Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #57345691

Tender For Modernization/Upgradation Of Existing Parks/Green Belts.Sh : Supply, Installation And Testing Commissioning Of 4 Mtr. G.I. Pole Alongwith 45 Watt Led Street Lights And Accessories Including Panel Etc. At Hudu Block Pit Ura.

Issued by Local Bodies · Delhi, Delhi
Tender Value
7.21 Lakhs
Estimated cost
Bid Submission
14 Sep 2026
0 days left
EMD
14422
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Modernization/Upgradation Of Existing Parks/Green Belts.Sh : Supply, Installation And Testing Commissioning Of 4 Mtr. G.I. Pole Alongwith 45 Watt Led Street Lights And Accessories Including Panel Etc. At Hudu Block Pit Ura.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Sep-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 14-Sep-2026

BOQ

Name of Work:- Modernization/Upgradation of Existing Parks/Green Belts.SH : Supply, installation and testing commissioning of 4 mtr. G.I. pole alongwith 45 watt LED street lights and accessories including panel etc. at HUDU block pit ura.
Sl. No. Item Description
1Supplying and Fixing of Double Over Hang (DOH) Bracket- for 50-80 dia. MS/GI Pole made of MS Pipe with 300 mm long top galvanized MS Tube of suitable diameter for Light Fitting accommodation, connection etc. complete as required.
2Providing and laying in position 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) reinforced cement concrete foundation of size 450 mm x 450 mm x 1200 mm deep (800 mm below ground level and 400 mm above ground level) including excavation of earth, refilling, providing, cutting, bending and placing in position, reinforcement of cold twisted bars of 12mm. dia-1200mm long (approx) -8Nos, and reinforcement ring of cold twisted bar of 8mm dia -1400mm long (approx) -6 nos, (with suitable spacing) including centering & shuttering as required with providing, fixing and positioning of one set of foundation bolts comprising of 4 nos., 16 mm dia, 750 mm long J-Type MS bolts (Threaded portion shall be galvanized) along with 3 nos. GI nuts and 2 nos. GI washers etc. per bolt and 1 no. anchor plate (3mm thick) of suitable size and providing 63 mm.(O.D) DWC pipe ISI marked for cable entry & exit etc. complete as required.
3Supplying, Installation, Testing & Commissioning of Street Light LED Fixture Powder Coated Pressure Die Cast Aluminum body with driver as per the requirement with Driver Efficiency>85%, Input voltage: 140-270 Volt AC, Frequency 50/60 Hz, Operating Temp range-5°C to 50°C, Internal Surge Protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency>85%, THD<10% as per IEC 61000-3-2 , PF≥0.95, IP- 66, IK-10, CRI>70, Under Voltage and Over Voltage Protection, EMI-EMC As per CISPR 15, Lenses for Beam Angle as per IESNA type I/II/III as per the width of the road and the project requirement, suitable to fit in up to 65 mm dia. pipe, life time (LED, Driver & Electrical Circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K/4000°K/5700°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<5, Maximum Power Consumption should not more than the specified rating and Fixture shall be of relevant BIS Standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC Insulated Copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System Lumen Efficacy≥120<135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED Fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal Management: Heat Sink of Aluminum Housing such that LED Junction Temperature shall not rise above 90°C).
4Supply and Installation of Pole Connector Box made out of Glass Reinforced Polyester Sheet Moulding Compound Conforming to IS:13410-1992 Grade-S1 of Outside Dimensions 280 mm (H) x 170 mm (W) x 115 mm (D) (all the corners of the box should be round & not pointed ones) suitable to mount on 40/50/65/80 mm dia. GI Pole with the following Provisions/Accessories Mounting in Box etc. complete as required.a) 2 Nos. Clamps made out of 19 mm x 3 mm MS Strip of suitable Length for Mounting Box on the Pole.b) Water Tight Front Cover with 2 Nos. Stainless Steel Hinges & 1 No. Screw for Tightening.c) 4-Way, 220 V, 30 A, Dough Moulded Connector with SMC with Stainless Steel Inserts- 1 No.d) 16 A, Moulded SMC Rewireable Kit-Kat- 1 No.e) Suitable size Hole at suitable Location on Rear Wall for Cable & Wire Entry in the Connector Box.f) Earthing Bolt M6 x 20 mm.g) Neutral Link- 1 No.
5Supplying of following sizes of XLPE (Cross Linked Poly Ethylene) Insulated PVC Sheathed Alumimium Conductor Armoured Power Cable of 1.1 KV grade including connection, testing etc. as required.2C x 16 sq. mm
64C x 25 sq. mm
7Providing and Fixing 6 SWG dia. GI wire on surface or in recess for loop earthing along with existing surface/recessed conduit/sub-main wiring/cable as required.
8Supplying and Laying of following size DWC HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS: 14930, Part-II complete with fitting and cutting, jointing etc. direct-in-ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.a)63 mm dia. (OD-63 mm & ID-51 mm nominal)
9Laying of one number PVC Insulated and PVC Sheathed/XLPE Power Cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required.Up to 35 sq. mm
10Supplying and drawing of following sizes FRLS PVC Insulated Copper Conductor, Single Core Cable in the existing surface/recess steel/PVC conduit as required.3C x 1.5 sq.mm
11Supplying, Installation, testing and commissioning of floor mounted LT feeder pillar cubical type double door of size 1000 mm x 900mm x 300 mm deep duly compartmentalized and with general arrangement made out of 2mm thick CRCA sheet having hinged gasket cover and screwed knobs with double locking arrangement and rain protection covers 100 mm and supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls,duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles,ferrules wherever required, painting, numbering including supply and fixing of following accessories complete etc. as required (as per drawing approved by Engineer-in-charge) . (a)100 Amps.30KA Four Pole MCB ('C'-Series), ----1 No.(b)16 Amps. SP MCB ('C'-Series), 10 kA------ 6Nos(c)6A-32 A DP MCB ('C'-Series),10KA ------1No.(d) Analogue Timer switch for daily operation and toggle switch for auto/manual --1 No. (e) 32 Amps. AC-3, 3 pole power contactor -----1 No. (f) 30 Ampere 4 way neutral link/connector ------2 Nos. (g) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No (h) Ammeter (0-30 A) 96mm X 96mm square type----1 no.(i) Phase Indicating Lamp Set with fuses ----1 Set (j) Danger notice plate -----1 No (k) AI. Bus Bar 100 amp. 4 strip, 300 mm long with sleeve and nut bolts-----1 Set. .(l) Lifting hook on the top of panel board and lighting arrangement inside the feeder pillar---- 1 No.
12Supplying, Installation, testing and commissioning of floor mounted L.T. feeder pillar (meter panel) cubical type double door of size 1000 mm x 900mm x 300 mm deep with general arrangement made out of 2mm thick M.S. CRCA sheet having hinged gasketted covers and screwed knobs with double locking arrangement and rain protection covers 100 mm, supported with MS angle iron legs and bottom frame of size 40mm x 40mm x 6mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering, earth studs including supply and fixing of following accessories complete as required (as per drawing approved by Engineer-in-charge) .(a) Incomer 250 Amps. 4 pole MCCB, 36 K Amp.--1No. (b) Neutral link - 2 nos. (c) 32 Amps. DP MCB ('C'-Series)------1No. (d) 32A TP MCB (C-series)----1 No. (e) 63 amp TPN MCB-----2 nos. (e) Danger notice plate -----1 No (f) Lifting hook on the top of feeder pillar ---1Set.(g) AI. Bus Bar 250 amp. 4 strip, 300 mm long with sleeve and nut bolts-----1 Set.(h) Ammeter (0-100Amp) 96mm X 96mm square type ---1 No.(i) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No.(j) Phase Indicating Lamp Set with fuses ----1 Set (k) Suitable space for energy meter alongwith bakelite sheet ---- 1 no.
13Supplying, fabrication and installation of wire mesh protection frame for existing feeder pillar made out of 10 SWG MS wire mesh (75mm x 25mm rectangle nominal) of following sizes with angle iron base frame 40 mm x 40 mm x 6 mm angle iron and with MS strip support of size 35 mm x 6 mm and 0.5 mtr. long leg support of same angle as per drawing including providing of suitable size of door with supply & fixing of godown lock including locking arrangment, painting and grouting of angle iron frame with legs in CC (1:2:4) foundation etc. as approved by Engineer-in-charge etc. complete as required.a) 1.5 mtr (W) x 1.00 mtr(D) x 2.00 mtr. (Height).
14Earthing with GI Earth Pipe 4.5 meter long, 40 mm dia. including accessories, and Providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
15Supply and installation of 15 watt elegantly designed sleek surface mounted pressure die-cast aluminium luminaire in powder coated white finish in round/square profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver etc. complete as reqd including supply from nearest pole and as approved from engineer inchrge as per site requirement.
16Providing and Fixing 25 mm x 5 mm GI Strip on surface or in recess for connection etc. as required.
17Shifting of existing 6mtr./4 mtr. Pole by dismentaling existing foundation i/c excavation of earth upto suitable depth and refilling the same & shifting it to suitable location and installation the same and making connection testing etc complete as required.
18Providing& laying of DWC HDPE pipe of size 63 mm outer dia, by trenchless technology with no dig method by making bore hole in horizontal direction across the road/path with boring equipment i/c jointing / cleaning of pipes, excavation of pits of required size & depth etc. complete as required.
19Painting and numbering (2 coating) of existing G.I. pole of upto 4 /5mtr. hight including painting of base plate & mounting arrangement etc. complete as reqd. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57345691
AUTHORITY Local Bodies
TENDER VALUE 7.21 Lakhs
LAST DATE 14-09-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for Modernization/Upgradation Of Existing Parks/Green Belts.Sh : Supply, Installation And Testing Commissioning Of 4 Mtr. G.I. Pole Alongwith 45 Watt Led Street Lights And Accessories Including Panel Etc. At Hudu Block Pit Ura.
Basic Detail
Tender No 38/EE(E)/ELD-12/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 09 Sep 2026
Submission Date 14 Sep 2026
Open Date 15 Sep 2026
Finance
Tender Value 7.21 Lakhs
Tender Fee Ref. Documents
EMD 14422
Exemption Available
Document List
8cb66e10-ef4d-43da-b56b-88ebb0ed87b6.html
BOQ_971893.xls
NIT38.pdf
PressNotice38.pdf
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 09, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 14, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Sep 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Sep 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

8cb66e10-ef4d-43da-b56b-88ebb0ed87b6.html

xls

BOQ_971893.xls

pdf

NIT38.pdf

pdf

PressNotice38.pdf

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail