Tender for Tender for Work Of Electrification Under The Renovation Work In Various Rooms Of The State Guest House Bijapur, Dehradun And Permanent Beautification Work On The Main Gates Through Electrical Lighting.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 Sep 2026
2 days left
EMD
76000
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dehradun → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Work Of Electrification Under The Renovation Work In Various Rooms Of The State Guest House Bijapur, Dehradun And Permanent Beautification Work On The Main Gates Through Electrical Lighting.
BOQ
| Sl. No. | Item Description |
| 1 | PART-AWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group c ) |
| 2 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cableetc. as required. |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required . |
| 4 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 5 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 6 | 2 X 6sq. mm + 1 X 6 sq. mm earth wire |
| 7 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C |
| 8 | Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 9 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface/ recessed steel/ PVC conduit as required. |
| 10 | 3 x 1.5 sq. mm |
| 11 | 3 x 2.5 sq. mm |
| 12 | 3 x 4 sq. mm |
| 13 | 3 x 6 sq. mm |
| 14 | Supply and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.(2 pair) |
| 15 | Supply and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 16 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 17 | 20 mm |
| 18 | Supply and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 19 | 5/6 A switch |
| 20 | 15/16 A switch |
| 21 | 3 pin 5/6 A socket outlet |
| 22 | 6 pin 15/16 A socket outlet |
| 23 | Telephone socket outlet |
| 24 | Supply and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 25 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 26 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 27 | 1 or 2 Module (75mmX75mm) |
| 28 | 4 Module (125mmX75mm) |
| 29 | 6 Module (200mmX75mm) |
| 30 | 8 Module (125mmX125mm) |
| 31 | 12 Module (200mmX150mm) |
| 32 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 33 | 1 or 2 Module |
| 34 | 4 Module |
| 35 | 6 Module |
| 36 | 8 Module |
| 37 | 12 Module |
| 38 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 39 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing andfixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 40 | Supply and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 41 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 42 | Wiring for group controlled (looped) light point/fanpoint/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group C) |
| 43 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 44 | Supply & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\"curve including connections, painting etc. as required. |
| 45 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A, 16 KA,TPMCCB |
| 46 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 47 | 8 way , Double door |
| 48 | 12 way , Double door |
| 49 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 50 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 51 | Single pole |
| 52 | Triple pole |
| 53 | Supplying and fixing following rating, double pole, 240 V,isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 54 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 55 | Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor with day light dimming(lighting level shall be regulated as per availability of natural day light in an area along with occupancy detection.) having high preformance, regulating programmable type, suitable for connected load upto 10Amp , for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary fixing arrangements i/c programming at site etc. complete as required. |
| 56 | S/F 10 watt, 100Lm/W or above 2ft LED tube fitting complete in all respect as required. |
| 57 | S/F 20W watt, 100Lm/W or above 4ft LED tube light al housing fitting complete in all respect as required. |
| 58 | S/F 8 watt or above decorative Mirror LED light fitting complete in all respect as required. |
| 59 | S/F premium decorative pendant glass light (excluding bulb) (excluding led bulb) compatible E14/E27 bulbcomplete in all respect as required. |
| 60 | S/F RJ 45 cat 6 data outlet with shutter in the existing box complete in all respect as required. |
| 61 | S/F Ding dong electronic door bell. |
| 62 | S/F of 1x1 square 24 Watt LED recess Ceiling Light panel 4000/5700/6500K, ,105 Lm/w or above complete in all respect as required. |
| 63 | S/F of 15 watt, 100 lm/w or above, Round Type Aluminium Housing Refessed Downlight 4000K/5700K/6500K complete in all respect as required. |
| 64 | S/F of 40 Watt or above 4ft suspended Aluminium Housing linear Downlight 4000k/5700K/6500K complete in all respect as required. |
| 65 | SITC of 240 led/mtr, 5m in length 9w/meter or above LED Strips Light with suitable driver warm white/cool white/natural white complete in all respect as required. |
| 66 | S/F of 4 Watt candle filament Bulb 2700K complete in all respect as required. |
| 67 | S/F of premium decorative glass metal body Wall light (excluding led bulb) compatible E14/E27 bulb complete in all respect as required. |
| 68 | S/F of 400mm wall fan RPM 1300 or above, air delivery 80 or above cmm complete in all respect as required. |
| 69 | S/F of 25 Liters vertical Geyser with Copper Heating Element, metal storage tank, Overheat Protection, Pressure Release Valve, rust proof body 5 star rating complete in all respect as required. |
| 70 | SITC of 1200 mm Decorative Ceiling fan including wiring the down rods of standard length (upto 30 cm) with sq mm FRLS PC insulated ,Copper Conductor ,Single core cable ,including providing and fixing Phenolic laminated sheet cover and fan box etc complete in all respect as required. |
| 71 | S/F of 200 mm ventilation/Exhaust fan , RPM 1250 or above, air delivery 500 or above CMH, with low noise operation complete in all respect as required. |
| 72 | S/F of 250 mm ventilation/Exhaust fan , RPM 1250 or above, air delivery 800 or above CMH, with low noise operation complete in all respect as required. |
| 73 | S/F of 300 mm metalic double ball bearing Exhaust fan , RPM 1400 or above, air delivery 1800 or aboveCMH, with low noise operation , cu winding complete in all respect as required. |
| 74 | S/F of 450 mm metalic double ball bearing Exhaust fan , RPM 1400 or above, air delivery 6800 or above CMH, cu winding complete in all respect as required. |
| 75 | PART B (MAIN GATE WORK) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 76 | 1x 1.5 sq. mm |
| 77 | 2x 1.5 sq. mm |
| 78 | 3 x 1.5 sq. mm |
| 79 | 3 x 6 sq. mm |
| 80 | Supplying and fixing of 20 mm sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 81 | Supply and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 82 | 5/6 A switch |
| 83 | 3 pin 5/6 A socket outlet |
| 84 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 85 | Supplying and fixing 8 Module (125mmX125mm) size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 86 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A, 16 KA,TPMCCB |
| 87 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door |
| 88 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 89 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 90 | Single pole |
| 91 | Triple pole |
| 92 | Supplying and fixing 63A rating, double pole, 240 V,isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 93 | Supplying and fixing 63A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 94 | Providing, laying and fixing 100mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and re-filling etc as required |
| 95 | Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. |
| 96 | Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal) size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. |
| 97 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1 :3:6 (1 Cement : 3 coarse sand (zone-Ill) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 98 | Constructing masonry Chamber 60x40x90 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for G.I./HDPE DWC pipe of different types of cable/wires , with water proof type suitable size C. I. black paint cover plate lid including necessary excavation, inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete complete in all respect as required. |
| 99 | Earth work in excavation by electro- mechanical/ hydrailic machine in hard surface (concrete ) for pipe size upto 100mm , including getting out the excavated soil and disposal of surplus excavated soil as directed, within 200 m. complete in all respect |
| 100 | Making in cement concrete foundation 1:3:6 (1 cement: 3 coarse sand: stone aggregate 10 mm nominal size) or proper cement concrete foundation as directed including excavation and refilling for 1m Bollard Light pole of in Soft Soil including proper finishing - as required complete in all respect. |
| 101 | S/L of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 4C×6 Sq mm Al armoured cable in the existing RCC/ HUME/ METAL/HDPE DWC pipe as required. complete in all respect. |
| 102 | S.I.T.C of 40W watt or above morden design LED decorative Post Top 360 degree indirect light with following or better specification-PDC housing, 4kv surge protection cct 2700K/3000/k4000K/5700K/6000K or weather proof IP 65, resistant to corrosion, glare free and better uniformity complete in all respect as required. |
| 103 | S.I.T.C of 10-12 W LED 360° light distribution bollard light with minimum following or better specifications:100lm/w efficacyAutomatic Lower (120v) / Higher (300) Cut off voltageIK 7, IP 65, CRI-70, Pole height- 800mm,Diffuser Material UV stabilized - Poly CarbonateInput operating Voltage range - 140 V to 270 V, AC, 1Phasefrequency- 50 Hz +/-2AC Power Factor at full load, Minimum-0.95Protection against surges and transients - Internal:->/= 4 KVReverse polarity, Over volt, Short circuit, Over loadCCT- 3000K/4000K/5700K/6000K complete in all respect as required. |
| 104 | S/F 4W or above warm white up & down light (2way) outdoor wall light 6w weather proof IP 65, resistant to corrosion, complete in all respect as required. |
| 105 | S/F 4W or above focus / spike light weather proof IP 65, resistant to corrosion, complete in all respect as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysSep 29, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 3 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender