Tender For Providing And Installation Of Low Lift Pumping Machinery And Other Electromechanical Accessories At Newly Constructed Two Nos River Bed T.W For Onda Chabra And Its Adjoining Mouzas Water Supply Scheme Under Bankura Mechanical Division Phe
Tender Overview
Project Description
Tender for Providing And Installation Of Low Lift Pumping Machinery And Other Electromechanical Accessories At Newly Constructed Two Nos River Bed T.W For Onda Chabra And Its Adjoining Mouzas Water Supply Scheme Under Bankura Mechanical Division Phe Dte, Dist: Bankura.
BOQ
| Sl. No. | Item Description |
| 1 | PART-A |
| 2 | Supply, delivery of clear water vertical wet type submersible pump suitable for bore well conforming to IS:8034(and as amended threreafter) with standard MOC for potable clear cold water and BEE 3 star ( Minimum) rated capable with a continuous rated-2 pole suitable wet type vertical squirel cage induction motor conformoning to IS: 9283(and as amended threafter) suitable for operation in AC Three phase 415V, 50Hz(category B motor) a) Discharge-22 M3/Hour at head of 29 MtrSuitable for 200mm dia T.W |
| 3 | Supply, delivery and storage at site 80 mm dia M.S. E.R.W. column pipe, 4.85 mm thickness with both end threaded including one socket and threaded protector painted with anti corrosive painti) 1.5 Mtr. Long |
| 4 | Supply, delivery at site M.S fabricated T/W top cover (flange type)suitable for 200 mm dia tube well made of 12 mm thick M.S. plate with centrally welded 80mm dia M.S Socket(Heavy type) and 40 mm dia socket at side for 40 mm dia G.I. Pipe (for cable entry) & fitting fixing the heavy type G.I pipe specials & nut bolt including welding all joints and supplying all 80 mm dia shorts pieces, bends. flanges, sockets, enlargers etc. & 40 mm dia G.I. pipe, bend, union, joints, elbows as required for complete the job as per direction of EIC |
| 5 | Supply & delivery of M.S. suspension clamp with necessary nuts, bolts & washer etc suitable for 80mm dia pipe |
| 6 | Supply delivey of M.S clamp suitable for holding 150 mm X 20 mm dia pipe. M.S. clamp made of 35mm x 6 mm thick strip, with nuts & bolts for holding 10 mm dia Al, Ar cable protection pipe with 150 mm dia rising main as per direction.N.B- Numbers of M.S clamp should be purchased as per site requirement |
| 7 | Supply & delivery at site & storage CIDF single door swing check Non rising type NRV as per IS:5312 Part – Ii) DN 80 mm (P.N.–1.0) rating (for Submersible delivery header) |
| 8 | Supply and delivery at site CIDF non-rising Sluice Valve generally conforming to IS 14846 i) 80mm dia (P.N-1.0) rating |
| 9 | Supply, delivery and storage at site of following L.T cables |
| 10 | 10 sq. mm, 3 core, 1.1 kv, XLPE insulated Ar. Al. conductor cable Confirming IS:7098 (Part-1) 2011a) 2 nos Sub mersible motor x 300mtr =1200 mtr |
| 11 | 2.5 sqmm 3core, 1100 Volt grade copper water proof PVC insulated flat submersible cable,Conforming To IS : 694 As Amended Up To Date. Make-As per approved vendors for electro-mechanical items of 29/12/2023 (WBPHED/VL/ME/01) |
| 12 | Supply delivery at site 35 sqmm sigle Core, 1100V grade heavy duty coper flaxible unrmored coper cable ,cable As Per IS- with Up To Date Amendments,(From Bus Bar to Main Switch ) |
| 13 | Reparing of MCC cum PDB panel Board |
| 14 | Dismantling and takenout of Existing ( defective One ) , with its cables , Nuts & Bolts , cleaning the space making necessary arrangements for fitment of supplied items |
| 15 | Supply delivery of following items for ( 3.7KW feeder ) DOL Starter- 3 Nos. : |
| 16 | Motor Protection Circuit Breakers (Manual motor starters) with short -circuit, overload and phase loss protection TP, 415V, 50Hz A.C overload range Amp range (10-16) Amp S/C Icu breaking capacity 16 kAType- MS116-10 for ABB make |
| 17 | 16A TP 415V, 3Ph, 50Hz, Air Break Power Contactor with 1NC Addon Block, 220V AC Coil |
| 18 | Motor Protection Relay Analog type 24-240V AC/DC Current Range (3-30)Amp Relay, with OC, LR ,UC UB, SC Protection (EOCR SSD with Display for Schneider Make ) |
| 19 | 2 KVAR Capacitor Bank, 440V, 50Hz AC Cylindrical Capacitors |
| 20 | TP MCB, 6Amp, 10KA, C Characteristic |
| 21 | Capacitor 2.5 kvar, 415V AC, 3Ph, 50Hz Capacitor Duty Contactors for Capasitor |
| 22 | On Delay Timer with 1 C/O contracts (0.5Sec.-3Sec., 240V, AC) |
| 23 | C.T. 30/5, 5VA, CL-1, Tape Wound Type |
| 24 | Digital type 96mm x 96mm moving Iron type amper Range (0-60) A.C Phase, Amp Ammeter with ASS |
| 25 | Compact Indicating Lamp LED (22.5mm dia) (Red, Yello) 220/240 V AC 50/60 Hz for Phase Indication |
| 26 | Compact Indicating Lamp LED (22.5mm dia) (Blue) 220/240 V AC 50/60 Hz for Phase Indication |
| 27 | Compact Indicating Lamp LED (22.5mm dia) (Green , Red) 220/240 V AC 50/60 Hz for On & OFFIndication |
| 28 | Compact Indicating Lamp LED (22.5mm dia) (Amber) 220/240 V AC 50/60 Hz for Trip Indication |
| 29 | 230V, 10Amp, Modular A.C Push button actuators (Green, RED) (with plastic front ring) with 1 NC Element (Raised) for Start & Stop |
| 30 | Supply delivery of deferent hard wire i.e- Coper Bus Bar, PVC insulating tap, cable socket, CRC, Cable Duct , and other necessary as per requirement |
| 31 | Supply delivery of 200 Amp, 415 V TPN 50 Hz in Sheet Steel enclosure rewireable type porcelein Fuse with side handle operated Main Switch unit .For WBSEDCL power received |
| 32 | Supply of PVC pipes & fittings Schedule 80 (mediumduty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I).a) PVC Pipes dia 32 mm dia [ for Submersible Cable protection] |
| 33 | PART-B |
| 34 | Installation & commissioning of all items mentioned as in 1 to 10 Exept Item no-8,10 &14 including supply of all erection items, as required for installation of Submersible pumping machineris all valves, including supplying all necessary items i.e- nut & bolt wather rubber gasket, with painting, Finishing of cables for complete the installation as per Hydraulic standard & IE rules in compliance by engaging skilled technician all complete as per Technical specification and upto entire satisfaction of EIC. |
| 35 | Fixing & laying of Cable along the lenth of River Bed 150mm dia delivery pipe line by the above supplyed M.S 35 mm x 6 mm MS Clamp as per direction of E.I.C i) 10 sq mm 3 core XLPE AL Ar cable |
| 36 | Making double Earthing arrangement in complience with I.E rules by G.I pipe electrode with G.I funnel (50mmx 3 mtrlong) direcrt ground with supplying and fixing of G.I earth busbar drawing of 25mmx 6mm G.I earth conductor between pits and as earth busbar inside the pump house and 20mmx 3 mm GI strips for continuty to different electrica; installation i.e main switch panel and feeder box etc and making suitable size earth pit etyc all complete.For MCC Panel |
| 37 | Supply and delivery and storage of the following at site |
| 38 | Octagonal sections pole suitable for 50m/sec wind speed with raising lowering system comprising ,head frame ,luminaries carriage suitable to install 6 nos luminaries in symmetrical arrangement, double drum winch , 6mm dia SS wire rope trailing cable ,connector , integral power tool motor, manual handle, junction box, aviation obstruction lightlightening arrester and foundation bolts manufactured from special steel along with nuts, washer,anchor plate and common template. and feeder box with nessesary arrangementi) Height of the Pole 10 mtr |
| 39 | Flood lighting luminaire with single die ceramic base high power LED, PDC housing & integrated flood optics to ensure uniform distribution maintenance free system, ideal for sports lighting, area lighting and high mast lighting.- M.No-BVP483 LED210 CW AWB PSU GR for Philips make or equivalent make |
| 40 | Surge protection device suitable for both 1+2 type protection 3 phase system 440V max operating voltage and max current 40KA along with sheet steel enclosure make- as per approved unified vendor list vide official website of WBPHED |
| 41 | Supply delivery at site of 32 Amps 415 Volt TPN re-wireable fuse type side handle operated and fixing Sheet steel Main Switch |
| 42 | Supply delivery at site of 10sqmm 4 core 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments, |
| 43 | Laying of above cable through the under ground trench having depth 760mmX width 460mm and laying 8 nos brick for per mtr length of the cable for protection of the cable including sand filling ramming complete as per IE rules as per direction of the EIC. |
| 44 | Construction of shallow foundation with M20 grade concrete for the high mast considering the safe soil bearing capacity at site as 10T/sq mt at 2 mtr depth with all materials and labour as per direction of EIC. |
| 45 | Erection and commissioning of the above pole with the help of suitable tools and plants wiring of luminaries with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor of 1.5 sq mm lugs, MCB and all labour as per direction of EIC |
| 46 | Provision of GI pipe earthing for high mast with 3 mtr long 50 mm dia GI pipe including connection to high mast earth terminal with 25 x 6 mm GI flats with all materials and labour as per direction of EIC and as per technical Specification |
| 47 | Supplying and fixing 240/415 V MCB of Breaking. 6-32 A capacity 10kA & C characteristics on din rail of existing DBs and necessary connection |
| 48 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment |
| 49 | 2+4 way |
| 50 | Add: 18% GST |
| 51 | Add: 1% Cess Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender