Defence Statutory Bodies & Commissions/Committees Closing in 1 days TDR #57344780

Tender For Repair & Maintenance Of External Electric Ug Cables, Lt Panels, Two Pole Structure, Switch Gears, High Mast Lights, Bollard Lights, Emergency Light, Street Light, Flood Light Etc And Other Misc Connected Works At Cgra And Cgae Bhubaneswar

Issued by Statutory Bodies & Commissions/Committees · Khordha, Odisha
Tender Value
22 Lakhs
Estimated cost
Bid Submission
24 Sep 2026
1 days left
EMD
44000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Khordha → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair & Maintenance Of External Electric Ug Cables, Lt Panels, Two Pole Structure, Switch Gears, High Mast Lights, Bollard Lights, Emergency Light, Street Light, Flood Light Etc And Other Misc Connected Works At Cgra And Cgae Bhubaneswar Under Ge (I)(Cg) Bhubaneswar

BOQ

Name of Work:- REPAIR & MAINT OF EXTERNAL ELECTRIC UG CABLES, LT PANELS, TWO POLE STRUCTURE, SWITCH GEARS, HIGH MAST LIGHTS, BOLLARD LIGHTS, EMERGENCY LIGHT, STREET LIGHT, FLOOD LIGHT ETC AND OTHER MISC CONNECTED WORKS AT CGRA AND CGAE BHUBANESWAR UNDER GE (I)(CG) BHUBANESWAR
Sl. No. Item Description
1Taking down carefully undergound cables of any sizes complete all as specified & directed .
2Excavation in trenches in hard/dense soil n.exc 1.5m wide and n. exc 1.5m depth getting out of soil for taking out or laying of pipe line, laying of cable, errection of poles, stay and pipe line, complete all as specified and as directed.
3Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified.
4Removal of surplus soil to a distance n. exc 50 m above the starting point complete all as specified & and as directed.
5S&F bricks fly ash bricks locally available of size 230mm x 115mm x 75mm best quality laid in trenches over sand cushioning for cable protection complete all as specified and as directed.
6M&L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable complete all as directed.
7Supply and fixing of GI tubing light grade of 50 mm dia for cable protection on pole/wall/floor etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc all as specified and directed,
8Supply and Laying in replacement XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of 185 Sqmm 3.5 Core laid in trenches or fixed on wall/floor/poles complete with cable glands & lugs cable route indicator as required all as specified and directed.
9All as per item No. 8 here-in-before but 3.5 x 95 sq mm cable
10All as per item No. 8 here-in-before but 4 x 25 sq mm cable
11All as per item No. 8 here-in-before but 4 x 16 sq mm cable
12All as per item No. 8 here-in-before but 4 x 10 sq mm cable
13All as per item No. 8 here-in-before but 2 x 10 sq mm cable
14Labour for Repair/maintainace of LT cable faults by disconnecting and taking out old existing LT cable of any sizes, in any position from trench/duct/panel and removing/excavating the outer surface of cable, examining cable and joints for defects and ascertaining suitability of cable for reuse, meggering, cutting out the defective portion of cable/joint, including taking out old serviceble PCC cable covers/Bricks or GI pipe of any type/size and relaying the cable with old serviceable bricks/PCC cable covers after repair/replacement of cable / jointing kit of any make or size of existing then make good the excavated area by returning/filling the same complete all as specified & directed. Note: (a) Using of new GI pipe or new jointing kit will be paid separately in concerned items (b) Excavation, refilling and sand/cable covers as used will be paid separately. (c) Irrespective of nature of complaint fault identification and necessary minor accessories as tape/lugs/nuts bolts/testing through test lamp or meggering for any fault identification and securing cables or connected switch gear after defect rectification is deemed to be included in the scope. (d) Necessary tools /safety eqpts like hand gloves/discharge tools/helmet/torch/gum boots and other safety equipments as per standard practice is to be deemed to be included and proovided by contractor. (e) The fuse of call/breakdown and defect identification to be attended immediately within 2 hrs and process for proper defect identification should be completed in continuation alongwith any further workmen or equipment required as defect rectification being essential service in nature and the cost is deemed to be included in scope of work and also as directed. (f) Contractor is completely responsible for the safety of manpower employed by him.(g) The contactor need to arrange necessary skilled manpower immediately to restore the essential electrical services.
15Dismantling and taking out old un-serviceable Non-integral light fittings from 16 mtr High mast tower with checking its connection and unserviceable parts ,such as Drivers,LED lamps ,LED Fittings etc and replace the same and refitting in its position including servicing the double drum winch and greasing the 5 mm dia steel wire rope, wheels,operating handles with all parts and equipments of existing High mast Tower ,fitting ,Allignment upto length, testing complete in all respect after the high mast tower mounted all as specified and directed. Note: The Lights fittings to be replaced shall be measured seperately under this schedule of item.
16Supply only the following for fixing against defective components under relevants item no.21
17(a) Driver unit suitable for LED street light fittings of 150/180/200 watts
18(b) MCPCB unit suitable for LED street light fittings of 150/180/200 watts
19(c) Surge protection suitable for LED street light fittings of 150/180/200 watts
20M&L for replacement of Steel wire rope of size 6 mm dia ( as per existing) with required nuts,bolts and hooks including taking down old U/S steel wire rope from different high mast towers complete all as specifiedd & directed
21M&L for replacement of Trailing cable of Flexible copper 5 core 2.5 sqmm EPR insulated PCP Sheathed/PVC of from different high mast towers complete all as specified & directeed
22M&L for replacement of 1 HP Motor for light fittings of high mast towers complete all as specified & directeed
23S&F in replacement MCCB 4 pole with fixed thermal & magnetic release of breaking capacity 36 kA, 415 Volts, 63 Amps.(Make: Legrand 4200 92 or Standard/Legrand/HPL//Havells)
24Supply and fixing in replacement of MCCB 4 pole , 100 amp rating of 16 KA Fixed type on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board ( Make : Legrand or equivalent in ABB/Schnieder)
25Supply and fixing in replacement of MCCB 4 pole , 160 amp rating of 16 KA Fixed type on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board ( Make : Legrand or equivalent in ABB/Schnieder)
26Supply and fixing in replacement of MCCB 4 pole ,200 amp rating of 16 KA adjustable type on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board ( Make : Legrand or equivalent in ABB/Schnieder)
27M & L for cable fault finding of any size at any location complete with rectification duly joined by suitable jointing kit above 25 Sqmm cable complete all as specified and as directed.
28S&F for replacement of on load change over switch 3 phase 415 volt 50 Hz 63 Amp to be fixed in existing panel. Make LT/Havells/Legrand/C&S
29S&F for replacement of on load change over switch 3 phase 415 volt 50 Hz 100 Amp to be fixed in existing panel. Make LT/Havells/Legrand/C&S
30S&F for replacement of on load change over switch 3 phase 415 volt 50 Hz 200Amp to be fixed in existing panel. Make LT/Havells/Legrand/C&S
31Cutting Bituminous road in,making good with facing where required and pointing exc.30 cm. but not exc.1.0 mtr. girth to ends or edges teps,cills,sunshades,shelves,lintels,etc.and cutting chases for concealed water tubing or concealed conduit wiring,laying of cables and making good with old shape and size all as specified and directed.
32Supply and fixing of neon light (RYB) complete on existing LT panel board including dismantling and taking out of old items complete with connected wiring for Phase indication all as directed and specified. ( Make : L & T or equivalent)
33Supply and fixing of Ampere meter digital (0-100)Amp, along with CT's complete on existing LT panel board including dismantling and taking out of old items ( Make : L & T or equivalent)
34Supply and fixing Voltmeter digital type with of (0-440) Volt on existing LT panel board including dismantling and taking out itms complete with connected wiring for Phase indication all as directed and specified ( Make : Legrand or equivalent in ABB/Schnieder)
35Supply and fixing in replacement of air break Gang operating Drop Out (GODO) switch vertical / horizontal typeTriple pole, mechanically operated, mounted on 12 insulators and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps suitable for 11 KV complete with testing all as specified and directed by Engr-in-Charge.
36Supply and fixing of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by Engr-in-Charge.
37M & L for metal spreading around the two pole structure including cleaning & removing grass of the area 4mx3m approx around the two pole structure. Spreading & leveling sand cushioning 15 mm over the cleaning surface and spreading 40mm graded aggregate over the sand cushioning, paint the concrete surface with lime paint complete all as specified and directed by Engr-in-Charge.
38M&L for complete routine test of transformer of Cap upto 315 KVA (as per IE rules)with authorised agency as per the direction of Engr-in-Charge and submit the all routine test certificate by the authorised agency to Engr-in-Charge for maint of our record of any capacity of trnasformer complete all as directed
39Supply, heating and topping up transformer insulating oil EHV grade having dielectric strength not less than 60 KV (R.M.S) at 2.5 mm gap high viscosity confirming to IS – 335 of 1983 complete for replacement of unserviceable transformer oil or for toping up all as directed.
40Supply & fixing in replacement of breather Assembly for upto 315 KVA Transformer Make : MB Supplier/Pooja industries/Goyal electric works.
41S & F in replacement of .LT bushing with stud, brass terminal 6 Nos.brass nuts and washers, gaskets, insulator etc suitable for upto 315 KVA Transformer complete in all respect & all specified. Please Enable Macros to View BoQ information
42S & F in replacement of .LT bushing with stud, brass terminal 6 Nos.brass nuts and washers, gaskets, insulator etc suitable for upto 315 KVA Transformer complete in all respect & all specified. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57344780
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 22 Lakhs
LAST DATE 24-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair & Maintenance Of External Electric Ug Cables, Lt Panels, Two Pole Structure, Switch Gears, High Mast Lights, Bollard Lights, Emergency Light, Street Light, Flood Light Etc And Other Misc Connected Works At Cgra And Cgae Bhubaneswar Under Ge (I)(Cg) Bhubaneswar
Basic Detail
Tender No 8718/BBSR/04/E8
Bidding Type Tender
Location
City Khordha
State Odisha
Key Dates
Publish Date 03 Sep 2026
Submission Date 24 Sep 2026
Open Date 28 Sep 2026
Finance
Tender Value 22 Lakhs
Tender Fee 500
EMD 44000
Exemption Available
Document List
98f5d385-c292-443c-bb38-9b09c2666c48.html
BOQ_882915.xls
TENDER.pdf
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Sep 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

98f5d385-c292-443c-bb38-9b09c2666c48.html

xls

BOQ_882915.xls

pdf

TENDER.pdf

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders