Tender For Providing Of Certain Minor Works Under Ge (West) Agra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
24 Sep 2026
11 days left
EMD
25752
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Agra → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Providing Of Certain Minor Works Under Ge (West) Agra
BOQ
| Sl. No. | Item Description |
| 1 | Supply and fix electric water heater, storage type steel body with fiber glass coated inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. including fastener mild steel 100 mm long x 10 mm dia with pin and bolts complete for hanging of geyser all as specified and directed |
| 2 | Supply & fix in replacement, single pole and neutral Modular type (AC box) with one no. MCB SP of capacity 20 Amps 240 volts 10 KA IK-08 As per IEC 61439-3 complete all as specified & directed. |
| 3 | M&L for concealed point wiring for one light point/fan point/bell point controlled by one switch (using red, black and green colour coding) complete with 4.0 sqmm unsheathed and multi stranded copper conductor single core FRLSH PVC insulated, 1100 volts PVC insulated unsheathed cable with proper colour coding drawn in through and including PVC concealed conduit not less than 20 mm dia ( medium duty, ISI marked) with all fittings and accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc.,including pressed steel powder coated sunken terminal box suitable for modular switch socket including provn of 4.0 sqmm single core FRLSH PVC insulated multi standed copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ ceiling/ floors etc by using CM (1:3) complete all as specified and as directed. NOTE:- MCB Box shall be measured and paid separately under appropriate item. |
| 4 | M&L for sub main wiring with two runs of single core FRLSH PVC insulated, unsheathed, multistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLSH PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length. |
| 5 | S & F galvanized iron tubes, medium grade of size 15 mm bore fixed to wall, ceiling and laid under floor complete all as specified and directed. |
| 6 | S&F 15mm dia stop cock, cast copper alloy, out side thread, high pressure with fancy type chromium plated screwed both ends for iron pipe complete all as specified & directed. |
| 7 | S&F Brass CP wall mixer for mixing hot & cold water iron pipe of size 15 mm bore and fixed cast copper alloy with crutch , screwed down, screwed for complete all as specified & directed. |
| 8 | S&F PVC connection 15mm bore, 450mm long in any position with both end brass nut with inner threading and washer suitable for cold and hot water connection complete all as specified & directed. |
| 9 | Supply & fix MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. |
| 10 | Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated single door SPN 4 way with 200 amps rated bus bar 240 volts complete all as specified and directed. |
| 11 | Supply & fix MCB SPN, 40 Amps, 'C' series, 240 volts, 50Hz, 10kA complete all as specified & directed. |
| 12 | S&F anodised/powder coated aluminum alloy interlocking snap grid 600mm x 600mm consists of Min Tee runners of size 38mm x 25mm x 1.5mm and cross Tee of size 25mm x 25mm x 1.5mm, spaced between the main Tee at 600mm centre to centre to form a grid of 600mm x 600mm and wall angle 25mm x 25mm x 2mm fixed to wall perimetrs at 450mm centres and shall confirm to IS 733, IS 1285 with and including hangers of 6 mm dia. G.I. (upto 1200mm length and 1200mm centres) adjusting level fixed to roof steel members by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long etc complete all as specified and directed. |
| 13 | M & L for 4mm thick non asbestos fibre cement building boards designer type fixed or laid/ inserted to timber/GI/Aluminium framework with screws fixed in ceiling flat or sloping complete all as specified and direced. |
| 14 | M&L for lead lined door 46-60mm th (double leaf)(size upto 2.5 Sqm) Jams of allaround lead sheet adiation resistant reqd steel frame (2mm thick lead sheet 99% purity)SS hinge 150mm size , 4 Nos each leaf of door 2 leaf needed to smooth and controlled closer upto 80kg capacity mortice lock with half cylinder and lever handle provided proper security , 2 nos of lead vision glass size 350mmX 350mm in each leaf with laed coating frame the door should be designed to meet specific radiation protection as per AERB inner sheet should be polyurethane puff (density 40 Kg/ Cum) 4 Nos of SS hermed handle on both side of door blade of smooth and easy opening &closing all as specified incl removal of existing door with frame.(note: Door should be installed after approval of GE) |
| 15 | S&F 5.00 mm thick sheet glass, ordinary quality and fixed with aluminum beading and gaskit suitable for aluminum frames in squares not exceeding 0.5 sqm in each pane complete all as specified and directed. |
| 16 | S&F solid PVC sheet of density 600 kg/m3 as in wall lining consisting of 5mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing |
| 17 | S&F 5mm thick PVC sheet of density 600kg/m3 in fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing. |
| 18 | Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality of capacity 1.5 ton with 5 star rating, connecting copper pipe upto 3 mtr, complete all as specified and directed. |
| 19 | Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA. |
| 20 | Supply & fixing heavy duty copper pipe 6 mm (1/4\\") dia/ bore complete including insulation brazing, welding, nuts, bolts and screws of required size including taking down old unserviceable one complete all as specified and directed. |
| 21 | S&F 300mm sweep wall mounted fan with power comsumption of 90W, 3 speed settings, air delievery of 100m3/min, complete all as specified and directed. |
| 22 | Supply, installation, testing and commissioning of wall-mounted, powder-coated CRCA sheet steel metal enclosure Distribution Board (DB), suitable for indoor use, complete with 32A rating incomer and outgoing arrangement, having 3 Phase + Earth + Full Phase Barrier + Neutral (3P+E+FP+N) configuration. The enclosure shall be dust and vermin proof, fabricated from minimum 1.6 mm thick sheet steel, with hinged lockable door, detachable gland plates, neutral link, earth bar, busbars of adequate current carrying capacity, interconnections, mounting accessories, identification labels, and all necessary hardware, complete all as specified and directed. |
| 23 | M&L for concealed point wiring for socket outlet of 15/16A controlled by one switch (using red, black and green colour coding) complete with 2.5 sqmm unsheathed and multi stranded copper conductor single core FRLSH PVC insulated, 1100 volts PVC insulated unsheathed cable with proper colour coding drawn in through and including PVC concealed conduit not less than 20 mm dia ( medium duty, ISI marked) with all fittings and accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc.,including pressed steel powder coated sunken terminal box suitable for modular switch socket concealed in wall, suitable for fixing modular switches/ socket/ regulator etc, including provn of 2.5 sqmm single core FRLSH PVC insulated multi standed copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ ceiling/ floors etc by using CM (1:3) complete all as specified and as directed. NOTE:- Modular switches/ socket/ regulator shall be measured and paid separately under appropriate item of AE Part-II. |
| 24 | All as per item No-23 above but using 4.0 sqmm PVC FRLSH insulated stranded copper conductor cable and for one socket outlet controlled by one way switch on an independent board complete all as specified and directed. |
| 25 | All as per item No-23 above but using 1.5 sqmm PVC FRLSH insulated stranded copper conductor cable and for one socket outlet controlled by one way switch on an independent board complete all as specified and directed. |
| 26 | Supply and fixing modular switch 16 Amps single pole one way, one module, complete all as specified and directed. |
| 27 | Supply and fixing modular socket multipurpose 3/5 pin 6/16 Amps combined 2 module, complete all as specified and directed. |
| 28 | Supply and fixing modular switch single pole, one way 6 Amps 1 module, complete all as specified and directed. |
| 29 | Supply and fixing modular cover plate with metal frame (inner and outer) 3 module for mounting switch and sockets all as specified and as directed. |
| 30 | Supply and fixing modular cover plate with metal frame (inner and outer) 2 module for mounting switch and sockets all as specified and as directed. |
| 31 | Supply and fixing LED luminaire fully diffused, 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light, extruded aluminium housing 11.5mm depth only,edge lit LED panel with light output of 3000 lumen, 25000 hrs life class, 4000k Neutral white light, complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete as specified and directed. |
| 32 | Supply and fix in replacement MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 100 amps rated copper bus bar 240 volts IP-43, IK-09 with metal doors complete all as specified and directed. |
| 33 | M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanized steel earth lead wire of 4 mm dia, including 15 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Loose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 . |
| 34 | M&L for brick work with sub class ‘B’ bricks old size, straight or curved on plan exc 6 M mean radius, built in CM 1:6 including demolitio of brick work built in CM complete all as specified & directed |
| 35 | M&L for Providing and Repairing the damaged concrete portion / Surface preparation with single component ready to use, repair mortar capable of applying10-12 mm avg. thick in single layer initially by hand and finishing with trowel, carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface complete all as specified and directed |
| 36 | M&L for 10-12mm thick ready mix repair plaster with high quality polymer additives and well graded sand and fillers which can be used for plastering (as per manufacturer instructions )over interior surface of wall complete all as specified and directed. |
| 37 | Preparing newly plastered surfaces of walls and applying two coats of oil bound distemper over and including two or more coat wall care putty on wall complete all as specified and directed. |
| 38 | Material & Labour for preparing newly plastered surfaces of wall, applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm including putty over new surface of wall complete all as specified and directed. |
| 39 | Dismantling of Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete , including taking out, cleaning of flase ceiling and handling removing to store or stacking for reuse all as specified and directed. |
| 40 | S&F anodised aluminium/GI snap grid frame work for false ceiling all as specified of grid 605 x 605 including GI hangers of suitable dia and fixed to purlin/rafters as specified. |
| 41 | S&F 4 mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws complete all as specified and directed. |
| 42 | M&L for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet of density 600kg/m3 inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed. |
| 43 | S&F 5mm thick PVC sheet of density 600kg/m3 fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed. |
| 44 | M&L 25 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in sub base of flooring finished even and fair without using extra cement complete all as specified & directed. |
| 45 | M & L for Vitrified tiles 10mm thick light shade (square/rectangular) area of each tile exceeding 0.42 sqm but n exc 1.00sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match in floor over and including 15mm thick cement screed bed of CM (1:6) complete all as specified & directed. MAKE: Johnson/Kajaria/Somany . |
| 46 | Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings, kerbs, benching and the like, including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete. |
| 47 | Taking down Chowkhats orframes exc. 1.5 sq. m but n. exe 4 sqm (without taking off shutters from the frames each complete all as specified and directed. |
| 48 | S&F powder coated anodized aluminium door & frame with reqd size of aluminium sections weighing 0.55 kg/mincluding 5 mm thick tinted glass coloured in half portion and in other half portion 4 mm thick ACP sheet of any colour complete and fixed with anodized aluminium snap beading, glazing clips, joining clips, screws and 02 Nos of aluminium handle on each door shutter, aluminium anodized tower bolt 200mm long 02 Nos on each shutter and mortice lock device complete with double keys for each lock, 01 No Hydraulic door closer for each shutter complete all as specified and directed with following specifications:- (a) Aluminium door frame = 101.50x44.45mm (b) Aluminium style/top & middle rails of shutter = 83.5x44.45mm(c) Aluminium bottom rail of shutter = 114.50x44.45mm(d) Aluminium door frame with shutters shall be fixed in position in brick wall opening as required according to site conditions including all fastening arrangements etc complete all as specified and directed. |
| 49 | Providing and fixing factory made uPVC white colour fixed window (Area exc 1sqm but n exc2 sqm each)made of extruded profiles with wall thickness of 2.3mm(+-0.2mm). Window profile with hollow section with multi chamber. Frame (60mm x58mm). T profile (Onevertical length in between two shutters) (60mm x 74mm). Glazing bead (35mm x20mm) will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc. making arrangement for fixing of hardware, EPDM gasket.1.2 +–0.2mm thick, galvanized steel Frame (28mm x21.5mm), T profile (27mm x 17 mrn) to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners- 5mm thick glazing with selected quality glass including glass complete all as specified and directed. |
| 50 | Demolition of cement concrete (unreinforced) in gd floor and paving n.exc 15 cm thickness below or above the gd level. |
| 51 | M&L hardcore of gauge exc.63 mm but not exc 100 mm deposited , spread and levelled in layers n exc. 15 CM thick, watered and rolled/rammed to a true surface complete all as specified and directed. |
| 52 | M&L Cement concrete 75 mm thick type type typeD-2, 1:4:8 (40mm graded aggregate) Stone Aggregate as in sub base of floor etc complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysSep 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer