BOQ
| Sl. No. | Item Description |
| 1 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises as directed by Engineer-In-Charge. |
| 2 | M&L for 25mm thick cement concrete type B0 1:2:4 using 12.5mm graded stone aggregate as in sub base floors all as specified and directed. |
| 3 | M&L for mat finish coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in CM 1:6 all as specified and directed. |
| 4 | All as per item No 03 above but on vertical surfaces such as in skirting and dados laid over 10 mm thick plaster in CM 1:4 all as specified and directed. |
| 5 | M&L for non skid coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in CM 1:6 all as specified and directed. |
| 6 | M &L for Glazed ceramic coloured tiles in vertical surfaces such as in skirting and dados 350x250x7mm/450x350x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over 10mm thick plaster in CM 1:4 all as specified and directed. |
| 7 | M &L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 8 | Supply and fix in repairs 25 mm bore stainless steel heavy duty drapery rod (curtain rod) including all fittings and fixers , cut to length and fix in position including decorative type FINIALS (bracket) colored finish, of approved pattern complete as per sample. |
| 9 | Removing building materials etc (other than spoil payable under item No 03028 to 03031 in Section 3 earthwork of SSR Part II) to a distance exceeding 1.0 Km but not exceeding 1.5 Km beyond the lead included in the rates, incluing loaing, unloaing and stacking at the destination complete all as specified and as directed by Engineer-in-Charge. Note:- one metric tonne shall mean one load Refer preamble of SSR item No 21055. |
| 10 | Taking down cement plaster on brick or stone walls or PCC block walling, roof including raking out joints hacking for key scrubbing down with water etc. |
| 11 | M&L for 5 mm thick rendering for fair faces of concrete surfaces on ceiling in CM 1:3 for fair finished surfaces. |
| 12 | M&L for rendering 10mm thick on concrete surface of wall in cement mortar 1:6 finished even & smooth without using extra cement. |
| 13 | M&L for rendering 15mm thick in CM 1:4 with water proofing compound @3% by wt of cement on fair faces of brick work or concrete surfaces,, finished even and fair. Note : WPC will be measured and paid separately. |
| 14 | Supply only water proofing compound |
| 15 | M&L for preparing new plastered ceiling/soffits of chajjas surfaces and applying three coats of white wash complete all as specified and directed by Engineer-in-Charge. |
| 16 | M&L for preparing new plastered wall surfaces and applying two coats of distemper with distemper oil emulsion, white or tinted including one coat of 3mm wall care putty by finishing the surfaces even and smooth complete all as specified and directed. |
| 17 | M&L for preparation of plastered or unplastered new extrernal wall surfaces of walls and applying two coats of exterior emulsion paint over one coat of primer all as specified |
| 18 | M & L for preparation of old treated surfaces of wall including brooming down, scrapping down smoke soots etc. and appying one coat of white wash complete all as specified and as directed. |
| 19 | All as per Item No 18 above but on ceiling surfaces. |
| 20 | M&L for preparation of old treated surfaces of wall surfaces and applying one coat of distemper with distemper oil emulsion white or tinted complete all as specified and as directed. |
| 21 | All as per Item No 20 above but on ceiling surfaces. |
| 22 | M&L for Preparation of old treated wall surfaces including brooming down and applying one coat of exterior emulsion paint complete all as specified and as directed. |
| 23 | M&L for Preparation of old wooden painted surfaces of any description exc 10 cm width or girth and appying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 24 | M&L for Preparation of old steel painted surfaces of any description exc 10 cm width or girth and appying one coat of synthetic enamel paint, complete all as specified and as directed. |
| 25 | M&L for complete removal of existing treatment on wall surfaces and applying two coats of distemper over a coat of wall 3 mm thick care putty by finishing the surfaces even and smooth complete all as specified and directed by EIC. |
| 26 | Dismantling of Stone slabs and tiles laid beded and pointed in any mortar of any description or thickness in floors, aprons etc. |
| 27 | S&F in repairs for pillar taps of 15 mm bore, fancy type with capstan head, chromium plated, screwed down high pressure, with long screwed shanks and fly nuts, screwed for iron pipe & fixed. |
| 28 | S&F of waste pipe of 32mm dia PVC pipe for WHB with long screwed shanks and fly nut flange end beddedd in red lead cement and other end fixed |
| 29 | S&F in repairs for bevelled edge mirror of size 600mm x 450mm selected quality glass mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws. |
| 30 | S&F in repairs Aluminium anodised tubular towel rail 20mm dia D Type 60cm long between flanges. |
| 31 | S&Fin repairs for Vitrious china squattin pan ,Orissa Paattern Size 580x440 mm white with integral foot rests ( Excluding flushing cistern and flush pipe) |
| 32 | S&F in repairs vitreous china wash down water closet pan (pedestal pattern) white (excluding, flushing cistern and flush pipe) complete connected to p trap complete. |
| 33 | S&F in repairs for grating square 150mmx150mm size of stainless steel. |
| 34 | S&F in repairs PVC low level valveless, syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets of 10 Ltr capacity. |
| 35 | Taking up on down steel tubing and connection incl cleaning for refining of the following bore of pipe |
| 36 | 15mm bore of pipe |
| 37 | 20mm bore of pipe |
| 38 | S&F for CPVC pipes ISI marked, IS-15778 with all fittings for hot and cold water, fixed with solvent cement complete to walls and ceilings or laid in floors of following sizes: (SDR-13.5) |
| 39 | 15mm nominal dia of pipes |
| 40 | 20mm nominal dia of pipes |
| 41 | S&F in repairs for bib taps, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for size 15mm bore. |
| 42 | S&Fin repairs stop valve 15 mm dia cast chromium plated screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for unions and fixed. |
| 43 | S&F in repairs for shower rose for 15 mm dia, 125mm long, cast chromium plated screwed down high pressure with long shank screwed end for iron pipe or for unions and fixed. |
| 44 | S&F PVC connection 450mm long with check nut for wash hand basin etc complete all as specified and directed. |
| 45 | S&F in repairs Hand health Faucet spray to EWC with PVC nozzle, and PVC flexible pipe etc complete. |
| 46 | S&F in repairs bathroom cabinet PVC frame box type with mirror in front of size 350x450mm with 6 m thick glass fixed to wall with screws complete all as specified and directed by Engineer-in-Charge. |
| 47 | S&F in repairs Angular stop cock with adjustable wall flange, cast coper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions, and fixed for bore 15mm bore of pipe. |
| 48 | S&F in repairs chromium plated mixing valve, wall mixer 3 in 1 system with provision for both telephone shower and overhead shower complete with wall flange with 115mm long bend pipe including three joints to steel pipe or unions. |
| 49 | S & F in 15mm dia Brass CP central hole basin mixer with 450mm braided connection pipe (without pop-up) for mixing hot & cold water fixed in repairs,complete all as specified and directed by Engineer-in-Charge. |
| 50 | S & F in repairs CP shower roses with CP Arms 125 mm size, 15mm bore, complete all as specified and directed by Engineer-in-Charge |
| 51 | S&F in repairs wash basins, vitreous china, white, rectangular type of size 550x400mm including brackets and cutting for and pinning in ends of brackets or erecting stand 32mm dia waste fittings, brass, chromium plated with long screwed shanks and fly nuts, over and including new brackets complete all as specified and directed. |
| 52 | S&F in repairs chromium plated toilet paper holder. |
| 53 | S&F, in repair 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium road and high density plastic ball screwed for iron pipe and fixed complete all as specified and directed. |
| 54 | Dismantling of cast iron, PVC or reinforced concrete pipes jointed in cement mortar and taking out of trenches, if required all as directed by Engr-in-charge following bore of pipe |
| 55 | 100/110mm dia of pipes |
| 56 | 75mm dia of pipe |
| 57 | S&F of PVC ultra drain,SelFit pipes, single socketed, ISI marked, IS-13592 type 'B' in any length, jointed with solvent cement fixed in walls and floors of following size. |
| 58 | 110mm dia of pipe |
| 59 | 75mm dia of pipe |
| 60 | S&F of PVC junction single 'Tee' equal with door opening, ISI marked, IS-14735, jointed with solvent cement of following sizes. |
| 61 | 110mm dia of pipe |
| 62 | 75mm dia of pipe |
| 63 | S&F of PVC sockets equal, ISI marked, IS-14735, jointed with solvent cement of following sizes. |
| 64 | 110mm dia of pipe |
| 65 | 75mm dia of pipe |
| 66 | S&F of PVC bend equal of any radius with door, ISI marked, IS-14735, jointed with solvent cement for 75mm size pipes. |
| 67 | S&F of PVC bend equal of any radius without door, ISI marked, IS-14735, jointed with solvent cement for 110mm size pipes. |
| 68 | S&F in stainless steel sink with drainage board, made out of 1 mm thick sheet for kitchen or laboratory with plug washer waste pipe cast iron cantilever brckets connecting union overall size 915mm x 460 mm with bowl size 410 mm x 330 mm x 160 mm |
| 69 | S&F in repairs stainless steel plate rack made out of 1mm thick stainless steel sheet, overall minimum size 60cm x 90cm and for 6 plates as approved by GE. |
| 70 | Disconnecting and refixing existing water tanks, setting aside (or lowering if required) for repairs, cleaning etc capacity of tank exc 500 and n.exc 1000 ltr complete all as specified and directed. |
| 71 | S&F in repair pvc tank cover for the tank sizes of 500/750/1000 ltrs including all fittings. |
| 72 | S & F in repair rotational moulded polythene white water storage tank tripple layared (cylindrical , vertical with closed top , ISI marked , ) hoisted and fixed in position all as specd in SSR Part 1 of capacity 500 ltrs including taking down existing tank also including provision of 20 mm bore ball valves , high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum wt 455 gms) |
| 73 | S & F in repair rotational moulded polythene white water storage tank tripple layared (cylindrical , vertical with closed top , ISI marked , ) hoisted and fixed in position all as specd in SSR Part 1 of capacity 750 ltrs including taking down existing tank also including provision of 20 mm bore ball valves , high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum wt 455 gms). |
| 74 | Cleaning & removing all scale and dirt etc from PVC water tank and from mouths of circulating pipes etc of capacity exc. 250 liters and n.exc. 500 ltrs including disconnecting and refixing all parts required to be disconnected for cleaning of the tanks. |
| 75 | All as per item No 63 above but of capacity exc 500 liters and n.exc. 1000 liters |
| 76 | Taking down chowkhat or frames with shutter (without taking off shutters from the frames) n exc 1.5 sqm |
| 77 | Taking down chowkhat or frames with shutter (without taking off shutters from the frames) exc 1.5 sqm but n.exc 4.00 sqm |
| 78 | Taking down shutters of any description exc 1.0 sqm but n.exc 2.00 sqm |
| 79 | Taking down and refixing in same opening after any kind of alteration of shutters of any description of exc 1.0 Sqm but not exc 2.0 Sqm each, complete all as specified and as directed by the EIC. |
| 80 | S&F of pressed steel frames of size 125 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock stricke plate etc., complete as specified. |
| 81 | S&F of pressed steel frames of size 105 x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock stricke plate etc., complete as specified. |
| 82 | M&L for providing cement concrete type B-0, 1:2:4 (using 12.5mm graded stone aggregate) as in roof kerbs, mud stops, filling in frames and the like rounded or or chamfered on edges. |
| 83 | S&F 35mm thick 2nd class hard wood factory made glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc, with sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/ Gauge etc. Size of members of shutters as specified in SSR Part-I, Section 8, clause 8.24(a) complete. |
| 84 | S&F 35mm thick 2nd class hard wood factory made plain framed, paneled shutters (any number of panels), with lock rail and panel of 9mm BWP commercial ply or 12mm veveered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (part-I), kiln seasoned and chemically pressure treated.. |
| 85 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing |
| 86 | S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing |
| 87 | S&F Butt hinges 100mm size, medium weight, cold rolled mild steel. |
| 88 | S&F for 18 mm/ 19 mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination for wooden and fixed with screws to timber frame as in cupboards, shutters, shelves, pelmet etc. including fixing 18 mm wide 6 mm thick beading of Ist class HW (Teak) all around, including dismantling, complete all as specified and directed by Engineer-in-Charge. |
| 89 | S&F Continuous (piano) hinges, stainless steel, bright finish or electro galvanised, 30 mm wide flap (when open), complete all as specified. |
| 90 | S&F for 100mm stainless steel handles complete all as specified and directed. |
| 91 | S&F in repair magnet catcher suitable for kitchen cabinet/coupboard with steel plate and stainless steel as required complete all as specified and as directed. |
| 92 | M&L for preparing new or previously untreated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide or zinc chrome primer on steel surfaces. |
| 93 | M&L for preparing new or previously untreated surfaces wood and wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer on wooden surface |
| 94 | S&F for stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed wih SS wire staples. |
| 95 | S&F for 300mm length of bolt aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cost aluminium alloy all as specified and directed. |
| 96 | S&F for 150mm size extruded aluminium alloy handles, fabricated type, anodised all as specified and directed. |
| 97 | S&F for 100mm size extruded aluminium alloy handles, fabricated type, anodised all as specified and directed. |
| 98 | S&F for aluminium, anodised barrel tower bolt of extruded section and fixed 150mm of size all as specified and directed. |
| 99 | S&F for aluminium, anodised 100mm size of hasp and staple, safety type, with mild steel hinge pin including bolt to hinge plate and fixed with screws all as specified and directed. |
| 100 | S&F for floor door stopper of brass body and tongue with hard drawn steel spring, overall length of cover plate 150mm and fixed all as specified and directed. |
| 101 | S&F for mild steel 300mm long ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 102 | S & F in repairs Double action floor spring Hydrauilically regulated made up of minimum 1.25 mm thick aluminium alloy sheeet foundation box, main body with stainless steel cover governing pivot made of brass, other parts made of mild steel heavy duty and fixed. |
| 103 | S & F door strip (snake guard strip) minimum 18mm wide aluminium body and nylon brushes minimum 22mm wide alongwith screws for fixing complete all as specified as directed. |
| 104 | Taking down aluminium door / window shutter carefully from frames for servicing / including easing, adjusting, replacement of damaged rubber bidding, tighteneing of joints etc complete and make it in functional state ass as directed by Engr-In-Charge. |
| 105 | M &L for aluminium window with double side hung for glazing and gauging and frame with one or more rebates made of anodised aluminium section including section for fixing of aluminium grills with suitable fixtures, jointing cleats for fixing clips, rubber packing, anodised aluminium snap beading screws, anodised aluminium beading screws, type B20 100mm long suitable handle, 75mm long tower bolt and anodised aluminium fittings such as stay, 75mm long butt hinges glazing with 5mm thick tinted sheet glass fixed with solarcontrol film25 micron reflective type and gauging with aluminium wire cloth of size 0.45mm dia of wire and 1.40mm apertur except fixed glazing (FG) all as specified and directed. (Tint of glass shall be approved by GE).Note :- (i) Aluminium grill fixed under above item shall be measured and paid separately.(ii) Size of Aluminium Section for frame - 100x45x1.2mm(iii) Size of Aluminium Section for shutter - 85x45x45x1.2mm(iv) Size of Aluminium Wiremesh shutter - 40x18x1.2mm |
| 106 | S&F anodised aluminium grill (diamond shape of approx size 100x100mm) made out of aluminium \\"Y\\" section as aproved by Engineer -in-Charge for window /ventilators etc complete all as specified and directed |
| 107 | S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed wih stainless steel wire staples. |
| 108 | Hacking out old broken glass (any thickness, size, quality or description) from wooden /steel frames or stone , concrete or brick surrounds, glazed with putty or fixed with beads. |
| 109 | M&L 4.00 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 Sqm in each pane. |
| 110 | Dismantling of wall and ceiling boards (fibre, pulb, insulation etc or insulation boards /slabs / blankets any thickness including cover fillets |
| 111 | M&L for 12 mm thick peformated particle board / tiles for insulation and accoustic purpose 60x60 cm in size fixed with nails to timber frame work or with staples on snap grid |
| 112 | Removing of old water proofing treatment including screed bed and cleaning the surface of slab with wire brushes removing dust, foreign materials including flushing at junction of wall and removing the rubbish off the premises to a distance exc. 500m, complete all as specified and as directed Engr-in-Charge. |
| 113 | M&L, water proofing treatment on roof and preparing the surfaces to receive WPT treatment , applying cold bituminous primer @ 0.30 ltr / Sqm conforming to IS 3384 applied on plastered surfaces including side walls , followed by a layers of APP based polymeric membrane reinforced with polyster non woven fabric (weighing 3.5 Kg/Sqm(minimum) and 3 mm thick) with mineral finish laid on primed surface by torch application with side overlap 100 mm and ends over laps 150 mm , joints sealed properly as per manufacturers instructions all as specified and directed . |
| 114 | M&L for 75 mm thick cement concrete type C-2 (1:3:6) using 40 mm graded stone aggregate as in sub base under interlocking tiles. |
| 115 | Material and labour for 25 mm thick sand filling under floor including consolidation complete all as specified all as specified. |
| 116 | M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade |
| 117 | Dismanteling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings. |
| 118 | M&L Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws asspecified. |
| 119 | M & L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing etc complete. |
| 120 | M&L Kota stone slab 20-25mm thick (mirror polished) in riser of steps, skirting, dado and pillar including laid over and including mortar CM 1:4 for 10mm thick including nosing, bell mouth, making grooves as required complete. |
| 121 | Pulling down the existing U/S wires of any type from concealed wiring carefully of aluminium/copper point wiring (light, fan, bell, socket, power point etc.) with or without conduit, along with all connected accessories such as ceiling rose, switches, sockets, switch boards, fan regulator etc complete all as specified and as directed by the Engr-in-Charge |
| 122 | Pulling out sub main wiring only any size of aluminium conductor cable PVC insulated with or without condiut complete all as specified and as directed by the Engr-in-Charge |
| 123 | Material & labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through and including PVC CASING & CAPPING INCLUDING accessories etc including fixed to wall/ceiling including provision of 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed as earth wire continuity with PVC surface box complete all as specified and directed by Engineer-in-Charge for :- |
| 124 | One light point controlled by one, one way switch single pole piano type. |
| 125 | One Fan point controlled by one, one way switch single pole piano type. |
| 126 | One 3 pin 5 Amp socket outlet on the same board. |
| 127 | One 3 pin 5 Amps socket out let on independent board. |
| 128 | One bell point controlled by one bell push on independent board. |
| 129 | All as per item No.120 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board complete all as specified and directed by Engineer-in-Charge. |
| 130 | Material & labour for point wiring complete with 1.5 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through existing conduit including provn of 1.5 sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed as earth wire continuity with new plastic laminated white coloured top sheet cover 3.0 mm thick on existing sunken box complete all as specified and directed by Engineer-in-Charge for :- |
| 131 | One light point controlled by one, one way switch single pole piano type. |
| 132 | One Fan point controlled by one, one way switch single pole piano type. |
| 133 | One 3 pin 5 Amp socket outlet on the same board. |
| 134 | One 3 pin 5 Amps socket out let on independent board. |
| 135 | One bell point controlled by one bell push. |
| 136 | All as per item No.122 here-in-before but with 2.5 Sqmm Copper conductor cable for one 3 pin, 15 Amps socket out let on independent board complete all as specified and directed by Engineer-in-Charge. |
| 137 | Material & labour for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor drawn through and including PVC casing caping ISI marked with accessories and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge.(Note: Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit) |
| 138 | Material & labour for sub main wiring with two runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 6 Sqmm single core, copper conductor drawn through and including PVC casing caping ISI marked with accessories and 6 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge.(Note: Two runs of conductor with one run of earth wire and PVC casing capping will be measured & paid as one unit) |
| 139 | Material & labour for sub main wiring with four runs of PVC insulated and unsheathed FRLSH cable 650/1100 Volts grade, conforming to IS-1536-1977 multi-stranded 4 Sqmm single core, copper conductor in existing conduit and 4 Sqmm single core multistranded copper conductor FRLSH PVC insulated and unsheathed cable 1100 volts grade, ISI marked as earth continuity wire complete all as specified and directed by Engr-in-Charge.(Note: Four runs of conductor with two run of earth wire will be measured & paid as one unit) |
| 140 | Supply & fix in replacement energy saving, evironment friendly, long life, corrosion resistent, impact proof, Mini LED building security light made up of pressure die cast housing with prismatic polycarbonate diffuser and individual LEDs with secondary optics and IP 65 protection with LED 20 W light source including material and labour for suitable bracket made of 20 mm dia light grade GI pipe & MS clamps complete with nuts and bolts and washers complete all as specified and directed by Engineer-in-Charge. |
| 141 | Supply and fixing in repairs wall mounted decorative ultra slim LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 10 W 2 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting etc complete all as specified and directed by Engr-in-Charge |
| 142 | Supply and fixing in repairs wall mounted decorative ultra slim LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready to use pack instant start with uniform light distribution 18/20 Watt 4 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting etc complete all as specified and directed by Engr-in-Charge |
| 143 | Supply & Fixing in replacement of isolators/MCBs, etc. in distribution board of the following rating and capacities. |
| 144 | MCB TPN 415 Volts 63 Amp capacity, 10 KA |
| 145 | MCB SPN of 240Volts 20/32/40 Amps Capacity, 'C' series, 10 KA |
| 146 | MCB SP of 240Volts 5-40 Amps Capacity, 'C' series, 10 KA |
| 147 | Supply & fix in replacement capacitor of capacity 2.5 MFD (PVC Body) suitable for ceiling/ Exhaust fans/ Wall mounted fans of any description any sweep complete all as specified and directed by Engineer-in-Charge. |
| 148 | Taking down and refixing ceiling fans/exhaust fans of any sweep any size from site for repair complete all as specified and directed by Engineer-in-Charge. |
| 149 | Material & labour for taking out & removing old burnt-out windings of ceiling fans of any description and rewinding of fan motor with appropriate size super enameled copper wire as approved by Eng-in-charge including insulating material such as illuminous paper,Letherized paper,cotton tape,glass sleeving,insulating varnish ,Bearing ,Bushes,capacitor etc.and transportation to site after testing at workshop,connecting and testing on full load to the entire satisfaction of Eng-in-charge,including painting of fans of any description(ceiling fan/exhaust fan/wall mounte fan/pedestal fan) with applying one coat of synthetic enamel paint(white/Grey) by spray machine including preparation of exisiting decorated surfaces of fans complete all as specified and directed by Engineer-in-charge. |
| 150 | Material & labour for servicing of 1200/1400MM ceiling fan by dismantling carefully and taking out unserviceable parts, dust & grease, cleaning of internal parts with kerosene oil, washing, checking of alignment of shaft, oiling and re-greasing of bearing/bushes including replacing of unserviceable part like bearing ,gun metal bush, capacitor,Rubber reel of suitable capacity and re-assembling the same and complete all as specified and directed by Engineer-in-charge. |
| 151 | Supply & fix in replacement of PVC body exhaust fan, AC single phase 230/240V of size 250 mm sweep with louvers including making hole of suitable size/ alteration to the existing hole to fix the Exhaust fan complete all as specified and directed by Engineer-in-charge. (Note: Old unserviceable Exhaust Fan will be deposited in MES store yard). |
| 152 | Supply & fix in replacement of PVC body exhaust fan, AC single phase 230/240V of size 300 mm sweep with louvers including making hole of suitable size/ alteration to the existing hole to fix the Exhaust fan complete all as specified and directed by Engineer-in-charge.(Note: Old unserviceable Exhaust Fan will be deposited in MES store yard). . |
| 153 | Supply & fix in replacement of metal body exhaust fan, AC single phase 230/240V of size 300 mm sweep with louvers including making hole of suitable size/ alteration to the existing hole to fix the Exhaust fan complete all as specified and directed by Engineer-in-charge.(Note: Old unserviceable Exhaust Fan will be deposited in MES store yard). . |
| 154 | Supply & fix in replacement, switch piano type, 5 Amp. SP, one way complete all as specified and directed by Engineer-in-charge. |
| 155 | Supply & fix in replacement socket outlet 3 pin, 5A, flush complete all as specified and directed by Engineer-in-charge. |
| 156 | Supply & fix in replacement switch socket combination, 2 in 1, 5 Amp, flush type complete all as specified and directed by Engineer-in-charge. . |
| 157 | Supply & fix in replacement switch socket combination 2 in 1, 5/16A 5 in 1 Amp flush type universal complete all as specified and directed by Engr-in-Charge. . |
| 158 | Supply & fix in replacement switch bell push, flush type, 5 Amp complete all as specified and directed by Engr-in-Charge. |
| 159 | Supply & fix in replacement bell, AC, 230 V, SP, ding dong type complete all as specified and directed by Engr-in-Charge. |
| 160 | Supply & fix in replacement stepped type electronic fan regulator flush type on the existing phenolic laminated etc as reqd single pole 240 volts grade 350 watts heavy duty ISI marked complete all as specified and directed by Engr-in-Charge. |
| 161 | Supply & fix in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engr-in-Charge. |
| 162 | Supply & fix in replacement of ceiling rose 3 phase, PVC/ Polycarbonate body complete all as specified and directed by Engr-in-Charge. |
| 163 | Supply & fix modular plastic surface box of module 1/2 flush ISI marked complete all as specified and directed by Engineer-in-Charge. |
| 164 | Supply & fix modular plastic surface box of module 3 flush ISI marked complete all as specified and directed by Engineer-in-Charge. |
| 165 | Supply & fix modular plastic surface box of module 4 flush ISI marked complete all as specified and directed by Engineer-in-Charge. |
| 166 | Supply & fix modular white cover plate with frame of module 2 flush ISI marked complete all as specified and directed by Engineer-in-Charge. |
| 167 | Supply & fix modular white cover plate with frame of module 3 flush ISI marked complete all as specified and directed by Engineer-in-Charge. |
| 168 | Supply & fix modular white cover plate with frame of module 4 flush ISI marked complete all as specified and directed by Engineer-in-Charge. |
| 169 | Supply & fix modular blank plate module 1 all as specified and directed by Engineer-in-Charge. |
| 170 | Supply & fix in replacement modular switch flush type SP one way, 6 Amp, 1 module ISI Mark complete all as specified and as directed by the Engr-in-Charge |
| 171 | Supply & fix in replacement modular socket outlet 3 pin,6 Amp, flush type 2 module, ISI marked complete all as specified and as directed by the Engr-in-Charge |
| 172 | Supply & fix in replacement modular swicth, 16 Amp flush type 1 module complete all as specified and directed by Engr-in-Charge. |
| 173 | Supply & fix in replacement modular socket outlet, 3 pin, 6/16 Amp flush type 2 module complete all as specified and directed by Engr-in-Charge. |
| 174 | Supply & fix in replacement modular bell push, flush type, 6 Amp,1 module complete all as specified and directed by Engr-in-Charge. |
| 175 | Supply & fix in replacement of ceiling fan regulator 120 Watt 2 module Modular type electronic step type 5 step 360 deg complete all as specified and directed by Engr-in-Charge. |
| 176 | Supply and repair hylum sheet 3mm thick as existed in the switch board making provision for fixing switches and socket complete all as specified and directed by Engr-in-Charge. |
| 177 | Material & labour for disconneting electrically and mechanically the existing geyser of any description,any capacity and make/type and in any position for repair/replacement/painting/cleaning etc including disconneting existing cold and hot water pipe connections, strip opening of geyser for descaling of tank element, thermostate,inlet/outlet water pipe connection etc using suitable chemical/wire brush,replacement of unserviceabe parts, re-assembling the same after,repair/descaling, fixing in position including, connecting inlet/outlet water pipe connection, electrical connections any testing of geyser complete all as specified and directed by Engineer-in-charge. |
| 178 | Supply & fix in replacement metal plug top 20Amps 3 pin complete all as specified and directed by Engineer-in-charge. . |
| 179 | Supply & fix in replacement 2.0 KW electric heating element at site including rubber ring washers ISI marked complete all as specified and directed by Engineer-in-charge. |
| 180 | Supply & fix in replacement for PVC connection with brass nipple 15 mm x 450 mm long for geyser 25/50 ltrs capacity as per sample complete all as specified and directed by Engineer-in-charge. |
| 181 | Labour only for attending emergent complaints i.e no light ,earth leakage,short circuit,neutral break,mains/submain/internal circuit of existing system of main building/block,making continious electric supply including carrying out minor repairs etc as required to make the system in order/functional including replacing fuse wire,copper cable,copper thimbles,glands,earthing wire complete all as specified and directed by Engineer-in-Charge.Note:-1.Rate of Fuse wire,copper cable of size 1.5,2.5,4 Sqmm upto 3 RM,copper thimbles,glands,earthing wire are deemed to be considered in this item. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 15, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysSep 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 13 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender