Public Administrative Department Cooperative Closing in 4 days TDR #57336305

Tender For Construction Of Construction Of Work Shed For Shgs At Kulgachi Skus Ltd.,Block-Balagarh, Dist.- Hooghly,Under Pm-Rkvy 2026-27 .

Issued by Cooperative · Kolkata, West Bengal
Tender Value
28.53 Lakhs
Estimated cost
Bid Submission
19 Sep 2026
4 days left
EMD
57060
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Construction Of Work Shed For Shgs At Kulgachi Skus Ltd.,Block-Balagarh, Dist.- Hooghly,Under Pm-Rkvy 2026-27 .

BOQ

Name of Work:- Construction of Construction of Work shed for SHGs at Kulgachi SKUS Ltd.,Block-Balagarh, Dist.- Hooghly,under PM-RKVY 2026-27 .
Sl. No. Item Description
1(A) Civil Work, Work shed for SHGEarth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm.
2(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
3Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
4Pre-constructional Anti-termite measures:- Antitermite treatment to bottom surface ( in case of masonry foundation and basements) and the sides ( upto a height of 300 mm. from bottom) of the excavation trenches with chemical emulsion by admixing Imidacloprid emulsifiable concentrates (105ml in 50 litres) with water at the rate of 5 Litres per sq. m. area. The work shall be carried out as per specification described in 7.2.1. of code IS-6313 (part -II) 2013. ( Mode of measurment will be the plan area of foundation treated.)
5Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
6Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work
7Cement concrete with graded stone ballast (40 mm size excluding shuttering (A) Pakur Variety (1:3:6)In ground floor
8Reinforcement for reinforced concrete work in the all sorts of structures including distribution bars, stirrups, binders etc. including supply of rods, initial straightening and removal of loose rust (if necessary ),cutting to requisite length . hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every inter-section, complete as per drawing and direction.(a) For works in foundation, basement and upto roof of ground floor /upto 4 m.(ì) Tor steel/Mild steel I. OTHER MANUFACTURERS NOTSPECIFIED
9Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.
10Brick work with 1st class bricks in cement mortar (1:6) as specified a) In foundation and plinth
11Brick work with 1st class bricks in cement mortar (1:6) as specified b) In superstructure, ground floor
12Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation offoundation.
13M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. Payment to be made on the basis of calculated weight of structural memebrs of MS Holow Section as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a hight of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof.i) For roof truss worksa) Span up to 12 Mtr
14Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed. (i) 16 mm dia bolt (a) 300 mm long
15Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapizoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be madeon area of finished work). (i) In Roof:- a) With 0.5 mm thick sheet
16Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping) (A) 300 mm lapping each way (b ) With 0.63 mm sheet
17Galvanised iron sheets valley gutter with perimeter not less than 750 mm with 225 mm lap each way fitted and fixed with necessary bolts, nuts, screws, etc.complete. Valley gutter made of 0.63 mm. thick sheets. (300mm End lapping)
18Labour for Chipping of concrete surface before taking up Plastering work.
19Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including scaffolding/staging where necessary (Ground floor).[Excluding throating, nosing and drip course,cost of chipping over concrete surface] (i) With 1:6 cement mortar 15 mm thick plaster
20Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including scaffolding/staging where necessary (Ground floor).[Excluding throating, nosing and drip course,cost of chipping over concrete surface] (ii) With 1:4 cement mortar 10 mm thick plaster
21Neat cement punning in plinth outside face, bunker floors, stair railings etc. at all elevations
22Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] a) 20mm thk. Plaster with (1:6) cement sand mortar Ground floor.
23Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
24M.S.or W.I. Ornamental grill of approved design jointscontinuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in ground floor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.
25Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : With super gloss (hi-gloss) : (i) Two coats (with any shade except white) (b) On steel or other metal surface :
26Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand
27Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor) (b) Two Coats, ii) Solvent based interior grade Acrylic Primer
28Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) :(Two coats) i) Standard Quality
29Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. Two Coats
30Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. In Ground floor (Two Coat) Premium 100% Acrylic Emulsion
31Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete. A) UPVC Pipes: 110 mm. Dia.
32B) UPVC Fittings: c) Bend 87.5 degree - 110 mm. Dia.
33d) Shoe- 110 mm. Dia.
34Supplying and laying true to line and level High Grip, Scratch resistant,Neutral to UV rays, Full Body Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and tested in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance: 0.6, Mohr's hardness > 7.0, Staining resistance: Class-1, Water Absorption E < 0.5%] & MOR > 35N/sq.mm and Breaking strength >1500 N for Outdoor area of building e. g. Gang-way, Corridor, Driveway,Parking lots, Courtyards, Sloping ramps, Entrance lobbies, Patios, Portico etc.set over necessary underlay and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles and removal of wax coating of top surface of tiles with warm water and cleaning the tiles using soft and dry cloth complete including the cost of materials, labour and all other incidental charges complete including backside slurry but excluding the cost of underlay and true to the manufacturer's specification and direction of Engineer-in-Charge.In Ground Floor: Sizes-300 mm x 300 mm x10 mm
35Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr's hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to themanufacturer's specification and direction of Engineer-in-Charge. (Whitecement, synthetic adhesive and grout material to be supplied by the contractor). a) In Ground Floor: Sizes-300 mm x300mm x10 mm with breaking strength >1200 N
36Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (i) Coloured decorative
37Providing and fixing PVC Door Frame of size 50x47mm with a wall thickness of 5mm (± 0.2 mm) made out of single piece extruded PVC profile, with mitred cut joint sand joint with 2 nos. of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 mm x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20mm M.S. rectangular tube of 0.8 mm ,including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The doorframe to be fixed to the wall using 8 x100mm long anchor fasteners complete, all as per manufacturer‟s specification and direction of Engineer -in- charge.
38PVC Door Shutter-30 mm thick: Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of 59 mm x30 mm section with 2.0 mm (+/-0.2 mm) wall thickness.Horizontal & vertical section shall be fixed to each other by self tapping screws and 1 solid polymeric or M.S. galvanised tubular 'L' shaped bracket 100mm x 200mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 120 mm x30mm with 2.0 mm (+/- 0.2mm) wall thickness will be fitted in the middle, reinforced by solid polymer bar of 200 mm long at both ends and screws from both sides as lock rail. The section frame will then be fitted in by PVC panels of size 100 mmx25 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliancesi/c carriage of all materials taxes and all other incidental charges complete.
39Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover (heavy type) of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 :1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C (1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. (ii) For 20 users with pakur varity (OTHER MANUFACTURERS NOT SPECIFIED)
40Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and1.00m inside dia. (OTHER MANUFACTURERS NOT SPECIFIED)
4140 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weightof cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures.
42Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film I) Natural whitea) 2- track sliding windowi) Bottom frame
43Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film I) Natural whitea) 2- track sliding windowii) Top and side frame.
44Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film I) Natural white d) Shutter for all track sliding window.i) Bottom & Top member.
45Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film I) Natural whited) Shutter for all track sliding window.ii) Style side member.
46Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film I) Natural whited) Shutter for all track sliding window.iii) Interlock member.
47Supplying maruti lock (100mm)
48Supplying EPDM gusket of approved make and brand as per direction of Engineer in charge. i) For sliding windows b) 'U' shaped EPDM gasket for frames.
49Supplying PVC rollers for sliding windows as per direction of Engineer in charge.
50Labour charge for fabrication and installation of composite door,window, partitions made from annodized extruded alloy aluminium sections for the following units:-(A) Glazed aluminium sliding windows made of extruded and annodized alloy aluminium sectios, fabrications, including cutting to proper shape and size, drilling and aligning of window shutter frame fitted with in built locking arrangements, sliding rollers and other necessary fittings, fixture, adhesives and joineries along with extruded neoprine or EPDM gasketing in between window frame and masonry work (walls, column,beam.lintels etc.) as well as between glass and shutter frame for fixing glass and Polysulphide sealant and in between shutter and window frame where necessary including cutting to requisite size and fixing glass as per drawing, specification and direction of EIC. The rate includes the hire charge of all tools and plants, including allincidental charges, adhesive, joineries such as screw, cleat angle etc. but excluding the cost of extruded aluminium sections, glass, neoprene / EPDM gasket, locking arrangement and rollers. i ) 2 track sliding window.
51Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. ii) 4mm thick coloured / tinted / smoke glass.
52Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. With 'P' trap
53Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.
54Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps completei) Polythene Flush Pipe
55Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75mm X 75 mm X 75 mm wooden blocks complete. - 470mmx280mmx340mm.
56Supplying, fitting and fixing urinal flush pipe fittings of approved brand(c) C.P. urinal flush pipe fittings range of one
57Supplying, fitting and fixing PVC pipes of approved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (a) For Exposed Work PVC Pipes a) 25mm dia. Pipes
58b) 15mm dia. Pipes
59c) 40mm dia. Pipes
60Supplying, fitting and fixing with cement jointing (3:1) salt glazed stoneware pipe including excavation of earth upto 1.50 metre depth in all sorts of soil both mixed or unmixed and refilling (but excluding concreting at bottom and sides). (iv) 100 mm
61Supplying, fitting and fixing with cement jointing (3:1) with jute gasket soaked in cement mortar. (a) Stoneware bend (iv) 100 mm
62Supplying fitting & fixing stone ware T/Y junction with cement jointing (1:3) with jute gasket soaked in cement slurry in position complete as directed - 100mm dia.600mm long.(Single)
63Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass- 25mm dia., 600mm long
64Supplying, fitting and fixing soap holder..PTMT(Prayag or equivalent)
65Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges.-600 mm X 450 mm
66Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer - (a) 500 litre capacity
67Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. (a) Upto 1st story from G.L.
68Labour for punching hole in plastic water storage tank upto 50 mm dia.
69Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks,C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. 550 mm X 400 mm size
70Supplying, fitting and fixing bib cock or stop cock. Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand)
71Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark. (v) 75mm. X 60mm. X 3.15mm.
72Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixedwith cadmium plated screws: (ii) 75mm long x 10mm dia. bolt.
73Iron door ring of approved quality fitted and fixed with nut and washer complete. (i) 75mm dia.
74Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film., I) Natural white, h) Louvered window. i) Top, bottom and side member.
75Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film., I) Natural white, h) Louvered window. ii) Louvered Section.
76Supplying profiles of required section made of Aluminium Alloy Extrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized (with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding & casement windows, partitions, formed of basic sections of any ISI embossed / certified make and brand as per direction of Engineer - In- Charge. (Payment will be made on finished length of the work). (A) In 10-12 Micron thickness Annodizing film., I) Natural white, h) Louvered window. iii) Cleat angle ( Non-annodized).
77Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx)
78(B) TUBE WELLLabour for boring tube well of required dia. by water jet system through any type of soil strata including hire and labour charges for boring pipes,scaffolding, tools and plants as necessary and taking out them and lowering pipes, strainers, blind pipe etc. and fitting and fixing the same complete including bucket washing and other incidental works in the connection. The tube well should have a minimum 50 mm gap in between the outside of the tubewell pipe and the bore.(d) For depth upto 150 metre for 50 mm dia. tube well with topenlargement of 100 mm dia.(i) 50 mm dia. boring etc.
79(ii) 100 mm dia. boring etc. top enlargement
80Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). A) PVC Pipes (Dia)50 mm
81Supply of PVC pipes & fittings Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). A) PVC Pipes (Dia)100 mm
82Supplying high density polythene strainer of approved make with adapter conforming to I.S. specifications.(ii) 50 mm dia
83Supplying, fitting and fixing plug of approved make conforming to I.S. specifications.50mm dia
84Supplying,fitting and fixing check valve (horizontal) G.M. tested to 21 kg per sq. cm.50mm dia
85Supplying, fitting and fixing heavy type bell mouth reducing socket.ii) 50 mm X 100 mm
86Supplying, fitting and fixing G.I. cap at top 100mm
87Labour for making arrangement for showing verticality test including the cost for hire charges of tools and plants, scafolding, labour etc. all complete.
88Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required.
89Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction.
90Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-incharge including cost of all materials labour and equipment complete.
91Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete.
92Providing and fixing bell plug as required upto 250 mm (internal) dia. ERWMS pipe including cost of materials and labour complete.
93Supplying, fitting and fixing 300 mm M.S. housing clamp of approved quality.
94Providing 200 mm centre guide with Clamp
95Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report.
96Supplying KSB Submersible Pump and Motor Set 1.5 H.P. , 220 Volts,. It includes Control Panel .
97(C) Electrical WorksSupplying and fixing 415V FP 63A Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc [Approved make] as directrd by EIC.
98Supplying and fixing Sheet steel 60/63 A Main Switches 415V TPN with fuse on L&N on flat iron frame on wall [Approved make] as directrd by EIC.
99Supplying & fixing sheet metal (16 SWG) Iron Clad 4 bars 415 V, 100/125 A Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991) [Approved make]
100Supplying and fixing double door Horizontal 6 way TPN MCB Distribution board with IP-42/43 protection, on wall surface & mending good thedamages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [Approved make]
101Supplying and fixing 240/415 V 63A FP MCB Isolator on din rail of existing for TPN DBs and necessary connection. [Approved make]
102Supplying and fixing 240/415 V 6-32A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing for TPN DBs and necessary connection. [Approved make]
103Distribution wiring in 1.1 KV single core stranded 'FR'PVC insulated & unsheathed copper wire [Approved make] in 20mm size PVC rigid conduit 'FR' incl. necy. fittings as required (a) {2 x 4 sqmm + 1 x 2.5 sqmm} for [Approved make] [Approved make]
104(b) {2 x 2.5 sqmm + 1 x 1.5 sqmm} for [Approved make]
105(c) {3 x 1.5 sqmm} for [Approved make]
106Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single corestranded 'FR' PVC insulated & unsheathed copper wire[Approved make] in 20mm size PVC rigid conduit 'FR' [Approved make], with 1x22/0.3 (1.5 sqmm) single corestranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mm x 100mm x 65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish (a) Average run 5 mtr
107(b) Average run 8 mtr
108(c) Average run 12 mtr
109Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. painting the MS box and mending good the damages to original finish (a) On Board
110Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch [Approved make] on sheetmetal switch board embedded in wall incl. S & F150x 100x 65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/ perspex cover and making necessary connections as required
111Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/ perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
112Supply & Fixing 240 V, 6A plug socket (Brand approvedby EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
113Supply & Fixing 240 V, 25 A, Modular type starter [Approved make] with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
114Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket [Approved make], without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
115Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator [Approved make] & necy. Connections.
116Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board
117Supplying & Fixing 240 V AC Buzzer (Ancho) on HW boardincl. S&F HW board
118Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long By TATA-Medium GI pipe
119Extra for providing masonery enclosure on the top of the earth electrode of overall @ {Schedule Page no G-2 item no 3 (a)} 2017}
120Extra for treatment of soil by using salt & charcoal or coke for plate electrode
121Excavation of soil for installation of Earth Electrode and filling & ramming. For For Morrum Soil
122Connecting the equipments GI pipe to earth busbar including S & F10 SWG. GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
123Connecting the equipments to earth busbar including S & F 14 SWG. GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
124Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
125Fixing only single/twin fluorescent light fitting suspended 25 cmbellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG)supports fixed with “L” type MS clamp whose one side fixed onceiling with sutable size 4 nos. fastener and other side connectedwith the conduit with suitable size of bolts and nuts incl. S&F EIconduit, “L” type (125mmx125mm) 6mm thick and 25mm with MSclamps and connecting the length of PVC insulated wire andmending good damages to original finish and painting etc. by2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
126Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
127Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required
128Fixing only bulk head ceiling fitting on wall /ceiling by screws etc.
129Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
130Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
131Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter 45 cm (18\\")
132Fixing only louver shutter/cowl on wall with necy. bolts & nuts (6 mm dia x 62 mm long) 45 cm (18\\")
133Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
134SUPPLY OF FITTINGS LIGHT and FAN FIRE EXTINGUISHER:Supplying & fixing 2x20W T8 LED light with Batten fixture. CROMPTON MAKE LED Batten (IGP162 LT8-162xT8) & LED Aluminium 20W T8 tube (LGT8-20-865-2) or equivqlent model of PHILIPS /BAJAJ / HAVELLS as per direction of EIC.
135Supplying & fixing Centura Neo LED Flood Light 50 W 6500 K IP66 LED Flood light suitable for industrial area lighting.HAVELLS MAKE (LHEECNP7PB6J050) or equivqlent model of PHILIPS /BAJAJ / CROMPTON as per direction of EIC.
136Supplying & fixing 10W LED Bulkhead light fixture.CROMPTON MAKE (CIS-306-10-57-SL-DP-NBK) or equivqlent model of PHILIPS /BAJAJ / HAVELLS as per direction of EIC.
137Supplying & fixing Superb Street Light 50 W 6500 K IP65 LED Street Light. HAVELLS MAKE (LHETAVU7PA7J050) or equivqlent model of PHILIPS /BAJAJ /CROMPTON as per direction of EIC.
138Supplying & fixing 400MM sweep Wall Fan (cabin fan). HAVELLS MAKE (FHWSW4SIVR16) or equivqlent model ORIENT/ CROMPTON/USHA as per direction of EIC.
139Supplying & fixing 450MM sweep Exhaust Fan. HAVELLS MAKE (FHEHDSPGRY18) or equivqlent model ORIENT/ CROMPTON/USHA as per direction of EIC.
140Supply,, Installation, Testing & Commissioning of 4.5Kg ISI marked carbon – di – oxide (CO2) fire extinguisher consisting of welded MS cylindrical body, squeeze, lever discharge valve, fitted with internal discharge tube, high pressure discharge hose, discharge nozzle, suspension bracket.
141Supply,, Installation, Testing & Commissioning of 6.0Kg ISI marked ABC Dry powder extinguisher (Stored Presser Type) consisting of welded MS cylindrical body, squeeze, lever discharge valve, fitted with internal discharge tube, high pressure discharge hose, discharge nozzle, suspension bracket.
142Supply of following size L.T. cable, working voltage 1.1 KV grade, unarmoured, screened, stranded, CU distribution power conductor cable. Make: (Finolex/Polycab/Gloster/RRKABEL/KEI) or equivalent make 3C 2.5sqmm Copper Cable (Unarmoured)
143Add 18% G.S.T. + 1% L.W.Cess Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57336305
AUTHORITY Cooperative
TENDER VALUE 28.53 Lakhs
LAST DATE 19-09-2026
Authority
Authority Name West Bengal State Cooperative Marketing Federation Limited
Work Description Tender for Construction Of Construction Of Work Shed For Shgs At Kulgachi Skus Ltd.,Block-Balagarh, Dist.- Hooghly,Under Pm-Rkvy 2026-27 .
Basic Detail
Tender No SCMF/MD/ENG/NIT-12/2026-27 Dated 03.09.2026
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 03 Sep 2026
Submission Date 19 Sep 2026
Open Date 21 Sep 2026
Finance
Tender Value 28.53 Lakhs
Tender Fee Ref. Documents
EMD 57060
Exemption Available
Document List
23be54db-c017-4f9f-a615-51c756bf065d.html
BOQ_2555277.xls
Tendernotice_1 (37).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Sep 21, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

23be54db-c017-4f9f-a615-51c756bf065d.html

xls

BOQ_2555277.xls

pdf

Tendernotice_1 (37).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders