Defence Statutory Bodies & Commissions/Committees Closing in 26 days TDR #57344783

Tender For Replacement Of Ht / Lt Cables Against Ber At Rci Under Ge (I) R&D Rci Hyderabad

Issued by Statutory Bodies & Commissions/Committees · Ranga Reddy, Telangana
Tender Value
5.48 Crore
Estimated cost
Bid Submission
01 Oct 2026
26 days left
EMD
5.99 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ranga Reddy → Telangana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Replacement Of Ht / Lt Cables Against Ber At Rci Under Ge (I) R&D Rci Hyderabad

BOQ

Name of Work:- REPLACEMENT OF HT / LT CABLES AGAINST BER AT RCI UNDER GE (I) R&D RCI HYDERABAD
Sl. No. Item Description
1=B2& \\" BoQ\\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: CHIEF ENGINEER (R&D) SECUNDERABAD Name of Work: REPLACEMENT OF HT / LT CABLES AGAINST BER AT RCI UNDER GE (I) R&D RCI HYDERABAD Contract No: CERD/SEC/TOKEN/ 19 OF 2026-2027 Bidder Name : PRICE SCHEDULE( This BOQ template must not be modified / replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # SlNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency Rate in Figures to be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e. DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit, if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes Total Amount Total Amount in Words
2Supply laying & testing cable HT XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts, earthed, grade cross sectional area of size 3 Core 185 Sqmm complete all as specified and directed.
3All as per Sl item No 1 above but for 3 core x 120 Sqmm cable
4All as per Sl item No 1 above but for 3 core x 95 Sqmm cable
5Supply laying & testing cable LT XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade of size 3.5 Core x 400 Sqmm complete all as specified and directed.
6All as per Sl item No 4 above but for 3.5 core x 185 Sqmm cable
7All as per Sl item No 4 above but for 3.5 core x 120 Sqmm cable
8All as per Sl item No 4 above but for 3.5 core x 95 Sqmm cable
9All as per Sl item No 4 above but for 3.5 core x 35 Sqmm cable
10All as per Sl item No 4 above but for 3.5 core x 25 Sqmm cable
11All as per Sl item No 4 above but for 4 core x 16 Sqmm cable
12All as per Sl item No 4 above but for 4 core x 10 Sqmm cable
13All as per Sl item No 4 above but for 2 core x 10 Sqmm cable
14All as per Sl item No 4 above but for 2 core x 6 Sqmm cable
15Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in hard / dense soil complete all as specified and directed.
16Supply and spread M crushed sand free from clay filled in trenches for cable cushioning covering both top and bottom of cable and punned down complete all as specified and directed. Note : Punned thickness will be measured for payment.
17Returning, filling in , including spreading, levelling, watering and well ramming in layers not exceeding 25 cms complete all as specified and directed.
18Removal of excavated soil to a distance not exceeding 50 mtrs and deposited where directed at a level not exceeding 1.5mtrs above the starting point complete all as specified and directed.
19Supply and lay un reinforced pre cast concrete cable cover class HV type I flat size 300 X 180mm X 40mm ISI marked complete all as specified and directed.
20Supply and lay un reinforced pre cast concrete cable cover class LV type II flat size 300 X 180mm X 40mm ISI marked complete all as specified and directed.
21Supply and fix, cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 sqmm complete all as specified and directed.
22Supply and fix cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm complete all as specified and directed.
23Supply and fix cable jointing kit for 11 KV (Earthed) grade Indoor / Out door cable for heat shrink type End Joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 sqmm complete all as specified and directed.
24Supply and fix cable jointing kit for 11 KV (Earthed) grade Indoor / Out door cable for heat shrink type End Joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm complete all as specified and directed.
25Cutting of existing bituminious/PCC road or flooring/plinth protection, for laying of GI pipe in road intersection for passing of LT / HT XLPE cable including excavation in any type of soil, returning and filling in and making good top 30 cm of the trench by providing PCC 1:2:4 type B1 using 20mm graded stone aggregate to flush with existing road surface complete all as specified and directed.
26S&F, 150mm dia GI pipe light grade fixed to walls/poles or laid in trenches, road crossing etc., for protection of underground cable/earth strip including sealing ends with hessian cloth impregnated with bituminous compound in ground and with teak wood bushes for ends fixed on walls/poles complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57344783
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 5.48 Crore
LAST DATE 01-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Replacement Of Ht / Lt Cables Against Ber At Rci Under Ge (I) R&D Rci Hyderabad
Basic Detail
Tender No 84055
Bidding Type Tender
Location
City Ranga Reddy
State Telangana
Key Dates
Publish Date 03 Sep 2026
Submission Date 01 Oct 2026
Open Date 05 Oct 2026
Finance
Tender Value 5.48 Crore
Tender Fee 3000
EMD 5.99 Lakhs
Exemption Available
Document List
84055Tender.pdf
9d80495b-5043-43c8-9c1a-c09e3faee5d4.html
BOQ_882811.xls
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 26 days
Oct 05, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 30 days

Tender Documents

Download All (ZIP) ↓
pdf

84055Tender.pdf

html

9d80495b-5043-43c8-9c1a-c09e3faee5d4.html

xls

BOQ_882811.xls

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders