Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #57340274

Tender For Miscellaneous Repair / Maintenance Work Of Various External Electric Supply Items, Lt Panals, Under Ground Cable And Other Allied Wks At Zone -I Under Age (I) Nyoma

Issued by Statutory Bodies & Commissions/Committees · nyoma, Jammu And Kashmir
Tender Value
9.80 Lakhs
Estimated cost
Bid Submission
24 Sep 2026
11 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
nyoma → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Miscellaneous Repair / Maintenance Work Of Various External Electric Supply Items, Lt Panals, Under Ground Cable And Other Allied Wks At Zone -I Under Age (I) Nyoma

BOQ

Name of Work:- Misc repair / maint work of various external electric supply items, LT panals, under ground cable and other allied wks at Zone -I under AGE (I) Nyoma
Sl. No. Item Description
1Taking out un-serviceable/faulty cable/service connection cable of any grade / type / class of any size for repair / replacement from pole / wall / cable duct under ground trench etc for re-use or removal from site of work all as specified and as directed by the Engineer-in-charge (Note- Excavation and earth work shall be measured and paid separately)
2Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 2 core 16 sqmm, complete all as specified and directed by Engr-in-Charge.
3Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 4 core 16 sqmm, complete all as specified and directed by Engr-in-Charge.
4Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 35 sqmm , complete all as specified and directed by Engr-in-Charge.
5Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 50 sqmm, complete all as specified and directed by Engr-in-Charge.
6Supply, laying,fixing, passing through pipe or laid in trenches and testing underground XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross section area 3.5 core 70 sqmm, complete all as specified and directed by Engr-in-Charge.
7Supply and fixing Aluminium bus bar chamber 3 phase, 200 Amp capacity with 4 nos Al strips not less than 600 mm long, outdoor type including one MCCB of 125 Amps 4 Pole as incommer with locking arangement, grouting in pcc 1:3:6 and connecting with UG XLPE cable with suitable copper thimbles, complete all as specified and directed by Engr-in-Charge.
8M&L for Earthing complete with galvanized steel earth plate electrode 600x600x60mm thickness not less than 6mm thick buried directly in ground( earth plate not less than 2.25 mtr deep below normal ground level) with top edge of earth plate not less than 2.5 mtr below the normal ground level connected to galvanized iron wire 4 mm dia by means of nuts bolts, nuts, check nuts and washers of GI steel all as shown in electrc plate Ni 5 connected to earth test point all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe light grade 40mm bore and GI watering pipe 20mm bore medium grade with funnel and wire mesh ,40mm thick pre cast RCC M-15 ( Nominal mix) cover reinforced with XPM weight not less than 4 Kg/Sqm with suitable handle of 6mm dia MS bar and angle iron 40X40X3mm frame for cover,PCC M-15 ( Nminal mix) pit, excavation and earth work in any type of soil and connected all as specified and as directed by Engineer-in-charge.
9Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtrs in depth for laying of cable, fixing of stay etc 10 Sqm on plan and n exc 1.5 in depth and getting out in hard/dence soil complete all as specified and directed by Engineer-in-Charge.
10Returing, filling in incl spreading, levelling watering and well remming in layers n.exc 25cm width, Complete all as specified and directed by Engineer-in-Charge.
11Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5 m above starting point Completed all as specified and diercted by Engineer-in-Charge.
12Supply and fix Double wall corrugated (DWC) outer pipe 63 mm and inner dia 50 mm fix complete to Wall, Poles etc with suitable clamp for protection of cable, complete all as specified and directed by Engr-in-Charge.
13Supply and fix Double wall corrugated (DWC) outer pipe 110mm and inner dia 95 mm fix complete to Wall, Poles etc with suitable clamp for protection of cable, complete all as specified and directed by Engr-in-Charge.
14M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick burried directly in ground not less than 2.25m deep below normal ground level (with the top edge of the plate not less than 1.50 m below the normal ground level) connected to GI strip 32 x 6 mm by means of GI bolts, nuts, check nuts and washers of GI all as shown in electrical plate No.3 of SSR Part-I connected to earthing test point with and including necessary excavation and earth work in any strata PCC pit 1:3:6 type C-1, 20mm bore medium grade GI pipe for watering 15mm bore light grade pipe for GI wire protection and funnel including 40mm thick RCC slab cover and testing on completion, complete all as specified and directed by Engr-in-Charge.
15Supply and installation erection commissioning and testing of main LT pannel cubical out door type weather/dust proof, factory made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable alley and front side shutter with locking arrangement panel base of angle iron 50x50x6mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including four pole aluminium bus bar 400 Amps capacity including control wiring with suitable size of PVC insulated standed copper conductor and incoming/outgoing connection with aluminium bus bar complete as per manufacture design complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of aluminium lugs and glands complete comprising the following, as specified and directed by Engr-in-Charge.:-
16MS Sheet body of LT Panel With double door angle iron frame
17Incomming
18(a) MCCB,125 Amps, 36 KA Optium 1.0 (Fixed TM range) 4 pole -01 Nos Incoming
19Outgoing
20(b) MCCB, 63 Amps, 16 KA, Optium 1.0 (Fixed TM range) 4 pole -03 Nos Outgoing
21(c) MCB TPN 16-32 Amps415 Voit, 16 KA -.4 Nos
22(d) LED type phase indicattor lamp (R Y B) - 01 Set
23(e) Digital ammeter 0-400A flush type square with selector switch & CTs 3 Nos - 01Set
24(e) Digital voltmeter 0-500V flush type square with selector switch - 01 Nos
25(h) Change over 160 Amps-01 Nos
26Note:- Drawing and Technical Specificition of LT pannel should be pass by Engr in Charge before supply and dispatch of the pannel, complete all as specified and directed by Engr-in-Charge.
27Repair and maintance of LT out door fedder piller of different capacity and location , complete all as specified and directed by Engr-in-Charge :- (a) Repair abd maintance of broken door by welded or by Change of door and spray two coats of synthetic enamel paint smoke grey colour (1st guality) over a coat of primer. (b) Repair and maintance of Voltmeter and ammeter. (c) Repair and maintance of Busbar of existing capacity and size. (d) Repair and maintance of indicator lamp. (e) Repair and maintance of cable glands, cable lugs, nut, bolts, washers etc. Note- Cost of MCCB and change over required will be paid and masured seperately.
28Supply and fixing in replacement of change over switch 4 pole 415 volts 200 Amp in conforming to IS02 with front operated handle complete with fixing in existing LT Panel, complete all as specified and directed by Engr-in-Charge.
29Supply and fixing in replacement of change over switch 4 pole 415 volts 100 Amp in conforming to IS00 with front operated handle complete with fixing in existing LT Panel, complete all as specified and directed by Engr-in-Charge.
30Supply and fixing in replacement of change over switch 4 pole 415 volts 250 Amp in conforming to IS02 with front operated handle complete with fixing in existing LT Panel, complete all as specified and directed by Engr-in-Charge.
31Supply and fix 4 Pole MCCB 200 Amp, 50 Hz, 415 V with adjustable type release and rupturing capacity 36 KA, complete all as specified and directed by Engr-in-Charge.
32Supply and fix 4 Pole MCCB 125 Amp, 50 Hz, 415 V with adjustable release and rupturing capacity 16 KA, complete all as specified and directed by Engr-in-Charge.
33Supply and fix 4 Pole MCCB 63 Amp, 50 Hz, 415 V with adjustable type release and rupturing capacity 16 KA, complete all as specified and directed by Engr-in-Charge.
34M&L for Aluminium cable lugs / thimbles suitable for cable of size 16 to 35Sqmm, complete all as specified and directed by Engr-in-Charge.
35M&L for Aluminium cable lugs / thimbles suitable for cable of size 50 to 100Sqmm, complete all as specified and directed by Engr-in-Charge.
36Supply, jointing and testing straight through, heat shrinkable, jointing kit suitable for PVC/ XLPE insulated armoured heavy duty aluminium conductor 1100 volt grade of size 10/16 Sqmm, 4 core including taking out faulty portion of cable in any situation/ position, complete all as specified and directed by Engr-in-Charge.
37All as per srl item No 25.00 here in before but for cable of size 25/35 Sqmm, 3.5 core, complete all as specified and directed by Engr-in-Charge.
38All as per srl item No 25.00 here in before but for cable of size 50/70 Sqmm, 3.5 core, complete all as specified and directed by Engr-in-Charge.
39Supply, jointing and testing End Joinyt, heat shrinkable, jointing kit suitable for PVC/ XLPE insulated armoured heavy duty aluminium conductor 1100 volt grade of size 10/16 Sqmm, 4 core including taking out faulty portion of cable in any situation/ position, complete all as specified and directed by Engr-in-Charge.
40All as per srl item No 28.00 here in before but for cable of size 25/35 Sqmm, 3.5 core, complete all as specified and directed by Engr-in-Charge.
41All as per srl item No 28.00 here in before but for cable of size 50/70 Sqmm, 3.5 core, complete all as specified and directed by Engr-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57340274
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 9.80 Lakhs
LAST DATE 24-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Miscellaneous Repair / Maintenance Work Of Various External Electric Supply Items, Lt Panals, Under Ground Cable And Other Allied Wks At Zone -I Under Age (I) Nyoma
Basic Detail
Tender No 8100/NIT-25
Bidding Type Tender
Location
City nyoma
State Jammu And Kashmir
Key Dates
Publish Date 03 Sep 2026
Submission Date 24 Sep 2026
Open Date 26 Sep 2026
Finance
Tender Value 9.80 Lakhs
Tender Fee 500
EMD 20000
Exemption Not Available
Document List
5c54288c-16db-453a-b194-e9b333403e40.html
BOQ_882684.xls
Tender25.pdf
Tendernotice_1 (8).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Sep 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 13 days

Tender Documents

Download All (ZIP) ↓
html

5c54288c-16db-453a-b194-e9b333403e40.html

xls

BOQ_882684.xls

pdf

Tender25.pdf

pdf

Tendernotice_1 (8).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders