Tender For Improvements To Electrical Installation, Ac & Ups Arrangements To The Office For Honble Health & Family Welfare Minister In Fourth Floor At District Collectorate Building In Tiruppur District.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Sep 2026
4 days left
EMD
9850
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tiruppur → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Improvements To Electrical Installation, Ac & Ups Arrangements To The Office For Honble Health & Family Welfare Minister In Fourth Floor At District Collectorate Building In Tiruppur District.
BOQ
| Sl. No. | Item Description |
| 1 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module GI switch box in flush wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire with painting of Suitable colour for Open PVC Light point / fan point (for electronic regulator) ( 5 points / Coil) Higher End |
| 2 | Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with Module GI switch box in flush wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire with painting of Suitable colour for Open PVC Light point / fan point (for electronic regulator) ( 6 points / Coil) Higher End |
| 3 | Supply and fixing of single box type 18W/22W 4Feet LED Fitting with 20W Crystall glass LED tube (Higher End) complete with TW round blocks on wall or ceiling with PVC unsheathed copper leads from terminals to the fitting. |
| 4 | Supply and fixing of 18W LED Round type Recessed fitting with LED (Higher end) on false Ceiling from ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting. |
| 5 | Supply and fixing of 24W LED Down Light (Make: Model: Lukar Duro down Lights LDR24MTL5Y / Eqv) with connection complete. |
| 6 | Supply and fixing of 30W LED Down Light Fitting (Make: Lukar CORVUS Lights LCOBBSRR 30GBK / Eqv) with connection complete. |
| 7 | Supply and fixing of 14W LED Strip Light (Make: Lukar LORO LED Strip Indoor LS5050 / Eqv) with connection complete. |
| 8 | Supply and fixing of 9W LED Lamp for BH point. |
| 9 | Supply and fixing of 20W LED Mirror Light (Higher end) complete with connection complete. |
| 10 | Supply and fixing of 1200mm (48\\") sweep AC ceiling fan complete (Make: Orient - Aeroquiet BLDC 5Star rating / Eqv) with 2 module 100W fan step regulator (Higher end) with 600mm down rod with fan clamp with side plates and cross arm of size 450mm (18\\") |
| 11 | Supply and fixing of 1200mm (48\\") sweep AC ceiling fan complete (Make: Havells Quick air Neo / Eqv) with 2 module 100W fan step regulator (Higher end) with 600mm down rod with fan clamp with side plates and cross arm of size 450mm (18\\") |
| 12 | Supply and fixing of 1200mm (36\\") sweep AC ceiling fan complete (Make: Orient - JAZZ 3Star rating / Eqv) with 2 module 100W fan step regulator (Higher end) with 600mm down rod with fan clamp with side plates and cross arm of size 450mm (18\\") |
| 13 | Supply and fixing of 250mm (9\\") sweep AC Modular exhaust fan (Higher end) with connection complete. |
| 14 | Supply and fixing of 3nos.6A two module 3 pin socket, 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End |
| 15 | Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End |
| 16 | Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) |
| 17 | Supply and fixing of 32A DP MCB complete with 2pole sheet steel enclosure (Higher end) in flush with wall with earth connection |
| 18 | Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 32A DP MCB as incoming and 10 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End |
| 19 | Supply and fixing of 4 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB as incoming and 12 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End |
| 20 | Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire with painting of suitable colour. |
| 21 | Supply and run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 4sq.mm copper wire with painting of suitable colour |
| 22 | Supply and Run of 2 of 6 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection of 6 sq.mm copper wire with painting of suitable colour. |
| 23 | Supply and clarmping of 3½ x 25 sq.mm. PVC LTUG armoured cable on post or on wall with MS clamps |
| 24 | Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection |
| 25 | Supply and providing cable end termination of 3-1/2x25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete |
| 26 | Supply erection testing commissioning of 1.5 TR (6000 KCal / Hr) ABS Plastic Split type Air Conditioner conforming to IS 1391 [Part-2] 1992 with Rotary compressor and Copper coil operating on Non CFC refrigerant suitable for wall mounting for operating on 230V 50HZ single phase AC supply with Five Star rating Model as per BEE Specification and capable of performing the following functions. A) Cooling B) Dehumidifying C) Air circulating D) Filtering the installation work for the above split type AC units includes the following. 1.Mounting/ fitting indoor and outdoor units at their respective locations. 2.Laying refrigerant pipe line of 6mtrs distance and connecting the both units after drilling hole in the wall if required thickness of the copper tubing shall not be less than 0.80mm 3.Insulating the suction pipe with expanded polythene foam 5mm thick tubing. 4.Laying 15mm dia flexible PVC drain pipe of 6mtrs length to throw out the condensate water being formed in the indoor unit. 5.Leak testing the entire gas unit. 6.Charging refrigerant gas in the unit. 7.Suitable electric wiring to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoor units up to 4mtrs length and up to switch within 3mtrs of location of indoor unit. |
| 27 | Supply and fixing of 4KVA Automatic voltage stabilizer of wall mounting type with Automatic time delay switching arrangements suitable to operate on 230V Single phase supply. |
| 28 | Supply erection testing commissioning of 2.0 TR (6000 KCal / Hr) ABS Plastic split type Air Conditioner conforming to IS 1391 [Part-2] 1992 with Rotary compressor and Copper coil operating on Non CFC refrigerant suitable for wall mounting for operating on 230V 50HZ single phase AC supply with Four Star rating Model as per BEE Specification and capable of performing the following functions.A) Cooling B) Dehumidifying C) Air circulating D) Filtering the installation work for the above split type AC units includes the following. 1.Mounting/ fitting indoor and outdoor units at their respective locations. 2.Laying refrigerant pipe line of 6mtrs distance and connecting the both units after drilling hole in the wall if required thickness of the copper tubing shall not be less than 0.80mm 3.Insulating the suction pipe with expanded polythene foam 5mm thick tubing. 4.Laying 15mm dia flexible PVC drain pipe of 6mtrs length to throw out the condensate water being formed in the indoor unit. 5.Leak testing the entire gas unit. 6.Charging refrigerant gas in the unit. 7.Suitable electric wiring to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoor units up to 4mtrs length and up to switch within 3mtrs of location of indoor unit. |
| 29 | Supply and fixing of 5KVA Automatic voltage stabilizer of wall mounting type with Automatic time delay switching arrangements suitable to operate on 230V Single phase supply. |
| 30 | Supply and fixing of MS stand for fixing outdoor unit |
| 31 | Supply and laying of 5/8” and 3/8” copper refrigerant pipe (Extra beyond 3 metres supplied with AC unit) |
| 32 | Supply and fixing of 1 inch PVC water drain pipe line on wall with suitable Clamp as required. |
| 33 | Supply and fixing of 3000 VA ONLINE (3.0 kVA) UPS system (48V DC) for commercial and industrial applications with 3Nos of 12V, 100AH, Exide IT 500 Tall Tubular batteries with 1 hour back up for mentioned capacity fully load operation with battery stand with wheel angle iron frame arranged with shelf and suitable colour painting & with the following Features.(1) Fully automatic change over(2) Over load indication-output cut off (3)On Inverter mode short circuit protection (4) Electronic trip for Low battery / auto release (5)Current & Voltage controlled Topology(6) Multiple PWM MOSFET / IGBT Topology and thyrister controlled (7) DC Volt meter AC Output meter (8) Harmonic distortion: 3 % for non linear load (9) Transient response: 2 % on 40 % step load Recovery time within 100msec(10) Out put power factor: 0.80 (11) Efficiency: 85 % to 95 % (12)Over load: 120 % for 10mints (13)Alarm for low battery / output high / over load / trip (14)Battery charging and discharging meter (15)AC load current and frequency meter 16) LCD Meter – static by pass switch (Microtek / Exide / Equivalent ) |
| 34 | Supply and fixing of 1000W automatic electric water heater of 25litres capacity suitable for 230V 50 c/s AC supply on suitable MS clamps with 3 core flex wire, but without plumbing work |
| 35 | Supply and fixing of 138cm (55\\") LED TV [Make: Samsung QLED ultra HD QA55QEF6AULXL / Equ] on wall with necessary connection complete. |
| 36 | Supply, Installation, Testing of Professional 4K, All-In-One VC Camera bar, extension TABLE MIC, AI face tracking and auto zooming with connection Complete. |
| 37 | Supply, fixing and termination of D-Link Make 8 Port PoE switch in existing Rack with accessories. |
| 38 | Supply and run of Unarmoured LAN/ Cat6 cable in PVC rigid pipe on wall and Ceiling and making good of portion with suitable colour |
| 39 | Supply fixing and termination of I/O Box for LAN with all relevant accessories including I/O Socket,PVC Module,Face Plate and Patch Cord |
| 40 | Supply and fixing of AC / DC 76mm Buzzer / call bell suitable for 230 volts 50 c/s single phase AC supply on suitable TW board with push switch |
| 41 | Earthing as per the ISI specification with an earth electrode of 2.10metre Class'B' GI pipe of dia not less than 40mm with copper earth plate of size 125mmx50mmx6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry |
| 42 | Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection |
| 43 | GST@18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender