Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #57334876

Tender For Repairs/Maint Of Lt External Electrification Distribution Network And Connected Accessories At C & E Area Under Ge Chennai

Issued by Statutory Bodies & Commissions/Committees · Chennai, Tamil Nadu
Tender Value
30 Lakhs
Estimated cost
Bid Submission
01 Oct 2026
0 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repairs/Maint Of Lt External Electrification Distribution Network And Connected Accessories At C & E Area Under Ge Chennai

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 24-Sep-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-Oct-2026

BOQ

Name of Work:- Repairs/Maint of LT external electrification distribution network and connected accessories at C & E area under GE Chennai
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE CHENNAI Name of Work: Repairs/Maint of LT external electrification distribution network and connected accessories at C & E area under GE Chennai Contract No: GE/CHE/ OF 2026- 2027 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of item Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words
2Excavation in trenches not exceeding 1.5m in width and 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed.
3Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm complete all as specified and as directed.
4Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
5Supply and lay fine sieved excavated dry soil cushioning spreading levelling for cable trenches complete all as specified and directed. (Note: Punned thickness only shall be measured and paid.)
6Supply and laying well burnt bricks sub class 'B' in trenches for cable protection of U/G cable complete all as specified and directed.
7DWC (Double wall corrugated) pipe 50 x 38 mm conforming to IS: 14930/ IS 16205 for protection of electric cables including necessary snap-fit coupler required for fixing.
8Taking out the existing PVC/XLPE, 1100 volts grade, LT UG electric cable of size 25 sqmm x 3.5 core from trenches/ walls (or) passing through pipes/in floor removing the unserviceable fault cable and carefully stacking the serviceable cable for reusing all as specified and directed by the Engr-in- charge Note:- Excavation and Earth work shall be measured and paid separately under appropriate items
9All as per item No.7 above but 35sqmm 3.5 core
10All as per item No.7 above but 50 sqmm 3.5 core
11All as per item No.7 above but 70sqmm 3.5 core
12All as per item No.7 above but 95 sqmm 3.5 core
13All as per item No.7 above but 120sqmm 3.5 core
14All as per item No.7 above but 150 sqmm 3.5 core
15All as per item No.7 above but 185sqmm 3.5 core
16All as per item No.7 above but 240 sqmm 3.5 core
17Laying only the under ground cable any type obtained from Items No -07 above in trench/wall/floor etc are connecting with suitable cable lugs/sleeves etc and size 25 sqmm 3.5 core complete all as specified and directed by Engr-in Charge .
18All as per item No. 16 obtained from item No. 8 above but 35 sqmm 3.5 core
19All as per item no.16 and obtained from item no. 9 but 50 sqmm 3.5 core
20All as per item no.16 and obtained from item no. 10 above but 70 sqmm 3.5 core
21All as per item no. 16 and obtained from item no. 11 above but 95 sqmm 3.5 core
22All as per item no 16 and obtained from item no. 12 above but 120sqmm 3.5 core
23All as per item no 16 and obtained from item no. 13 above but 150sqmm 3.5 core
24All as per item no. 16 and obtained from item no. 14 above but 185sqmm 3.5 core
25All as per item no. 16 and obtained from item no. 15 above but 240sqmm 3.5 core
26Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 25 sqmm 3.5 core.
27All as per item no. 25 above but 35 sqmm 3.5 core
28All as per item no. 25 above but 50 sqmm 3.5 core
29All as per item no. 25 above but 70 sqmm 3.5 core
30All as per item no. 25 above but 95 sqmm 3.5 core
31All as per item no. 25 above but 120sqmm 3.5 core
32All as per item no. 25 above but 150sqmm 3.5 core
33All as per item no. 25 above but 185sqmm 3.5 core
34All as per item no. 25 above but 240sqmm 3.5 core
35Supply and jointing straight through heat shrink joint kit for PVC/XLPE LT UG cable for following size 25 to 50 sqmm 3.5 core
36All as per item No 34 above but 70 to 95 sqmm 3.5 core
37All as per item No 34 above but 120 to 185 sqmm 3.5 core
38All as per item No 34 above but 240 to 300 sqmm 3.5 core
39Taking down of GI pipe laid in trenches or on walls including clamps and joints of any size, complete all as specified and as directed.
40S & L in trenches /fixed on walls by suitable clamps and jointing complete GI pipe light grade of size 50mm dia complete all as specified and as directed.
41S & L in trenches /fixed on walls by suitable clamps and jointing complete GI pipe light grade of size 80mm dia complete all as specified and as directed.
42S & L in trenches /fixed on walls by suitable clamps and jointing complete GI pipe light grade of size 100mm dia complete all as specified and as directed.
43Fabrication and installation of cable route indicator made out of 10 mm thick CI plate , oval shape of suitable size and embossed with Mark of \\" MES LT Cable \\" including 30 cm length angle iron support and embedded in and including PCC complete all as directed.
44M & L Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 ( 8.5 metres long) complete all as specified and as directed.
45Excavation in trenches additional 1.5m or part there of in depth beyond the first 1.5 m and not exceeding 3.0 m and getting out excavated soil soft/loose soil.
46S& F for precast Cement concrete type B1 1:2:4 (20mm graded aggregate complete all as specified and directed by Engr-in-Charge
47S& F for precast Cement concrete type C-2 1:3:6 (40mm graded aggregate complete all as specified and directed by Engr-in-Charge (For Foundation + Base)
48M&L for opening LT, 1100V, ACB front and back side complete after taking shutdown , cleaning, dusting inside & out side of ACB greasing oiling the mechanical parts of ACB and complete servicing including the replacement of the following :-(a) Replacement of tripping coil 440V(b) Replacement of contacts(c) Replacement of wiring for tripping coil(d) Replacement of indicating lamps(e) Replacement of internal wiring for indicating lamps
49S&F MCCB adjustable thermal & magnetic setting 415V, 3 pole, 50Hz of capacity 63Amps 16 KA including taking out old u/s one complete all as specified and as directed.
50S&F MCCB adjustable thermal & magnetic setting 415V, 3 pole, 50Hz of capacity 100Amps 16 KA including taking out old u/s one complete all as specified and as directed.
51S&F MCCB adjustable thermal & magnetic setting 415V, 3 pole, 50Hz of capacity 125 Amps 16 KA including taking out old u/s one complete all as specified and as directed.
52S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 160 Amps 36 KA including taking out old u/s one complete all as specified and as directed.
53S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 200 Amps 36 KA including taking out old u/s one complete all as specified and as directed.
54S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 250 Amps 36 KA including taking out old u/s one complete all as specified and as directed.
55S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 350 Amps 36 KA including taking out old u/s one complete all as specified and as directed.
56S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 400 Amps 36 KA including taking out old u/s one complete all as specified and as directed.
57S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 500 Amps 36 KA including taking out old u/s one complete all as specified and as directed.
58S&F MCCB adjustable thermal & magnetic setting 415V, 4 pole, 50Hz of cap 630 Amps 36 KA including taking out old u/s one complete all as specified and as directed.
59S& F for GI earthing strip 25x4 mm with nut and bolts complete including taking down old one all as specified and directed by Engr- in- Charge
60S&F of GI Strip ISI marked of size 32 x6 mm complete with nuts, bolts and washers,buried in ground including excavation complete all as specified and directed by Engr-in-Charge.
61Material and labour for finding out the cable fault of any size of cable upto LT underground cable and of any capacity of cable with the help of cable fault locator mounting on vehicle and with necessary disconnection of cable from two ends and making connection by joining after repairs and having the following items with electrician at site to find fault of up to length of 10 KM cable complete all as specified and directed by Engr-in-Charge with help of the following accessories- (a) Surge Generator with accessories(b) Head Phone(c) Pin Point Set T-505 with accessories(d) Earthing cable with clamp (e) Cable fault Locator T-905 with accessories (f) TC-808 with accessories (g) Soldering Iron/wire/capacitor unit/capacitor connecting cables/ power cable/nose plier. Notes: Excavation for the cable fault shall be done by the contractor by his own arrangement.
62Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6 mm thick buried directly in ground( earth pit not less than 2.25 m deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI earth strip of size 32x6 mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machinery/equipments installed power house/sub station all as specified including testing on completion complete all as specified and as directed. Note: The unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble ( Notes) Under sub heading earthing specified on SI page NO-451 of SSR Part-II 2020. Total in Figures 0.0 0.0 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57334876
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 01-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repairs/Maint Of Lt External Electrification Distribution Network And Connected Accessories At C & E Area Under Ge Chennai
Basic Detail
Tender No 8963/E8
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 24 Sep 2026
Submission Date 01 Oct 2026
Open Date 03 Oct 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Available
Document List
a8296581-f8b3-4549-8167-0cee08dc96e4.html
BOQ_882906.xls
Tender8963.pdf
Tendernotice_1 (8).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 01, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

a8296581-f8b3-4549-8167-0cee08dc96e4.html

xls

BOQ_882906.xls

pdf

Tender8963.pdf

pdf

Tendernotice_1 (8).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders