Tender For Provision Of Klp At Dibrugarh Under Ge Dinjan.
Tender Value
99.93 Crore
Estimated cost
Bid Submission
10 Oct 2026
12 days left
EMD
15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tinsukia → Assam
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Provision Of Klp At Dibrugarh Under Ge Dinjan.
BOQ
| Sl. No. | Item Description |
| 1 | \\" BOQ \\" BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : Chief Engineer Shillong Zone NAME OF WORK: PROVN OF KLP AT DIBRUGARH UNDER GE DINJAN. Contract No: CESZ/DIN/ OF 2026-2027 Bidder Name : GENERAL SUMMARY (SCHEDULE OF WORKS) (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # NUMBER # Sl.No. Description of Parts/ Item Item Code / Make No. orQty. Unit Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT in Figure TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | NOTE:- (Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. |
| 3 | SCHEDULE 'A' PART I(A) DESIGN & BUILD STRUCTURENOTE: THIS SCHEDULE IS NOT PRE-PRICED BY MES AND THE PRE-PRICED RATE INDICATED AS \\"RS 0.00\\" UNDER COL. 5 SIGNIFIES THIS FACT ONLY. |
| 4 | Design & Construction of office and Admin building for BN HQ, RIF Coy and SP Coy complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 5 | Design & Construction of car and scooter parking shed for Admin building complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 6 | Design & Construction of Single living Accn for 04 RIF Coy, BN Coy and SP Coy , Drying and ironing room, Guard house, Anciliaries, Tradesman Shop and Stilt Park complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 7 | Design & Construction of car and scooter parking shed for Ors single living Accn complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 8 | Design & Construction of Storage Accn for four RIF Coy and station store complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 9 | Design & Construction of Storage Accn for four RIF CoyCook house and dinning Hall for ORs complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 10 | Design & Construction of Single living Accn for JCOs (13 Nos) and parking for 13 JCOs complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 11 | Design & Construction of JCOs Mess and Club for 13 JCOs complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 12 | Design & Construction of Armouries and Armourer shop complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 13 | Design & Construction of Religious Institute complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 14 | Design & Construction of Single Officers Accn for 08 Nos of officers complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 15 | Design & Construction of Open parking shed for 08 Nos of officers single living Accn complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 16 | Design & Construction of Officer's Mess complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 17 | Design & Construction of Jeep / Gypsy parking shed for officer's Mess complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 18 | Design & Construction of Servant Qtrs for pfficers Mess complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 19 | Design & Construction of 'B' Vehicle open parking shed complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 20 | Design & Construction of Repair bay complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 21 | Design & Construction of MT Store, MT driver standby, Technical office and battery charging room/ shop, Sanitary Annex complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 22 | Design & Construction of Multipurpose hall complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 23 | Design & Construction of Watch tower (09 staging) complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 24 | Design & Construction of MI Room complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 25 | Design & Construction of Scooter and cycle shed for MI Room complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 26 | Design & Construction of ORs Institute complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 27 | Design & Construction of Unit run canteen complete all as specified in tender document , as shown on Line Plan and as shown on approved drawing. |
| 28 | Design & Construction of RCC Over Head Tank 50000 UK Gallon Capacity complete all as specified in tender document and as shown on Line Plan and as shown on approved drawing. |
| 29 | SCHEDULES PREPRICED ON SSR |
| 30 | Lumpsum price worked out by the tenderer for BUILDING & STRUCTURES WORKS as listed in Schedule ‘A’ Part-I(B) |
| 31 | Lumpsum price worked out by the tenderer for SITE CLEARANCE, SITE DEVELOPMENTS & EARTH WORKS as listed in Schedule ‘A’ Part-II |
| 32 | Lumpsum price worked out by the tenderer for ROAD, PATH & CULVERT as listed in Schedule ‘A’ Part-III |
| 33 | Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-IV |
| 34 | Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-V |
| 35 | Lumpsum price worked out by the tenderer for SECURITY FENCING AND GATE as listed in Schedule ‘A’ Part-VI |
| 36 | Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-VII |
| 37 | Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-VIII |
| 38 | Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IX |
| 39 | Lumpsum price worked out by the tenderer for SEWAGE TREATMENT PLANT as listed in Schedule ‘A’ Part-X |
| 40 | Lumpsum price worked out by the tenderer for LIGHTNING PROTECTION as listed in Schedule ‘A’ Part-XI |
| 41 | Lumpsum price worked out by the tenderer for SUMMER COOLING APPLIANCES as listed in Schedule ‘A’ Part-XII |
| 42 | Lumpsum price worked out by the tenderer for AIR CONDITIONING as listed in Schedule ‘A’ Part-XIII |
| 43 | Lumpsum price worked out by the tenderer for HOT WATER SUPPLY as listed in Schedule ‘A’ Part-XIV |
| 44 | Lumpsum price worked out by the tenderer for DG SET as listed in Schedule ‘A’ Part-XV |
| 45 | Lumpsum price worked out by the tenderer for LIFT as listed in Schedule ‘A’ Part-XVI |
| 46 | SCHEDULE 'A' PART-XVII (MISCELLANEOUS ITEMS) NOTE: THIS SCHEDULE IS NOT PRE-PRICED BY MES AND THE PRE-PRICED RATE INDICATED AS \\"RS 0.00\\" UNDER COL. 5 SIGNIFIES THIS FACT ONLY. |
| 47 | M&L for construction of open shed 15 m x 5 m x 3 m, including earthwork excavation, PCC (1:3:6) type C2 for embedding angle iron post, Angle iron post of size 50 mm x 50 mm x 6 mm 12 Nos, PCC (1:4:8) type D2 as in foundation, PCC block masonry, 15 mm thic rendering in cement mortar (1:4), two coats cement base paint over a coat of cement primer,15 cm thick sand filling under floor, 15 cm thick hardcore, 100 mm thick sub base with PCC(1:4:8) type D2, 100 mm thick flooring with PCC(1:2:4) type B2, angle iron roof truss with size of angle 40 mm x 40 mm x 5 mm 05 Nos, gusset plates, required nut bolts, pre painted galvalume sheet roofing 0.50 mm thick, required Nos of purlin of angle iron of size 40 mm x 40 mm x 5 mm and two coats of synthetic enamel paint over a coat of red oxide primer on steel surface complete all as specified and directed. |
| 48 | Supply, Installation, testing and commissioning of Package type/ unitised 11KV/433V Outdoor Sub-station, 500 KVA made from GI enclosure cpmplete as required confirming to IEC 62271-202 only and relevant IS specifications including K-10 temperature class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 PCC foundation of suitable size extending 500mm all around the outdoor enclosure and 1000mm height (above the ground level ) complete with suitable sizes of GI pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40X40X5 mm MS all along with the corner of the foundation od CSS shall be from OEMs only. Licensed System Integrators of approved OEM are not allowed to supply .Package Substaion will have the following equipment :-HT Swichgear :-11 KV 630 Amps 21 KA / 3 Sec Non Extensible Ring Main Unit Compact Switchgear consisting of direct cable module & 1 No motorized Circuit Breakers Module in SF6 insulated stainless enclosure with series trips, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall perferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through IC x 95 sq. mm Aluminium XLPE cable - 1 No. |
| 49 | Serial item No. 3.02 continued.....Vacuum Interrupter & RMU shall be of same make to ensure life cycle optimization. Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along wtih series trip coil (Modbus RS485 complaint.Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.SF6 Gas pressure indicator.Operating sequence of VCB must be O-0.3sec-CO-3 Mins CO - Protection CT shall be minimum 40/1A, 2.5VA, 5P10 - 3 nos. All modules of the RMU shall be suitable for cable termination of 3C x 95 Sq.mm AI XLPE Cable, incoming cable termination is included within the scope of work - 1 setTRANSFORMER: -11/0.433KV, 500 KVA, 50Hz, Off load Tap Changer switch, Three Phase, natural ester oil type transformer in corrugated tank(i) Standard IS : IS : 2026 and IS 1180 with latest amendments (2021). (ii) Losses as per 1180 level 2 and Temperature rise shall be as per IS 1180 with latest amendments. (iii) Outdoor Installation. (iv) Vector group : Dyn 11. (v) Rating 500 KVA. (vi) Cooling System : KNAN (K for Ester oil). (vii) Winding ; Copper. (viii) Magnetic Core : Prime grade of M4 or better. (ix) High voltage : 11 KV - 50 Hz. (x) Low Voltage : 433 V - 50Hz. (xi) System highest Voltage : 12 KV at the HV side. (xii) Percentage Impendance Value : As per IS 1180. (xiii) Manufacturer shall have NABL accredited testing labotatory.(xiv) Insulation Level : HV Power Frequency (KV rms) : 28 KV, HV, Impulse withstand voltage (KV peak) : 75 kVp. (xv) Tapping : +5% to -15% OLTC @ 2.5%. (xvi) HT Termination - Cable Boxxvii) LT termination - cable box and with all accessories i.e. first filling of filtered dehydrated oil and confirming to ID & standard accessories required (xviii) OEM shall have in house core cutting facility for proper control & monotoring of quality & to avoid mixing of prime core with second grade / defective core materialsLT PANELLVS PANEL 1200 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminium as 1 A./sq.mm; LT panel made up of 1.5/2 mm thick CRCA sheet.INCOMER FROM TRANSFORMER800 Amps 433 V 50 Hz 50 KA draw out Type Microprocessor Release based MCCB - 01 No. |
| 50 | Serial item No. 3.02 continued.....Meter of Class 0.5 S ,415 V, 50 Hz, 1b 5A complete all as specified. The meter shall communicate with Head existing End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I in a secure manner. The selection of communication technology should be as per the site conditions and as per existing AMR infrastructure available in the station. The smart meter may be based on RF Mesh communication technology or Cellular communication technology as per site requirements with transparent polycarbonate ABS thermoplastic box with sealing arrangements of suitable size as per the requirement of OEM of Electric meter. The cost of meter would include the supply of current transformer, Rated burden 15 VA, Accuracy class 0.5 S, frequency 50 Hz and voltage class 660 V effectively earthed and CT ratio suitable as (600/5) complete - 01 NoOUT GOING :- Microprocessor based MCCB 630 A, 36 KA, 4 Pole - 02 Nos (For FP- 2 & Spare) Microprocessor based MCCB 300 A, 36 KA, 4 Pole - 01 Nos (For FP-1) Microprocessor based MCCB 250 A, 36 KA, 4 Pole - 02 Nos (For FP-3 & FP-4) Microprocessor based MCCB 100 A, 36 KA, 4 Pole - 0 Nos (For FP-5) 150 KVAR APFC panel with minimum 6 steps as per following tentive steps (50 KVAR X 1, 25 KVAR X 2, 20 KVAR X 1, 10 KVAR X 2 & 5 KVAR X 2)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturer's recommendation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type enclosure of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable designed for better heat dissipation and providing robust construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitably handling any arcing inside the compartment illumination lamp with door operated switch shall be provided for each compartment. |
| 51 | S&F drop out fuse unit expulsion type for outdoor air brake gang operated switches single pole mounted and including insulator for 11 kV working pressure fixed to and including MS channel with nuts, bolts, washers etc. synthetic bounded fuse carrying tube complete with line taps and suitable for current carryout capacity upto 25 Amps complete all as specified and directed. |
| 52 | M&L for Loop in loop out box of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit , combi climate cable glands of IP 66 / 67 for cable entry and grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10 kA,C curve overload and short circuit protection, terminals as PVC connector heavy duty 32 Amps, 4 way for cable necessary fixing arrangements and with cable glands ,etc all as specified and directed. |
| 53 | S&F lay cable PVC insulated industrial flexible FR 1100 volt grade with stranded copper conductor of size 1.5 sqmm 3 core in suitable PVC conduit complete all as specified and directed. |
| 54 | Supply and fix for precast PCC cable route indicator duly marked and painted for HT/LT cables of size 80x25x7.5 cm with suitable size of base, embossed with lettering \\"MES HT Cable\\" complete all as specified and directed. |
| 55 | M&L for horizantal boring/drilling hole mannual under the road in soft/loose soil without cutting/disturbing the existing road and inserting GI pipe 80/50/40/32mm bore for drawing the cables complete all as directed and specified.Note:(i) Cost of acessories required for making hole/bore deemed to be included in the quoted rate.(ii) GI pipe shall be measured and paid separately under respective item. |
| 56 | Fabrication, supply, installation, testing and commissioning electrical cubical control panel board an ISO: 9001 factory assembled made out door pedestal type feeder pillar box wheather and vermin proof fabricated of 3.0 mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB's including and mounting measuring instrument such as Volt meter, Ammeter,CT's, Phase indicator lamps including incoming and outgoing cables connections with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded upto 30cm complete all as specified and directed. (Panel -1)(Feeder piller box shall be consisting the following)(a) 4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated suitable for 400 Amp with provision of extension and mounting on porcelain support |
| 57 | Serial item No. 3.08 continued.....(INCOMING )(a) MCCB FP 250 amps, 36 KA , 415 volts, Thermal magnetic release 50Hz = 01 No(OUTGOING)(a) MCCB FP 200 amps, 36 KA , 415 volts, Thermal magnetic release 50Hz = 01 No(b) MCB TPN C curve 6-32A - 05 Nos(c) Time switch 415 V ,triple phase of max 63 Amp rated.-02 Nos(d) Power contactor 04 pole 63 A - 02 nos(e) Insulated Aluminium bus bars of suitable size shall be provided from the main bus bar to the out going MCCBs.(f) RYB indicating lamp, LED type 01 set.(g) Drawing shall be approved by GE before placing the order. |
| 58 | Fabrication, supply, installation, testing and commissioning electrical cubical control panel board an ISO: 9001 factory assembled made out door pedestal type feeder pillar box wheather and vermin proof fabricated of 3.0 mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB's including and mounting measuring instrument such as Volt meter, Ammeter,CT's, Phase indicator lamps including incoming and outgoing cables connections with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded upto 30cm complete all as specified and directed. (Panel -2 )(Panel box shall be consisting the following)(a) 4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated suitable for 800 Amp with provision of extension and mounting on porcelain support |
| 59 | Serial item No. 3.09 continued.....(INCOMING)(a) MCCB FP 500 amps, 50 KA , 415 volts, Thermal magnetic and microprocessor release 50Hz = 01 No.(OUTGOING)(a) MCCB FP 400 amps, 50 KA , 415 volts, Thermal magnetic release 50Hz = 01 No (b) MCCB FP 125 amps, 36 KA , 415 volts, Thermal magnetic release 50Hz = 01 No (c) MCCB FP 63 amps, 36 KA , 415 volts, Thermal magnetic release 50Hz = 01 No (d) MCB TPN C curve 40A - 02 Nos(e) MCB TPN C curve 6-32A - 02 Nos(f) Insulated Aluminium bus bars of suitable size shall be provided from the main bus bar to the out going MCCBs.(g) RYB indicating lamp, LED type 01 set.(h) Drawing shall be approved by GE before placing the order. |
| 60 | Fabrication, supply, installation, testing and commissioning electrical cubical control panel board an ISO: 9001 factory assembled made out door pedestal type feeder pillar box wheather and vermin proof fabricated of 3.0 mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB's including and Mounting measuring instrument such as Volt meter, Ammeter , Selector switchs, CT's, Phase indicator lamps with holder , toggle switches and backelite fuse cut outs etc including incoming and outgoing cables connections with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded upto 30cm complete all as specified and directed (Panel -03)(Feeder piller box shall be consisting the following)(a) 4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated suitable for 300 Amp with provision of extension and mounting on porcelain support |
| 61 | Serial item No. 3.10 continued….(INCOMING)(a) MCCB FP 200 amps, 36 KA , 415 volts, Fixed thermal magnetic release 50Hz = 01 No(OUTGOING)(a) MCCB FP 80 amps, 35 KA , 415 volts, Fixed thermal magnetic release 50Hz = 01 No (b) MCCB FP 63 amps, 35 KA , 415 volts, Fixed thermal magnetic release 50Hz = 01 No (c) MCB TPN C curve 40A - 03 Nos (d) MCB TPN C curve 06-32A - 01 No (e) Time switch 415 V ,triple phase of max 63 Amp rated.-01 No(f) Power contactor 04 pole 63 A - 01 no(g) Insulated Aluminium bus bars of suitable size shall be provided from the main bus bar to the out going MCCBs.(h) RYB indicating lamp, LED type 01 set.(k) Drawing shall be approved by GE before placing the order. |
| 62 | Fabrication, supply, installation, testing and commissioning electrical cubical control panel board an ISO: 9001 factory assembled made out door pedestal type feeder pillar box wheather and vermin proof fabricated of 3.0 mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB's including and Mounting measuring instrument such as Volt meter, Ammeter , Selector switchs, CT's, Phase indicator lamps with holder , toggle switches and backelite fuse cut outs etc including incoming and outgoing cables connections with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded upto 30cm complete all as specified and directed (Panel 4 ) |
| 63 | Serial No. 3.11 continued....(Feeder piller box shall be consisting the following)(a) 4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated suitable for 300 Amp with provision of extension and mounting on porcelain support (INCOMING)(a) MCCB FP 200 amps, 36 KA , 415 volts, Fixed thermal magnetic release 50Hz = 01 No(OUTGOING)(a) MCCB FP 63 amps, 36 KA , 415 volts, Fixed thermal magnetic release 50Hz = 03 Nos (b) MCB TPN C curve 6-32A - 02 Nos(c) Insulated Aluminium bus bars of suitable size shall be provided from the main bus bar to the out going MCCBs.(d) RYB indicating lamp, LED type 01 set.(e) Drawing shall be approved by GE before placing the order. |
| 64 | Fabrication, supply, installation, testing and commissioning electrical cubical control panel board an ISO: 9001 factory assembled made out door pedestal type feeder pillar box wheather and vermin proof fabricated of 3.0 mm CRCA MS sheet of Suitable size,3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB's including and Mounting measuring instrument such as Volt meter, Ammeter , Selector switchs, CT's, Phase indicator lamps with holder , toggle switches and backelite fuse cut outs etc including incoming and outgoing cables connections with suitable cable glands, lugs including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron size 50x50x6mm welded on all four corner embedded in PCC (1:2:4) using 20mm graded upto 30cm complete all as specified and directed (Panel 05 )(Feeder piller box shall be consisting the following)(a) 4 Nos electrolytic aluminium bus bars high conductivity aluminium alloy proper insulated suitable for 100 Amp with provision of extension and mounting on porcelain support (INCOMING)(a) MCCB FP 63 amps, 36 KA , 415 volts, thermal magnetic release 50Hz = 01 No. (b) RYB indicating lamp, LED type 01 set. |
| 65 | Supply & fixing bollard light fitting 08 Watt 1 mtr with IP 65 protection for illumination at garden light complete all as specified and directed. |
| 66 | Supply & installation of Galvanized Steel High Mast lighting system for 16 meter hight mast in two shafts with 20 sided polygon cross section (top 166 mm & bottom 410 mm bore min) and sheet thickness 3mm for top & 4 mm for bottom (min), hot dip galvanised (confirming to IS 4270) and suitable for wind velocity as per IS 875, Part-III with all it's standard accessories including head frame, luminaries carriage size of base plate should be Suitable to install 08 Nos 150 Watt light fittings and double drum winch with 3 Nos steel wire rope system of min 6 mm dia, 4.0 sqmm 6 core trailing cable with copper conductor, connectors, integral power tool motor of suitable capacity with rising/lowering mannual system comprising of handle, junction box, lightning, anchoring, foundation bolts size M24 X 1200 mm, Aviation Obstruction Light (AOL) fixing arrangement and other accessories.Note:(i) Excavation, RCC foundation as per the approved design of OEM shall be measured and paid separetly under respective item. (ii) Material Specifications (b) Foundation Bolt : IS 2062/E250A (c) Base Plate : IS 2062 (d) Galvanisation : IS:4759/2629 & ASTM A123 |
| 67 | Supply , installation, testing and comission of Smart energy prepaid Meter confirming to IS-16444: 2015 (Reaffirmed 2020) and as ammended time to time, AC whole current, three phase, 4 wires Smart Energy Meter of rating 415 Volt, 10-100 Amps,50 Hz , Class 1, enclosed in polycarbonate box complete as specified in CEA notification. The meter shall communicate with Head End System (HES) on any of the communication technologies mentioned in IS-16444 Part-I. The slection of communication technology should be as per the site conditions and as per design consideration of AMI Implementing agency to meet the performance. The smart meters should be based on RF Mesh communication technology or Cellular communication technology and carry min 5 yrs warranty complete all as specified and directed. |
| 68 | Supply, laying, connection and testing 150 mm bore, ductile iron pressure pipe centrifugally cast (spun) with spigot and socket ends, class K-9 and confirming to IS 8329 - 2000 with push on rubber gasket jointing inside with cement mortar lining and outside zinc coating with finishing layer of black bitumen/blue epoxy coating duly ISI marked in any length laid in trenches complete all as specified and directed. |
| 69 | Supply, laying, connection and testing 200 mm bore, ductile iron pressure pipe centrifugally cast (spun) with spigot and socket ends, class K-7 and confirming to IS 8329 - 2000 with push on rubber gasket jointing inside with cement mortar lining and outside zinc coating with finishing layer of black bitumen/blue epoxy coating duly ISI marked in any length laid in trenches complete all as specified and directed. |
| 70 | Supply, laying, connection and testing 150 mm bore, ductile iron pressure pipe centrifugally cast (spun) with spigot and socket ends, class K-7 and confirming to IS 8329 - 2000 with push on rubber gasket jointing inside with cement mortar lining and outside zinc coating with finishing layer of black bitumen/blue epoxy coating duly ISI marked in any length laid in trenches complete all as specified and directed. |
| 71 | Supply, laying, connection and testing 100 mm bore, ductile iron pressure pipe centrifugally cast (spun) with spigot and socket ends, class K-7 and confirming to IS 8329 - 2000 with push on rubber gasket jointing inside with cement mortar lining and outside zinc coating with finishing layer of black bitumen/blue epoxy coating duly ISI marked in any length laid in trenches complete all as specified and directed. |
| 72 | M&L for construction of bricks masonary valve pit chamber/ valve chamber of size 1020 mm x 1020 mm 1020 mm (internal) including necessary excavation and earth work and MS sheet cover 3mm thick and angle iron 50x50x6 mm frame including locking arrangements with lock and key of 50 mm lock duly painting of steel surface in two coat of synthetic enamal paint over one coat of red oxide primer complete all as specified and directed. |
| 73 | M&L for construction of bricks masonary valve pit chamber/ valve chamber of size 900 mm x 900 mm 900 mm (internal) including necessary excavation and earth work and MS sheet cover 3mm thick and angle iron 50x50x6 mm frame including locking arrangements with lock and key of 50 mm lock duly painting of steel surface in two coat of synthetic enamal paint over one coat of red oxide primer complete all as specified and directed. |
| 74 | M&L for drilling of trial bore of size 200 mm dia upto 180 mtr depth below ground at given site perfectly vertical with reverse rotory rig circulation method/ by direct rotary mechanical system or any latest technology through any kind of strata of the layers including hard stone/boulder etc to the complete depth including submitting the strata details duly graphically recorded for injection well in any kind of soil strata including hard stone/boulders including disposal of soil from the site complete all as specified and directed. |
| 75 | M&L for development of trial bore by reaming of bore well from 250 mm dia to 450 mm dia hole in two steps from 250 mm to 350 mm, 350 mm to 450 mm upto 60 m depth below the ground level from the top of ground including disposal of soil from the site complete all as specified and directed. |
| 76 | M&L for development of trial bore by reaming of bore well from 250 mm dia to 450 mm dia hole in two steps up to 450 mm for depth exceeding 60 m but not exceeding 180 m below the ground level from the top of ground including disposal of soil from the site complete all as specified and directed. |
| 77 | Supplying , assembling, jointing and lowering 7.1 mm wall thickness 250 mm dia ( internal ) ERW MS housing pipes, heavy duty conforming to SI-4270-2001 or IS-3589-2001 (steel tubes used for water wells) and fixing in position ( including necessary cleaning internal and external and painting inside of pipes with two coats of black bitumin paint suitable for drinking purpose ) in different depth as directed, plain ended, jointed heavy duty suitable size collar and 20x4 mm of suitable length MS flat iron contact guide in each joint ( 04 Nos of each joint) with butt welding joint complete surronding the pipe in both ends for development / expanding of trail bore for new borewell complete all as specified and directed |
| 78 | Supplying , assembling, jointing and lowering 5.4 mm wall thickness 200 mm dia ( internal ) ERW MS housing pipes, heavy duty conforming to SI-4270-2001 or IS-3589-2001 (steel tubes used for water wells) and fixing in position ( including necessary cleaning internal and external and painting inside of pipes with two coats of black bitumin paint suitable for drinking purpose ) in different depth as directed, plain ended, jointed heavy duty suitable size collar and 20x4 mm of suitable length MS flat iron contact guide in each joint ( 04 Nos of each joint) with butt welding joint complete surronding the pipe in both ends for development / expanding of trail bore for new borewell complete all as specified and directed |
| 79 | Supplying, assembling, jointing and lowering low carbon galvanized (LCG) steel strainer pipe ( slotted pipe ) 200 mm nominal bore of wall thickness 7.00 mm cage type wire wound screen ‘V’ shaped profile in suitable length having slots of size plain slotted pipe, type A, 1 mm slot openings conforming to IS-8110: 2019 and fixing in position in different depth as directed, butt welded complete all as specified and directed. |
| 80 | Supply assembling jointing and lowering 5.4 mm wall thick 200mm diameter (internal) ERW pipes, 6.00 m long, bail plug made by 200 mm diameter ERW pipe and one closed by 7 mm thick MS plate welded and fixing in position (including necessary cleaning internal and external surfaces and painting inside and outside of pipes with two coats of black paint suitable for drinking purpose) and fixed at bottom of casing Pipe plane ended jointed by suitable size socket with full welding complete sorrounding the pipes in both ends to make leak proof complete all as specified and directed. |
| 81 | M&L for development of tube well in accordance with IS 2800: 2019 and IS:11189 with compressed air method (open well method), till to get the clear water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed complete all as specified and directed. |
| 82 | M&L for yield test for the borewell by continuosly pumping for 16 hours to determine safe pumping yield and to establish maximum rate of usable water complete all as specified and directed. |
| 83 | S&F MS reducing socket 250x200 mm having thickness 6.0 mm wall thickness heavy duty with 20x4 mm MS flat iron centre guide 400mm long 04 No for jointing housing/ blank pipe of bore well including necessary welding work complete all as specified and directed. |
| 84 | S&F Well cap in two parts made out of MS plate 5mm thick for covering tube well (internal dia 250 mm x 100 mm depth) duly welded with locking arrangement , including making holes for passing 2 run of 10 sqmm flat submersible cable & one run of support chain complete all as specified and directed . |
| 85 | M&L for Disinfection of bore well as per IS 2800: 2019 using 200 milligrams of powdered chlorine compound per litre of water present in the well and left in the well for at least 8-12 hours to ensure elimination of any bacteria complete all as specified and directed. |
| 86 | Fabrication and supply of Strata sample wooden box, made out of 20 mm thick veneered particle board and partition with 12 mm thick plywood with job 1200 mm x750 mm with 10 partitions of size of 150 mm x150 mm, 100 mm deep with front glass sheet sliding type cover with almunium frame all round , 2 Nos key hole plate of size 40 mm x 25 mm x 3 mm thick, complete all as specfied and directed.Note:Name of tubewell,location,strata sample with depth shall be written on the sample box shall be as per direction of Engineer-In-Charge. |
| 87 | S&F galvanised steel wire rope multistrand of size 8 Sqmm as per ISO 4309:2019 and safe for carry a point load of 48.6 KN/ 5 Ton, for lowering of pump/column pipe, complete all as specified and directed. |
| 88 | Testing of water in connection with chemical and biological characterstic of water to be carried out by any approved approved / recognised laboratory as approved by GE complete all as specified and directed. |
| 89 | Supply , fix and laying PVC insulated, PVC sheathed 3 Core flat copper conductor,submersible cable 10 Sqmm size 1100 Volts grade including jointing with M-seal and connecting from pump set to loop in box starter with suitable size thimble and lugs and testing complete all as specified and directed. |
| 90 | Supply, install testing and commissioning of 100 mm dia C.I. flanged type venturimeter of length about 2 mtr in main pipe line with necessery nut bolt gasket etc for fixing of chlorine dosing NRV, measurning of flow complete all as specified and directed. |
| 91 | Fabrication, supply, installation, testing and commissioning electrical cubical control panel board an ISO 9001 factory assembled made In door type feeder pillar box weather and vermin proof fabricated of 2.0 mm CRCA MS sheet of suitable size, 3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB's including mounting measuring instrument such as Volt meter, Ammeter -01 No, Selector switchs, CT's -03 Sets, Phase indicator lamps, including incoming and outgoing cables connections with suitable cable glands, lugs including grouting of feeder pillar box complete all as specified and directed. (Feeder piller box shall be consisting the following)(INCOMING) (a) MCCB FP 100 amps, 25 KA , 415 volts, 50Hz = 01 No (OUTGOING) (a) MCCB FP 63 amps. 25 KA,415 volt,50 Hz = 01 No (Submersible pump)(b) Star Delta starter suitable for 25 HP submersible pump set = 01 No (c) Isolator /MCB TPN 32 amp = 01 Nos (d) Digital Panel mounted Amp meter 96 mm square type complete with selector switch complete with suitable size of CT's - 01 Set(e) Digital Panel mounted Volt meter 96 mm square type complete with selector switch - 01 Nos (f) RYB indicating lamp, LED type 01 sets.(g) PCC (1:2:4) type B1, using 20 mm graded crushed stone aggregate. |
| 92 | S&F Aviation obstruction light LED type filament-less bulb with 10 Watt bulb complete including standard fixing arrangements all as specified and directed |
| 93 | Supply , install , testing and commissioning of Iron Remval Plant outdoor for capacity of 45400 LPH/ 10000 GPH direct in- line type dual media filter system, activated carbon filter system to treat of raw water Fe containt 3.0 PPM and treated water should have less than 0.3 PPM with all necessary civil work for foundation, Pit for valve, hardstanding for operation and maintenance, drainage for backwash water upto suitable locaiton not more than 50 Mtr from IRP as per direction of Engr in Charge alongwith the parameters mentioned below (Rates quoted to be inclusive of all the above parameters) (i) OXIDATION CHEMBER WITH FRONTAL PIPING & VALVES, INLET & OUTLET PR. GAUGE- 01 NoVessel Dia- 1900 MM Vessel Height- 1500 MM Shell Thickness- 6 MM Disc Thickness- 8 MM Design Pr -3.5 Kg/cm2 Media- MNO2Painting- Internal Black Bituminus painted and outside 2 coat primer. Backwash Frequency- When DP more than 0.6 kg/cm2(ii). DUEL MEDIA FILTER WITH FRONTAL PIPING & VALVES, INLET & OUTLET PR. GAUGE- 01 NoVessel Dia- 2000 MM Vessel Height- 2000 MM Shell Thickness- 6 MM Disc Thickness- 8 MM Design Pr -3.5 Kg/cm2Media- Anthracite, Course Silex, Fine Silex, Filtering Sand, Crushed Gravels, Pebbles. Painting- Internal Epoxy painted and outside 2 coat primer.Backwash Frequency- When DP more than 0.6 kg/cm2 |
| 94 | Serial item No. 3.41 continued...(iii) IRON REMOVAL FILTER WITH FRONTAL PIPING, VALVES, INLET & OUTLET PR. GAUGE- 01 NoVessel Dia- 1900 MM Vessel Height- 1500 MM Shell Thickness- 6 MM Disc Thickness- 8 MM Design Pr -3.5 Kg/cm2Media- MNO2, Filtering sand, Pebbles, Gravels.Painting- Internal Black Bituminus painted and outside 2 coat primer. Backwash Frequency- When DP more than 0.6 kg/cm2(iv). DOSING PUMP with Agitator -02 No Capacity-0-10 LPH MOC-PP with neccessary electric connection and shed for dosing pump.(v). DOSING TANK-02 NOS MOC-HDPE/LLDP Capacity-200 Ltr(vi). PRESSURE GAUGE- 03 NOS MOC- GLYCERIN FILLED RANGE- 0-7 KG/CM2(vii). AIR COMPRESSOR- 01 NO , CAPACITY- 5 HP AIR FLOW RATE- 21 CFMNote :Price for Foundation of IRP alongwith drain shall deem to be included in quoted price |
| 95 | Supply, Install, testing and commissioning of Submersible pump, electric driven 415 V, TP suitable for 200/250 mm dia bore well (Casing pipe size 200/250 mm)Motor Power: 25 HP (18.5 kW) Pump Type: Submersible Pump Head Range: 36–50 m, Discharge Capacity: 1,000–2,100 LPM, Speed: 2,900 RPM, Outlet Size: 150 mm, Power Supply: 415 V, 3 Phase, 50 Hz, Protection: IP68, Insulation Class: F complete all as specified and directed. |
| 96 | Design, Supply, construction, installation, testing & commissioning of Sewage Treatment Plant of capacity 50 KLD based on principle of aerobic attached growth non clogging randomly Moving Bed Bio-reactor (MBBR) including the following as per OEM specifications to meet the desired output paramters.(a) One no. inlet chamber in MSEP construction with Fine bar screen of SS construction.(b) One no. Oil & Grease Trap chamber in MSEP construction(d) One no. Equalisation tank in MSEP construction with air grid(e) Two nos. raw sewage self priming centrifugal pumps complete with motor and all necessary accessories and fittings. Level sensor provided in the tank and interlinked with pumps for ON-OFF operation as per water level in the tank. One pressure gauge for each pump provided to measure pressure at the outlet.(f) Two nos. twin lobe type Air blower with motor, for providing air in equalization tank, MBBR reactors & Sludge holding tank. One no. Air rotameter is to be provided in each line to MBBR reactor 1 & 2, equalisation tank for measurement of quantity of air.(g) One no. anoxic chamber in MSEP construction with Mixer.(h) Two nos. MBBR tanks in MSEP construction with all internals comprising of media, air grid & riser pipe, media retaining sieves, etc.(j) Two nos. sewage centrifugal monobloc self-priming recirculation pumps complete with motor and all necessary accessories and fittings. One pressure gauge for each pump has to be provided to measure pressure at the outlet. |
| 97 | Serial item No. 3.43 continued....(k) One nos. tube settler tank in MS EP construction with media. (l) Two nos. sludge transfer self priming monobloc pumps complete with motor and all necessary accessories and fittings for transferring sludge from bottom of the tube settler to the sludge holding tank. One pressure gauge for each pump has to be provided to measure pressure at the outlet. (m) One no. Sludge Holding Tank in MSEP construction. (n) One no. Chlorine Contact cum Filter feed tank in MS EP construction. (o) One set of Sodium Hypo Chlorite dosing system comprising of 2 nos. dosing pump and one no. Solution tan. (p) Two nos. filter feed centrifugal monobloc pumps complete with motor and all necessary accessories and fittings for feeding tertiary unit, Level sensor should be provided in the chlorine contact cum filter feed tank and interlinked with pumps for ON-OFF operation as per level in the sump. One pressure gauge for each pump has to be provided to measure pressure at the outlet. (q) One no. Dual Media filter, complete with media, frontal piping, valve and pressure gauges to measure pressure across the filter. (r) One no. Activated Carbon Filter of complete with media, frontal piping, valve and pressure gauges to measure pressure across the filter. (s) Two nos. sludge transfer self priming monobloc pumps complete with motor and all necessary accessories and fittings for sludge screw press , Level sensor should be provided in the sludge holding tank and interlinked with pumps for ON-OFF operation as per level in the sump. One pressure gauge for each pump has to be provided to measure pressure at the outlet. (t) One no. sludge bag system with static mixer and DWPE dosing system for sludge dewatering system as specified in PS (u) One no. Treated Water Tank in MS EP construction for back wash of filters. (v) One no. electrical control Panel for operation of all electromechanical units of sewage treatment plant. (w) One lot of suitable size Piping & valves of suitable material to interconnect various units of sewage treatment plant, as per approved drawings(x) One lot of Power & control cables to interconnect various drives and instrumentations with STP panel. |
| 98 | Supply, Installation Testing & Commissioning of outdoor type PLC (Programmable Logic Controller ) / RTU (Remote terminal Unit) based Automation, Protection Panel for Lift Well with feature of Dual mode communication i.e. wireless Dual SIM Card based communication and wireless Radio Frequency based communication (The module should be programmed to automatically toggle between the two communication mode based on the actual signal strength available), suitable for control and monitoring of 03 Nos. Pumps, 1 No. Energy Meters, 01 No Ultrasonic sensor, 01 No electromagnetic flow meter. The panel should be of suitable size, front opening type, fabricated from 2.0 mm thick CRCA Sheet & mounting channel 40x40x5mm made out of Angle iron with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FRLS cable of adequate size. |
| 99 | Serial item No. 3.44 continued....(i) The Panel should be capable of performing following functions in Lift well all as specified and directed:- (a) Time & level based operation of lift well pumps. (b) Automatic duty cycle based operations of Pumps (c) Auto Change Over In Case of Pump Failure (d) Single Phasing Prevention, phase sequence corrector, voltage unbalancing protection. (e) Manual Mode Operation (all connected sub systems & operations in Sewage treatment plant) from the PLC/ RTU based Control Panel. (ii) The panel shall have 01 No. PLC/ RTU with following specifications:- (a) Discrete Input Logic (b) Should have suitable No. of Discrete Input and Discrete Output: - Relay/Transistor (c) Protocol supported : isolated serial/ TCP link: Modbus master/slave and DNP 3.0 (d) Standard supported :- ANSI/ISA 12-12-01, CSA C22.2 No 142, CSA C22.2 No 213, EN/IEC 61131-2:2007 (e) Web Services: - Integrated Web Server (f) 02 Nos. isolated RS 485 communication port, 1 Nos. Ethernet communication port with 10BASE-T/ 100BASE-TX. (g) Number of Slave: - 64 Modbus TCP, & adequate DNP - 3 master slaves. (h) PLC/RTU shall be certified by NABL for electromagnetic compatibility and radio disturbance standards as per CISPR22, IEC 61000-4-2:2008, IEC61000-4-3:2010, capable of sending data to multiple route and on precise location. (j) Contractor shall consider in quoted rates for any changes in logic within 5 years of installation as per requirement of department. (k) Certified with IEC62443 (iii) Suitable number of indicating LEDs on the panel. |
| 100 | Serial item No. 3.44 continued....(iii) Suitable number of indicating LEDs on the panel.(iv) 01 No. SMPS of 6.5A rating (or higher) as suitable according to Panel design. (v) Suitable No. of interposing relays of 220VAC or 24VDC coil rating and 4A contact rating. (vi) Suitable No. of relay cards with operating voltage 24VDC, with continuous current of 5A. Card must be of 8 channel & having 8 relays. (vii) Suitable No. of MCB rating 32A/ 25A/ 10A/ 6A.(viii) Suitable No. of Illuminated push button & indicator lamp (ix) Suitable No. of Selector switches, Audio visual alarm indicator: - As per requirement (x) 01 No. Industrial Ethernet Switch with 5 Nos. RJ45 Ports, 10/100 Mbps Transmission Speed. (xi) LTE router/modem GPRS enabled and having following configuration as minimum:- (a) Ethernet Port /RJ45/ RJ232 or inbuilt in RTU (Remote Terminal Unit) (b) Security - Zone based firewell, VLAN, DMZ, HTTPS local & remote or inbuilt in RTU (Remote Terminal Unit). (c) Communication protocols - Modbus PLC/RTU to TCP support, Modbus master mode or inbuilt in RTU (Remote Terminal Unit). (d) Routing - DHCP, static routing, port forwarding, traffic routing, static/dynamic DNS, DNS proxy. (e) Operating Voltage Range - 24 V DC, +/- 5% (f) Dual SIM (one stand by) Via two SIM. |
| 101 | Serial item No. 3.44 continued....(xii) Sewage Pump Control Panel (A) Control panel shall be equiped with fully automatic starters designed to operate pump motors and shall have provision to mount MPU (provided by Lift Well Non Clogging Pump) : - Voltage : 415 V ± 10 %, Frequency : 50 Hz ± 5 %, Phases : 3 Phase + Neutral, Class of duty : Continous, Class of insulation ; F, Ingress Protection IP 54, (a). Automatic Starter : Direct on line (DOL) or Star delta starting (SDS) as per OEM recommendation (b). Suitable capacity and rating MPCB as per OEM recommendation (c). Multifunction Meter with RS 485 Port (d). Push buttons for pump start, stop with indication (e). Auto / Off / Manual selector switch (xiii) Motor Protection Unit (MPU) MPU shall be provided by OEM to suite the thermistor and moisture sensor in the pump. Contractor shall be responsible to mount MPU unit in his starter control panel and to intigrate with starter. The space for the same shall be provided in outdoor control panel after consulation with pump set OEM. Features of MPU : Disply features on: LED for indications of following. (i) Oil contamination (ii) low liquid level (iii) High temperature of the motor winding (iv) Low / High Voltage / Rev Phasing / Single Phasing (v) Over loading of Motor.FlangesStandard drilling to IS 6392 table 15 |
| 102 | Supply , installation, testing and commissioning of ultrasonic level transmitter for lift well service, 0-6 m range, blind zone <0.30 m, accuracy <+5 mm or <+0.25% span (Whichever greater), beam angle <100, response <1 s, temp compensation, damping and false-echo suppression, 4-20ma isolated output with local LCD, 18-30 V DC supply, IP66/67 housing with PP/PVDF face include SS304/316 top plate or bracket with vertical alignment, vented stilling well 100-150 mm ID with base slots and top screen where turbulence/foam exists, field JB IP66 with DIN TB and earth stud, shielded instrumentation cable 2C x1.5 mm2 with UV conduit and glands, 24 V DC Class-III SPD at panel, earthing with 6 sqmm Cu, setup and commissioning (range/zero to site datum, damping 5-10s, false-echo teach, alarm set points), and hand-over of datasheet, calibration certificate, echo profile, wiring diagram and O & M approved makes. |
| 103 | Supply , installation, testing and commissioning of full-bore electromagnetic flow meter, DN 80 (PN10), liner hard bubber, EPDM or PTFE, electrodes SS316L/Hastelloy_C, accuracy<+0.5% of MV, repeatability <+0.2& MV, empty-pipe detection, 4-20 mA and RS-485 Modbus-RTU, local LCD totalizer, isolation >1.4 kV, transmitter IP67, flowtube IP68 if pit-mounted, power 90-250 VAC 50 Hz; including cutting the existing DN_pressure line, inserting matching DN flanged spool(s) to secure >5D upstream and >3D downstream straight runs (or flow-conditioner), providing earth/grounding rings where required, welding, fit-up with EN 1092 flanges, gaskets, bolts, supports, cabling to panel, surge protection, hydro-test, calibration certificate, and making good, complete all as specified and directed.Size notes:DN40: typical line 1 ½ “-2”. Prefer wafer or short – face flanged meter.DN50: most common for ~50 LPM@20 m pumps; check velocity 05-3m/s at duty DN65: use when existing header is 65 mm; keep velocities < 3 m/s |
| 104 | Supply, installation and testing pumping sets, centrifugal, electric driven, dewatering pump of head range 12-18m, discharge 410-210L, capacity of motor 2HP inclusive PCC foundation complete all as specified and directed. |
| 105 | Fabrication, supply, installation, testing and commissioning electrical cubical control panel board an ISO 9001 factory assembled made In door type feeder pillar box weather and vermin proof fabricated of 2.0 mm CRCA MS sheet of suitable size, 3 phase 4 wire 415 Volt ac 50 Hz complete duly painted with powder coating complete with locking arrangement, earthing terminals with suitable rating aluminium strips for incoming/outgoing MCCB's including mounting measuring instrument such as Volt meter, Ammeter -01 No, Selector switchs, CT's -03 Sets, Phase indicator lamps, including incoming and outgoing cables connections with suitable cable glands, lugs including grouting of feeder pillar box complete all as specified and directed. (Feeder piller box shall be consisting the following)(INCOMING) (a) MCCB FP 63 amps, 25 KA , 415 volts, 50Hz = 01 No (OUT GOING) (a) DOL starter suitable for 2 HP pump set = 02 Nos (b) Isolator /MCB TPN 32 amp = 02 Nos (c) Digital Panel mounted Amp meter 96 mm square type complete with selector switch complete with suitable size of CT's - 01 Set(d) Digital Panel mounted Volt meter 96 mm square type complete with selector switch - 01 No (e) RYB indicating lamp, LED type 01 set.(f) PCC (1:2:4) type B1, using 20 mm graded crushed stone aggregate. |
| 106 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 2.5 sq mm, 4 core, 1100 Volts grade complete all as specified and directed. |
| 107 | M&L for construction of measonary valve pit chamber with burnt brick (Sub class \\"B\\") in cement mortor (1:6) and 10 mm thick plastering in CM 1:4 and PCC (1:4:8) type D-2 in foundation bed of size internally 600 x 600 x 600 mm size with 3 mm thick MS sheet cover with locking arrangement hinged with 40 x 40 x 5 mm angle iron frame embeded in PCC (1:3:6) type C-1 etc including painting with two coats of synthetic enamel paint over a coat of red oxide primer to all steel surfaces including earth work complete all as specified and directed. |
| 108 | Supply and fix refrigerator, electric driven (single phase), capacity 185 Litres.BEE 5 star rated complete all as specified and directed. |
| 109 | Supply and fix refrigerator, electric driven (single phase), double door capacity 288 Litres.BEE 2 star rated complete all as specified and directed. |
| 110 | Supply and fix refrigerator, electric driven (single phase), double door capacity 322 Litres.BEE 2 star rated complete all as specified and directed. |
| 111 | Supply and fix refrigerator, electric driven (single phase), double door capacity 400 Litres.BEE 3 star rated complete all as specified and directed. |
| 112 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 0 .5 KVA complete all as specified and directed. |
| 113 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.00 KVA complete all as specified and directed. |
| 114 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.00 KVA complete all as specified and directed. |
| 115 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.00 KVA complete all as specified and directed. |
| 116 | S&F electric water heater,storage type steel body with Glassline / Vitreous Enamel coated heavy-gauge steel inner tank or Copper inner tank and heating element upto 2 KW capacity 15 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc.Supply and fix electric water heater,storage type steel body with copper inner tank and heating element upto 2 KW capacity 15 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece complete all as specified and directed. |
| 117 | Supply, install, test and commissioning commercial type wall mounted electric chimney made out of 16 SWG (304) stainless steel with front turned down, angular frame work fully welded suitable for two Burner Indian Cooking Range 48\\" x 24\\" x 34\\" & three Burner Indian Cooking Range 66\\" x 24\\" x 34\\" including with the following items :-(i) Low height stock pot 24\\" x 24\\" x 24\\" with Stainless Steel Hood (30\\" x 30\\" x 22\\")(ii) Stainless Steel Hood 48\\" x 30\\" x 22\\"(iii) Stainless Steel Hood 66\\" x 30\\" x 22\\"(iv) Three Nos 18 Inches Heavy Duty Exhaust Fans of approved Make in MES above Stainless Steel Hood(vi) Electrical works such as point wiring with suitable size of wire, switch, socket outlet, ceiling rose, MCB DB etc of approved make in MES to be considered(vii) Transportation(viii) Stainless steel exhaust pipe covering |
| 118 | Supply, install, test and commissioning commercial type wall mounted electric chimney made out of 16 SWG (304) stainless steel with front turned down, angular frame work fully welded suitable for two Burner Indian Cooking Range 48\\" x 24\\" x 34\\" including with the following items :-(i) Stainless Steel Hood 48\\" x 30\\" x 22\\"(ii) One No 18 Inches Heavy Duty Exhaust Fans of approved Make in MES above Stainless Steel Hood.(vi) Electrical works such as point wiring with suitable size of wire, switch, socket outlet, ceiling rose, MCB DB etc of approved make in MES to be considered(vii) Transportation(viii) Stainless steel exhaust pipe covering |
| 119 | Supply and and fixing stainless steel electric kitchen chimney 90 cm with 1500 cum/hr suction intelligent auto clean wall mounted, curved glass, baffle filter, motion sensor control, oil collector tray with inbuilt LED light including aluminium flexible pipe of 150 mm dia of suitable length with suction cover, with all accessories including making/ cutting hole of 150mm dia suitable for aluminium exhaust pipe and making good complete all as specified and directed. (For Officers & JCO Mess) |
| 120 | Supply, Installation, testing and commissioning complete of manufacturer or OEM manufactured, static silent (Sound Proof enclosure) Diesel Engine Driven Generating Set capable of delivering 50 KW (62.5 KVA), 415 Volts (AC three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangement, exhaust pipe complete and suitable for conditions prevalent at Dibrugarh (Capacity of Engine, alternators shall be worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5 M all around for ease of movement and 0.5 M height), anti-vibration pads, including all features to comply with latest CPCB-IV guidelines and Comprising of followings:- |
| 121 | Serial item No. 3.63 continued....(i) ENGINE (Prime Mover): Diesel Engine 1500 RPM , direct injection, 4 cylinders, four stroke, radiator cooled, performance class of generator set ISO 8528-5 G2, turbo charged, capable of giving adequate BHP to drive Alternator capable of delivering 50 KW (62.5 KVA) at outdoor atmospheric conditions at Dinjan, (Taking all derating factor into consideration), 12/24 Volt (as per manufacturer recommendations) electric battery start incl suitable size battery, complete withy fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc .(ii) Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 50 KW(62.5 KVA), Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class \\"H\\", salient pole, revolving field, sealed bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine :- (iii) BASE PLATE: made out of structural steel as per manufacturers recommended design/specifications.(iv) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition .(v) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 0.5 m Space should be available all around the Set and height of plinth shall not be less than 0.5 M(vi) Diesel storage tank of capacity adequate for storage of diesel as per manufacturer specification. |
| 122 | Serial item No. 3.63 continued....(vii) AMF Panel: -Microprocessor / Relay based pedestal mounted indoor use AMF control panel of suitable rating made up of 3 mm thick CRCA Sheet steel enclosure duly painted with power coated double contactor type for mains and alternator with necessary aluminum bas bar for 3 phase, 4 wire system incl necessary relays, timer, fuses, interconnection copper cabling work incl fixing on floors by grouting, PCC work complete.(a) MCCB of suitable rating with short circuit protections-1 No (b) Digital multifunction meter of size 96x96 mm to measure current, voltage, KW, frequency and power factor with built in selector switch and programmable CT ratio with RS 485 port(c) Phase indicating lamps(R-Y-B) -1 set(d) All standard relays, circuits and protection required for automatic operation of Gen set(e) Data logging : Engine hours, Control hours and upto 5 recent fault codes(f) AC Alternator Protection : Over/under Voltage, Over/under frequency, Loss of AC sensing, Over speed, Over Current, KW Overload(viii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.(ix) First fill of Lubricants, Coolant & Fuel: -First fill of oil, coolant as per OEM recommendations and diesel during testing for 12 hrs as per CA provn.Note: PCC foundation for DG Set shall be deemed to be included in the rate quoted for all DG sets: - (a) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Department(b) The contractor shall arrange for artificial load (water load/Electrical load) for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (c) Testing of sound level should carried out at the site in presence of Engineer-in-Charge(d) One set of latest Spare part catalogue with price, exploded view of parts and user's manual are deemed to be included in the offer. (e) All civil works including foundation for DG Set as per manufacturer's drawing/ specification, foundation for AMF panel. (f) The rate quoted is deemed to be included for initial filling of radiator coolant and lubricating oil upto level |
| 123 | Supply and Installation and ommissioning of ongrid solar photovoltaic roof top power plant of capacity 160 KwP conforming to MNRE specifications as ammended consisting of Mono/ poly crystalline silicon solar cells , net metering facility, necessary protections, earthing, mounted on Aluminium/ GI structures of suitable strength with the following units :(a) Solar photovoltaic Module of Capacity 330 Wp, Must having manufactured in INDIA, output shall not be less than 90% at the end of 10 years and 80% at the end of 25 years.(b) Power Conditioning unit (PCU) 350 -800 V DC input Voltage range and 400 Volt AC, three phase 4 wire, 50 Hz with efficiency not less than 97%, total harmonic distortion less than 3%, OperatingTemp range from 0 to 58 degree.(c) Data monitoring system (d) Lightning protection and surge voltage protection ( power control cable and arrarys as required.(e) Suitable Aluminium/ GI structures for holding Plates.(f) Power and control cables required for the plant shall be included (g) Other accessories complete to run the plant smoothly also deems to be included. (Considered for SM Barrack Area = 2764 sqmt x 60% for Solar Panel = 1658.40 sqmt Say 1600 SQM) |
| 124 | Bringing approved earth (As approved by GE) from sources outside defence land including all costs such as royalty if any, transportation, taxes etc for area filling / forming including rising earth spreading in layers not exceeding 30 cm thick each layer watering and compaction with 8 tonne to 12 tonne power roller and finished to required size and shape etc up to any high / depth from existing ground level complete all as specified and directed.Note:(i) Earth required for this item shall be supplied by the contractor from outdide of the MOD land of any lead at his own cost and arrangement.(ii) All cost of procurement of earth including cost of transportation , royalties and tax shall deemed to be included in the quoted rate for this item.(iii) With reference to the clause 3.6 of SSR part II on serial page No. 21, it is clarified that measurement of this item shall be finished embankment / traverse of filled earth after consolidation / compaction and 5% deduction shall be made from measured and calculated volume to allow for increase in bulk.(iv) The total quantity or partial quantity of earth may not be available in Dibrugarh area. The contractor shall bring the earth from outside the Dibrugarh area. Therefore it is advised to contractor to check the availability of earth and its lead involved before quoting his rate against this item. |
| 125 | M&L for shallow sewers of 300 mm dia RCC NP3 pipes laid on 150 mm thick PCC (1:4:8) bed with excavation up to required depth to achieve self cleaning velocity in any type of soil including manholes of standard size made of brick massonry with SFRC ventilating cover and frame, other activities to execute the work and make sewer line functional complete all as specified and directed. |
| 126 | S&F Modular type 3 pin 20 A Socket with SP MCB 1 No, conforming to IS 1293 : 2005 as specified in IS 732 : 2019 complete all as specified and directed. (for AC & Geyser Point) |
| 127 | S&F Decorative LED type wall mounted light fitting sutable for LED lamp 9-20 W , housing- glass, frosted type, metallic frame and including one LED lamp 12 watt complete all as specified and directed. |
| 128 | Supply, Installation, testing & commissioning of LED Engagement light fitting (Red & Green), 220 V, luminaire made of CRCA housing and PC diffuser (Diffuser-Non yellowing type). The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed system lumens at a system efficacy of at-least 100 lumen/watt. Power consumption should not be more than 10W (± 5%). The Life of fixture (Including Driver):50000 burning Hrs. @ L70B50 Lumen maintenance @ design ambient temp 45 deg C. The electronic driver used shall have a power factor 0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, Current Ripple ≤ 5%, Internal surge protection should be minimum 2 KV, electrical insulation class should be Class I & driver should be of Class B serviceability. The luminaire shall be IP20 & IK02 compliant. The luminaire driver shall be of the same make / manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322 & \\"FAT\\" before dispatch as per IS 10322. The Contractor must submit the NABL accreditation certificate for Luminaire manufacturer along with Sample Approval. The LED Luminaire & it's driver both should be BIS registered. Contractor shall submit the following reports before supply of material for approvals LM79 issued by NABL accrediated lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accrediate lab, RoHS compliance issued by LED luminaire manufacturer, BIS certificate for LED Luminaire & Driver complete all as specified and directed. |
| 129 | S&F MCB DB 6 Way, VTPN, modular type, double door, metallic dstribution board conforming to IEC 61439:3, suitable for flush / surface mounting with provision for MCCB as incomer and SP / DP / TP MCB as outgoing, reversible metal door, 100 A copper busbar, fully shoruded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection as specified in IS 732 : 2019 complete all as specified and directed |
| 130 | S&F MCB DB 4 Way, VTPN, modular type, double door, metallic dstribution board conforming to IEC 61439:3, suitable for flush / surface mounting with provision for MCCB as incomer and SP / DP / TP MCB as outgoing, reversible metal door, 100 A copper busbar, fully shoruded neutral bar, earth bar, wire set & cable ties for cable management, pre fitted masking sheet, etc. having IK 09 & IP 43 protection as specified in IS 732 : 2019 complete all as specified and directed |
| 131 | S&F Surge Protection Device (SPD) single phase and neutral, T2 -limb, Imax 20 KA per pole fixed in distribution board and making connections complete all as specified and directed |
| 132 | S&F Surge Protection Device (SPD) Three phase and neutral, T2 -limb, Imax 20 KA per pole fixed in distribution board and making connections complete all as specified and directed |
| 133 | S&F Modular Telephone socket RJ 11 suitable for housing modular frame plate complete all as specified and directed |
| 134 | S&F modular type TV socket. RJ46, 1 module complete all as specified and directed. |
| 135 | Supply, install, test and commission of LT Panel No 1, TPN 415 Volts, 50 Hz, indoor cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 2.0 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley aluminium bus bar suitable for carrying of current 600 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB's (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following (for Single Living Accn for Rif Coy) :- (a) MCCB 4 pole, 415 V, Microprocessor based, Adjustable range 0.7 to 1 In, 400 Amp with breaking capacity 25 KA - 1Nos (Incoming).(b) MCCB 160 Amps, 4 Pole, 50 Hz, 415 V with thermal magnectic release having rupturing capacity 25 KA - 4 Nos (01 No Spare).(c) Single Phase timer Switch - 01 No(d) 3Ph digital multi function meter model A, class 1, 5A with relay Vega Series - 1No(e) Indicating lamp 240 volts LED type - set of three. |
| 136 | Supply, install, test and commission of LT Panel No 2, TPN 415 Volts, 50 Hz, indoor cubical type floor mounted CPRI approved factory made, double door dust and vermin proof IP-54, fabricated out of CRCA sheet not less than 2.0 mm thick with 2mm thick for internal compartment duly powder coated fixed on angle iron pedestal made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of LED indicator lamp RYB with switch and fuse and the panel board shall be provided with proper ventillation including suitable size of cable alley aluminium bus bar suitable for carrying of current 600 Amps with suitable connections from MCCB out going to main bus bar shall be carried out with TPN aluminium bus bars of suitable rating and connections from main bus bar to out going MCCB's (intake point) will be carried out with TPN aluminium bus bar as per MCCB rating duly insulated and colour coded heat shrinkable sleeve and shall be rigidly mounted on suitable size of bridge insulator including necessary PCC foundation of minimum 0.35 m height positioned and fixed with suitable nut, bolts, washers etc to the MC pedestal all as specified and directed comprising of the following (for Office & Admin Bldg) :- (a) MCCB 4 pole, 415 V, Microprocessor based, Adjustable range 0.7 to 1 In, 400 Amp with breaking capacity 25 KA - 1No (Incoming).(b) MCCB 160 Amps, 4 Pole, 50 Hz, 415 V with thermal magnectic release having rupturing capacity 25 KA - 3 Nos (01 No Spare).(c) Single Phase timer Switch - 01 No(d) 3Ph digital multi function meter model A, class 1, 5A with relay Vega Series - 1No(e) Indicating lamp 240 volts LED type - set of three. |
| 137 | Comprehensive annual maintenance of 160 kWp capacity roof top solar photovolaic (SPV) on grid system icluding operation support, preventive maintenance, servicing, testing, repairs, cleaning, replacement of minor spare parts and ensuring optimum power generation as per OEM's recommendation, MNRE duidelines complete all as specified and directed.1. SCOPE OF WORK1.1 SOLAR PV MODULES MAINTENANCE(i)Cleaning of solar panels periodically to remove dust, bird droppings and debries for maintaining efficiency. (ii) Checking modules for cracks, hotspot, discoloration or physical damage. (iii) Inspection of mounting structure and tightning of fasteners. (iv) Checking module alignment and shading issues.1.2 INVERTER MAINTENANCE(i) Inspection and servicing of grid tie inverter.. (ii) Checking inverter parameters, fault logs and alarms. (iii) Cleaning of inverter ventilation system and cooling fans. (iv) Firmware/settings verification as per OEM.1.3 ELECTRICAL MAINTENANCE(i) Inspection of DC cables, connectors (MC4) and combiner boxes. (ii) Checking ACDB/DCDB panels including isolators, MCCB, SPD and earthinf system. (iii) Tightening of terminals and thermographic inspection (if applicable). (iv) Testing insulation resistance and continuty.1.4 MONITORING AND PERFORMANCE CHECK(i) Monitoring dailt energy generation and system performance ratio. (ii) Recording generation data and maintaining logbooks. (iii) Checking net meter synchronisation with grid supply.1.5 SAFETY AND PROTECTION(i) Inspection of lightning protection system and earthing.(ii) Checking surge protection devices (SPD). (iii) Ensuring safety signage and compliance.1.6 PREVENTIVE MAINTENANCE SCHEDULE(i) Daily/ weekly visual inspection. (ii) Periodic cleaning of solar modules. (iii) Monthly inspection of inverter and electrical panels. (iv) Quarterly testing and performance veriication. |
| 138 | Serial item No. 4.00 continued....1.7 CONSUMABLES AND MINOR SPARES(i) Cleaning materials, fasteners, cable ties, lugs and lubricants. (ii) Replacement of minor electrical components as required.1.8 COMPLIANCE(i) As per MNRE guidelines, CEA regulations and local DISCO norms. (ii) Ensuring maximum generation efficiency and safe operation.NOTE: Payments shall be made on monthly / quarterly / half yearly / yearly basis in equal installments of amount due for that year on submission of RAR by the contractor to GE. |
| 139 | (a) Comprehensive annual maintenance of 160 kWp roof top solar for 1st year after completion of Phase I complete all as specified and directed. |
| 140 | (b) Comprehensive annual maintenance of 160 kWp roof top solar for 2nd year after completion of Phase I complete all as specified and directed. |
| 141 | (c) Comprehensive annual maintenance of 160 kWp roof top solar for 3rd year after completion of Phase I complete all as specified and directed. |
| 142 | (d) Comprehensive annual maintenance of 160 kWp roof top solar for 4th year after completion of Phase I complete all as specified and directed. |
| 143 | (e) Comprehensive annual maintenance of 160 kWp roof top solar for 5th year after completion of Phase I complete all as specified and directed. |
| 144 | Comprehensive annual maintenance of 50 KLD capacity sewage treatment plant including operation, preventive maintenance, servicing, repairs, replacement of minor spare parts, consumable and ensuring efficient functioning of the plant as per OEM's recommendation complete all as specified and directed.1. SCOPE OF WORK1.1 OPERATION & MONITORING(i) Operation of STP to achieve designed treatment efficiency. (ii) Monitoring of treatment parameters such as pH, BOD, COD, TSS, DO levels. (iii) Maintenance of daily log sheets and operational records.1.2 MECHANICAL MAINTENANCE(i) Servicing and maintenance of pumps, blowers, aerators, aligators, defusers, valves and pipe lines. (ii) Alignent, lubrication, greasing and replacement of worn out parts. (iii) Checking sludge handling and transfer system.1.3 ELECTRICAL MAINTENANCE(i) Maintenance of control panels, starters, MCC panels, cables, sensors, level contrillers and electrical accessories. (ii) Testing and checking of motors protections, earthing and safety devices. (iii) Tightening of connections and preventive inspection.1.4 CIVIL MAINTENANCE(i) Cleaning of tanks, chambers and inlet / outlet structures. (ii) Checking for leakage , cracks and minor civil repairs.1.5 CONSUMABLES & CHEMICALS(i) Supply and use of necessary lubricants grease, minor consumables and chemicals required for smooth operation.1.6 SLUDGE HANDLING AND DISPOSAL(i) Periodic removal of sludge and proper disposal as per environmental norms and as per direction of Engineer in Charge.1.7 COMPLIANCE(i) Maintaining treated water quality as per PCB norms. (ii) Following safety standards and use of PPE during maintance.NOTE: Payments shall be made on monthly / quarterly / half yearly / yearly basis in equal installments of amount due for that year on submission of RAR by the contractor to GE. |
| 145 | (a) Comprehensive annual maintenance of 50 LKD sewage treatment plant for 1st year after completion of Phase I complete all as specified and directed. |
| 146 | (b) Comprehensive annual maintenance of 50 LKD sewage treatment plant for 2nd year after completion of Phase I complete all as specified and directed. |
| 147 | (c) Comprehensive annual maintenance of 50 LKD sewage treatment plant for 3rd year after completion of Phase I complete all as specified and directed. |
| 148 | (d) Comprehensive annual maintenance of 50 LKD sewage treatment plant for 4th year after completion of Phase I complete all as specified and directed. |
| 149 | (e) Comprehensive annual maintenance of 50 LKD sewage treatment plant for 5th year after completion of Phase I complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedOct 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysOct 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender