Housing Urban and Rular Development Local Bodies Closing in 4 days TDR #57336045

Tender For Modernisation Of Auditorium At Traffic Police Lines , Sector 29, Chandigarh (Composite Work)

Issued by Local Bodies · Chandigarh, Chandigarh
Tender Value
2.58 Crore
Estimated cost
Bid Submission
11 Sep 2026
4 days left
EMD
5.17 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chandigarh → Chandigarh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Modernisation Of Auditorium At Traffic Police Lines , Sector 29, Chandigarh (Composite Work)

BOQ

Name of Work:- MODERNISATION OF AUDITORIUM AT TRAFFIC POLICE LINES , SECTOR 29, CHANDIGARH (COMPOSITE WORK)
Sl. No. Item Description
1Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size). (As per DSR 5.3)
2Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers (As per DSR 5.9.5)
3Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars (As per DSR 5.22A.6)
4Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) (As per DSR 6.4.1)
5Providing and laying flamed finish granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawing with 18mm th. Stone slab over 20mm (average) thickness of cement mortar 1:4 (1 cement : 4 coarse sand ) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-charge. Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (As per DSR 11.55.1)
6Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood (As per DSR 9.1.2)
7Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.MAKE-DORMA,ASSA ABLO ,D-LINE. (As per DSR 9.21.1)
8Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (As per DSR 10.28)
9Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade. (As per DSR 8.31)
1012 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) (As per DSR 13.1.1)
11Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar (As per DSR 15.7.4)
12Providing and fixing dressing counters 2'-0\\" wide made with 19 mm thick ISI marked commercial board in horizontal along with cabinet. The cabinet size 1'-3\\"X6\\" having 1 no. drawer . The cabinet having 2no's vertical supports of 2'-11\\" height and 1no's horizontal shelve of 19mm board fixed at 4\\" above floor level and the back shall be covered with 6mm thick commercial ply. . The 19mm commercial board shutter shall be fixed with piano hinges to the cabinet below the drawer portion. The whole counter shall be finished with 1 mm. thick laminate mica of approved make / colour except the nozing of counter shall be provided with half round teak wood gola. The inner sides shall be fixed with 0.8mm th. laminate complete in all respect to the entire satisfaction of the Engineer In-charge. (N.S.)
13Providing and fixing 5 mm thick looking mirror3'-6\\" high of approved quality on wall above counter which shall be fixed on 12mm thick commercial ply with approved quality adhesive. The ply shall be properly nailed and screwed on frame having grid of hollock wood battens of size 3\\"x1½” shall be 2'-0\\" c/c apart on both ways. The frame with ply and glass shall be completly fixed to the wall surface with the help of nails and gutties as per consultant drawing complete in all respect to the entire satisfaction of Engineer-in-Charge. (N.S.)
14Providing and applying special paint of oikos make ( Mother of pearl/ otticento/ stucco finish) of approved quality on walls to give even finish with proper base treatment with two or more coats whereever necessary to provide complete to the entire specification of the Engineer Incharge. (N.S.)
15Jupiter Mid Back Mb-PU Top Arms - Chemical Bolts The seat shall be made of Polyurethane Foam moulded with 1.5 ±0.1cm. thk. plywood insert and shall be upholstered with fabric. Approx. Seat Size shall be: Depth: 42.0cm, Width @ rear: 44.0cm. Width @ front: 41.0cm. The back assembly shall be flexing type and made of Polyurethane Foam moulded with MS. tubular frame insert and shall be upholstered with fabric and back cover. The insert shall be made of 01.9 ±0.02cm x 0.16 ±0.0.128cm. thk.MS tubular frame with flexible nylon straps running across the length and width of the frame. Approx; Back-Size shall be: Height: 65.5cm, Width @ top: 34.5cm.Width @ seat level: 46.0cm. The HR polyurethane foam shall be moulded with density = 45 +/-2 kg/m3. The back cover and mechanism cover shall be vacuum formed from black ABS sheets. The Armrest understructure shall be upholstered PU foam moulded with MS insert. Arm tops shall be made of black Integral Skin polyurethane with 50-70 Shore 'A' Hardness & reinforced with wooden insert. Armrest width= 7.0 ±0.5cm and shall be offered as common/individual armrest between chairs. • MS black powder coated (DFT 40-60 microns ) understructure with integrated, auto tip-up mechanism which folds the seat when not in use. • Footprint area of base plate shall be made of HR steel15.0 ±0.2cm X 22.0 ±0.2cm X 0.5 ± 0.05 cm thick. • Backrest supporting beam width shall be-46.0 ±0.2cm.(L) x 8.0 ±0.03cm. x 4.0 ±0.03cm. x 0.2 ±00.16cm MS tube. • Understructure fixed to ground by anchors with washer and nut. The auditorium chair shall be designed to get mounted /grouted on floors with flooring specification as mentioned in flooring pre-requisite . Make Godrej, Geeken, Space wood or equivalent (N.S.)
16The seat shall be made up of 1.2+/-0.1cm thick hot pressed plywood and upholstered with fabric or synthetic leather and moulded polyurethane foam. The back shall be made up 1.2+/-0.1cm thick hot pressed plywood upholstered with replaceable fabric or synthetic leather upholstery covers and moulded polyurethane foam. The moulded polyurethane foam shall be of density 45+/-2kg/m ³, and hardness load 16+/-2kgf as per IS:7888 for 25% compression. The dimensions of seat shall be- 51.0cm(W) x 48.0cm(D) and of back shall be 48.0cm(W) x 76.0cm(H). The armrest top shall be made of moulded polyurethane and mounted on to a drop lift height adjustable type M.S tubular armrest support chrome plated. The armrest height shall be adjustable up to 6.5+/-0.5cm in 5 steps and also has swivel adjustment of 22 degree+/-2 on both sides. The mechanism of the chair shall have following features : 360⁰ revolving type, Knee tilt synchro mechanism, Tilt tension adjustment, Single point control, 4 position locking with anti shock feature, Seat depth adjustment of 6.0+/-0.5cm should be locked in 6 positions. The backrest shall consists of a sliding up down mechanism, Which can be adjusted in the range of 7.5+/-0.5cm and should be locked in 4 positions for correct position of lumber support. The chair shall be provided with pneumatic height adjustment which shall have stroke of 9.0 +/- 0.3 cm. The pedestial shall be fabricated from 0.2+/-0.02cm thick HR sheet, chrome plated and assembled with injection moulded black polypropylene hub cap. The size of the pedestal shall be 66.0+/- 0.5 cm pitch-centre-dia (76.0 +/- 1.0 cm with castors). The twin wheel castors shall be made black nylon. Overall dimensions of Chair shall be, Width of Chair - 76.0cm, Depth of Chair - 76.0cm as measured from pedestal below. Height from ground - min 101.5 to max 117.5cm. Seat height - min 46.5 to max 55.5cm. Dimensions tolerance / variations shall be within +/- 1 cm. Make Godrej, Geeken, Spacewood or equivalent (N.S.)
17Providing and fixing Make in India 100% Dull Nylon Cut Pile, Chromojet Printed roll Carpet, Height 9 mm. (± 1 mm.), Total Height 11 mm. (± 1 mm.), Stitch /10 cm 53-55(± 2 mm.), Pile Weight 1300 GSM (± 5%), Total Weight 2491 GSM (± 5%), Secondary Backing PP Mesh, Gauge 1/8 Cut Pile, Latex Natural Rubber, Color fastness to Light Test Method : AATCC 16 (20 AFU) ≥ 4.0 at 80 Hours, Static Electricity Test Method : AATCC 134 Less than 3.5 KV, Hexapod test Method : ASTM D 5252 ≥ 4, Flammability (Radiant Panel) Test Method : ASTM E 648 ≥ 0.45 (Class I), Product should carry 5 years of warranty. Carpet.Complete in all respect to the entire satisfaction of Engineer-in-Charge. Make Welspun Flooring,Miliken,Kronotex or equivalent (N.S.)
18Providing and fixing of Wooden floor on stage shall have Vapour Barrier of 0.2 mm polyethylene sheet which laid over one coat of approved quality bitumen @ 0.65kg/sqm of grade 85-100. The Resilient Pads/Cushion pads of size 10 mm X 57 mm X 76 mm and sleepers of size 38 mm x 64 mm x 1.22 M Pine laid over the polythylene sheet having 5 pads attached nominally at 305 mm center to center and dip-treated with WOODLIFE-3 preservative. The 20 mm thick Hard Maple flooring TGEM, MFMA Grade marked and stamped Amasa shall be fixed with MI. Fasteners 51 mm barbed cleats or coated staples to sleepers as per complete in all respect to the entire satisfaction of Engineer-in-Charge. Make -Conners ,Tarkett,Rebound ace or equivalent (N.S.)
19Providing and supplying ‘Optra Acoustical Wall Paneling’ with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for Fire reaction Class B-s1, d1 as per EN13501, fabric with an option of colors Peanut, Sesame, Husk as per the choice of the Architect of size 600X600, 600X1200, 600X1800 , and 600X2100mm providing a minimum sound absorption level of 0.85 NRC to be affixed to wall using Wall panel impalers and construction adhesives as per the instructions laid down by the manufacturer. INSTALLATION: 4nos.wall panel Impalers of shall be fixed to the wall surface using self tapping screws. Silica based construction adhesive to be dabbed on to the projecting elements (spikes) of the impalers. Armstrong Optra wall panels shall be pierced through the spikes of the impalers ensuring the line and level of the panels are maintained. Equivalent to Armstrong,Saint Gobain,Installation to be carried out by Trained Installation team Complete in all respect to the entire satisfaction of Engineer-in-Charge.Make -Armstrong,Saint Gobain or equivalent. (N.S.)
20Providing and Fixing Channeled Woodworks perforated panels of width 192mm, thickness of 15mm and length 2400 mm or as required by the Architect/ approving engineer, made of a Moisture Resistant fibre board with minimum 595 Kg/M3 density substrate with a laminated facing as per the approved shade & finish and a melamine balancing layer on the reverse side, with Fire Rating of Class 2 as per BS 476- pt7. The boards shall have a special perforation pattern where the visible surface has a “Helmholtz” fluted perforation of 3mm width and 13mm of visible panel each. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of 0.59. The panels shall be mounted on special aluminum splines (keel) using clips and to the complete satisfaction of the Architect/ Engineer-in-Charge. Make: Equivalent to Armstrong,Siant Gobain INSTALLATION: Install wooden battens (provided by others) of section 50x50mm or as approved by the Architect on the solid wall horizontally using screws and plugs at spacing of 600mm centre-to-centre. Screw the aluminium extruded keel for channelled woodworks over the lowest and second wooden batten at an on-centre distance of 600mm. Install the Skirting (provided by others) of width 50mm or more as required by the Architect/ Engineer-in-Charge and insert the tongue end of the panel in the skirting. Place the inside clip on the groove end of the panel along the Al keel and then place the tongue end of the next panel. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing inside clips into the next keel till the actual height is achieved. Finish off the edges using wooden moulding of matching colour (provided by others).Make -Armstrong,Saint Gobain or equivalent (N.S.)
21Providing and fixing Wooden paneling with 1 mm th. laminate finish (vrb collection shade vrb 5428 trusted oak) on 9mm waterproof ply of greenlam ,merino, greenply or equivalent make fixed to 1 1/2\\"x2\\" partial wood battens on both side fixed (i.e. horizontal and vertical) in brick wall with the help of rawl plug/ gutties and screws/nails, to the satisfaction of consultant /engineer in charge. Make greenlam or equivalent. (N.S.)
22Providing & fixing 6mm th. lacquered glass in solar yellow shade recessed 1\\" behind the surface of paneling ,specified colour of make Saint Gobain/ ASAHI/TATA , fixed with Silicon sealent and with necessary hardware (like screws,studs etc.) if required over existing ply board base .The glass must be properly finished from edges , machine grinded & polished .The groove between glass to glass joint shall be finished with silicon sealant all complete as per direction of Engineer-in-Charge. (N.S.)
23Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System with Perla OP Microlook 90 Edge Tiles With Suprafine15 mmExposed Grid.color white. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9, Light Reflectance ≥85%, Thermal Conductivity k = 0.036 w/m K, Colour White, Fire Performance Euroclass A2-S1, d0,& ISO 5 in accordance to ISO 14644-1 (Zone 4 in accordance to NF S 90-351)in module size of 600 x 600 x 15mm with laminated scrim on the face of the tile, suitable for Green Building application, with Recycled content of 43%. The tile shall be laid on Suprafine 38 with 15 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 12.5Kgs/M2 (as per standard installation layout mentioned below)& pull out strength of minimum 100 Kgs.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of make. The Tile & Grid system used together should carry a 10 year warranty. INSTALLATION:To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications below) at 1200mm maximum. The First/Last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees.Make -Armstrong,Saint Gobain or equivalent Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum. Installation to be carried out by Trained Installation team & Installation should be carried out as per recommended procedure. SUSPENSION SYSTEM accessories consisting of M6 Anchor Fasteners with hanger hole, pre Straightened Hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa, along with Adjustable hook clips of 0.7mm thick, galvanized spring steel for 2.5 mm wire with a minimum pull strength of 110 kg. The adjustable clip also consists of a 4 mm aquiline wire to be used with the main runner.Make -Armstrong,Saint Gobain or equivalent. (N.S.)
24Providing & Fixing of Soft Fibre Acoustical Suspended Ceiling System with OptraBoard Edge Tiles with Prelude 24mmExposedgrid.Color- black. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9, Colour Black, Fire Performance UK Class 0 / Class 1 (BS 476pt - 6 &7) in module size of 1200x1200x25mm, with Recycled content of 66% GW & 74% RW. The tile shall be laid on Prelude 38 with 24mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner and 1200 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15.0 Kgs/M2 (as per standard installation layout mentioned below)& pull out strength of minimum 100 Kgs.. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system. The Tile & Grid system used together should carry a 10 year warranty. INSTALLATION:To comprise main runner spaced at 1200mm securely fixed to the structural soffit using suspension system (specifications below) at 1200mm maximum. The First/Last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum. accessories manufactured and supplied consisting of M6 Anchor Fasteners with hanger hole, pre Straightened Hanger wire of dia – 2.5 mm of 1.80 m length having a tensile strength of 344-413 MPa and a minimum pull strength of 110 kgs. (Adjustable hook clips of 0.7mm thick, galvanized spring steel can also be used for installation purpose as an additional accessory. The adjustable clip also consists of a 4 mm aquiline wire to be used with the main runner).Make -Armstrong,Saint Gobain or equivalent. (N.S.)
25Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineer¬ in-charge and as per manufacturer’s specification, with all 4 sides tapered and backed by acoustical tissue with NRC value not less than 0.60 (As per DSR 12.45.4)
26Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture (As per DSR 13.62.1)
27Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats (As per DSR 13.82.2)
28Providing and fixing of Lighting Bar frame of 2'-0\\" height of 40 NB dia MS pipe of 12 guage having vertical supports of same pipe inside frame at 3'-6\\" center to center welded to outer frame. The complete frame shall have adequate clamps for hanging stage lights, frills and effect lights . The lighting bar shall be ainted out with one coat of zinc chromate primer finally coated with two coats of black quick drying enemal paint as per consultant drawing no.1.103(wall elevation) complete in all respect to the entire satisfaction of Engineer-in-Charge. (N.S.)
29Providing and fixing Pivoted/Revolving partition for side wings 4’-0” wide and 12' high over stage with inner frame consisting of 2 nos. vertical and 8 nos. horizontal members of MS square pipe of size 50x25mm of 16 gauge thick with layer of 6mm ply on both side and layer of glass wool 50mm thick is to be inserted in the gap between ply. Further the complete frame would be covered with heavy quality valvet cloth of dark shade fixed on ply with the help of approved quality adhesive on both sides. The rate shall include the cost of pivoting arrangement at top supported with assembly on existing truss and at bottom floor level with wheels for their free movemnt as per consultant drawing. Complete in all respect as per directions and to the entire satisfaction of the Engineer-in-Charge. (N.S.)
30Providing and fixing mechanical curtain system fixed with the existing space frame at 16’-0” average height by running carbon steel mains strip 16 gauge thick and 90mm wide having two flanges with central box to accommodate the rope and strips for curtain pulleys. This strip has to be given the shape with dyes and jig so that it has the profile on both the flanges of main strip (top as well as bottom), carbon steel clamps of 6mm thick 40mm wide shall be made to run with the help of two rollers on each curtain track. The curtain should also be break press bent and shall have proper arrangement to held both the rollers. The rollers are to be so fixed in the curtain rail so that it has enough space for free movement of the rope. Also the rollers shall groove of sufficient size so as to have the rope run over it and moves easily over it. After providing these rollers, fixed in the curtain strips, an another flat of 40mm width shall be screwed to the curtain strips. This flat shall have hole at the bottom so that the hooks of the curtain can be passed into it and whenever required the same can be removed from there. Further a heavy duty ‘niwar’ to be fixed into the curtain strips so that it keeps the distance between the rollers same when the curtain is closed or will pull all the pulleys when the curtain is opened. The entire track system is to be hanged all along the length from the existing ISLB 150 in the ceiling of the auditorium with the help of 15cms long and 25mmx6mm size MS clamps @ 3’-0” c/c fixed with high tensile bolts. From the side of the section, big brass rollers shall be hanged so that the rope is made to turn through that. All rollers shall be pushed & pulled with master roller clamp with tested quality 3mm thick steel rope shall be used , the winch machine is fitted with variable speed controlled motor of 1 HP of Crompton/Seimen or Heivel complete with control panel with accessories i:e Air breaker contactors 2no's (L& T/ Siemens), 2no's micro switches for auto shop, 3no's push button for forward, reverse and stop position and also hand operated mechanism would be installed to operate the curtain in case of electricity failure. The rates shall further include the cost of gearbox with multiple toothed wheels for movement of steel rope. The work shall be completed in all respects as per directions and to the entire satisfacation of the Engineer-in-Charge. For Front curtain including hand operated handle in case of power failure excluding cost of curtain but including the cost of remote system. (N.S.)
31For Middle curtain including hand operated handle in case of power failure excluding cost of curtain but including the cost of remote system. (N.S.)
32For Rear curtain including hand operated handle in case of power failure excluding cost of curtain but including the cost of remote system. (N.S.)
33Providing and fixing of Frills in front, middle & rear at stage shall be made from double gattering glazed cotton dark shade cloth shall be installed above the stage at appropriate height with 25mm GI pipe having arrangements for their adjustable at position according to the stage director’s instructions as per consultant drawing no. complete in all respect to the entire satisfaction of Engineer-in-Charge. (N.S.)
34Providing and fixing motorized winch operated suspension sets 3.50kgs capacity. The 5lines block winch unit shall have handle and ratched, clew plate and steel wire rope, winch pulling etc. for lightening bars, scenery sets and front masking frills etc. including carriage of material upto all leads and lifts complete in all respect to the entire satisfaction of Engineer-in-Charge. (N.S.)
35Providing and fixing of accoustic double & single panneled doors with splayed joint in center for entry in auditorium by providing 19mm thick commercial ply on either side fixed on wooden frame of 2nd class teak wood battens of size 1\\"x1\\" having grid @ 2'c/c on both sides duly filled with 25mm thick glass wool completely packed and fixing of 1mm thick laminate finish of Greenlam,merino,greenply Make or equivalent( VRB collection Shade VRB 5428) Trusted oak with 6mm groove is to be fixed on all outer exposed sides with approved adhesive and provision is also made for fixing of accoustical door frame with existing door chowkhat with the help of 4no's SS hinges of size 8\\" on both sides panel and also includes the cost of all hardware material of Stainless steel i.e. locking arrangemnt, sliding bolts, floor springs, tower bolts and handles as per consultant drawing no. complete in all respect to the entire satsfaction of Engineer-in charge. (N.S.)
36Providing and fixing Teak wood gola of size 85mmx70mm in polyurethene finish polish provided at edging of stage flooring and front wall of stage panelling of entire width of stage with the help of approved quality adhesive, headless screw/ nails as per consultant drawing no. 1.104 (flooring plan) complete in all respect to the entire satisfaction of Engineer-in-Charge. (N.S.)
37Roller Blinds(Blackout Series) in Auditorium , Roller Blinds(Blackout Series) in Auditorium Providing and fixing Roller blinds of Vista/Dawn and Dusk ( Blackout Series) with following specifications:- Fabric Specification: Style Opaque Fiberglass Construction 4 ply lamination (3 ply vinyl and 1 ply fiberglass) (each vinyl is equal thickness and weight) Thread count 60 threads per square inch (23 per square centimeter) Thickness 0.32 millimeters (+ .05mm) Weight per square yard 12.5 ounces (+ 2.0) (424 grams/sq mt) (+/-68gms) Flammability Meets or exceeds National Fire Protection Association Standard NFPA 701 Test Method 1- 2004 Edition (Small Scale) (Based on 12oz Opaque/ Duplex test) Wash ability Material may be dusted with a damp cloth. When scrubbing is necessary, warm water, mild detergents and gentle rubbing are recommended. Opacity The fabric will not admit light. Meets or exceeds most other CCC-C-521E Type2 specifications in all respects.Complete in all respect to the entire satisfaction of Engineer-in-Charge. (N.S.)
38Providing and fixing of Blackout Film of Make -Garware,3M or equivalent Film on slits of Auditorium complete in all respect to the entire satisfaction of Engineer-in-Charge. (N.S.)
39Roller Blinds in Projection Room Roller Blinds in Projection Room Providing and fixing Vista /Dawn and Dusk Roller blinds Translucent as per following Fabric specifications:- Style Translucent Fiberglass Construction 3 ply lamination (2 ply vinyl and 1 ply fiberglass) (each vinyl is equal thickness and weight) Thread count 60 threads per square inch (23 per square centimeter Thickness 0.25 millimeters (+/- 0.05mm) Weight per square yard 9.6 ounces (+/ -2.0) 325 grams/sq mt (+ or - 68) Flammability Meets or exceeds National Fire Protection Association Standard NFPA 701(Small Scale) Complete in all respect to the entire satisfaction of Engineer-in-Charge. (N.S.)
40Providing and fixing of Reflective Film of Make-Garware,3M or equivalent (N.S.)
41Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (As per DSR 11.41.2)
42Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment or grouting of joints to be made separately). Size of Tile 600x600 mm (As per DSR 11.47.2)
43Providing and fixing 6mm thick clear tempered glass of ( enhance aura )ASAHI,Saint Gobain or equivalent make with VLT vlaue 63% , internal reflection 21% , external reflection 25% , with SF Value 58% , SC Value 0.67 and U value 5.4 W/ square meter K, in aluminium window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (N.S.)
44Providing and Fixing factory made uPVC white colour casement/sliding window / door, made of extruded profiles. Profiles of frames and sash will be mitered cut and fusion welded at all corners, including drilling of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 ± 0.2 mm thick galvanized steel profile to e inserted in required profile, frame will be fixed to the wall with 8 mm x 100 mm long fasteners, with glazing, harware, hinges & fittings all complete as per direction of Engineer-in- charge. in projection room (N.S.)
45Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (As per DSR 13.91)
46Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work (As per DSR 13.99.1)
47Providing and fixing heavy quality valvet cloth of approved shade and color for curtains in the existing hooks with back lining including stitching and making required pleats complete drapped to half of full width operated from control panel with control switches. The rate also includes the cost of fixing jute \\"Niwar\\" for receving the curtain hooks and hanging the curtain in position as per consultant complete in all respect to the entire satisfaction of engineer-in-charge. (N.S.)
48HARDWARE DORMA 278a,D-LINE or equivalent with 55mm backset, 20mm square forend prepared for euro profile cylinder including strike plate. and EPC 60mm Length both side key operation & Escutcheons in SSS Finish (N.S.)
49DORMA 4014 ,D-LINE or equivalent Wall mounted door stop with coat hook in SSS finish (N.S.)
50DORMA or equivalent floor stop half dome with 45mm dia with fixing accessories, in satin Chrome (N.S.)
51DORMA 4012 ,D-LINE or Equivalent wall mounted door stop dome in SSS finish with 60mm length with fixing accessories (N.S.)
52Pure 8100 Type 1 Package with Pair of Pure 8100 Design Lever Handle on Roses & escutcheons. Including 271a Sash lock with 72mm CTC, 55mm Backset 20mm Square forend. EPC 60mm length both side key operation. Finish: Satin stainless steel (N.S.)
53Pure 8100 Type 3 Package with Pair of Pure 8100 WC Design Lever Handle on Roses & escutcheons 7122. Including 275a WC lock with 78mm CTC, 55mm Backset 20mm Square forend. Finish: Satin stainless steel (N.S.)
54Female sign plate 3030-F for WC application with fixing screws size 125 x 125mm, rounded corners in SS 304 satin stainless steel finish. Marking in black (N.S.)
55Male sign plate 3020-M for WC application with fixing screws size 125 x 125mm, rounded corners in SS 304 satin stainless steel finish. Marking in black (N.S.)
56DORMA,D-LINE or Equivalent -Pull Handle TGDI-H 450 back to back with 350mm CTC, adjustable fixing for glass, wood and metal doors in satin stainless steel. The pull handles should have supporting washer with raised bevelling on the outer surface. Length =450mm, 25mm dia, -SS304 (N.S.)
57DORMA,D-LINE or Equivalent-Pull Handle TGDI-D 300 back to back with adjustable fixing for glass, wood and metal doors in satin stainless steel. The pull handles should have supporting washer with raised bevelling on the outer surface. Length =300mm, 22mm dia, -SS304 (N.S.)
58Plus 8100 Type 2 Package with Pair of Plus 8100 Design Lever Handle on Roses & escutcheons. Including 281a Sash lock with 72mm CTC, 55mm Backset 20mm Square forend. EPC 60mm length one side key other side thumb turn operation. Finish: Satin stainless steel (N.S.)
59Standard Top Pivot. Finish: Satin stainless steel (N.S.)
60DORMA, D-LINE or Equivalent rack and pinion door closer TS 72 EN size 2-4, with std. arm and with two independent closing valves and latching speed adjustable by arm. All adjustment screws face fixed. Silver finish. As per EN 1154. (N.S.)
61DORMA, D-LINE or Equivalent Parallel arm bracket suitable for TS 83/ TS 73V. Silver finish (N.S.)
62DORMA, D-LINE or Equivalent rack and pinion door closer TS 83 EN size 3-6, with back check and standard arm with two independent closing valves and latching speed adjustable by arm. All adjustment screws face fixed with slide plate. Silver finish. As per EN 1154 and CE marked. (N.S.)
63DORMA, D-LINE or Equivalent rack and pinion door closer TS 68 EN size 3, with std. arm and with two independent closing valves and latching speed adjustable by arm. Silver finish. As per EN 1154. (N.S.)
64Standard Lock US 10 with Strike plate & EPC. Finish: Satin stainless steel. Make-Dorma, D-LINE or equivalent. (N.S.)
65Providing and fixing Automatic Sliding glass door operator for max door weight of 2 x 100 kgs , Make: DORMA,D-LINE or Equivalent ES 200 Easy or equivalent , compliant with future European standards and produced according to the guidelines for power-operated windows, doors and gates, BGR 232, the UVV and the VDE regulations With EM Lock . TÜV design tested, tested according to the low voltage guidelines, fulfils DIN 18650 standards, for framed glass door application with 12mm tougned glass for 2 Nos sliding door panels and 2 Nos fixed panels, both sliding Operator & Frame Finish should be Silver Anodised E6/C0, with operator dimensions (H x D) : 100 x 180 mm and of length as required to suit the opening size given below. The track profile should be separate from the main profile for enabling reduction in vibration insulation. Microprocessor-controlled control unit, Self-learning, with adjustable parameters for opening and closing speed, hold-open time and opening and closing force, reversing when obstruction is encountered, Class of protection IP 20. Activators- DORMA Eagle 6 Safe Combinations Radars with Motion & Presence Detection (02 Nos), Light barrier comprising of receiver and transmitter - 01 Pair, with Electro-mechanical locking, Program Switch with Key. Max Panel Weight Carrying Capacity of 2 X 100 Kgs. tem shall have constant power supply 230V+ 5%, 50Hz, AC . The requirement in total is as mentioned , .The above work should complete in all respect as per approved drawings and to the best satisfaction of Architect /Engineer-in-Charge. Make-Dorma, D-Line or equivalent (N.S.)
66Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (As per DSR 11.37A)
67Providing and fixing 18 mm thick gang saw cut, mirror polished,premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm (As per DSR 8.2.2.2)
68Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre (As per DSR 13.41.1)
69Canopy shade Structure Providing Design, Detailed Engineering, Fabrication, Supply, Erection and Installation of Primary Steel Structure Work in Mild Steel built up tubular SHS / CHS / RHS Section including cutting, hoisting, welding,fixing in position. Applying a Two Coat of Duco Paint over one coat of Anti Oxide Duco Primer after Rust Cleaning Process. Providing Design and Fixing imported tensile fabric of weight not less than 650 GSM Fabric, Make Architectonic Belgium .This Should also include cutting, welding and cables, Plates and necessary hardware form fixing the fabric as approved shape as per drawing, Membrane shall be cut and manufactured with High frequency PVC Welding Machine. Canopy shade Structure: 48 x 29 feet .Complete in all respect to the entire satisfaction of Engineer-in-Charge. (N.S.)
70Providing and fixing auditorium seats with on armrest after every 4 seats .the fixed sears shall be constructed with 19mm thick plywood and teak wood battens as per detailed drawings and the back shall have 3'' thick foam covering the wooden frame the seats shall be finished with fabric of approved make and shade with teak wood lipping duly malamine polished /duco painted the seat shall be anchored to the base concrete with suitable chemical grouting /dash fastners ,complete in all respect to the best satisfaction of the engineer-in-charge (N.S.)
71Providing of Access Panel 600mmX600mm Moisture Resistant Gypsum Board Access Panel with Powder coated Aluminium framing & stiffners, push -catch closing mechanism with door retaining safety cable and hook, concealed locking arrangement Trap door frame having Knauf Danoline embossed marking. {Fixing Details - Single layer of 12.5 mm tapered edge frame is then screw fixed to ceiling section with 25 mm dry wall screws at 230 mm centers. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. The work shall also include jointing and fixing to a flush finish of tapered edges of Gypsum board with recommended filler, paper tapes and two coats of putty/primer suitable for gypsum board to achieve a smooth finish as per manufacture's specifications. Make- Knauf Danoline,VOGL or Equivalent (N.S.)
72Providing and fixing Corian stone Make- Granex-Stylam,Rehau,Dupond with special adhesives on door elements, edges to be round and smooth complete in all respect as per Direction of Engineer-in-Charge (N.S)
73PUBLIC HEALTH PORTION Supply, installation, testing and commissioning of Air cooled scroll type Chilling machine each having a capacity of 24 TR (nominal capacity) suitable for operation on refrigerant R-407/410 each comprising of the following complete as per specifications and as required. Multiple Scroll type compressor complete with automatic capacity control safety switches, forced feed lubrication system etc. as per specifications, Suitable capacity squirrel cage induction motor with class 'B' insulation suitable for operation on 415 +- 10% volts, 50Hz, A.C. supply. Starter suitable for compressor motor complete with ammeter with CTs, over load protection, under voltage protection, protection against phase reversal & independent single phase preventers etc complete as required. Matching capacity shell and tube type Evaporator. Lubrication device consisting of automatic electric oil pump, oil cooler, head tank, oil strainer, and automatic pressure regulating valve, oil heater, oil heater thermal switch etc. as per specifications. Matching air cooled condenser of Copper tubes and aluminium fins. Refrigerant piping fittings, valves and accessories to inter connect compressor, condenser, chiller and expansion valve. Microprocessor based control panel complete with accessories as per specifications, Refrigerant line accessories comprising of safety valves, angle valve, liquid line indications, liquid level control etc. Suction line insulation with minimum 19 mm thick polyvinyl nitrile rubber insulation complete as required. Frame work for mounting the above condenser, compressor and motor with base plate complete with anti-vibration pads/springs. Initial/first charge of refrigerant gas & compressor oil, RCC / cement concrete foundation for the unit as per OEM recommendation. (NSR)
74Supply, Installation, testing and commissioning of factory built vertical floor mounted Chilled water double skin type air handling units made of 46 mm thick panels consisting of G.I. Casing of thickness 0.6 mm outside layer 0.6 mm thickness inside layer with polyurethane foam (PUF) insulation of density not less than 38 Kg/Cum factory injected between them by injection molding machine complete with 6 row deep cooling coil with aluminum finned copper tubes, filter sections with 50 mm thick metal washable synthetic type air pre-filters, belt drive package with TEFC drive motor suitable for 415+ 10% volts, 50 HZ, 3 Phase, A.C. supply, drain connections, stainless steel drain pan, necessary vibration isolation arrangement, foundations, etc. complete as per specifications and of following capacities. The AHU shall be capable of Delivering 8000 CFM at 40 mm static (minimum 35 mm external static), capacity 20 TR, with Pre filters section, cooling coil, forward curved blower. The cost of distributers shall be part of the AHU. All coils for Air handling units shall be 120% capacity of the capacity indicated. Additional rows if required shall be provided at no extra cost Including cost for foundations. (NSR)
75Supply, installation, testing and commissioning of cooling / heating thermostats (Proportional thermostats) for various Air Handling Units as per specifications including all accessories, mountings, wiring between thermostat & unit, terminations etc., complete in all respect as required and as per specifications. (NSR)
76Supply, installation, testing and commissioning of Humidistat for various Air Handling Units as per specifications including all accessories, mountings, wiring between Humidistat & unit, terminations etc., complete in all respect as required and as per specifications. (NSR)
77Chilled Water Pumps comprising of the following complete as per specifications and as required. Supplying, Installation, testing and commissioning of CENTRIFUGAL END SUCTION MONOBLOC PUMP SETS, factory mounted on a common base with electric motor for recirculation of water for the central air conditioning system. Pumps shall be single stage, back pull out design to allow removal and service of the entire rotating assembly without disturbing the pump casing & piping. All pumps shall be provided with mechanical seal and pump shaft shall be integrated with coupling by means of friction welding and make up a completely stable and rigid mechanical unit. The pump motor shall be suitable for 415 + 10% volts, 50 cycles, 3 phase power supply. The quoted price shall include cost of thermal insulation, cladding and cowl over pump to protect from weather for chilled water pumps. Monobloc pump. Suitable HP, TEFC squirrel cage induction motor with class 'F' insulation, 2900 rpm, operating on 415 +/- 10% volts, 3 phase, 50 Hz A.C. supply. Expended Polystyrene (TF quantity) insulation not less than 50mm thick duly cladded between aluminum sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections as per specifications. Mounting frame with Anti vibration pads. RCC/cement concrete foundation for the pump unit. Operating parameters Water flow rate = 116 USGPM Head = 98 Ft. of water (30 meter) Motor HP = 5 (Suggested) Quantity indicated includes one standby
78Supply, installation, testing and commissioning of heater batteries of following capacities. 15 KW (NSR)
79Supply, installation, testing and commissioning of 3-way motorized valves suitable for Chilled water as well as hot water application complete with Electrical / Electronic actuator, necessary wiring and required accessories for proper operation and control of valves of following sizes 50mm dia (3-way valve) (NSR)
80Supplying, installation, testing and commissioning of M.S. expansion tank of size 1m x 1m x 1 height made of 3mm thick mild steel sheet complete with 50mm thick expanded polystyrene (TF quality) insulation covered with vapour barrier, 0.5mm x 20m GI wire mesh netting and finished with 0.5mm thick GI cladding duly plastered and complete with vent and drain connections with float valve, quick fill and control valves etc. as required including cost of foundation. The expansion tank will be installed atleast 600 mm above the highest point of piping circuit. Piping and Valves (NSR)
81INSULATED CHILLED WATER PIPING WITH NITRILE RUBBER INSULATION Supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 Kg / cu m density, thermal conductivity 0.037 W/MK or better at 20 deg mean temperature class 'O' insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect. Note:- The Pipes of sizes 150mm & below shall be M.S. 'C' class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 80 mm dia. ( 32 mm th. Insulation ) (As per DSR 16.2.9)
8265 mm dia. ( 32 mm th. Insulation ) (As per DSR 16.2.10)
8350 mm dia. ( 32 mm th. Insulation ) (As per DSR 16.2.11)
84INSULATED VALVES Supplying, fixing, testing and commissioning of following valves, strainers, gauges in the chilled water plumbing duly insulated to the same specifications as the connected piping and adequately supported as per specifications. BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O- Ring PN 16 pressure rating for chilled water/hot Water circulation as specified 80 mm diameter (As per DSR 16.7.1.5)
8565 mm diameter (As per DSR 16.7.1.6)
8650 mm diameter (As per DSR 16.7.1.7)
87BALANCING VALVE WITH BUILT IN MEASURING FACILITY with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled / hot water circulation as specified. 80 mm diameter (As per DSR 16.7.2.5)
8865 mm diameter (As per DSR 16.7.2.6)
8950 mm diameter (As per DSR 16.7.2.7)
90NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating for chilled / hot water circulation including insulation as specified. 65 mm diameter (As per DSR 16.7.3.6)
91Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled / hot water circulation including insulation as specified. 80 mm diameter MS pipes (As per DSR 16.7.4)
9250 mm diameter MS pipes (As per DSR 16.7.4.7)
93Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required (As per DSR 16.8)
94Providing & fixing in position the mercury in glass industrial type thermometers. (As per DSR 16.9)
95Supply installation testing and commissioning of flow switch (NSR)
96Supplying, installation, testing and commissioning of Auto air vents. (NSR)
97Providing and fixing in position the following PVC ( Min 3 mm thick) Heavy duty pipes cut to required lengths and installed with all screwed joints with the necessary elbows, tees and reducers etc duly insulated with 6 mm thick insulationas per specifications. 50mm dia pipes (NSR)
9840mm dia pipes (NSR)
99AIR DISTRIBUTION DUCTING, GRILLS, DIFFUSER AND INSULATION Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet (As per DSR 16.12.1.1)
100Thickness 0.80 mm sheet (As per DSR 16.12.1.2)
101Supply, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet (As per DSR 16.12.2.1)
102Thickness 0.80 mm sheet (As per DSR 16.12.2.2)
103Supply, fabrication, installation and testing the flexible connections constructed of fire resistance flexible double canvas sleeve as per the approved shop drawings. (NSR)
104Supplying, Fixing,testing and commissioning of fire dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Fire damper (As per DSR 16.20.1)
105Actuator (As per DSR 16.20.2)
106Supplying and fixing of Powder coated extruded aluminium Supply Air Grills with aluminium Volume Control Dampers as per specifications. (As per DSR 16.15)
107Supplying and fixing of Powder coated extruded aluminium Return Air Grills with louvers but without aluminium Volume Control Dampers as per specifications. (As per DSR 16.16)
108Supply, installation, testing and balancing of inlet/outlet air louvers with bird screen and volume damper for fresh air in powder coated extruded aluminum construction as per specifications and approved shop drawings. Fixing arrangement including wooden frame for fixing of grill and dampers shall be included in the cost. (NSR)
109INSULATION Supply, installation and testing of acoustic lining with 25 mm thick 32 kg density fibreglass board covered with 28 G perforated aluminium sheet supply air ducts as per the specifications. (NSR)
110Supply and installation of External Thermal insulation 19 mm thick insulation for air ducts on ducts with cross linked nitrile rubber as per the approved specifications . Quoted price shall be inclusive of adhesive, tapes as per specification. (NSR)
111Supply and installation of 50 mm thick acoustic lining on walls of AHU room / Plant room covered with 50 mm thick fibre glass and perforated aluminum sheet as per the approved shop drawings & specifications. (NSR)
112ELECTRICAL MAIN HVAC Panel MCC-1 Designing, fabricating, transporting to site, Installation, testing and commissioning of floor mounted, self supported, compartmentalized LT cubical pattern (Extendable Type) metal clad switch board, fabricated from 2mm (14 G) thick CRCA sheet steel suitable for 31 MVA rupturing capacity at 415 V, 3 phase, 4 wire, 50 HZ AC supply and equipped with PVC sleeved aluminum bus bars of specified rating and following switch gears inter connected by PVC sleeved solid conductors, including 7-tank cleaning, degreasing, phosphating process and treatment of panel with anti-corrosive zinc based primer paint and finally powder coating the panel, complete with earthing terminals, cable and bus bar alleys and hoisting hooks as required. The LT panel will comprise ACBs and MCCBs as described below for incoming and outgoing power supplies. Necessary cable alley, spare switches, internal wiring, control wiring / cabling and earthing of all equipment shall also be included. All starters shall have the following accessories: TPN MPCB as per the suitable rating, terminal block for power distribution, contactor, overload relay with built in single phasing protection, phase indication lights and indicating light for ON/OFF status, ammeter with CTs & selector switches, relay, auto manual selection & push buttons with SP MCB. All internal wiring and GI earthing of air handling unit motors from the panel shall be included. The panel shall include the following accessories. TPN MPCB / MCB for incoming power as per rating given below Terminal block for power distribution. Single phase preventer. Phase indicating lights and indicating light for 'ON' status with toggle switches and back-up fuses. 96 mm x 96mm voltmeter with fuse of suitable range. Ammeter of suitable range with CTs and selector switch. Time delay relay for delayed automatic restart of air handling unit motor. 220/24 volts transformer. Wiring for micro-switch smoke sensor and electric actuator for stopping the fan when smoke/fire damper closes (For AHUs provided with fire damper). Control wiring for thermostat. ON/OFF push buttons with toggle switch for remote start/stop and indicating light for 'ON' status at CONTROL DESK. Bimetallic lugs shall be used at copper to aluminium joints. Auto / Manual start / stop selector switch shall be provided for each equipment in the panel to facilitate remote operation from Central Indication Light Panel. Panels shall have adequate space for mounting transformers and other accessories related to control system. INCOMERS 1 No MCCB as per following details/ specification: 250A, TPN, MCCB with in-built protection such as thermal over load, earth fault, short circuit, auxiliary contacts with door interlock facility & padlock facility shall contain the following: Voltmeter of 0-300A with VSS & one set of (RYB) phase indicating lights with 6A SP MCB Indicating lamps protected by 6A MCB to indicate ON,OFF, TRIP for ACB 0 - 300 Amps 96 x 96 sqmm Ammeter with 800/5 Amps resin cast CT’s and selector switch. Under voltage relay - 1 set BUSBARS : 250 A , TPN Aluminium busbar duly sleeved - 1 set Maximum density of aluminimun bus bars for current carrying capacity shall be one amp per square mm. OUTGOINGS : Chiller Unit- 02 Nos. MCCB's (2W) as per following details/ specifications: 100A, TPN MCCB, motor duty, with extended handle and outgoing feeder to 24 TR starter panel of aircooled chiller unit. The compartment shall contain : (i) \\"ON/OFF\\" LED indicating lamp with 6A control SP MCB (ii) 0 - 125 amps 96 x 96 sq mm ammeter with 500/5 amps CT’s and selector switch. AHU Motors 02 Nos 40 amps TPN MPCBs, with extended handle with 5 HP DOL starters with VFD bypass, over load relays with built in single phasing protection and outgoing feeders to AHU motors. Each of these compartments shall contain CT operated ammeter of 0-63 Amps range with selector switch, auto manual switch along with an ON / OFF indicating lamps and push buttons for status of the pump motors with SP MCB. Chilled water pumps 03 nos 16 amps TPN MPCBs, with extended handle with 2 HP DOL starters, over load relays with built in single phasing protection and outgoing feeders to Pump motors. Each of these compartments shall contain CT operated ammeter of 0-25 Amps range with selector switch, auto manual switch along with an ON / OFF indicating lamps and push buttons for status of the pump motors with SP MCB. Heater Battery-15 kw 02 Nos 63 amps TPN MPCBs, 35 KA, with extended handle, over load relays with built in single phasing protection and outgoing feeders. Each of these compartments shall contain CT operated ammeter of 0-63 Amps range with selector switch, auto manual switch along with an ON / OFF indicating lamps and push buttons for status of the pump motors with SP MCB. Please Enable Macros to View BoQ information
113ELECTRICAL MAIN HVAC Panel MCC-1 Designing, fabricating, transporting to site, Installation, testing and commissioning of floor mounted, self supported, compartmentalized LT cubical pattern (Extendable Type) metal clad switch board, fabricated from 2mm (14 G) thick CRCA sheet steel suitable for 31 MVA rupturing capacity at 415 V, 3 phase, 4 wire, 50 HZ AC supply and equipped with PVC sleeved aluminum bus bars of specified rating and following switch gears inter connected by PVC sleeved solid conductors, including 7-tank cleaning, degreasing, phosphating process and treatment of panel with anti-corrosive zinc based primer paint and finally powder coating the panel, complete with earthing terminals, cable and bus bar alleys and hoisting hooks as required. The LT panel will comprise ACBs and MCCBs as described below for incoming and outgoing power supplies. Necessary cable alley, spare switches, internal wiring, control wiring / cabling and earthing of all equipment shall also be included. All starters shall have the following accessories: TPN MPCB as per the suitable rating, terminal block for power distribution, contactor, overload relay with built in single phasing protection, phase indication lights and indicating light for ON/OFF status, ammeter with CTs & selector switches, relay, auto manual selection & push buttons with SP MCB. All internal wiring and GI earthing of air handling unit motors from the panel shall be included. The panel shall include the following accessories. TPN MPCB / MCB for incoming power as per rating given below Terminal block for power distribution. Single phase preventer. Phase indicating lights and indicating light for 'ON' status with toggle switches and back-up fuses. 96 mm x 96mm voltmeter with fuse of suitable range. Ammeter of suitable range with CTs and selector switch. Time delay relay for delayed automatic restart of air handling unit motor. 220/24 volts transformer. Wiring for micro-switch smoke sensor and electric actuator for stopping the fan when smoke/fire damper closes (For AHUs provided with fire damper). Control wiring for thermostat. ON/OFF push buttons with toggle switch for remote start/stop and indicating light for 'ON' status at CONTROL DESK. Bimetallic lugs shall be used at copper to aluminium joints. Auto / Manual start / stop selector switch shall be provided for each equipment in the panel to facilitate remote operation from Central Indication Light Panel. Panels shall have adequate space for mounting transformers and other accessories related to control system. INCOMERS 1 No MCCB as per following details/ specification: 250A, TPN, MCCB with in-built protection such as thermal over load, earth fault, short circuit, auxiliary contacts with door interlock facility & padlock facility shall contain the following: Voltmeter of 0-300A with VSS & one set of (RYB) phase indicating lights with 6A SP MCB Indicating lamps protected by 6A MCB to indicate ON,OFF, TRIP for ACB 0 - 300 Amps 96 x 96 sqmm Ammeter with 800/5 Amps resin cast CT’s and selector switch. Under voltage relay - 1 set BUSBARS : 250 A , TPN Aluminium busbar duly sleeved - 1 set Maximum density of aluminimun bus bars for current carrying capacity shall be one amp per square mm. OUTGOINGS : Chiller Unit- 02 Nos. MCCB's (2W) as per following details/ specifications: 100A, TPN MCCB, motor duty, with extended handle and outgoing feeder to 24 TR starter panel of aircooled chiller unit. The compartment shall contain : (i) \\"ON/OFF\\" LED indicating lamp with 6A control SP MCB (ii) 0 - 125 amps 96 x 96 sq mm ammeter with 500/5 amps CT’s and selector switch. AHU Motors 02 Nos 40 amps TPN MPCBs, with extended handle with 5 HP DOL starters with VFD bypass, over load relays with built in single phasing protection and outgoing feeders to AHU motors. Each of these compartments shall contain CT operated ammeter of 0-63 Amps range with selector switch, auto manual switch along with an ON / OFF indicating lamps and push buttons for status of the pump motors with SP MCB. Chilled water pumps 03 nos 16 amps TPN MPCBs, with extended handle with 2 HP DOL starters, over load relays with built in single phasing protection and outgoing feeders to Pump motors. Each of these compartments shall contain CT operated ammeter of 0-25 Amps range with selector switch, auto manual switch along with an ON / OFF indicating lamps and push buttons for status of the pump motors with SP MCB. Heater Battery-15 kw 02 Nos 63 amps TPN MPCBs, 35 KA, with extended handle, over load relays with built in single phasing protection and outgoing feeders. Each of these compartments shall contain CT operated ammeter of 0-63 Amps range with selector switch, auto manual switch along with an ON / OFF indicating lamps and push buttons for status of the pump motors with SP MCB. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57336045
AUTHORITY Local Bodies
TENDER VALUE 2.58 Crore
LAST DATE 11-09-2026
Authority
Authority Name Chandigarh Administration Engineering Department
Work Description Tender for Modernisation Of Auditorium At Traffic Police Lines , Sector 29, Chandigarh (Composite Work)
Basic Detail
Tender No CP4/2026/3082329
Bidding Type Tender
Location
City Chandigarh
State Chandigarh
Key Dates
Publish Date 03 Sep 2026
Submission Date 11 Sep 2026
Open Date 11 Sep 2026
Finance
Tender Value 2.58 Crore
Tender Fee Ref. Documents
EMD 5.17 Lakhs
Exemption Not Available
Document List
5e156ddf-ef98-4ca9-bacb-061ebb0a77e6.html
BOQ_116867.xls
Tendernotice_1 (24).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Sep 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 4 days

Tender Documents

Download All (ZIP) ↓
html

5e156ddf-ef98-4ca9-bacb-061ebb0a77e6.html

xls

BOQ_116867.xls

pdf

Tendernotice_1 (24).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail