Tender For Repair/Maint Of External Water Supply Distribution Lines, Cleaning Oht, Chlorination And Connected Items And Repair/Replacement Of Lt Connected Items For Improvement Of External Elect Supply At 652 Coy Asc (Civ Gt) Imtrat Under Ge(Af) Hasi
Tender Overview
Project Description
Tender for Repair/Maint Of External Water Supply Distribution Lines, Cleaning Oht, Chlorination And Connected Items And Repair/Replacement Of Lt Connected Items For Improvement Of External Elect Supply At 652 Coy Asc (Civ Gt) Imtrat Under Ge(Af) Hasimara
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority:GE (AF) HASIMARA Name of Work : REPAIR/MAINT OF EXTERNAL WATER SUPPLY DISTRIBUTION LINES, CLEANING OHT, CHLORINATION AND CONNECTED ITEMS AND REPAIR/REPLACEMENT OF LT CONNECTED ITEMS FOR IMPROVEMENT OF EXTERNAL ELECT SUPPLY AT 652 COY ASC (CIV GT) IMTRAT UNDER GE(AF) HASIMARA Contract No: GE/HAS/ /2026-27 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE 'A' (BoQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | M & L for construction of valves pit chamber of size 120cm x 120cm x 120cm (internal), 15cm thick PCC foundation using PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate), 25cm thick brick wall, using old size burnt clay brick in CM (1:4), 15mm thick rendering on internal and extranal surfaces both in CM (1:4), PCC (1:2:4) type B1 coping (using 20mm graded crushed stone aggregate) for grouting MS frame including foundation 3mm thick MS top sheet cover with locking arrangement including 50mm pad lock with double key arrangement, MS frame work made out of 40 x 40 x 5mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer incuding necessary excavation in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtrs, complete all as specified and directed. |
| 3 | S&F 100mm dia CI sluice valve, flanged end, class PN 1.6 (IS-14846) with brass spindle and hand wheel including necessary gasket, nuts and bolts, washer etc inculding dismantling of old unserviceable sluice valve, complete all as specified and directed. |
| 4 | S&F 100mm dia non return valve, flanged end, class PN 1.6 (IS-14846) with brass spindle and hand wheel including necessary gasket, nuts and bolts, washer etc inculding dismantling of old unserviceable sluice valve, complete all as specified and directed. |
| 5 | S & F power pack, industrial type,180 AH, 12 Volt, 25 plate, along with copper lead and clamp, complete all as specified and directed |
| 6 | Flushing bore well at site with air compressor of capacity 250PSI/1000 Cum and related accessories not less than 60 hours till water discharge is free from sand and potable water and to achieve maximum discharge capacity, complete all as specified and directed. |
| 7 | S & F in repair fully automatic star delta starter, in sheet steel enclosure type with single phase preventer suitable for submersible pump motor capacity 20 HP, 415 V, 50 Hz, 3 phase, relay range 20 to 32 Amps, complete all as specified and directed. |
| 8 | M & L for attending pipeline breakdown of CI pipe of 80mm dia by making lead joint with lead and spun yarn and moulding clay including taking up/down pipe using chain pulley or rope and testing of pipe line, complete all as specified and directed .Note- Earth work excavation, if required, shall be measured and paid seperately |
| 9 | M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, PCC (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion, complete all as specified and as directed.Note : Proper earthing pit shall be provided with pit cover. |
| 10 | All as per item No 8.00 here-in before but using galvanised iron strip 32 x 6mm as earthing lead and protection pipe of 40mm bore light grade, complete all as specified and directed. |
| 11 | M & L for seven stage cleaning and sterlization of inside overhead tank capacity 25000 gallons through bacterioligical treatment by using TERBAC GS, TERBAC-G-65 and ULTRA VOILET ray, complete all as specified and directed. Process of seven stager are as under :-1. First stage is to draing out the water by using exist valve or high capacity dewatering system.2. Second stage is cleaning all the algae formation inside the tank by using TERBAC G10 a laboratory tested branded chemical of the company and scrubbing the walls of the tanks.3. Third stage is fresh water cleaning by high speed jet pump.4. Fourth stage and first bacteria screening is decertification by using TERBAC-G5 a Govt Laboratory certified brannded halogen compound.5. Fifth stage is cleaning the floor of water tank by industrial vaccum cleaner.6. Sixth stage is the secord bacteria screening and sterilizing method by using ultra voilet ray within the tank and kills all suspended bacteria.7. Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65Note : Company shall submit govermnet laboratory test certificate of TERBAC-G5, TERBAC-G65, fix the sticker mentioning the date of cleaning and name of site and also provide certificate confirming the completion of steriliztion of water tanks metnioning the name of station and date of cleaning. |
| 12 | Supply only calcium based high strenth chlorination chemical (Calcium hypo chlorite) for water disinfection in granular form in factory sealed HDPE container complete generic specification as given below :- (a) Chemical name : Calcium hypochlorite(b) Common name: Stable bleaching powder / high str bleaching powder(c) Toxic & undersireable substance : Should not induced substances beyond acceptable limit as given in IS 10500(2012) in treated and disinfected water. (d) Packing 40-45 kg drums (25 drum @ 45 Kg each)Charaterstic specification:- (a) Available chlorine - Min 65 %(b) Particle size (passing through 1+ .70mm IS) % by mass min 99.5(c) Water insoluble matter, max 6%(d) Calcium Hydroxide, max 4% (e) Sodium chloride, max 15% |
| 13 | Supply only Chlorine Testing Kit with coloured ample complete with all tesing fitments and OT solutions in rexine finish box test of PPM, complete all as specified and directed. |
| 14 | S&F post top lantern LED type 40/42 Watt 230 volt, AC, outdoor type with decorative post top for 360 degree indirect light, with impact and corrosion resistant complete with driver and lamp, IP 65/66 protection, complete all as specified and directed. |
| 15 | S&F in replacement of first aid kit box/emergency medical box wall mouted type made outof powder coated GI sheet of 18 gauge and the size of the box will be 36cm(H) x 26cm(W)x 13 cm(D) with front transparent acrylic glass and multi compartment 4 shelf for betterorganize of medicines with security lock on door, openable window at front side with help of hinge at one side and locking arrangement at another side, openable window must painted with \\"FIRST AID\\" with red paint and whole box will fixed on wall at height not less than 2mtr including medicene and other items as under :-Sterilized dressings(04), Cotton Wool 10 gm (02), Antiseptic Solution 100 ml (01), BurnOintment (01), Scissor (01), Digital Thermometer (01), Disposal Gloves(02), Disposal Mask (20), Adhesive / Microporous Tape 1/2\\" (01), Band- Aid (10), safety pins(05), Sofraxime Cream (01), Roller Bandage (04), First-Aid Guide booklet, Hand Sanitizer (02), Antiseptic cream (01), Antiallergic medicene, Cough medicene, Pain killer, Fever and cold medicene and any other essential medicene, complete all as specified and directed. |
| 16 | Cleaning of area around E/M installation and store yard by scraping the grass and creepers from roof and spraying grass killing chemical with spray gun, as per manufacturer's instructions for prevention of weeds and grass at surrounding of E/M sub station area, complete all as specified and directed.Note : Rate includes removing all waste material and grass not excceding 50 Mtrs distance from installation, depositing where directed at a level not exceeding 1.5 Mtrs above the starting point and cleaning of yard. |
| 17 | S & F 3 core PVC insulated unsheathed multistranded copper conductor cable (FR) of size 1.5 Sqmm for voltage grade upto 1100 V, passing through PVC conduit from junction box to fittings, complete all as specified and directed. |
| 18 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth for foundation, for shafts, wells cesspits, manholes, foundation of pole/stayetc. and n.exc 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed. |
| 19 | Returning filling in incl spreading, leveling watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed. |
| 20 | Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil, complete all as specified and directed. |
| 21 | S&F 50mm dia CPVC pipes SDR-13.5 & plain CPVC SDR 11, fittings in trenches including all necessay fittings, like elbow, tee, socket, reducer, bushings, end caps, end plugs, etc and with CPVC solvents cement including taking out old unserviceable pipe of any description, complete all as specified and directed |
| 22 | S&F 40mm dia CPVC pipes SDR-13.5 & plain CPVC SDR 11, fittings in trenches including all necessay fittings, like elbow, tee, socket, reducer, bushings, end caps, end plugs, etc and with CPVC solvents cement including taking out old unserviceable pipe of any description, complete all as specified and directed |
| 23 | S&F 25mm dia CPVC pipes SDR-13.5 & plain CPVC SDR 11, fittings in trenches including all necessay fittings, like elbow, tee, socket, reducer, bushings, end caps, end plugs, etc and with CPVC solvents cement including taking out old unserviceable pipe of any description, complete all as specified and directed |
| 24 | S&F 50mm dia CPVC ball valve suitable for CPVC pipe and taking down old unserviceble vall valve, complete all as specified and directed. |
| 25 | S&F 40mm dia CPVC ball valve suitable for CPVC pipe and taking down old unserviceble vall valve, complete all as specified and directed. |
| 26 | S&F 25mm dia CPVC ball valve suitable for CPVC pipe and taking down old unserviceble vall valve, complete all as specified and directed. |
| 27 | Supply and laying double walled corrugated (DWC) HDPE duct pipe of 120mm outer dia, heavy duty, conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed. |
| 28 | Supply and laying double walled corrugated (DWC) HDPE duct pipe of 90mm outer dia, heavy duty, conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed. |
| 29 | Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm outer dia, heavy duty, conforming to IS, approved colour complete with fittings for cable protection, complete all as specified and directed. |
| 30 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of cross sectional area 240 Sqmm 3.5 core, complete all as specified and directed.Note : Cable protection pipe/cable cover, etc shall be measured and paid seperately. |
| 31 | All as per item No 29.00 here-in before but cross sectional area 150 Sqmm 3.5 core, complete all as specified and directed. |
| 32 | All as per item No 29.00 here-in before but cross sectional area 70 Sqmm 3.5 core, complete all as specified and directed. |
| 33 | All as per item No 29.00 here-in before but cross sectional area 50 Sqmm 3.5 core, complete all as specified and directed. |
| 34 | All as per item No 29.00 here-in before but cross sectional area 25 Sqmm 4 core, complete all as specified and directed. |
| 35 | All as per item No 29.00 here-in before but cross sectional area 16 Sqmm 4 core, complete all as specified and directed. |
| 36 | S&F in repair MCCB 250 Amps AC 4 pole 415 Volt, 50 Hz, 36 KA breaking capacity, Ics = 100 % Icu as per IS/IEC 60947-2 with thermal magnetic release including providing new thimble / lugs of suitable size and taking down old unserviceable one, complete all as specified and directed. |
| 37 | S&F in repair MCCB 200 Amps AC 4 pole 415 Volt, 50 Hz, 36 KA breaking capacity, Ics = 100 % Icu as per IS/IEC 60947-2 with thermal magnetic release including providing new thimble / lugs of suitable size and taking down old unserviceable one, complete all as specified and directed. |
| 38 | S&F in repair MCCB 100 Amps AC 4 pole 415 Volt, 50 Hz, 36 KA breaking capacity, Ics = 100 % Icu as per IS/IEC 60947-2 with thermal magnetic release including providing new thimble / lugs of suitable size and taking down old unserviceable one, complete all as specified and directed. |
| 39 | M&L steel tubular swaged pole, type 410 SP-31 (9.00 metres long) complete with cast iron base plate, finial taper plug, cap, mild steel bolts, nuts, screws, etc. including applying two coat of black bituminous paint internally and externally up to planting depth and applying with two coats of aluminium painting over a coat of red oxide primer including writing 'MES LT pole No.______' with synthetic enamel paint, complete all as specified and as directed. Note : Earth work and PCC foundation shall be measured and paid separately. |
| 40 | S&F 1.5m long Hot dip galvanised single arm bracket made up of 40mm bore GI pipe, medium grade, bend to shape required, suitable to mount on pole having top 70mm, complete all as specified and directed |
| 41 | M&L for PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in foundation of pole etc including necessary formwork, complete all as specified and directed. |
| 42 | S&F LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, complete all as specified and directed. |
| 43 | S & F junction box made from SMC/FRP sheet ready made size of junction box 200 x140 x 95mm with aluminium bus bar of 50 Amp capacity for RYB and half for neutral made in suitable size fixed inside the junction box with necessary supporting insulators fixed on hylem sheet, MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete , entire assembly fixed to pole /Wall with MS clamp 25 X 5 mm and nuts & bolts, including one MCB SP 6 Amp 10 KA 240 V, with necessary copper lugs for connecting cables from junction box to fittings, complete all as specified and directed. |
| 44 | Supply, installation, testing and commissioning factory fabricated feeder pillar (outdoor type) weather dust and vermin proof fabricated out of 3.15mm thick CRCA steel sheet outer portion AC 415 volts, 50 HZ of size 1200mm x 600mm x 300mm mounted on PCC foundation and inner portion of size 2.0mm thick suitable size of MS channel supports and and with suitable size of angle iron legs for grouting steel sheet powder coated paint internally and externally and locking arrangement including all incoming and outgoing connection with suitable size of lugs and glands dismantling existing unserviceable panel and including the following:-Incoming :-(i) MCCB 200 Amp, 4 pole 36 KA, Ics = 100% Icu with thermal magnetic protection unit-01 No. Outgoing :- (i) MCCB 160 Amp, 4 pole 25 KA, Ics = 100% Icu with thermal magnetic protection unit -01 No.(ii) MCCB 63 Amp, 4 pole 25 KA, Ics = 100% Icu with thermal magnetic protection unit -02 Nos.(iii) Indication lamp for each incoming and outgoing.(iv) Digital Voltmeter -01 No.(v) Digital Ammeter -01 No.(vi) Aluminium busbar 3 phase 4 wire for rating 250 Amps for phase and neutral - 04 Nos. |
| 45 | S&F in repair electronic Timer for 24 hrs , top mounting for all contactors (frame 1 to 4) suitable for street light application, complete all as specified and directed. |
| 46 | S&F in repair GI bracket fixing to street light poles, made out of 50mm bore GI pipe, medium grade, bend to shape including applying two coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed. |
| 47 | S & F in replacement 3 core PVC insulated sheathed multistranded copper conductor cable (FR) of size 2.5 Sqmm passing through PVC conduit from junction box to fittings, complete all as specified and directed.(Note: PVC conduit shall be measured and paid seperately.) |
| 48 | S & F rigid 20mm dia PVC non metalic conduit heavy duty, fixed on pole with necessary bend elbow, couplers, check nuts, saddles etc, complete all as specified and directed. |
| 49 | S & F ON LOAD change over switch 415V in sheet steel enclosure 4 pole of capacity 250 Amps with barrier, handle and door locking kit system and necessary connection between two power sources as per site requirement, complete all as specified and directed. |
| 50 | M&L for painting existing steel tubular poles, 8.5/9.0m long meter in height above GL, including cross arms and bracings, on existing surface after cleaning and removing dust, rust & dirt, applying one coat of red oxide primer and and two coat of synthetic enamel paint (1st grade quality) of required colour shade, after cleaning the pole surfaces mounted on insulator and steel frame with operating mechanism worked including numbering of pole, complete all as specified and directed. |
| 51 | Note: An amount of Rs.40,160.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender