Tender For Repair And Maintenance Security/Street Light Fitting, Stand By Dg Sets, Timer Switch, Street Light Panels, Service Connections, Earthing And Repair, Maintenance & Replacement Of Apfc Panel, Distribution Panel, Mccb, Change Over Switch, Ear
Tender Overview
Project Description
Tender for Repair And Maintenance Security/Street Light Fitting, Stand By Dg Sets, Timer Switch, Street Light Panels, Service Connections, Earthing And Repair, Maintenance & Replacement Of Apfc Panel, Distribution Panel, Mccb, Change Over Switch, Earthing & Other Connected Electrical Works At Charri C And Dharamshala Mil Stn Under Ge Pal Ur
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-Sep-2026 | Amendment | Other | 24-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Excavating in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth: for foundation, etc. or for shafts, wells, cesspools, manholes, pier holes, etc. n exc 10 sq m on plan and n.exc 1.5 m in depth and getting out in hard/dense soil.complete all as specified and as directed. |
| 2 | All as per Srl No 1 above but depth exceeding 1.5 metre but not exceeding 3.0 metre complete all as specified and as directed. |
| 3 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm.complete all as specified and as directed. |
| 4 | Removal of excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m high from the starting point.complete all as specified and as directed. |
| 5 | Sand cushioning to underground cables complete all as specified in clause 19.75 of SSR Part laid before and after laying and testing of cables.complete all as specified and as directed. |
| 6 | Material and labour for sub class ('B' brick, old size, brick covering laid dry, flat transversely along the length of cable on sand cushioning, with width equal to the length of the brick complete all as specified and directed. |
| 7 | Supply & replacement of existing unserviceable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volt grade of crosssectional area 25 Sqmm 3.5 Core. |
| 8 | All as per Srl No 7 above but of size 16 Sqmm 4 core |
| 9 | All as per Srl No 7 above but of size 16 Sqmm 2 core |
| 10 | All as per Srl No 7 above but of size 10 Sqmm 2 core |
| 11 | Supply and fixing in replacement 1100 volts grade heavy duty PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor size of 16 Sqmm, 2 core complete all as specified and as directed. |
| 12 | Supply and fixing in replacement 1100 volts grade heavy duty PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor size of 10 Sqmm, 2 core complete all as specified and as directed. |
| 13 | Supply and fix in replacement of existing unserviceable driver for LED fitting of capacity 25 to 35 Watt all as per sample and as directed by GE. |
| 14 | Supply and fix in replacement of existing unserviceable driver for LED fitting of capacity 40/45 Watt all as per sample and as directed by GE. |
| 15 | Supply and fix in replacement of existing unserviceable driver for LED fitting of capacity 60 to 75 Watt all as per sample and as directed by GE. |
| 16 | Supply and fix in replacement of existing unserviceable driver for LED fitting of capacity 100 to 120 Watt all as per sample and as directed by GE. |
| 17 | Painting to existing steel tubular poles 11/09 mtr long including cross arms, clamps etc. with two coats of aluminium paint on surfaces exposed to view and making 30cm wide strips (total 5 Nos) with white and black paint alternatively on external surface above PCC copping including preparation of old painted surfaces by scraping complete all as specified and as directed. |
| 18 | M & L for cutting of existing road/ floor/ plinth/drain for taking outlaying of UG cable through GI pipe including necessary earth work excavation and making good to match with existing surface complete all as specified with PCC 1:3:6 type C1 by (using 20mm graded stone aggregate) complete all as specified and as directed. |
| 19 | Supply and fixing in repairs post top lantern LED type 25 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 20 | Supply and fixing in repairs post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 21 | Supply and fixing in repair GI bracket as per site requirement for LED Street light complete with lamps, nuts, bolts and washers to fix the pole complete all as specified and as directed. |
| 22 | Supply and fixing in repair LED street light fitting 35 Watt, 230 V AC outdoor type with high pressure die, cast aluminum housing and heat resistant, complete with driver with impact, and corrosion resistant including thermal, management in multiple optics complete with IP 66 protection complete all as specified and as directed. |
| 23 | All as per Srl No 22 above Ditto but 60 watt. |
| 24 | All as per Srl No 22 above Ditto but 90 watt. |
| 25 | Supply and fixing in repair LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP65/66 protection, with impact and corrosion resistant complete with driver and lamp.complete all as specified and as directed. |
| 26 | Supply and fixing in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP65/66 protection, with impact and corrosion resistant complete with driver and lamp.complete all as specified and as directed. |
| 27 | Supply and fixing in replacement SMC cable junction box of size 140x140x95mm suitable for street light/PTL, square type, weather proof, IP-66 including fixing of 6 Amp MCB SP and clamps, nuts, bolts, washers suitable for fixing to pole/GI pipes including suitable arrangement for cable entry and exit to street light fitting complete all as specified and as directed. |
| 28 | M&L in repair for Structural steel work of existing unserviceable Cross arms bracing, supports, clamps and back plates fabricated from steel sections including nuts,bolts, washers,welding ,bending cold or hot drilling holes for bolts in any shape or size as indicated or directed inclusive one coat of primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed. |
| 29 | Material and labour for replacement of existing unserviceable GI tubing light grade 50 mm bore for passing through cables under the floor,along the wall or along the pole complete all as specified and directed. |
| 30 | Material and labour for replacement of existing unserviceable GI tubing light grade 40 mm bore for fixing of post top lantern & laying of UG LT Cable complete all as specified and directed. |
| 31 | Supply & replacement of existing unserviceable Wood /PCC/steel tubular pole with new Steel tubular pole complete with cast iron base plate, finial taper plug, bolt, nuts & screws as specified type 410 SP-31 (9 mtr long ) including taking down old one Note: Excavation and PCC shall be measured and paid separately.complete all as specified and as directed. |
| 32 | Supply and fixing (in replacement of existing UNSV PTL lights) Circular LED Post Top lantern of 45 Watt offering excellent uniform illumination and aesthetics in one go. Made up of pressure Die Cast aluminium body and Opal PC cover with IP 66 and IK 07 with suitable size of GI Pipe light grade, PCC work and necessary excavation as per site required and as directed . |
| 33 | Supply and fixing (in replacement) bamboo LED bollard light 6Watts energy saving environment frindly, long life aesthetically designed aluminium landscape IP 65 luminaire for diffused lighting with high power LED as light source with nut, bolts and washers as required at site, necessary excavation and PCC 1:3:6 works as required at site and complete all as specified and as directed. |
| 34 | Supply and fixing (in replacement) solar street light 40 Watts is made with High efficiency Mono Crystalline Solar PV Moudle, Lithium Ferro Phosphate battery with in-built BMS technology, High efficacy LED, MPPT solar charge controller and aluminium extruded body & is specially programmed to automatically control the dimming and brightness of light, which increases the backup time complete with clamp, nut, and bolts as required at site and as directed. |
| 35 | Material & Labour PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in Cum bottom of pit in bed concrete of poles complete all as specified and as directed. |
| 36 | Material & Labour PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in Cum foundation of poles and stay etc complete all as specified and as directed. |
| 37 | Material & Labour PCC 1:2:4 type B1 ( using 20mm graded stone aggregate) as in Cum coping for Poles etc complete all as specified and as directed. |
| 38 | Comprehensive maintenance of DG Set including Alternator for routine check up of the engine for the smooth functioning and carrying out the checks complete as per the manufactures instructions all as specified and directed by the Engineer-in-Charge for 62.5 / 63 KVA DG Sets installed.Make: As per held at site(A) Every 50 Hours/One month whichever is earlier(a) Repeat the daily checks(b) Check oil level in the oil bath type air cleaner(c) Check the fan belt tension. The deflection should be within 8 to 10mm at the Centre (for details please refer to the maintenance manual)(d) Check the electrical connection |
| 39 | Comprehensive maintenance of DG Set for routine checkup of the engine for the smooth functioning and carrying out the checks complete as per the manufactures instructions all as specified and directed by the Engineer-in-Charge for 62.5 / 63 KVA DG Sets installed.Make : Make: As per held at site(a) Every 200 hours/Six month whichever is earlier(b) Repeat the 'A' Checks(c) Service the oil bath type air cleaner(d) Replace the engine main lub oil, air filter, fuel filter,oil filter element & sealing ring etc(e) Grease the water pump bearing(f) Clean the button filter. Note: f: spare parts shall be measured and paid separately |
| 40 | Supply and fix (in replacement) old unserviceable Air filter suitable for 63 KVA DG Set complete all as specified and as directed. |
| 41 | Supply and fix (in replacement) old unserviceable oil filter element suitable for 63 KVA DG set complete all as specified and as directed. |
| 42 | Supply and fix (in replacement) old unserviceable fuel filter element suitable for 63 KVA DG set complete all as specified and as directed. |
| 43 | Supply and replacement of Automatic voltage regulator (AVR) suitable for DG Set 62.5 / 63 KVA complete all as specified and as directed. |
| 44 | Supply and fix (in replacement) ignition switch suitable for 63 KVA DG Set complete all as specified and directed |
| 45 | Supply and fix (in replacement) fuel level sensor suitable for 63 KVA DG Set complete all as specified and directed |
| 46 | Supply and fix (in replacement) oil level sensor suitable for 63 KVA DG Set complete all as specified and directed |
| 47 | Supply and fix (in replacement) fuel level gauge suitable for 63 KVA DG Set complete all as specified and directed |
| 48 | Supply and fix (in replacement) oil level gauge suitable for 63 KVA DG Set complete all as specified and directed |
| 49 | Supply and fix (in replacement) fan belt suitable for 63 KVA DG Set complete all as specified and directed |
| 50 | Supply and fix (in replacement) old unserviceable priming pump suitable for 63 KVA DG set complete all as specified and as directed. |
| 51 | Repair and servicing of 62.5 / 63 KVA Engine Kirlosker type RB 66 / Cummins DG turbocharger assembly and replacing the service kit and reassembling testing complete all as specified and as directed. |
| 52 | Comprehensive maintenance of DG Set including Alternator AMF Panel for routine checkup of the engine for the smooth functioning and carrying out the checks complete as per the manufactures instructions all as specified and directed by the Engineer-in-Charge for 40 KVA DG Sets installed.Make : Make: As per held at site(A) Every 50 Hours/One month whichever is earlier(a) Repeat the daily checks(b) Check oil level in the oil bath type air cleaner(c) Check the fan belt tension. The deflection should be within 8 to 10mm at the Centre (for details please refer to the maintenance manual)(d) Check the electrical connection |
| 53 | Comprehensive maintenance of DG Set for routine checkup of the engine for the smooth functioning and carrying out the checks complete as per the manufactures instructions all as specified and directed by the Engineer-in-Charge for 40 KVA DG Sets installed.Make : Make: As per held at site(a) Every 200 hours/Six month whichever is earlier(b) Repeat the 'A' Checks(c) Service the oil bath type air cleaner(d) Replace the engine main lub oil, air filter, fuel filter,oil filter element & sealing ring etc(e) Grease the water pump bearing(f) Clean the button filter. Note: spare parts shall be measured and paid separately |
| 54 | Supply and fix (in replacement) old unserviceable Air filter suitable for 40 KVA DG Set complete all as specified and as directed. |
| 55 | Supply and fix (in replacement) old unserviceable oil filter element suitable for 40 KVA DG set complete all as specified and as directed. |
| 56 | Supply and fix (in replacement) old unserviceable fuel filter element suitable for 40 KVA DG set complete all as specified and as directed. |
| 57 | Supply and replacement of Automatic voltage regulator (AVR) suitable for DG Set 40 KVA , complete all as specified and as directed. |
| 58 | Supply and fix (in replacement) ignition switch suitable for 40 KVA DG Set complete all as specified and directed |
| 59 | Supply and fix (in replacement) fuel level sensor suitable for 40 KVA DG Set complete all as specified and directed |
| 60 | Supply and fix (in replacement) oil level sensor suitable for 40 KVA DG Set complete all as specified and directed |
| 61 | Supply and fix (in replacement) fuel level gauge suitable for 40 KVA DG Set complete all as specified and directed |
| 62 | Supply and fix (in replacement) oil level gauge suitable for 40 KVA DG Set complete all as specified and directed |
| 63 | Suply and fix (in replacement) fan belt suitable for 40 KVA DG Set complete all as specified and directed |
| 64 | Supply and replace the lubricant oil (IC engine for Gen set application). Old oil should be drained out after warming the engine. (Use MIL-L 2104C mono-grade oils only/15W40 overlain cummins/equivalent) complete all as specified and as directed. |
| 65 | Supply only coolant suitable for above mention DG Set.complete all as specified and as directed. |
| 66 | Suppy only distilled water. |
| 67 | Supply and replacement of battery 150 AH, 12 volts suitable for DG Set, complete all as specified and as directed. |
| 68 | Servicing of radiator assembly complete for cleaning after draining out cooling water/coolant, spaces cleaning the inter coller and replace unserviceable rubber hose pipes, circlip clamps, cleaning of raditor mix with appropriate cleaning agent, de-scaling by means of scale solvent as well as neutralising agent to arrest leakages by means of brazing etc including replacement of coolant for the capacity of DG Set 62.5 KVA / 63 KVA all as directed by GE. |
| 69 | M & L complete dismantling, servicing and repairs to FIP (Fuel Injection Pump) by & Fix of oil seals, 'O' rings, bearings, gaskets; reassembling the FIP , carrying out calibration by setting required pressure and testing of 62.5 KVA DG Set complete all as specified and as directed. |
| 70 | M & L taking down self starter assembly, removing the wornout brushes and renewing the brushes as per manufacturer's specifications, checking commutator surface, cleaning any dust, dirt, oil & foreign particles with dry clothesand compressed air, checking; repairing and greasing the drive assembly for the movement over soft spiness to enable drive assembly to move freely complete all as specified and as directed. |
| 71 | Supply & Fix of solenoid switch for 62.5/40 KVA DG Sets complete all as specified and directed. |
| 72 | Replacement of battery terminals of heavy duty brass with copper leads not less than 3 RM long - 02 No of suitable/existing size.complete all as specified and as directed. |
| 73 | Supply only battery charger of capacity voltage 12 Volt to 24 volts, ampere rage 1 Amp to 10 Amps complete all as specified and as directed. |
| 74 | Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to galvanised iron strip 32mm X 6mm (as earth lead strip), by means of bolt, nuts, check nuts and washer of GI and GI strip protected by provision of GI pipe light grade, 40mm bore upto test point including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25 x 25 x 3 mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 meters long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection to earth test point all as specified and testing on completion.NOTE :- Item of earthing includes the cost of 7.5 meter long galvanised iron strip 32mm X 6mm size and protection pipe of 40 mm bore galvanised iron light grade. |
| 75 | M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts, washers, check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frame 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade protection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I and connection to earth test point all as specified and testing on completion. |
| 76 | Supply and replacement of galvanised iron strip 32x 6 mm and fixing screws buried in ground or above ground for test point complete all as specified and as directed. |
| 77 | Disconnecting the inlet and outlet connections from the electric circuit, taking out and strip opening and repair/replacement of defected parts in the 50 KVA voltage stabilizer.(i) Disconnecting the moving arm, servo motor, control circuit and provide minor items reqd in voltage stabilizer(ii) Complete servicing of the voltage stabilizer, setting the output voltage 440 volt accuracy + 1% variation, input voltage changes upto + 50% complete servicing and testing all as specified and directed by GE. Note:-Make: As per held at site |
| 78 | Supply and fixing (In replacement) moving arm of 50 KVA voltage stabilizer 3 phase naturally oil cooled type complete all as specified and as directed. |
| 79 | Supply and fixing (In replacement) servo motor of 50 KVA voltage stabilizer 3 phase naturally oil cooled type complete all as specified and as directed. |
| 80 | Supply and fixing (In replacement) motor driver of 50 KVA voltage stabilizer 3 phase naturally oil cooled type complete all as specified and as directed. |
| 81 | Supply and fixing (In replacement) control circuit of 50 KVA voltage stabilizer 3 phase naturally oil cooled type complete all as specified and as directed. |
| 82 | Supply and laying High density polyethylene pipes (HDPE) for cable protection of pressure rating 6 kgf/cm2 laid in trenches of size 25 mm Bore complete all as specified and as directed. |
| 83 | Supply and fix in replacement Off LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 100 Amps complete all as specified and as directed. |
| 84 | Supply and fixing (In replacement) of digital 24 hour time switch street light panel out door type range from 6 kW to 12 kW, Provided with Protection Degree IP 54, Extended wide band coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation complete all as specified and as directed. |
| 85 | Supply & replacement of digital/auto/manual time switch with all fitting and complete all as specified and as directed. |
| 86 | Supply and fix in replacement ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 63 Amps complete all as specified and as directed. |
| 87 | Supply and fix in repair 3 core 1.0 Sqmm PVC copper cable multi stranded drawn through inside pole/ PVC conduit to connector of street light fitting/ post top light, gate light and garden lights etc including taking down the existing old u/s wire complete all as specified and as directed. |
| 88 | Supply and fix in repair PVC conduit 20 mm dia medium grade complete with connecting accessories such as, screw, shaddles, socket, bend, elbow, tee etc and fixing in wall/ floor etc including taking down the existing old u/s one complete all as specified and as directed. |
| 89 | Supply & Fixing in replacement Single pointed air termination aluminium rod 12 mm dia 300mm long with base plate/ insulators complete all as specified and as directed. |
| 90 | Supply & Fixing in replacement aluminium strip 25mm x 3.15mm complete with saddles/ insulators and fixing screws for fitting the strip fixed to pole on vertical/ horizontally complete all as specified and as directed. |
| 91 | Supply and fixing in replacement of test point terminal block made of gun metal or phosporous bronge size, 75x75x25mm drilling & screwed and fixed to pole and connected with earth strips complete all as specified and as directed. |
| 92 | Supply and fixing in replacement of Tri glow 18 mtr LED rope light indian tri color strip light - orage+white+green color in single strip plug and play waterproof IP 65 energy efficient outdoor type complete all as specified and as directed. |
| 93 | Excavation in trenches in soft/loose type of soil not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr wide for laying of cables, erection of poles, struts, stays etc and getting out complete all as specified and as directed. |
| 94 | Supply & replacement of existing unserviceable busbar box , installation, testing and commissioning of factory fabricated prewired bus bar, cubical type of appropriate size out door dust vermin proof, made out of 40x40x6mm angle iron frame/legs and 3.15 mm thick CRCA sheet with openable shutters on both sides (front & rear), powder coated externally and internally, having locking arrangement mounted on four legs 90cm high (30 cm below ground level and 60 cm above ground level), Panel embedded in PCC (1:2:4) type B2 of suitable size with clear working space all around the bus bar complete all as specified & directed by the Engr-in-Charge to accommodate the following accessories :-(a) MCCB 4 Pole 160 A 25KA with spreader link - 1 No(b) Aluminium bus bar 200 A for three phase and neutral duly insulated with sleeves of different colour RYBNote : (i) Incoming and outgoing cable shall be fixed with appropriate size of copper thimble.(ii) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.(iv) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. |
| 95 | Supply, installation, testing and commissioning of factory fabricated prewired bus bar, cubical type of appropriate size out door dust vermin proof, made out of suitable size of angle iron frame/legs and 3.15 mm thick CRCA sheet with openable shutters on both sides (front & rear), powder coated externally and internally, having locking arrangement mounted on four legs 90cm high (30 cm below ground level and 60 cm above ground level), Panel embedded in PCC (1:2:4) type B2 of suitable size with clear working space all around the bus bar complete all as specified & directed by the Engr-in-Charge to accommodate the following accessories :-(a) Incoming(i) MCCB TH ADJ 4 Pole 125 A 25KA with spreader link - 1 No(b) Outgoing(i) MCCB TH ADJ 4 Pole 63 A 25KA with spreader link - 3 No(ii) MCB TPN 40-63 AMP 415V, 50Hz, 10KA - 04 No(iii) Aluminium bus bar 200 A for three phase and neutral duly insulated with sleeves of different colour RYB(iv) CTs 160/5 A-03 Nos(v) Phase Indicator RYB-03 Nos(vi) MFM meter-01 NoNote :(i) Incoming and outgoing cable shall be fixed with appropriate size of copper thimble.(ii) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.(iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. |
| 96 | Supply, installation, testing and commissioning of factory fabricated prewired APFC panel, cubical type of appropriate size out door type dust vermin proof, made out 40x40x5mm of angle iron frame/legs and 3.15 mm thick CRCA sheet with both side openable shutters (front & rear), powder coated externally and internally, having locking arrangement 450 mm long mounting legs, embedded in PCC (1:2:4) type B2 of suitable size with clear working space all around the bus bar complete all as specified & directed by the Engr-in-Charge to accommodate the following accessories :-(i) MCCB with O/L, S/C, TM based 100 Amp TP 36 KA with spreader link - 1 No (incomer)(ii) MFM meter-01 No(iii) CTs 160/5A-03 Nos(iv) Phase indicator RYB -03 Nos(v) APFC relay 6 step-01 No(vi) MCB TP, C- type 16 Amp, 10 KA-05 Nos(vii) Capacitor duty contactor 5 KVAR- 05 Nos(viii) Capacitor S/D type 5 KVAR-05 Nos(ix) Status indicator ON- 05 Nos(x) Selector switch-05 Nos(xi) Aluminium bus bar 150 A for three phase and neutral duly insulated with sleeves of different colour RYB .Note :(i) Incoming and outgoing cable shall be fixed with appropriate size of thimble.(ii) Apron shall be provided at bottom for protection of cable to avoid entry of vermins, reptiles.(iii) Entries of all sizes of cables in panel should be done through adequate size of metallic cable glands. |
| 97 | Supply and fixing in replacement MCCB 4 Pole, 415 V, Adjustable type, 400Amps with breaking capacity 36 KA complete all as specified and as directed. |
| 98 | M & L for MCCB 4 Pole, 415 Volt Adjustable type, 100 Amp with breaking capacity 25 KA, with extended terminal & suitable size of cable lugs and taking down old one complete all as specified and as directed. |
| 99 | M & L for rack out of unserviceable ACB (Air circuit breaker) 800 amp, 415 volt , 50 Hz rating from the panel and servicing, repair/ replacement of unserviceable spare parts and rack in at the same position after repair including testing the ACB upto full satisfaction complete all as specified and as directed. Note :- worn out spare parts measured and paid separately |
| 100 | S&F in-repair of UV release for air circuit breaker 800 amp rating complete all as specified and as directed. |
| 101 | S&F in-repair of shunt coil , for air circuit breaker 800 amp rating complete all as specified and as directed. |
| 102 | S&F in-repair of closing coil , for air circuit breaker 800 amp rating complete all as specified and as directed. |
| 103 | S&F in-repair of normal type relay , for air circuit breaker 800 amp rating complete all as specified and as directed. |
| 104 | Repair/Maintenance of unserviceable APFC panel, 25/100/200KVR, 415 volt , 50 Hz rating and servicing, repair/ replacement of unserviceable spare parts including testing the APFC panel upto full satisfaction complete all as specified and as directed. Note :- worn out spare parts measured and paid separately |
| 105 | S&F in-repair of APFC relay of 06/08 steps suitable for upto 200 KVAR APFC panel, complete all as specified and as directed. |
| 106 | S&F in-repair of CT coil 160/5 suitable for upto 200 KVAR APFC panel, complete all as specified and as directed. |
| 107 | S&F in-repair of indicator lamps complete all as specified and as directed. |
| 108 | S&F in-repair of selector switch complete all as specified and as directed. |
| 109 | S&F in-repair of capacity duty contactor suitable 25 KVAR capacitor complete all as specified and as directed. |
| 110 | S&F in-repair of capacity duty contactor suitable 15 KVAR capacitor complete all as specified and as directed. |
| 111 | S&F in-repair of capacity duty contactor suitable 10 KVAR capacitor complete all as specified and as directed. |
| 112 | S&F in-repair of capacity duty contactor suitable 5 KVAR capacitor complete all as specified and as directed. |
| 113 | S&F in-repair of cylindrical type capacitor bank of 5 KVAR, complete all as specified and as directed. |
| 114 | S&F in-repair of cylindrical type capacitor bank of 10 KVAR, complete all as specified and as directed. |
| 115 | S&F in-repair of cylindrical type capacitor bank of 15 KVAR, complete all as specified and as directed. |
| 116 | S&F in-repair of cylindrical type capacitor bank of 25 KVAR, complete all as specified and as directed. |
| 117 | S&F in-repair of 3 phase 4 wire digital type volt meter with suitable size CT/PT, 0-500 V complete all as specified and as directed. |
| 118 | S&F in-repair of 3 phase 4 wire digital Ammeter with suitable size CT/PT complete all as specified and as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender