Drinking Water Supply and Sanitation Government Departments Closing in 2 days TDR #57341340

Tender For Construction Of 200 Mm X 165 Mm X 200 Mtr Depth. Rig Bored Tube Wells And Providing And Installation Of Submersible Pumping Machineries Along With Other Allied Electromechanical Works For Mini Water Supply Scheme At Ghatusole Village Of Fu

Issued by Government Departments · Bankura, West Bengal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
18 Sep 2026
2 days left
EMD
29000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bankura → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of 200 Mm X 165 Mm X 200 Mtr Depth. Rig Bored Tube Wells And Providing And Installation Of Submersible Pumping Machineries Along With Other Allied Electromechanical Works For Mini Water Supply Scheme At Ghatusole Village Of Fulkushma Gp,Raipur Block In The District Of Bankura Under Bankura Mechanical Division Phe Dte.

BOQ

Name of Work:- Construction of 200 mm X 165 mm x 200 Mtr depth. Rig Bored Tube wells and Providing and Installation of submersible pumping machineries along with other allied electromechanical works for mini water supply scheme at Ghatusole village of Fulkushma GP,Raipur block in the District of Bankura under Bankura Mechanical Division PHE Dte.
Sl. No. Item Description
1Supply and delivery at site the following material
2a) Supply and delivery of UPVC pipe (CM conforming to IS :12818 :2010 ( CIPET Certificate)
3i) 200 mm dia
4b) Supply and delivery of UPVC Cap, 200 mm dia
5Geophysical investigation of the acquifer by electrologging system with alltools and plants as necessary including supply of necessary report.(1no pin point site to be 3nos test)For 1nos T/W @3nos test= 3 Test
6Supply and delivery of Bentonite Powder conforming to IS 6186 :1986.
7Mobilisation Charges of all tools & Plants along with accessories, material, labour, supervision etc. at site of work required in connection with boring and testing work, including setting up boring rigs and shifting to different Bore-hole points etc. and also including withdrawal of same from the site after completion of work, complete as per direction of Engineer-in-Charge.
8Drilling bore hole in DTH method through any kind of soils and rocks in overburden suitable for lowering and fitting fixing of 200mm dia. casing pipe up to an average depth of 45 mtrs. and subsequently 165 mm diameter boring through any kind of rocky formation upto a total depth of 150 mtrs (for dry drilling/sufficient water not achieved drilling may be continue up to 200mtr) including all other works necessary for boring and lowering fitting fixing of MSERW/UPVC cashing pipe suitable for 165mm dia drilling in rockbed and grouting the sameas per direction of E.I.C. including (incase of MSERW cashing pipe) the cost of weilding of MSERW cashing pipe and weilding the top of the cassing pipe with one 8mm thick M.S cover plate( with supply and delivery of the plate) neccessory aggrement to be made for proper security bore hole. (Rate areinclusive of all materials neccessory for drilling worksN.B- a) MSERW/UPVC cassing pipe should be properly incerted or lowered in overburden zone for proper RBTW formationb) incase of of collapse bore hole, payment will be done for clear measurable depth only
9a) 0 to 45 mtr (Over Burden) (45mtr for each T/W @ 1 nos T/W =45 mtr)
10b) 45 to 200 mtr. and above (175mtr for each T/W@ 1 nos T/W =175mtr))
11Washing, chemical treatment and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping with necessary arrangements by supplying of disinfectant including hire and labour charges for all tools and plants and scaffolding as required to complete the job
12Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.For 1nos T/W @1no water sample per T/W = 1item
13Yield test of different drilling site to be done by using submersible pump with cable ,starter,DG set all pipe fitting, 220 Lts drum/V notch.Measurement of draw down and yield in alteast three different depth have to be noted by running pump for minimum three consecutive hours in prescribed format as per direction of E.I.C.
14supply and dlivery of the following materials at site as per direction: -
15Supply and delivery of a clear water vertical wet type submersible pump suitable for bore well conforming to IS: 8034 ( and as amended thereinafter) with standard MOC for potable clear cold water and BEE 3 Star Rated. capable of discharging noted M'/h. against the head of the water column. The pump shall be directly coupled with a continuous rated 2-pole suitable wet type vertical squirrel cage induction motor conforming to IS: 9253 (and as amended thereafter ), suitable for operation in AC Three phases 415 V,50HZ (category B motor)Discharge-5 m3/hr Head-81 meter
16Supply and delivery of 2.5 sqmm 3core, 1100 Volt grade copper water proof PVC insulated submersible flat submersible cable,Conforming To IS : 694 As Amended Up To Date. Make – Approved vendor list
17UPVC 50mm. Ф. Heavy type Column pipe with one end socketted and both end threaded make – Astral / Ashirbad / approved
183 mtr long (17kg/cm2)
191.5 mtr long
20Supply and delivery at site 50 mm dia CI Top Adaptor with flange (Single clamp)
21Supply and delivery at site 50 mm dia CI Bottom Adaptor
22Heavy type MS fabricated suspension clamp suitable for above 50 mm Ф column pipe
23Split type MS fabricated suitable tubewell cover with necessary arrangement for clamping devices including holes for air pipe and cable entry gland
24102mm Ф 0-12 Kg / cm2 pressure gauge with brass three way cock and syphone and other necessary fittings Make H Guru / Febig
25Supply and delivery at site of 50mm Φ following GI specials
26Plain Tee
27100mm long nipple
28900 Bend
29CIDF single door swing check NRV (P.N.–1.0) rating as per IS:5312 Part – I,
30CIDF non-rising Sluice Valve (P.N-1.0) generally conforming to IS 14846
31Union
3225mm Φ following GI specials for cable protection
33100mm long nipple
34900 Bend
35Union
36GI Pipe (Medium Non TATA make)
37Supply and delivery at site of Safety device for the above pump set by supplying MS clamp with proper clamping arrangement and nylon rope as per requirement including supply of all required materials as required
38Supply and delivery at site of Fabricated Outdoor type floor mounted MCC panel 2mm CRCA sheet metal body and 3mm thick canopy with approximate size – (600 x 900 x 250) mm vermin proof IP54 with 32A MCB and suitable Voltmeter, ammeter and 3-5 HP DOL starter as per direction and Attached specification Make – System & Control / ECS / other PHED approved Vendor
39Supply and delivery at site of 25mm2 3Core, 1100V grade XLPE insulated aluminium Armored cable ,cable As Per IS-7098 (Part 1) 2011 with Up To Date Amendments,Make – PHED approved Vendor
40Supply and delivery at site of 32A 415V 50Hz TPN Sheet steel Main Switches with rewireable porceline fuse unitMake - Havells / Standard / L&T
41Supply & delivery of outdoor type LED light fixture Operating Voltage 140V-270 V AC 50Hz ,LED light fixture having LM6 pressure die cast Al. housing pot optical reflector and heat resistant toughened Polycarbonate/ Glass cover complete set.M.No-BRP333 LED110 CW R5C FG PSU S1 V1(Make Philips/equivalent model)
42Supply delivey of 1.5 mtr. long M.S Arm bracket made out of 40 mm dia MS pipe
43Supply of swaged / stepped type steel tubular pole of 9 m long (410‐SP‐26) conformed to IS : 2713-1980. The length of bottom section shall be 5.0 mtr, middle section shall be 2.0 mtr & top of 2.0 mtr. The bottom section of the pole shall be 114.3 x 4.50mm dia, middle section of the pole shall be 88.9 x 4.05 mm dia & the top portion shall be 76.1 x 3.25 dia, 1.5 mtr. long MS bracket made out of 40 mm dia MS pipe shall be fixed on top of the pole for fixing light fiottings. The MS mounting bracket shall be fixed on top of the pole weight approx 92 KgSingle ArmMake- Calcutta Pole/India Pole/jindal/Any approved make
44Supply and delivery of 6 sq.mm. 2 core PVC insulated XLPE Ar. AL conductor cable, As Per IS-7098 (Part 1) 2011 with Up To Date Amendment
45Earth work in excavation of foundation trenches or drain in all sorts of soil ( including mixed soil but excluding laterite or sand stone) including removing spreading or stacking the spoil with in a lead of 75 m as directed .The item includes necessary a) Depth of excavation for additional depth beyond1,500 mm. and upto 3,000 mm. but not requiringshoring.
46Erection of Single tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportionand dimension indicated below), having 600 x 600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finishand GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly Upto 9.0 mtr. Size 0.6x0.6x1.70 mtrs
47Extra on items 1 & 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60 x 0.60 x 0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25cm x 25cm x 10cm GI Loop box, 16SWG & incl. drilled hole in pole
48Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting250 x 250 x 100mm
49Supply and inter connection of power line from light fixture to jointing box by the 1.5 sq mm x 2 nos pvc insulated HRFR 1.1 kv grade copper flaxible cable
50Supply and fitting fixing of 20mm dia GI pipe Medium quality (TATA) from muffing to Joint box
51Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 2 core 6 sqmm cable
52Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :i) 2 core 6 sqmm cable
53Wire net fencing 1.22Mtr high, on ground approximately 2mtr x 2mtr area and 1mtr wide Gate with Iron angle support at least 9 nos ISA65 medium
54Brick pillar support for the 50mm Φ Valves and fittings along with suitable size brick work for protection of the tube well base and Bordering of the Fencing at least 150mm from the GL including supply of necessary materials and neat cement punning to complete the job as per direction of E. I. C.
55Installation of the above pumping machinery by derrick arrangement by necessary jointing materials and interconnection of the submersible cable and power cable with outdoor type panel through cable protection pipe and specials including necessary brick pillar support for the Net fencing, gate etc
56Supplying and erecting in position mild steel (as per IS800,808 and other relevant code) Supporting structure, MS plate (3.55mm thick) at top platform ( 2.1mtr *2.1 mtr) including M.S. ladder (suitably placed), for supporting PVC tanks ( including supply of 5000 ltr capacity PVC/HDPE tank of approved quality with close top with lid (Black) -Multilayer as shown in the drawing )and all necessary pipe line connection with all PVC pipes from tubewell to delivery specials,valves all complete as per approved drawing and specefication and direction of Engineer-in-Charge.(minimum weight 1050kg) Reinforcement should be tor steel/Mild steel. Sail/TATA/RINL.
57Supplying , fitting and fixing PVC pipes for undergrond work of approved make of Schedule 80 (medium duty) conforming to ASTMD-1785 and threaded to match with GI pipes as per IS:1239 (Part-I), With all necessary accessories, specials viz. socket, bend tee, union cross, elbo, nipple, long screw, reducing socket, reducing tee, short piece etc. fitted including cost of all mateials jointing materials, cutting pipes, making threads, cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.)
5840mm dia
5932mm dia
6025mm dia
6115mm dia
62Laying Rising main, delivery main, Over flow, wash out pipe line with supplying, fitting, & fixing PVC pipes of approved make (Medium duty) conforming to ASTMD-1785 schedule-80 and threaded to match with G.I. pipes as per IS: 1239 (Part-I) with all necessary accessories, specials, viz socket, bend, tee, union, cross, elbow, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, as required, jointing matterials and two coats of painting with approved paint in any position above ground to feed the water nearest to houses at least one habitation to get water through stand post and complete the all works as per drawing & direction of the E.I.C. (Suggested brand:- Supreme/Ori Plast/Long last). (Payment will will be made on the centre line measurement of the total pipe line including all specials. No separate payment will be made for accessaries, specials) a) 50mm PVC (ASTMD)
63Construction of R.C.C street stand post with platform and 1.00 mtr masonry drain etc with ordinary cement concrete M-15 (mix 4:2:1) with 20mm down local hard stone (crusher broken) including plastering 20mm (6:1) with neat cementing to platform & drain as per dept type & drain as per dept type drawing and design including tapping the distribution main, supplying, fitting fixing 15mm brass ferule with necessary saddle piece with 20mm Ф G.I Pipes of approved make with specials and nipple, bib cock, reducing socket etc. all complete as per direction of E.I.C
64Construction of masonry drain attached to platform of RCC Street stand post with 12.5 cm thick brick work in cement mortar (1:4) over a layer of single brick flat soling with sand filling 150mm thick with WCC (6:3:1) with picket pieces (30mm size) including excavation of Earth, 15mm thick cement plaster (4:1) with neat cement punning all complete chamfering the edges as per drawing and direction of E. I. C.
65Surface dressing and preparation of the ground and removal of vegetation Single brick flat soling of Picket bricks including ramming and dressing bed to required level and filling joints with local sand
66Ordinary cement concrete (1:2:4) with graded stone chips (20mm Pakur variety) without any reinforcements on the brick soling area upto a thickness of 50mm
67Supply and laying of Vitrified Chequered Tiles size not less than 600mm x 600mm x 10mm thick of best quality with 20mm thick sand cement mortar (4:1) and 2mm thick cement slurry on the edges and finishing of the edges.
68Making double Earthing arrangement in complience with I.E rules by G.I pipe electrode with G.I funnel (50mmx 3 mtrlong) direcrt ground with supplying and fixing of G.I earth busbar drawing of 25mmx 6mm G.I earth conductor between pits and as earth busbar inside the pump house and 20mmx 3 mm GI strips for continuty to different electrica; installation i.e main switch panel and feeder box etc and making suitable size earth pit etyc all complete.For MCC Panel
69Painting of the entire installations by thorough scrapping of the metal surface and application of 2 coats of epoxy based primer and 2 coats of epoxy based outdoor type paint as per direction of E. I. C.
70Testing commissioning of the whole system as per direction of E. I. C.
71Add: 18% GST
72Add: 1% Cess Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57341340
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 18-09-2026
Authority
Authority Name Public Health Engineering Department
Work Description Tender for Construction Of 200 Mm X 165 Mm X 200 Mtr Depth. Rig Bored Tube Wells And Providing And Installation Of Submersible Pumping Machineries Along With Other Allied Electromechanical Works For Mini Water Supply Scheme At Ghatusole Village Of Fulkushma Gp,Raipur Block In The District Of Bankura Under Bankura Mechanical Division Phe Dte.
Basic Detail
Tender No WBPHED//BMD/NIeT- 05 OF 2026-2027
Bidding Type Tender
Location
City Bankura
State West Bengal
Key Dates
Publish Date 03 Sep 2026
Submission Date 18 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 29000
Exemption Available
Document List
1ae84d39-034d-4777-8b75-d9b4594fa606.html
BOQ_5100432.xls
Tendernotice_1 (37).pdf
Tendernotice_2 (4).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

1ae84d39-034d-4777-8b75-d9b4594fa606.html

xls

BOQ_5100432.xls

pdf

Tendernotice_1 (37).pdf

pdf

Tendernotice_2 (4).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders