Tender For special Repair To Bar And Chakra Lounge, Dsoi, Addn/Altn To Foyer Area Of Dsom & I And Additional/Alternation To False Ceiling Of Seating Area Near Swimming Pool At Si Lines Under Ge Bhopal
Tender Value
31.12 Lakhs
Estimated cost
Bid Submission
24 Sep 2026
17 days left
EMD
63000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair To Bar And Chakra Lounge, Dsoi, Addn/Altn To Foyer Area Of Dsom & I And Additional/Alternation To False Ceiling Of Seating Area Near Swimming Pool At Si Lines Under Ge Bhopal
BOQ
| Sl. No. | Item Description |
| 1 | Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below.(ii) Amount of Schedule of credit shall be deducted offline |
| 2 | S&F Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre /intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including Dismantling wall and ceiling board (fiber, pulp, insulation etc) or insulation board, slabs, blanket, ant thickness, including cover flats complete all as specified and directed. |
| 3 | S&F 12mm plywood grade BWP, type BB fixed with screws to timber frame work for shelves partition, top and sides including necessary beading,screws,brass SS fittings,adhesive,edge lipping,backing complete all as specified and directed. |
| 4 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removing outside MD land complete all as specified and directed. |
| 5 | M&L for 25mm thick in PCC 1:2:4 type B0 using (12.5mm graded stone aggregate) as in bedding layer for laying in floor as in levelling course complete all as specified and directed. |
| 6 | M&L for any shade vitrified ceramic tiles (of approved shade and design) area of each tiles exc 0.42sqm but not exceeding 1.00sqm as in floors and skirtng, etc. set and jointed in neat cement slurry and pointed with white cement including 15mm thick screed bed in CM (1:6) including dismantling of old tiles complete all as specified and as directed. |
| 7 | S & F of decorative plaster of paris cornice/ moulding of approved design and pattern,not exceeding 15cm projection,cast in approved moulds,fixed with POP slurry and GI nails/screws where req,including making joint finishing smooth,rubbing down,curing and preparing the surface complete all as specified and directed by Engineer-in-charge |
| 8 | M & L for preparation of old plastered surfaces of wall and applying two coats of oil bound distemper over a coat of white cement based putty of 1-2 mm thick complete all as specified and directed. |
| 9 | S&F rolled sections as in main and cross beams,hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates conforming to Fe-410 grade ,complete cutting,drilling,notching,welding/bolting/riveting,hoisting,erection and fixing in position including all necessary angle cleats,cnoncting plates ,nuts,bolts and washers complete all as specified and directed. |
| 10 | M&L for preparation of new steel surfaces over 10cm width or girth of any description and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 11 | Taking down chowkhats or frame with shutters (without taking off shutters from the frame) exc 1.5 sqm but n exc 4sqm each each, complete all as specified and directed. |
| 12 | M&L for preparation of new steel surfaces over 10cm width or girth of any description and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 13 | Providing and fixing 12mm Gypsum board ceiling fixed with GI angle/channel frame work incl GI wire/ mesh, etc in different levels all complete including joints filled with paster of paris, putty including POP work/Cornices and applying two coat of oil bound distemper including Dismantling wall and ceiling boards of any description fixed in any position, any thickness including cover fillets. all as specified and direcetd. |
| 14 | S&F of WPC Louver sheet (of approved color & texture) in seamless wall of minimum 17 mm thickness and 1.5 mm wall thickness fixed in frame with necessary fixing screw and clips or solvent complete all as specified and directed. |
| 15 | S&F 18mm plywood grade BWR, type BB fixed with screws to timber frame work for shelves partition, top and sides including necessary beading,screws,brass SS fittings,adhesive,edge lipping,backing complete all as specified and directed. |
| 16 | S&F 0.9mm thick decorative laminate type 1, of surface finish, colour and pattern as approved, fixed with approved adhesive as per maker's instructions complete all as specified and directed. |
| 17 | Demolition of brickwork or stone /boulder masonry,built in CM including all quions,arches,pillars,etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 18 | Taking down chowkhats or frame with shutters (without taking off shutters from the frame) exc 1.5 sqm but n exc 4sqm each each, complete all as specified and directed. |
| 19 | M&L for complete removal of existing treatment, plastered or unplastered old surfaces of walls, including filling of cracks/holes by crack filler, removing unnecessary nails applying two coats of oil bound distemper over 1-2 mm thick wall care putty complete all as specified and directed. |
| 20 | M&L for preparation of old decorated plastered or unplastered surfaces and applying two coat of white wash on ceiling complete all as specified and directed. |
| 21 | M&L for preparation of old plastered surfaces in walls soffits, facia, chajjas and applying two coat of exterior weather proof water based emulsion over a coat of compatible primer complete all as specified and directed. |
| 22 | S&F in repairs 10 to 12mm thick toughened glass in door, partitions etc similar work etc with stainless steel handle, locking arrangement and with hinges in approved shape and design complete all as specified and directed. |
| 23 | S&F in repairs 8mm thick toughened glass in door, window, partitions etc similar work in approved shape and design complete all as specified and directed. |
| 24 | S&F heavy weight stainless steel hydraulic patch fittings for single leaf having single bolt and single strock of minimum size 190 mm x 70 x 40 mm complete all as specified and directed. |
| 25 | S&F Double action floor door spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed to toughened glass door complete all as specified and directed. |
| 26 | S&F stainless steel heavy duty D-shaped patch lock and strike plated two set of keys suitable for double shutter door to be operated from both sides fixed to 12 mm thick glass door complete all as specified and directed. |
| 27 | S&F heavy duty stainless steel (grade 304) H shaped handles 300 mm long fixed to toughened glass door with one pair of collar and screws complete all as specified and directed. |
| 28 | S&F Providing and fixing factory made UPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories. Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.) Area exceeding 2.00 sqm each window complete all as specified and directed. |
| 29 | S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplescomplete all as specified and directed. |
| 30 | M&L in repair 25mm Stainless Steel Drepary curtain rod decorative type incl curtain fancy type including bracket & nobs complete all as specified and directed. |
| 31 | M&L brick work with fly ash bricks, straight or curved on plan to any radius in half brick thick walls using modular bricks build in CM 1:4 all as specified and directed. |
| 32 | M&L for rendering 15 mm thick on new brick work or concrete surfaces or surface of fair faces of brick work in cement plaster 1:6, finished even and smooth w/o using extra cement all as specified and directed. |
| 33 | M & L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of white cement based putty of 1-2 mm thick complete all as specified and directed. |
| 34 | M&L for 18-20mm Granite work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking plat forms and like in cement mortar (1:4) including point ing in white cement (1:2) us ing marble dust with admix ture of pigment to match with shade of granite complete all as specified and directed. |
| 35 | Taking down carefully copper/aluminium point wiring concealed/ casing caping (light, fan, socket or power) including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings, call bell and removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc all as specified and directed. |
| 36 | Dismantling/taking down of unserviceable old existing service /submain wire of any size all as specified and directed |
| 37 | Dismantling/taking down of unserviceable distribution boards with MCBs all as specified and directed. |
| 38 | Taking down LED circular/square panel ceiling lights any type and deposited to SI Lines E/M store yard safely without any damage and in working condition all as specified and directed. |
| 39 | Taking down any type ceiling fan and deposited to SI Line E/M store yard safely without any damage all as specified and ditrcted . |
| 40 | Taking down decorative hanging light without any damage and deposited to user store room and refixing all as specified and directed. |
| 41 | Taking down carefully 1.5/2 TR ACs any type of any size from its position with all precaution , and refixing on its original position in fully serviceable condition by gas charging & petty repairing properly up to fully satisfaction of Engr in Charge all as specified and directed. |
| 42 | M&L for concealed point wiring for one light/one fan/one exhaust fan controlled by one switch complete with and including single core PVC insulated unsheathed FRLS copper conductor 1.5 sqmm cable as per IS 694:2010 ISI marked annealed multistranded copper conductor drawn through and including medium grade PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20mm noninal size including modular / non modular type all accessories/fitting / metal flush box / cover plate/junctiion boxes/ inspection cover etc ISI marked and sunk terminal boxes flush galvanised metal boxes with addtional single core PVC insulated unsheathed FRLS copper conductor 1.5 sqmm multistarands cable as continious earth wire connected to metalic body at one end and common earth dolly to other end including cost of cutting chase and making good to distrubed surfaces of wall with cement mortor 1: 3 including necessary plaster and poiinting in cement mortor 1:3 with white wash / distemper/ other painting complete all as specifiecd and as directed.Note:- cost of cutting chase and making good shall be included in the quated rates) |
| 43 | All as per Srl item No. 41.00 here in before but for socket outlet 5/6 amp on independent board complete all as specified and directed. |
| 44 | All as per Srl item No. 41.00 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed. |
| 45 | All as per Srl item No. 41.00 here in before but for one socket outlet 3 pin 5/ 15 Amps on independent board with wire of size 2.5 Sqmm complete all as specified and directed. |
| 46 | S & F modular switch one way 6 Amp one module, 240 volts ISI marked complete all as specified and directed. |
| 47 | Supply and fixing modular socket outlet 2-in-1, 2/3 pin, 6 Amps, 240 volts,ISI marked controlled by one switch complete all as specified and directed. |
| 48 | S&F modular switch one way 16 Amp one module, 240 volts ISI marked complete all as specified and directed. |
| 49 | Supply and fixing modular socket outlet 2-in-1, 2/3 pin, 6/16 Amps, 240 volts, ISI marked controlled by one switch complete all as specified and directed. |
| 50 | S&F modular ceiling rose 3 terminals 65x25 mm dia poly carbonate ISI marked all as specified and directed. |
| 51 | S & F in replacement modular stepped type electronic fan regulator single / double module compatable with BLDC fan complete all as specified and directed. |
| 52 | Supply and fix of LED slim square/circular panel light fitting for surface ceiling light 15 watt, colour warm including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed. |
| 53 | Supply & Fix Recess mounted downlighter with pressure die-cast aluminium heat sink & clear PC as a cover in white powder coated finish with Independent electronic LED driver. mounting COB Spot LED light round warm in colour with excellent thermally managed luminaire 9 watt , 220V AC with high efficiency PMMA diffuser soft glare free light suitable for roof ceiling including connecting up with driver three core flexible coppder conductor cases of suitable size complete all as specified and directed. |
| 54 | Supply & fixing decorative wall light, gold finish fixture with white glass diffuser single Arm Brown Metal Wall Light colour- Metal (Black Antique) Glass (White) Cap Type: suitable for E27 Holder to fit LED bulb & Maximum Wattage Support : Upto 40W- Voltage : 220V.design:- Versatile & Stylish design with modern fittings & Metal frame. incl 9 W warm LED bulb suitable for Bedroom, Living room etc. complete all as specified and directed. |
| 55 | Supply and fixing of 3W warm decorative wall step led foot light & Input Voltage: Typically 160V-280V AC, suitable for standard household voltage. Light Source: SMD LED or Epistar LED chips.Color Temperature: 3000K (Warm White) is standard for cozy, non-glare illumination.Luminous Flux: Approximately 100 lumens for a 3W model. IP Rating (Waterproofing): Generally IP64 or IP65, indicating dust-tight and protection against water jets (suitable for indoor/outdoor use).Material: Die-cast aluminum body (powder-coated, anti-corrosion) with a polycarbonate diffuser.Lifespan: Often up to 50,000 burning hours.Dimensions: Common sizes include compact 45 x 84 x 84 mm, 8x8x4 cm, or 94x70x40 mm.Mounting: Recessed (with a plastic mounting box) or surface-mounted all as specified and directed |
| 56 | S& F of flexible LED Strip uses high brightness SMD LED as the light source for indoor application luminare 24 watt, 220 V AC with high effeciency light complete with driver , holder and LED Lamp suitable for roof , ceiling including connecting up with 3 core flexible copper conductor cable of suitable size complete all as sfecified and as directed.Make hevvels cat part no LHEHDLPFUN1W024(Flexion Neo LED Strip 24 W of anycolour)or eluivalent Bajaj/C&G/Phillips/as approved by GE. |
| 57 | Supply and fixing of 6W warm white decorative wall led lighgt 2 way K type light & Input Voltage: Typically 160V-280V AC, suitable for standard household voltage. Light Source: SMD LED or Epistar LED chips.Color Temperature: 3000K (Warm White) is standard for cozy, non-glare illumination.Luminous IP Rating (Waterproofing): IP65, indicating dust-tight and protection against water jets (suitable for indoor/outdoor use).Material: Die-cast aluminum body (powder-coated, anti-corrosion) with a polycarbonate diffuser. Lifespan: Often up to 50,000 burning hours all as specified and directed. |
| 58 | Supply and fixing in replacement factory made epoxy powder coated Distribution Board TP & N 4 ways ( VTPN MCCB DB ) and space for MCCB as incomer, with metal door ( IP-43 protection ) fabricated from CRCA sheet and fixed semi flush to wall and suitable for universal mounting and including isolated Neutral Bar, Insulated busbar assembly, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified and directed.NOTE:- MCCB shall be measured and paid seperatly. |
| 59 | S&F in replacement MCCB 100 Amp, 3 Pole, breaking capacity 36 KA with complete electrical connections by appropriate size of copper lugs, complete all as specified and directed. |
| 60 | S&F in repair sheet metal enclosure for MCB, DB, TPN, 415 Volts, 200 amps rated busbar, 4 way, Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 54 including wooden rectangle board of first class hardwood of suitable size for mounting of DB box complete all as specified and as directed. NOTE:- MCB shall be measured and paid seperatly. |
| 61 | Supply and fix modular combo AC box (including socket ,plug top and 25 Amp MCB's) 240 V,50 Hz an ISI-marked, impact-resistant body and Built with high-impact polycarbonate materials that offer high softening temperatures, ensuring long-lasting performance complete all as specified and directed . |
| 62 | Supply and fixing ceiling fans brown in colour complete with blades, down rods, and accessories, 230 V, 1200 mm sweep. Min air delivery 220-230 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) without remote controller complete all as specified and as directed. |
| 63 | S & F in replacement MCB SP suitable for 240 volts, AC supply 6 to 32 Amps , with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed. |
| 64 | S&F in repair MCB TPN suitable for 240 volts, 'B' curve,AC supply 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA, complete all as specified and directed. |
| 65 | S&F in repair MCB TP suitable for 240 volts, 'B' curve,AC supply 63 Amps, with over load and short circuit protection and rupturing capacity not less than 10KA, complete all as specified and directed. |
| 66 | M&L for sub main wiring with approved colour coding as per IS with single core PVC insulated FRLS cable 1100V unsheathed 3 wires, (2 for phase and neutral and one for earth) with stranded copper conductor of 4.0 sqmm nominal cross section area,and drawing into 20mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples, lock outs, etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 complete all as specified and directed. Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Two runs of 4.0 sqmm cable for phase and neutral ansd one run of 4.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length. |
| 67 | M&L for sub main wiring (Three phase) with approved colour coding as per IS with single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 10.0 sqmm 6 wires (three for phase one for neutral and one for earth) drawn into 25 mm external diameter rigid non metallic PVC conduit, ISI marked, medium grade with its accessories, inclusive of all fittings such as tees, bends, junction boxes, elbows, saddles, pipe hooks, couples etc. in concealed wiring system by cutting of walls (brick or stone) and making good disturbed surface of wall in CM 1:3 and complete all as specified and directed. Note : (i)Wiring to be done as per approved colour code in IE rule. (ii) Four runs of 10.0 sqmm cable for phase and neutral,two runs of 10.0 sqmm cable of earth continuity conductor & PVC conduit pipe shall be measured as one unit length. |
| 68 | S&F in replacement of building security light fitting complete with 36 watt,IK 07 LED type pressure die cast aluminium housing and heat resistant toughened glass with frame protection (IP 66 protection) and better optics for uniform distribution complete fixed bracket made out of GI pipe 32 mm dia (light grade) 1.5 metre long and MS clamp and nut bolts washers and connected with twin core cable 1.5 sqmm from ceiling rose to fittings connector all as specified and directed. |
| 69 | M&L in replacement of earthing complete with galvanised steel earth plate electrode size 600X600X6mm thick burried directly in ground vertically to a depth not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m deep below normal ground level and connected to and including GI earth lead wire 4mm dia by means of bolts, nuts, check nuts & washers of galvanised iron and connected to test point all as shown in electrical plate No 3 of SSR part I-2009 and all as specified or indicated and testing on completion including excavation and earth work in any type of strata available at site, PCC (1:3:6) type C-1 earthing chamber, pre cast RCC slab 50 mm thick in cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregate reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm funnel with GI watering pipe of 20 mm bore medium grade, wire mesh and lugs, GI protection pipe of 15 mm bore light grade up to 7.5 metre long all as specified and directed. NOTE :- GI earth wire and protection pipe beyond 7.5 metre will be measured and paid separately. |
| 70 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable and getting out in hard/dense soil complete all as specified and directed. |
| 71 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed |
| 72 | Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 73 | M&L local sand dry, filling in trenches around under ground cable complete all as specified and directed. |
| 74 | M&L for providing of un-reinforced precast concrete cable cover class LV, Type 1 size 250mmx 150mm x 40mm laid flat dry for protection of under ground cable complete all as specified and directed. |
| 75 | Excavation in trenches n. exc. 1.5 mtr in wide and n. exc. 1.5 mtr in depth for laying of underground cable pipe and getting out in soft disintegrated rock all as specified and directed. |
| 76 | M & L for making good the disturbed surface by filling PCC 1:2:4 type B-1 using 20 mm graded course aggregate to match with existing surfaces all as specified and directed. |
| 77 | Removing of excavted soft disintegrated rock to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 78 | Supply, laying & testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 50 sqmm 3.5 core all as specified and directed. Note:- Excavation & earth work and pipe / sand / bricks for cable protection shall be measured and paid for separately under appropriate item of this schedule) |
| 79 | M & L GI Tubing \\"light grade\\" galvanized for protection LT Cable all as specified of size 40 mm bore complete all as specified and directed. |
| 80 | Deduct Schedule of credit (calculation will be done off line) Rs.20569.00 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 24, 2026
17:00 IST