Tender for special Repair To Fire Sec Building Accts Dsc Complex And Addn Altn To Domestic Lpg Gas Cylinder Stores At Air Force Stn Samana
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully any aluminum /copper point wiring (light, fan, socket or power) complete including conduits/casing caping including fixture and fittings such as switches, ceiling rose pendants, regulator sockets etc., removing material/debris for taking credit and making good the disturbed surface of wallSupply & Fixingloors etc., to match with the original existing finish, complete all as specified and directed by Engineer-in-Charge. |
| 2 | Taking down carefully sub main wiring complete of any type (batten / surface conduit) complete and making good disturbed surfaces, complete all as specified and directed by Engineer-in-Charge. |
| 3 | Taking down carefully by unscrewing from fitting and fixtures as switches, ceiling roses, pendents, regulators, bells, sockets, tube light fittings, DB, MCB etc., complete all as specified and directed by Engineer-in-Charge. |
| 4 | Material & Labour for point wiring complete with 1.5 sqmm single core multistranded copper conductor FRLS, PVC insulated and unsheathed cable 650 /1100 volts grade drawn through & including super deluxe casing caping (not less than 25mm wide) with all its accessories like bends, tees, suitable module PVC boxes etc fix on wall or ceiling surfaces all as specified including 1.5 sqmm , FRLS type , copper multistranded cable as earth wire and plastic laminated PVC box with cover plate as specified and directed by Engr -in charge: |
| 5 | One light / fan / exhaust fan point controlled by one, one way switch. |
| 6 | One 3 pin socket out let 5 Amps on same board with other switches. |
| 7 | One 3 pin socket out let 5 Amps on the independent board. |
| 8 | -Ditto- all as per above but with 2.5 sqmm multistranded copper multistranded conductor FRLS cable with 2.5 sqmm earth wire for one 6 pin socket outlet 15 amps on independent board, complete all as specified and directed by Engineer-in-Charge. |
| 9 | -Ditto- all as per item No 4 about but with 4.0 sqmm multistranded copper multistranded conductor FRLS cable with 4 sqmm earth wire for one 6 pin socket outlet 15 amps on independent board, complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply & Fixing switch Piano 5/6 Amps, flush button type, SP, one way, 230 Volts, complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply & Fixing Switch socket combination multipurpose 5 pin 5 Amps, flush type, 230 / 250 Volts, complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply & Fixing switch socket combination ,6 pin, 15 amps, flush type, multipurpose, 230 / 250 volts, complete all as specified and directed by Engineer-in-Charge. |
| 13 | Material & Labour for Ceiling rose, 3 terminal polycarbonate body 6 Amps, 250 volts AC, including connecting, complete all as specified and directed by Engineer-in-Charge. |
| 14 | Material & Labour for sub main wiring with two single core PVC insulated and unsheathed cable 6.0 sqmm with multi stranded copper conductor, FRLS type cable drawn through and including casing and caping complete with all accessories alongwith provn of 6.0 sqmm PVC insulated and unsheathed, multi stranded copper conductor, FRLS type cable as earth wire and connecting to tbe BD with proper size of lugs/thimbles etc., complete all as specified and directed by Engineer-in-Charge. |
| 15 | Supply and fixing of sheet metal enclosure MCB DB, single pole and neutral, 8 ways double door 240 volts having 200 Amps rated bus bar with balnking plates wherever required and degree of protection I.P 43 -IK 09 with acrylic cover as including all connections, complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply and fixing MCB single pole 240 volts 6 to 32 Amps (to be fixed as per load requirement) 220V with 'C' curve complete as including all connections, complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply and fixing MCB Single pole Neutral 240 volts 40- 63 Amps (to be fixed as per load requirement) 220V with 'C' curve complete as including all connections, complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply and fixing stepped type electronic fan regulator flush type, 230 V, including connecting, complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply & Fixing energy efficient LED tube light fitting with built in LED & integral LED driver 20 watt, channel housing & diffuser of length 1200mm (approx) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting, complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply and fixing Energy efficient recessed mounted LED luminaries 36 watt suitable for 600mm x 600mm grid ceiling along with flat diffuser along with constant current electronic driver, complete all as specified and directed by Engineer-in-Charge. |
| 21 | Taking down Ceilling fan/exhaust fan with cover plate, rod, sealing cable end, dismantling blades and removing fan and blad for painting of ceiling fan/Exhaust fan complete with synthetic enamel paint black/ white by spraying machine including filling of cavities with filler, one coat after cleaning all rust and dust etc., complete and refixing the same with 0.5 sqmm, three core flexible wire, copper conductor cable, complete all as specified and directed by Engineer-in-Charge. |
| 22 | Material and labour for earthing in replacement complete with galvanized iron earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel wire 4mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20mm bore, galvanised iron, light grade, and 15mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B-1 for precast chamber cover 50mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion, complete all as specified and directed by Engineer-in-Charge. |
| 23 | Disconnecting and Taking down carefully Celing fan with down rod canopy blades etc and deposit to store and refixing it in same position with 0.5 Sqmm PVC cable and connecting it to the ceiling rose, complete all as specified and directed by Engineer-in-Charge. |
| 24 | Supply & Fixing in replacement of LED flood Light fitting 100 Watt, system efficiency not less than 100 lumen / watt, IP 66 protection, IK 07 impact resistance, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on bracket & connecting, complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply & Fixing energy efficient LED tube light fitting integrated batten type with built in LED Chip & integral LED driver 18 to 20 watt, channel housing & diffuser of length 1200mm (approx.) with all accessories, fixing arrangement internally pre-wired, fixed in position & connecting, complete all as specified and directed by Engineer-in-Charge. |
| 26 | Disconnecting & Taking out LT underground cable (aluminum / copper conductor of size 6-25 sqmm any core from trenches including cable cover, tubes if any etc., complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply and laying XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor 1100 volt grade of size 10 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing, complete all as specified and directed by Engineer-in-Charge. |
| 28 | Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc, not exceeding 10 Sqm on plan area and getting out in soft / loose soil, complete all as specified and directed by Engineer-in-Charge. |
| 29 | Returning, filling in including spreading levelling watering and well ramming in layer not exceeding 25 cm thick using excavated soil, complete all as specified and directed by Engineer-in-Charge. |
| 30 | Removing excavated soil to a distance not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, complete all as specified and directed by Engineer-in-Charge. |
| 31 | Supply and filling Local sand cushioning, with dry and clean sand, over and under the under ground cables in trenches, ducts for cable protection including consolidation, 80mm thick to the authorized width as per SSR–Part-I before laying of cable and 150mm thick after laying of cable, complete all as specified and directed by Engineer-in-Charge.NOTE :- Punned thickness of sand will be measured and paid. |
| 32 | Supplying & laying factory made unreinforced precast cable cover LV type 1 flat of size 250 x150 x 40 mm, complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply and laying GI tubing light grade 40mm bore with all necessary fittings laid in trenches, under road crossing, in floors or fixed to poles / DB for cable protection etc., complete all as specified and directed by Engineer-in-Charge. |
| 34 | Material & Labour for complete removal of existing treatment of any thickness laid over RCC/Roof chajja cleaning and washing of roof with water to remove dust etc as preparation to receive treatment, brooming down or steel wire brushing, scraping down smoke soot, mouls, moss and efflorescent salts and treating oil and greasy spots, complete all as specified and directed by Engineer-in-Charge. |
| 35 | Material & Labour for PCC in roof pading, coving, filling and mass concrete 1:3:6 type C-1, (using 20mm graded stone aggregate), complete all as specified and directed by Engineer-in-Charge. |
| 36 | Material & Labour for plastering/screed 10mm thick on concrete surface in Cement Mortar 1:4, finishing the surface even and smooth without using extra cement, including mixing only liquid water proofing compound as per manufacture instruction, complete all as specified and directed by Engineer-in-Charge.Note:- WPC will be measured & paid separately. |
| 37 | Supply only integral water proofing chemical @ 200ml/Bag of cement, complete all as specified and directed by Engineer-in-Charge. |
| 38 | Material and labour for water proofing treatment by applying one coat of oil base bituminous primer @ 0.3 Kg / Sqm with brush / roller, laying of 3 mm thick APP based polymer modified membrane (mineral finish) reinforced non-woven polyester, weight not less than 3.50 Kg / Sqm and sealing all the over laps 150 mm in length side and 100 mm in width side of membranes laid with torch application, complete all as specified and directed by Engineer-in-Charge. |
| 39 | Taking down cement plaster of any thickness in cement or cement lime mortar on brick or stone or concrete walls etc. including raking out joints, hacking for key, scrubbing down with water etc, including removal of debries to a distance exc 1.5 km but n.exc 2 Km, complete all as specified and directed by Engineer-in-Charge. |
| 40 | Material & Labour for rendering 15mm thick on stone masonary or concrete surface of walls in cement mortar 1:6 finished, complete all as specified and directed by Engineer-in-Charge. |
| 41 | Material & Labour for preparation of newly plastered wall surface and applying 2mm thick wall care putty for making smooth surface and applying two coat of oil bound distemper, complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 42 | Material & Labour for preparation of newly plastered wall surface and applying 2mm thick wall care putty for making smooth surface and applying two coat of oil bound distemper, complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysSep 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender