Tender For Supplying And Laying Of 500 Mm Dia Di Transmission Main From Madhavaram Booster To Muthamizh Nagar Wds In Area Iv.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
22 Sep 2026
7 days left
EMD
3.87 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supplying And Laying Of 500 Mm Dia Di Transmission Main From Madhavaram Booster To Muthamizh Nagar Wds In Area Iv.
BOQ
| Sl. No. | Item Description |
| 1 | PREAMBLE |
| 2 | The Bill of quantities shall be read in conjunction with the instruction to Bidders, General and Special Conditions of Contract, Technical Specifications, and Drawings. |
| 3 | The quantities given in the Bill of Quantities are estimated and only provisional, and are given to provide a common basis for bidding. The basis of payment will be actual quantities of work ordered and carried out, as measured by the contractor and verified by the engineer and valued at the rates and prices bid in the priced Bill of Quantities, where applicable, and otherwise at such rates and prices as the Engineer may fix within the terms of contract. Only the pipes, specials and valves that are actually use at the site alone be eligible for payment, extra quantity of specials transported at the site that are not used should be removed from the site and are not eligible for payment. |
| 4 | The rates and prices bid in the priced Bill of quantities shall, except insofar as it is otherwise provided under the Contract, include all the Constructional plant, labour, supervision, materials, erection, maintenance, insurance, profit, taxes and duties, together with all general risks, liabilities and obligations set out or implied in the Contract. |
| 5 | A rate or price shall be entered against each item in the priced Bill of Quantities, whether quantities are stated or not. The cost of Items against which the Contractor has failed to enter a rate or price shall be deemed to be covered by other rates and prices entered in the bill of Quantities. |
| 6 | General discussion and description of work and materials are not necessarily repeated nor summarised in the Bill of Quantities. References to the relevant sections of the contract documentation shall be made before entering prices against each item in the Bill of Quantities. |
| 7 | Provisional sums included and so designated in the Bill of Quantities shall be expanded in whole or part at the direction and discretion of the Engineer. |
| 8 | The method of measurement of completed work for payment shall be in accordance with standard method of measurements of the institution of Civil Engineers. |
| 9 | Errors will be corrected by the Employer for any arithmetic errors in computation or summation as follows stated in clause 27 of ITB Vol.I |
| 10 | Abbrevations used in the Bill of Quantities have the meaning shown below. mm : Millimetre cm : Centimetre m : Metre Sqm/m2 : Square metre Cum/m3 : Cubic meter MT : Metric tonne CI : Cast Iron D.I. : Ductile Iron R.C.C : Reinforced Cement Concrete Wt : Weight Kg : Kilogram M.S : Mild Steel Rmt : Running Metre |
| 11 | Supplying and laying of 500 mm dia DI Transmission main from Madhavaram Booster to Muthamizh Nagar WDS in Area IV. |
| 12 | Cutting Asphaltic / Cement concrete road Hiring of power drilling machine for cutting the road for a thickness of 30 cm |
| 13 | Mathur Booster to R.V.Nagar WDS and Muthamizh Nagar WDS |
| 14 | Providing Iron Barricading of size 2.50 m width and 1.75 m height using 40x40x4 mm angle for outer frame supports, 25 x 25 x 3 mm angle for inner frame supports and 20 gauge thickness MS sheet for name board (as per drawing) including cutting, welding, fabrication charges and one coat of primer and 2 coats of enamel paint of approved quality, writing \\"METRO WATER\\" & work detail/ caution sign, providing necessary interlocking arrangements with adjoining units, fixing danger flags, danger lights, reflectors, fixing stickers etc, including watching during night and placing the barricading units as directed at the site |
| 15 | Mathur Booster to R.V.Nagar WDS and Muthamizh Nagar WDS |
| 16 | Cutting D.I Mains |
| 17 | 450mm Dia DI pipe (K9 Pipe) |
| 18 | 500mm dia DI pipe (K9 pipe) |
| 19 | Supplying, Laying and jointing D.I pipes including earthwork excavation for trenches in hard stiff clay, blackcotton, hard red earth, shales, murams, gravel, stoney earth and earth mixed with small sixe boulders and hard gravelly soil depositing the earth on banks with initial lead of 10m and initial llift of 2m carting the pipes from any of the Board's Stores to the site of work lowering into the trenches, aligning, rerfilling the trenches with excavated soil, watering and ramming to consolidation, etc., complete for the pipes of following diameters. |
| 20 | 450mm Dia DI pipe (K9 Pipe) |
| 21 | 500mm dia DI pipe (K9 pipe) |
| 22 | Supplying and Fixing Following Specials |
| 23 | 500mm dia MJ Collar |
| 24 | 500mm dia Sluice Valve |
| 25 | 500mm dia F/Sipgot tail piece |
| 26 | 500 mm DI Fl/ Soc tail piece |
| 27 | 500x100 mm S/S/F Tee |
| 28 | 500 mm DI D/F 90 deg bend |
| 29 | 700mm dia MJ Collar |
| 30 | 700x500 mm DI tee |
| 31 | 450mm dia MJ Collar |
| 32 | 450mm dia Sluice Valve |
| 33 | 450mm dia F/Sipgot tail piece |
| 34 | 450 mm DI Fl/ Soc tail piece |
| 35 | 500x450 mm DI A/S Taper |
| 36 | 450mm dia 90 deg bend |
| 37 | 100mm air valve with sluice valve |
| 38 | 450 xx100 mm S/S/F Tee |
| 39 | Construction of thrust blocks using Cement Concrete 1:3:6 ,40mm B.G.jelly for Plain Cement Concrete |
| 40 | 500mm 90 deg bend |
| 41 | 450mm dia 90 deg bend |
| 42 | Hire charges for diesel pumpset for 5 HP with fuel and crew charges including transportation. |
| 43 | Construction of chamber for 300mm to 450mm dia. sluice valve including providing and fixing FRC cover and frame of size 60 x 60cm for size 1.35 x 1.2x 1.55 m. |
| 44 | Construction of chamber for 450mm to 600mm dia.sluice valve including providing and fixing FRC cover and frame of size 60 x 60cm for size 2 x 2.5 x 3 m. |
| 45 | Construction of air valve chamber -100mm |
| 46 | Testing of M.S/C.I/P.V.C/D.I pipes with hydraulic testing equipment by filling with water ( includeing cost of water @Rs.84/KL) and testing to recommended pressure in convenient streches and attending the bursts if any occurred during the test, excudling the cost of pipes, including other incidental and operational charges, etc., complete for the following diameters of pipes.- 300mm dia. |
| 47 | 450mm dia DI K9 pipe |
| 48 | 500mm dia DI pipe (K9 pipe) |
| 49 | As built survey for every sewage and water pipeline and other assets must be done using DGPS based RTK method by transferring the coordinates from the nearest Static GCP of CMWSSB and establishing TBMs for the project area as instructed by CMWSSB Engineer.Where there are signal interruptions for the RTK method, Total Station can be used.The coordinates from the static GCP shall be transferred to the Total Station by RTK method and the co- ordinates of the assets can then be captured by Total Station. While surveying by RTK method, it shall be ensured that the values are captured by “fixed” status.The DGPS RTK survey report including “fixed” or “float” for the coordinates captured and horizontal & vertical precision with raw data in OEM nativity file format like (.mdb, .jxl, .tet, etc) shall be submitted. All the features, attributes of all the assets, utilities captured shall be Geo referenced as per standard Coordinate reference system (WGS 84 UTM Zone 44N). The final base map with assets and utilities shall be furnished in (.shp) format. The geo referenced assets and utilities along with the attributes (as specified by the GIS Wing, CMWSSB) shall be converted into proper geo database (FGDB / PGDB) with the attributes. One set Hard and Soft Copy of all the CMWSSB assets and utility has to be prepared category wise network wise in A0 Print for verification in a print scale of 1:1000 in A0 plot, with standard legends in international and NUIS standards and should be legible and three sets of final Hard Copy in A0 print. For the Underground / Surface Assets along the roads for the distance above 2km & upto 5km. |
| 50 | SCENARIO -2: TBM Available |
| 51 | For the Point Underground Surface Assets along the Road |
| 52 | Electromagnetic Flow Meter shall be a velocity sensing Electromagnetic type, microprocessor based signal converter, sealed housing, flanged tube meter for 1.0 Mpa working pressure, manufactured to highest standard available for mag-meters, equipped with minimum six digit digital totalizers, reading in different units (Kiloliters / Cubic meter) and shall be accurate within 0.5% of Measured value, shall operate within a range of 0.3 m/sec to 4 m/sec and be constructed as follows: Meter tube (Sensor) shall be fabricated from stainless steel tube and use class PN10 flat face carbon steel flanges in accordance with IS 1538. These flanges shall be welded to the flow tube. The internal and external of the meter tube shall be blasted to near white and lined with hard rubber/ Polyurethrene/ PTFE preferably by SBR or EPDM. Meter tube shall have a constant nominal inside diameter offering no obstruction to the flow. The accuracy should be inclusive of linearity, hysteresis, repeatability, temperature and pressure effects. Coil Housing shall be fabricated from stainless steel (SS304)/ Die cast Aluminium/ Carbon steel with anticorriosive paint for corrosion resistance and welded to the tube providing a completely sealed environment for all coils, electrode connections and wiring harness capable of submerged or buried operation with IP68 Protection. |
| 53 | Signal Converter shall be pulsed DC coil excitation type with auto zeroing. The signal converter shall be remotely mounted away from the meter. The converter shall indicate direction of flow and provide a flow rate indication and a total of flow volume for both forward and reverse directions. The converter shall provide an isolated 4-20 mA output into minimum 500-ohm load and a frequency output of a maximum of 0-10 KHZ and a scaled pulse output. The microprocessor based signal converter shall have a self-diagnostic test mode and a backlit display that continuously displays “Rate of Flow” and “Total Volume”. Converter shall be supplied with a programmable low flow drop out, higher flow and empty pipe zero return. The signal converter housing should be die-cast aluminum with glass window. The converter cum transmitter should be fully programmable from the front facia. The programming should be user friendly, self-prompting menu driven. Flow meter test calibration certificate from FCRI, flow test lab / NABL accredited lab to be furnished and with 5 years warranty. |
| 54 | 450mm |
| 55 | Total excluding GST |
| 56 | GST @18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysSep 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓