Tender For Electrical Renovation Works To Setting Up New Court With Chambers, Bathroom At Various Premises Under Judges Court, Kolkata-27

Issued by Government Departments · Kolkata, West Bengal
Tender Value
8.64 Lakhs
Estimated cost
Bid Submission
21 Sep 2026
6 days left
EMD
17284
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Electrical Renovation Works To Setting Up New Court With Chambers, Bathroom At Various Premises Under Judges Court, Kolkata-27

BOQ

Name of Work:- Electrical renovation works to setting up new court with chambers, bathroom at various premises under Judges Court, Kolkata-27
Sl. No. Item Description
1Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
2a) 8 way (4 + 24), Double door [DSR (E&M)-2025, P-14/2.5.2] [Make :-Legrand/Siemens/L&T or as approved by EIC]
3Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). [DSR (E&M) 2025,P-14/2.4] Make list as per CPWD General Specification for electrical works
46 way (4 + 18), Double door [DSR (E&M) 2025,P-14/2.4.2] [Make :-Legrand/Siemens/L&T or as approved by EIC]
5Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) [DSR (E&M) 2025,P-14/2.3] Make list as per CPWD General Specification for electrical works
612 way , Double door [DSR (E&M) 2025,P-14/2.3.3] [Make :-Legrand/Siemens/L&T or as approved by EIC]
7Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
8(b) 40 A [DSR (E&M)-2025, P-15/2.12.1] [Make :-Legrand/Siemens/L&T or as approved by EIC]
9Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
1063A [DSR (E&M)-2025, P-15/2.13.2] [Make :-Legrand/Siemens/L&T or as approved by EIC]
11Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required.
12125 A,36KA,FPMCCB [DSR (E&M)-2025, P-13/2.2.14] [Make :-Legrand/Siemens/L&T or as approved by EIC]
13Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
14Single pole [DSR (E&M)-2025, P-15/2.10.1] [Make :-Legrand/Siemens/L&T or as approved by EIC]
1563 Amps TP MCB [ 7 / D- 6] [Make :-Legrand/Siemens/L&T or as approved by EIC]
16Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable [Make: Gloster/Polycab/Havells/RR Kable or as approved by E.I.C] in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box (Legrand Myrius/Arterior or equivalent Model of Roma Urban or as approved by EIC) and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
17Group B [DSR (E&M)-2025, P-3/1.10.2]
18Wiring for circuit/ submain wiring along with earth wirewith the following sizes of FRLS/HFFR PVC insulatedcopper conductor, single core cable [Make: Gloster/Polycab/Havells/RR Kable or as approved by E.I.C] in surface/ recessed medium class PVC conduit as required.
194 X 16 sq. mm + 2 X 6 sq. mm earth wire [DSR (E&M)-2025, P-4/1.14.11 ]
20Supplying and fixing of following sizes of mediumclass PVC conduit (Make:-Precision or as approved by EIC) along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
2120 mm size [ DSR (E&M)-2025, P-6/ 1.21.1 ]
22Supplying and drawing following sizes of FRLS/HFFRPVC insulated copper conductor, single core cable [Make: Gloster/Polycab/Havells/RR Kable or as approved by E.I.C] in the existing surface/ recessed steel/ PVC conduit asrequired.
23i) 3 x 1.5 sq. mm [DSR (E&M)-2025, P-4/1.17.3]
24ii)3 x 2.5 sq. mm [DSR (E&M)-2025, P-4/1.17.12]
25iii)3 x 4 sq. mm [DSR (E&M)-2025, P-4/1.17.21]
26iv)3 x 6 sq. mm [DSR (E&M)-2025, P-4/1.17.30]
27Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
28a)1.5 sq mm
29b) 2.5 sq mm [9(i) / F-5]
30c) 4 sq mm [9(ii) / F-5]
31d) 6 sq mm [9(iii) / F-5]
32f) 16 sq mm [9(v) / F-5]
33Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Legrand Myrius/Arterior or equivalent Model of Roma Urban or as approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.. [12 /E-18 ]
34Supplying & fixing suitable size GI box with modular plate and cover (Legrand Myrius/Arterior or equivalent Model of Roma Urban or as approved by EIC) in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required [DSR (E&M)-2025, P-11/1.57]
35Supply & Fixing 240 V,25 A, 3 pin Modular type plug topwith indicator (L&T/Anchor or as approved by EIC) & necy. Connections [5(b)/E-17]
36Supplying and fixing suitable size GI box with modular plate and cover (Legrand Myrius/Arterior or equivalent Model of Roma Urban or as approved by EIC) in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.[DSR (E&M)-2025, P-8 / 1.32 ]
37Supplying and fixing suitable size GI box with modularplate and cover (Legrand Myrius/Arterior or equivalent Model of Roma Urban or as approved by EIC) in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modularswitch, connections etc. as required. (For light plugsto be used in non residential buildings). [DSR (E&M)-2025, P-11 / 1.56 ]
38Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)[ 29)/D-14 ]
39Supplying & Fixing iron beam fan clamp of two piece type, as per approved specification, fabricated from 40 mm x 9 mm MS sheet flat suitable for beam having flange upto 150 mm wide – (As per Drawing no. 476 of PWD Specification Book – May 1991)[ 30/D-14 ]
40Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required..[DSR (E&M)-2025, P-7 / 1.25 ]
41Supply and fixing 415 V TPN SFU with sheet steel enclosure with nuts bolts with S&F 3 Din-Type HRC fuse on angle iron frame on wall as per rating including power coated painting on it (Siemens/ L &T or as approved by EIC) of different sizes [ 4(a)/D-3 ]
42a) 125A
43Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. [DSR (E&M)-2025, P-32/5.18]
44Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. (a) Above 35 sq. mm and upto 95 sq. mm (clamped with25x3mm MS flat clamp) [DSR (E&M)-2025, P-66/10.7.2 ]
45Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
464 X 50 sq. mm (35mm) [DSR (E&M)-2025, P-69/11.1.35]
47Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. (IS 7098 Part - 1/2011 with Up To Date Amendments.) [Make: Gloster/Polycab/Havells/RR Kable or as approved by E.I.C]
484 core 50 sqmm
49Supply & fixing automatic single phase AC starter of 21Amp capacity equipped with Timecheck, Voltcheck & Ampcheck and 3-digit display (Make- Electron-model no.-OPL-3+ or equivalent model of LT/Legrand or as approved by E.I.C) to be fixed on 4Module GI box with all fixing accessories complete as to G.S.
50S & F timer control unit for 1ph ac machines(make L& T/legrand/siemens/ABB) in existing DBs
5112 way SPN DB or Timer DB---1 no.
5240 A DP isolator---1 no.
53Digital 24 hrs time switch---1 no.
5432A 2pole power contactor---1 no.
55centre off 2way toggle switch---1 no.
5632 A barrier type terminal---1 no.
57LED indicating lamp---2 nos.
582x4+1x2.5 sqmm Cu wire [Make: Gloster/Polycab/Havells/RR Kable or as approved by E.I.C] Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57341164
AUTHORITY Government Departments
TENDER VALUE 8.64 Lakhs
LAST DATE 21-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Electrical Renovation Works To Setting Up New Court With Chambers, Bathroom At Various Premises Under Judges Court, Kolkata-27
Basic Detail
Tender No WBPWD/EE-ECD/e-NIT-57/2026-27
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 03 Sep 2026
Submission Date 21 Sep 2026
Open Date 23 Sep 2026
Finance
Tender Value 8.64 Lakhs
Tender Fee Ref. Documents
EMD 17284
Exemption Not Available
Document List
BOQ_5102445.xls
d8946642-7744-4ef2-9842-0d3cf911eac1.html
Tendernotice_1 (37).pdf
Tendernotice_2 (4).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_5102445.xls

html

d8946642-7744-4ef2-9842-0d3cf911eac1.html

pdf

Tendernotice_1 (37).pdf

pdf

Tendernotice_2 (4).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders