm thick each layer in hard/dense soils complete all specified and as directed. |
| 133 | Removing excavated materials to a distance not exc 50 M and depositing where directed at a level not exc. 1.5 M above the starting point complete all as directed |
| 134 | Supply and fix in repair steel water tubing, galvanized, heavy duty, 50 mm bore, column pipe, both ends threaded, including taking down existing pipe complete all as specified and directed. |
| 135 | Supply and fix in repair steel water tubing, galvanized, heavy duty, 40 mm bore, column pipe, both ends threaded, including taking down existing pipe complete all as specified and directed. |
| 136 | Supply and fix GI socket, heavy duty, 100mm long, 50mm bore, complete all as specified and directed. |
| 137 | Supply and fix GI socket, heavy duty, 100mm long, 40mm bore, complete all as specified and directed. |
| 138 | Supply and fix High density polyethylene pipes (HDPE) of pressure rating 16 kgf/cm2 of 50mm bore both end threaded alongwith fittings all as specified and directed. |
| 139 | Supply and fix High density polyethylene pipes (HDPE) of pressure rating 16 kgf/cm2 of 75mm bore both end threaded alongwith fittings complete all as specified and directed. |
| 140 | Supply, laying and testing 3 core 16 Sqmm, PVC insulated and FR PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694, fixed to Centrifugal motor pump set to fully automatic starter, complete, including taking out old unserviceable cable of any description complete all as specified and directed. |
| 141 | Redevelopment of tube well of maximum depth of 100 mtr by means of pumping by Air compressor of minimum pressure 10 Kg/cm2 (compressor to be arranged by contractor at his own cost), until sand free and clean water is obtained complete all as specified and directed. |
| 142 | Supply, laying and testing PVC insulated and sheathed flat 3 core 6 Sqmm, copper stranded conductor water proof submersible cable fixed to submersible monoblock pump set to starter, complete, including taking out old unserviceable cable of any description complete all as specified and directed. |
| 143 | Supply, laying and testing PVC insulated and sheathed flat 3 core 10 Sqmm, copper stranded conductor water proof submersible cable fixed to submersible monoblock pump set to starter, complete, including taking out old unserviceable cable of any description complete all as specified and directed. |
| 144 | S & F 3 pole power contactor, AC3 heavy duty 415 volts 25 A rating, with 2 NO+2NC, 240/415 Volts coil rating as per site requirement complete including taking down old unserviceable from the panel board/starter complete all as specified and directed. |
| 145 | S & F 3 pole power contactor, AC3 heavy duty 415 volts 40 A rating, with 2 NO+2NC, 240/415 Volts coil rating as per site requirement complete including taking down old unserviceable from the panel board/starter complete all as specified and directed. |
| 146 | S & F relay of DOL starter capacity 30 Amps as that of existing make and model including fixing in position connection, commissioning and testing complete, including taking down unserviceable over load relay complete all as specified and directed. |
| 147 | S&F in repairs Star delta starter timer capacity 30 Amps including taking down existing star delta starter timer, complete all as specified and directed. |
| 148 | S & F of DOL starter capacity up to30 Amps as that of existing make and model including fixing in position connection, commissioning and testing complete, including taking down unserviceable DOL starter complete all as specified and directed. |
| 149 | M & L for cutting of road, hard standing of approx. depth 2 meter made of concrete or premix carpet, WBM, soiling and moorum filling including excavation for laying of pipe line all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed. |
| 150 | M & L for cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and moorum filling including excavation for laying of pipe laying all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.[ Note : Approx. width of road cutting shall not exceed 30cm] |
| 151 | Repair/rectification of leakages to water supply distribution lines 15 mm dia to 25 mm dia GI tubing with provision of necessary excavation, returning and filling in as required, tightening of loose joints of union, elbow, sockets etc, threading if required including replacement of GI unions/sockets/nipples etc and upto 01 meter of GI pipe as required at site complete all as specified and directed.(Note :- (a ) The quoted rated is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station under AOR of GE Golconda. (b)The cost of excavation / earth work and repairs to damaged roads/PCC, existing structure etc shall be deemed to be included in the quoted unit rate (c) GI fittings of any size and upto 01 meter of pipe shall be deemed to be included in the quoted unit rate |
| 152 | All as per Srl Item No 150 here in before but for GI tubing 40 mm dia to 50 mm dia. |
| 153 | M & L for attending break down of water supply pipe line and repair to CI/DI/GI water mains of size 80 mm to 150 mm dia at a given notice including necessary excavation in mud, in any type of soil by manual or using special T &P etc. De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI specials such as collars bends/tail pieces etc and making joints complete all as specified and as directed. |
| 154 | M & L for attending break down of water supply pipe line and repair to CI/DI/GI water mains of size 200 mm to 300 mm dia at a given notice including necessary excavation in mud, in any type of soil by manual or using special T &P etc. De-watering from the trenches by using pump sets, rectification of leakages, fixing of CI specials such as collars bends/tail pieces etc and making joints complete all as specified and as directed. (Note for srl item Nos 38 to 42:-(a) CI/DI fittings, lead Joints etc shall be measured and paid separately. (b)The cost of excavation / earth work and repairs to damaged roads, existing structure etc shall be deemed to be included in the quoted unit rate (c) GI fittings of any size and upto 01 meter of pipe shall be deemed to be included in the quoted unit rate(d) The quoted rated is deemed to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered Military station under AOR of GE Golconda. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender