Project Description

Tender for Repair To Summer/ Winter Appliances Alongwith Connected Items At Jutogh, Sanjauli, Kufri, Shimla, Kelvin Grove And Chail Under Ge (I) Jutogh

BOQ

Name of Work:- REPAIR TO SUMMER/ WINTER APPLIANCES ALONGWITH CONNECTED ITEMS AT JUTOGH, SANJAULI, KUFRI, SHIMLA, KELVIN GROVE AND CHAIL UNDER GE (I) JUTOGH
Sl. No. Item Description
1M&L for dismantling Geyser of 25/ 35 Ltr capacity of any type from exiting position for descaling, removing its accessories removing the scale (white presipated) deposited in it, cleaning the inner tank properly, painting with sparay gun and re-assembling the same and refixing to its existing location or new location with testing for its proper functioning complete all as specified and directed. Note: If any spares required then supplied and measured separately under relevant item.
2All as per Srl item No 1.00 above but for 50/100 Ltr Capacity complete all as specified and directed.
3M&L for painting of geyser of upto 100 Ltr capacity, cleaning and preparing the outer surface by rubbing down, removing rust, loose paint and other foreign matter, applying one coat of approved metal primer and spray painting the outer body with two coats of approved synthetic enamel paint by spray gun to match the existing shade, including drying, complete all as specified and directed. Note: This item is limited to painting of the external body of the geyser only. Any repairs, servicing, descaling, replacement of parts or internal maintenance shall be measured and paid separately.
4Supply, fixing and replacement of inner tank of existing storage geyser 25 ltrs capacity of approved make and matching capacity including taking down of defective tank, necessary accessories, testing and commissioning, complete all as specified and directed.
5All as per Srl item No. 4.00 above but for 50 Ltr Capacity complete all as specified and directed.
6All as per Srl item No. 4.00 above but for 100 Ltr Capacity complete all as specified and directed.
7S&F in repair thermostat 0-80 Degree as per exiting size including taking down of defective thermostat complete all as specified and directed.
8S&F of heating element 1000/ 1500 watt with studs, bolts, rubber washer suitable for existing type (triangular/ round) of geyser including taking out of old unserviceable element complete all as specifed and directed. Make : Bajaj/ Racold/ Venus or equivalent as approved.
9All as per Srl item No 8.00 above but for 2000 watt, complete all as specified and directed.
10S&F in repair Indicator lamp with flexibe copper wire of suitable size Red/ Green including taking down of defective indicator lamp, complete all as specified and directed.
11S&F stainless Steel grade chromium finish connection pipe 15 mm dia with adopter, washer 450 mm long including making in shape complete all as specified and directed.
12S&F PVC connection pipe, 15mm dia, 450mm long (2 Nos), suitable for cold and hot water connection of electric storage geyser, including necessary fittings, washers, PTFE tape, lighting, leakage testing and commissioning, complete all as specified and directed.
13S&F brass Non-Return Valve (NRV) suitable for hot/ cold water line of electric storage geyser, including dismantling of faulty valve if any providing threaded fittings, sealing with PTFE tape, testing for leakage and commissioning, complete all as specified and directed.
14S&F stainless steel aperture plate (6/9 hole) suitable for 25/35 litre electric storage geyser, including rubber gasket, nuts, bolts, washers, sealing arrangement, dismantling and taking down of defective aperture plate, refixing of connections, testing for leakage and commissioning, complete all as specified and directed.
15S&F complete geyser top assembly comprising stainless steel aperture plate (6/9 hole) suitable for 25/35/50/100 litre electric storage geyser, along with immersion heating element, thermostat, indicator lamp, rubber gasket set, nuts, bolts, wiring connection, sealing arrangement, dismantling of existing defective assembly, refixing, testing for leakage, electrical testing and commissioning complete all as specified and directed.
16S&F to walls , floor and ceiling 25 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 with and including taking down existing unserviceable complete all as specified and as directed.
17All as per Srl item No.16.00 above but for size 20 mm bore complete all as specified and directed.
18All as per Srl item No.16.00 above but for size 15 mm bore complete all as specified and directed.
19S&F stop valves, 20mm cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
20All as per Srl item No 19.00 above but for fancy type, chromium plated with long shank and cup (concealed type) complete all as specified and as directed.
21S&F 15mm bore gun-metal, globe or gate valves, with iron wheelhead, screwed both ends for ironpipe and fixed complete all as specified and directed.
22All as per Srl item No. 21.00 above but of size 20 mm bore complete all as specified and directed.
23All as per srl item No. 21.00 above before but of size 25mm bore complete all as specified and directed.
24S&F plug top, 3 pin, 15 Amp, 230 volts, complete all as specified and directed.
25Supply, installation, testing and commissioning of new electric storage water geyser of 25 litre capacity, including fixing on wall with suitable fasteners, making inlet/outlet water connections, electrical connection with plug top, testing for leakage, heating performance, and commissioning complete all as specified and directed
26All as per Srl item No. 25.00 above but for 35 Ltr capacity, complete all as specified and directed.
27All as per Srl item No. 25.00 above but for 50 Ltr capacity, complete all as specified and directed.
28All as per Srl item No. 25.00 above but for 100 Ltr capacity, complete all as specified and directed.
29S&F in PVC insulated and sheathed 3 core copper conductor cable of size 2.5 Sqmm 3 core suitable for geyser complete all as specified and directed.
30S&F MCB SP (single pole) 06 to 32 Amps, 'B' Curve, with 10 kA for inductive load connected through cable lugs of suitable size complete all as specified and directed. Make: L&T/ Legrand/ Schneider or equivalent as approved.
31S&F fastner for fixing of gyeser in existing wall, suitable size minimun 4 \\" (02 Nos) complete all as specified and directed.
32M&L for point wiring 1.5 Sqmm (nominal cross sectional area) with colour coding multistranded copper conductor cable, PVC insulated (FRLS-H) and unsheathed cable and including drawn through PVC casing – capping size of 25x32 mm wiring with all fittings and accessories, terminated to sunken box and laminated sheet of suitable size for housing/mounting the switches/sockets including 1.5 Sqmm PVC insulated unsheathed multistranded copper conductor cable earth wire connected to common earth dolly for one point on independent board control by one, one way switch 5 Amps, complete all as specified and directed.
33All as per Srl item No 32.00 above but for one 3 pin 15 Amps power point on independent board with 2.5 Sqmm complete all as specified and directed
34S&F switch piano flush single pole, one way 5 Amp ( ISI marked) complete all as specified and directed.
35S & F switch piano flush single pole, one way 15 Amp ( ISI marked) complete all as specified and directed.
36S&F socket (ISI Marked) 2 in 1, 3 pin 5/6 amps flush type complete all as specified and directed.
37S&F socket 2 in 1, 5 pin 5 and 15 amps (ISI marked) flush type universal, complete all as specified and directed.
38M&L for rewinding/ repairing of blower fan motor of water cooler by disconnecting the electrical connection of burnt out electric outdoor motor of any make/model incl transportation to and for, taking out burnt out winding carefully and rewinding with high quality super enamelled copper wire of existing gauge & size including insulating material and varnish, bush, shaft, bearing etc complete for motor of suitable capacity including removal and re-fixing of the same complete all as specified and dierected.Make of motor to be repaired as per sample.
39S&F in repair Compressor for Split AC 2 TR as per sample including taking down of defective compressor complete all as specified and directed.
40Supply & charging R-32 /22 gas for AC etc and other appliances (including Cylinder 5 KG) complete all as specified and directed.
41Supply & charging R-410 gas for refrigerator /Deep Freezer /etc and other appliances (including Cylinder 5 KG), complete all as specified and directed.
42Supply & charging R-134a gas for water cooler and other appliances complete all as specified and directed.
43S&F in repair starting Capacitor of capacity suitable existing size ±5%, 220V, AC, 50 Hz including taking down of defective capacitor complete all as specified and directed. Make : - GC / Universal / Havells / Epcos / Tibcon or equivalent as approved.
44S&F in repair starting Capacitor of capacity suitable existing size ±5%,, 220V, AC, 50 Hz including taking down of defective capacitor complete all as specified and directed. Make : - GC / Universal / Havells / Epcos / Tibcon or equivalent as approved.
45S&F in repair Copper refrigerent piping size 1/4\\" or 3/8\\" suitable for cooling appliances including taking down complete all as specified and directed.
46S&F in repair Copper refrigerent piping size 1/2 or 5/8\\" suitable for cooling appliances including taking down complete all as specified and directed.
47S&F in repair V-Belt, B-63, suitble for cooling appliances including taking down, complete all as specified and directed.
48S&F in repair Compressor for water cooler as per sample including taking down of defective compressor complete all as specified and directed.
49S&F in repair motor assembly of 230 V, 50 HZ,(as per existing), as per sample suitable for Water cooler of any make and capacity complete all as specified and directed.
50S&F in repair Capacitor suitable for water coolers aluminium body, 440V, AC, 50 Hz including taking down of defective capacitor complete all as specified and directed. Make : - GC / Universal / Havells / Epcos / Tibcon or equivalent as approved.
51S&F in repair Compressor suitable for refrigerator 1/6 or 1/8 including taking down of defective compressor complete all as specified and directed.
52S&F in repair PCB for suitable refrigerator of any make / capacity including taking down of defective PCB complete all as specified and directed.
53S&F in repair Condenser coil suitable for Refrigerator of any make and capacity: including taking down of defective coil complete all as specified and directed.
54S&F in repair Cooling coil with door and frame suitable for Refrigerator of any make and capacity including taking down of defective cooling coil complete all as specified and directed.
55S&F in repair Thermostat switches suitable for Refrigerator of any make and capacityincluding taking down of defectivethermostat complete all as specified and directed.
56S&F in repair Compressor suitable for Deep freezer including taking down of defective compressor complete all as specified and directed.
57S&F in repair Deep freezer capacity of any make and capacity including taking down of defective condenser complete all as specified and directed.
58S&F in repair of PCB Kit AC/Refrigerator/ Deepfreezer etc after recitfication of PCB the same to be fix properly including making working condition complete all as specified and directed.
59Comprehensive maintenance of AC/water cooler, Refrigertor & Deepfreezer, etc and repair including checking all parts and renewal / replacement of minor defective parts, Servicing and checking of fan motor, Compressor Oil Charging, Suction, liquid Line, nitile rubber, Insulation, Insulation Tape Wrapping with tie, Drier Change, Gas Charging complete all as specified and directed.
60Comprehensive maintenance of walk-in cold storage and repair including checking all parts and renewal / replacement of minor defective parts, Servicing and checking of fan motor, Compressor Oil Charging, Suction, liquid Line, nitile rubber, Insulation, Insulation Tape Wrapping with tie, Drier Change, Gas Charging complete all as specified and directed.
61M&L for Heat pillar any type 1500W high efficiency heating device with a chrome plated outer body and voltage of 220-230 V AC 50 Hz including 2 heating rod and oscillation speed of 5 8 pm complete all as specifed and directed
62S&F in repair heating rod 2 Nos suitable for heat pillar as existing type complete all as specified and directed.
63S&F in repair oscilation fan with motor suitable for heat pillar as existing type complete all as specified and directed.
64S&F in repair switch unit 3 Nos suitable for heat pillar as existing type complete all as specified and directed.
65S&F in repair Body with base plate including guard suitable for heat pillar as existing type complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57344722
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 27.98 Lakhs
LAST DATE 24-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair To Summer/ Winter Appliances Alongwith Connected Items At Jutogh, Sanjauli, Kufri, Shimla, Kelvin Grove And Chail Under Ge (I) Jutogh
Basic Detail
Tender No GE(I)/JUT-77 OF 2026-27
Bidding Type Tender
Location
City Shimla
State Himachal Pradesh
Key Dates
Publish Date 03 Sep 2026
Submission Date 24 Sep 2026
Open Date 26 Sep 2026
Finance
Tender Value 27.98 Lakhs
Tender Fee 500
EMD 55960
Exemption Available
Document List
BOQ_882825.xls
fd094a11-6fb1-457f-8edd-0084cc331c83.html
ResidualworkloadFormat.pdf
Td.pdf
Tendernotice_1 (9).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Sep 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_882825.xls

html

fd094a11-6fb1-457f-8edd-0084cc331c83.html

pdf

ResidualworkloadFormat.pdf

pdf

Td.pdf

pdf

Tendernotice_1 (9).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders