Tender for Rectification Of Mcc Panel With Other Allied Work At Karisunda Water Supply Scheme (At Cwr Site) Under Bankura Mechanical Division Phe Dte.
BOQ
| Sl. No. | Item Description |
| 1 | Detection of fault, dismantling and removal of burnt-out electrical spares, wires and other damaged components from the Motor Control Panel, including thorough cleaning of the panel and removal of all burnt/damaged materials from inside the panel after proper disconnection and isolation of electrical lines, complete with engagement of skilled electrician and all necessary labour, tools and tackles, as directed by the Engineer-in-Charge (EIC). |
| 2 | Supply and delivery at site of the following accessories as per approved sample, complete with all necessary fittings and accessories, conforming to the required specifications and as approved by the Engineer-in-Charge. Make: ABB/Siemens/Approved make as per PHED Vendor List. |
| 3 | 5 HP DOL STARTER FEEDER – (1 NO.) |
| 4 | 25A TP MPCB, Ie current setting range 6.30 … 10.0 Amp |
| 5 | 25A TP Contactor, 230V AC |
| 6 | 2NO+2NC Aux Block |
| 7 | Microprocessor Based EOCR-SSD-0-30A |
| 8 | Current Transformer, 0-30A, Cl-1.0, VA-10 |
| 9 | 6A DP MCB |
| 10 | Red, Green, Amber Indicating Lamps |
| 11 | Red, Green Pushbutton with NO/NC Element |
| 12 | Digital Ammeter, Single Phase |
| 13 | Ammeter Selector Switch |
| 14 | 16A TP MCB – for Cap Bank Switching |
| 15 | ON Delay Timer, 230V AC |
| 16 | 9A TP Contactor, 230V AC |
| 17 | 2 KVAR Cylindrical Capacitor, 440V AC |
| 18 | OV/U/V Relay |
| 19 | Glass Fuse Terminal Block for OV/UV Protection |
| 20 | 1.5 KW DOL STARTER FEEDER – (1 NO.) – DEWATERING |
| 21 | 20A DP MCB |
| 22 | 18A TP Contactor, 230V AC |
| 23 | 1NO+1NC Aux Block |
| 24 | 6A DP MCB |
| 25 | Red, Green, Amber Indicating Lamps |
| 26 | Red, Green Pushbutton with NO/NC Element |
| 27 | 18.5 KW S/D – STARTER FEEDER – (3 NOS.) |
| 28 | 100A TP Motor Duty MCCB Based (50 KA), with Spreaders, ROM |
| 29 | 63A TP Contactor, 230V AC |
| 30 | 50A TP Contactor, 230V AC |
| 31 | 2NO+2NC Aux Block |
| 32 | 1NO+1NC Aux Block |
| 33 | Microprocessor Based EOCR-3DM2-5-80A |
| 34 | Current Transformer, 0-100A, Cl-1.0, VA-10 |
| 35 | 6A DP MCB |
| 36 | Red, Green, Amber Indicating Lamps |
| 37 | Red, Green Pushbutton with Element |
| 38 | Digital Ammeter, Single Phase |
| 39 | Ammeter Selector Switch |
| 40 | Electronic Star-Delta Timer, 230V AC |
| 41 | 32A TP MCB – for Cap Bank Switching |
| 42 | ON Delay Timer, 230V AC |
| 43 | 7 KVAR Capacitor Duty Contactor, 230V AC |
| 44 | 7 KVAR Cylindrical Capacitor, 440V AC |
| 45 | OV/U/V Relay |
| 46 | Glass Fuse Terminal Block for OV/UV Protection |
| 47 | INCOMER SECTION |
| 48 | 250A TP MCCB (50KA) MP Based O/C, S/C Release with Spreaders, ROM |
| 49 | 200A TPN SDF Unit, with 200A HRC Fuse |
| 50 | R, Y, B Phase Indicating Amps, 230V AC |
| 51 | Digital Ammeter with ASS, 0-250A |
| 52 | Digital Voltmeter with VSS, 0-500V |
| 53 | Current Transformer, 0-250A, Cl-1.0, VA-10 (Resin Cast) |
| 54 | 6A SP MCB |
| 55 | Digital MFM |
| 56 | 1.5 Sq.mm single core FRLSH wire. |
| 57 | 2.5 Sq.mm single core FRLSH wire. |
| 58 | 25 Sq.mm single copper cable. |
| 59 | 16 Sq.mm single copper cable. |
| 60 | Fitting and fixing of the above-supplied materials under Item Nos. 3.00 & 6.12 to the panel, including rewiring of the burnt-out control circuit and power circuit with necessary gauge copper wires, indicating lamps, selector switches, push buttons, power terminals, etc., proper socketing and termination of all leads for proper fitting, complete by engaging skilled electrician as per direction of the Engineer-in-Charge (EIC), including testing of the panel after completion of the repair work with proper safety precautions and rectification of any problem arising during the testing period, as directed by the EIC. |
| 61 | Add: 18% GST |
| 62 | Add: 1% Cess Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 18, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysSep 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender