Tender For Notice Inviting Tender For The Job Of Renovation Of Ground Floor Passage And Entrance Lobby Of Technical Building For Ammonia And Urea Plant At Rcf Thal
Tender Value
Ref. Documents
Estimated cost
Bid Submission
24 Sep 2026
10 days left
EMD
75000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Raigad → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Notice Inviting Tender For The Job Of Renovation Of Ground Floor Passage And Entrance Lobby Of Technical Building For Ammonia And Urea Plant At Rcf Thal
BOQ
| Sl. No. | Item Description |
| 1 | DISMANTLING EXISTING FLOORING, SKIRTING, TILES, WALL CLADDED MARBLE,MEMBRANE ETC., INCLUDING DISPOSAL OF MATERIALS DEBRIS WITHIN RCF FACTORY PREMISES WITHIN A LEAD OF 3 KM, COMPLETE AS DIRECTED BY ENGINEER-IN-CHARGE. |
| 2 | REMOVING EXISTING LOOSE CEMENT/PLASTER OF ANY FINISH FROM THE WALL, COMPLETE INCLUDING PREPARING SURFACE, NECESSARY SCAFFOLDING, CLEANING ETC. COMPLETE INCLUDING DISPOSAL OF MATERIALS DEBRIS WITHIN RCF FACTORY PREMISES WITHIN A LEAD OF 3 KM.,FOR ALL LOADS INCLUDING ALL LIFTS INVOLVED COMPLETE AS DIRECTED BY ENGINEER-IN-CHARGE. |
| 3 | DEMOLISHING EXISTING BRICK / STONE MASONRY WORK IN CEMENT MORTAR (ANY PROPORTION AT ANY HEIGHTS / DEPTHS INCLUDING STACKING OF SERVICEABLE MATERIALS AND DISPOSAL OF UNSERVICEABLE WITHIN A LEAD OF 3 KM.,,FOR ALL LOADS INCLUDING ALL LIFTS INVOLVED COMPLETE AS DIRECTED BY ENGINEER-IN-CHARGE. |
| 4 | PROVIDING & CHIPPING GROOVES IN WALLS,CEILING OF REQUIRED SIZE & SHAPE FOR CONCEALING OF ELECTRICAL WIRING & MAKING GOOD THE DAMAGED PORTION WITH PMM/PUTTY AS PER EIC WITH NECESSARY SCAFFOLDING ETC. COMPLETE INCLUDING DISPOSAL OF DEBRIS ,FOR ALL LOADS INCLUDING ALL LIFTS INVOLVED AS DIRECTED BY EIC. |
| 5 | REMOVING EXISTING DOORS, WINDOWS WITH FRAMES AND SHUTTERS ETC. COMPLETE. (DISMANTLING, DEMOLISHING, CUTTING, BREAKING, REMOVING & CLEANING EXISTING ITEM CAREFULLY AND STACKING THE MATERIAL AT SITE OR AS INSTRUCTED INCLUDING CARTING AWAY DEBRIS FROM TECHNICAL BLDG. PREMISES WITH PRIOR APPROVAL & PERMISSIONS OF RCF. THE DEMOLISHED / STACKED MATERIAL SHALL BE PROPERTY OF THE CONTRACTOR & SHALL BE RESPONSIBILITY TO TAKE IT OUTSIDE RCF PREMISES). |
| 6 | PROVIDING LIGHT WEIGHT AUTOCLAVED CONCRETE BLOCK MASONRY OF APPROVED BLOCK SIZE USING PREMIXED AND READY TO USE COMPATIBLE MORTAR AS APPROVED BY EIC. |
| 7 | PROVIDING AND APPLYING POLYMER MODIFIED READY MIX CEMENT MORTAR (PMM) FOR PLASTERING/ MICRO CONCRETE (PMC) OF ANY THICKNESS AS PER SITE REQUIREMENT OF APPROVED BRAND INCLUDING CURING ETC. AS PER MANUFACTURER'S SPECIFICATIONS OR AS PER INSTRUCTIONS OF ENGINEER IN-CHARGE (THE ITEMS SHALL BE PAID ON ACTUAL CONSUMPTION OF READY MIX QUANTITY ONLY).THE RATE SHALL BE INCLUSIVE OF SURFACE PREPARATION BEFORE APPLICATION AS PER THE MANUFACTURER'S SPECIFICATIONS INCLUDING NECESSARY FORMWORK, APPLYING RUST CONVERTER, RUST INHIBITOR COAT, BOND COAT ETC. AS DIRECTED BY EIC AT ALL HEIGHTS INCLUDING M.S. PIPE SCAFFOLDING ETC. COMPLETE. THE ITEM SHALL BE PAID FOR PLASTER THICKNESS OF 10MM TO 15MM. |
| 8 | PROVIDING AT ALL HEIGHTS 12 MM THICK INTERNAL CEMENT PLASTER ON BRICK WORK, EXPOSED SURFACES OF RCC LINTELS, BEAMS, ETC., COMPLETE IN ALL RESPECTS AND AS DIRECTED WITH CEMENT PLASTER MIX : 1:4 (1CEMENT : 4 KHARSALIA SAND) INCLUDING NECESSARY SCAFFOLDING, CURING ETC. COMPLETE. |
| 9 | PROVIDING AND APPLYING 8 TO 10 MM THICK POP WALL PUNNING AS REQUIRED TO INTERNAL WALLS INCLUDING SCRAPPING OF EXISTING PAINT OR ON NEW SURFACES WITH LINE & LEVEL TO MAKE SURFACE SMOOTH. |
| 10 | PROVIDING AND FIXING 40MM DIAMETER AND 1.5MM THICK STAINLESS STEEL RAILING IN S.S.304 GRADE INCLUDING FABRICATING, FIXTURES, ERECTING, NECESSARY WELDING, GRIDING, FINISHING, BUFFING TO STAINLESS STEEL PIPE ETC. COMPLETE WITH NECESSARY STAINLESS STEEL NUTS AND BOLTS COMPLETE, I/C FIXING THE RAILING WITH NECESSARY ACCESSORIES AND STAINLESS STEEL DASH FASTENERS, STAINLESS STEEL BOLTS, ETC (SAMPLE DESIGN SHALL BE APPROVED) |
| 11 | PROVIDING & APPLYING ASIAN PAINTS / NEROLAC / BERGER LUSTRE PAINT AS REQUIRED TO INTERNAL WALLS & CEILING AS PER MANUFACTURER'S SPECIFICATIONS WHICH INCLUDE SCRAPPING THE WALL, APPLYING 1 COAT OF PRIMER & 2/3 COATS OF PUTTI, SCRAPPING THE WALL WITH WATER PAPER AND APPLYING 2 COATS OF LUSTRE PAINT. |
| 12 | PROVIDING AND LAYING VITRIFIED TILES OF SOMANY/RAK/KAJARIA/NITCO/ASIAN OR EQUIVALENT MAKE HAVING SIZE BETWEEN 800 TO 1200 MM X 800 MM TO 1200 MM (THICKNESS TO BE SPECIFIED BY MANUFACTURER) AND CONFIRMING TO IS 15622-2006 OF APPROVED MAKE, SHADE AND PATTERN FOR FLOORING/SKIRTING IN REQUIRED POSITION LAID ON A BED OF 1:4 CEMENT MORTAR INCLUDING NEAT CEMENT FLOAT, FILLING JOINTS, CURING AND CLEANING ETC. COMPLETE.APPROVAL FOR SIZE OF TILE TO BE PRIOR APPROVED BY RCF. |
| 13 | PROVIDING & FIXING BLACK GRANITE STONE APPROX. 18 TO 20 MM THICK FOR DOOR & WINDOW SILLS/JAMBS/FRAME/RISER/TREAD ETC. IN SINGLE/DOUBLE STEM IN 1:6 INCLUDING NOSING SHARP EDGES WHEREVER NECESSARY AS DIRECTED BY EIC. |
| 14 | PROVIDING, SUPPLING & FIXING 12MM THICK SINGLE LEAF TOUGHNED GLASS DOOR OF SAINT GOBAIN/MODI/ASAI MAKE WITH 6/8\\" AS DIRECTED POLISHED WOODEN PATTI AT TOP & BOTTOM. THE GLASS DOOR SHALL BE MADE OPERATABLE ON FLOOR SPING OF ENOX/OMEGA MAKE & CAPABLE TO TAKING ITS LOAD WITH OTHER PATCH FITTINGS SUCH AS LOCK, BOTTON & TOP PATCH, PIVOT, 2' HIGH SS FINISH HANDLEON BOTH SIDES, PUSH/PULL INDICATOR, ETC. THE DOOR MAY ALSO HAVE SS FINISH BRASS MAKE STOPPER FIXED ON TOP AS DIRECTED BY EIC |
| 15 | PROVIDING & FIXING 30 MM THICK SINGLE LEAF SOLID CORE FLUSH DOOR WITH APPROVED SHADE LAMINATE (1 MM) FINISH INCLUDING NECESSARY HARDWARE, FITTINGS & FIXTURES LIKE CYLINDRICAL DOOR LOCK, CHROMIUM PLATED HANDLES ON BOTH SIDES, PVC DOOR STOPPER, BRASS MAKE ISI MARKED HYDRAULIC DOOR CLOSER, POLISH TO ALL EXPOSED SURFACES, EDGES, ETC. COMPLETE AS PER DETAIL DRAWING. IF REQUIRED, THE DOOR SHALL HAVE 2' X 3' (OR AS DIRECTED) 5 MM THK. PLAIN GLASS AT TOP FIXED WITH BEADING PATTI ALL AS SPECIFIED AND AS DIRECTED. |
| 16 | SUPPLYING AND PASTING GARWARE OR EQUIVALENT POLYESTER FILM, OF APPROVED COLOUR & REFLECTIVE RANGE OVER GLASS PANES AT ALL ELEVATION INCLUDING PREPARATION OF GLASS, SPRAYING OF CHEMICAL OVER GLASS, PRESSING OF FILM BY WIPER WITHOUT ANY BUBBLES DONE BY A PROFESSIONAL AGENCY COMPLETE TO THE SATISFACTION OF ENGINEER-IN-CHARGE. |
| 17 | PROVIDING AND FIXING 1.5 MM THICK LAMINATES (OF MAKE GREENLAM, CENTURY, MERINO OR EQUIVALENT) TO FULL HEIGHT/LOW HEIGHT PARTITIONS AND ANY OTHER LOCATIONS WITH FINISH AS DIRECTED BY EIC. |
| 18 | DISMANTLING / REMOVING OF CONCRETE BY CHISELLING, WEDGING, ETC.INCLUDING CUTTING REINFORCEMENT, STACKING THE SERVICEABLE MATERIALS AND DEBRIS SEPARATELY OR SPREADING THE DEBRIS AND DEPOSITING METAL SCRAP IN SCRAP YARD WITHIN FACTORY AREA AS DIRECTED ETC. COMPLETE. |
| 19 | PROVIDING & FIXING OF ALUMINUM LAY IN MICRO PERFORATED OF ARMSTRONG OR EQUIVALENT MAKE (1.8MM DIAMETER-20% OPEN AREA) METAL CEILING CONSISTING OF 600X600MM LAY IN TILES IN 0.7 MM THICK ALUMINUM PRE COATED TO GLOBAL WHITE COLOR WITH ACOUSTICAL FLEECE HOT PRESSED ON THE BACK OF THE PERFORATED TILE & 50 MM THK. RESIN BONDED GLASS WOOL BACKING TO BE LAID ON ARMSTRONG GRID SYSTEMS WITH 24MM WIDE T - SECTION FLANGES COLOR WHITE HAVING ROTARY STITCHING ON THE MAIN RUNNER, 1200 MM & 600 MM CROSS TEES. THE TILES WOULD HAVE NRC OF 0.50, FIRE PERFORMANCE OF CLASS A2-S1.D0 AS PER EN13501 STANDARD IN MODULE SIZE OF 600 X 600MM, SUITABLE FOR GREEN BUILDING APPLICATION, WITH RECYCLED CONTENT OF 50%. THE TILE SHALL BE LAID ON 24 MM WIDE T - SECTION FLANGES COLOUR WHITE HAVING ROTARY STITCHING ON ALL T SECTIONS I.E. THE MAIN RUNNER, 1200 MM & 600 MM CROSS TEES WITH A WEB HEIGHT OF 38MM AND A LOAD CARRYING CAPACITY OF 15.34KGS/M2& PULL OUT STRENGTH OF 100KGS. THE T SECTIONS HAVE A GALVANIZING OF 90 GRAMS PER M2 AND NEED TO BE INSTALLED WITH SUSPENSION SYSTEM. |
| 20 | PROVIDING AND FIXING PREMIUM QUALITY VITRIFIED TILES OF SOMANY / RAK / KAJARIA / NITCO / JHONSON MAKE OF APPROVED SHADE & DESIGN IN DIGITAL SERIES MAKE OF SIZE 1'X2' (300 MM X 600 MM) / 18\\"X12\\" FOR DADO IN REQUIRED POSITION IN PERFECT LINE & LEVEL OVER CEMENT MORTAR 1:4 INCLDUING CEMENT FLOAT, FILLING JOINT WITH WHITE/COLOUR CEMENT SLURRY, CLEANING, CURING, ETC. COMPLETE. |
| 21 | DISMANTLING THE EXISTING STRUCTURAL STEEL WORKS IN COLUMNS, PORTALS, BEAMS, GIRDERS, BRACINGS, TRUSSES RAFTERS, PURLINS, STAIR CASES, STEPS GANTRIES, TRESTLES, WALKWAYS, RAILING SIDE RUNNERS, LOUVERS, ETC., IN SINGLE SECTION/ BUILT UP OR COMPOUND SECTION IN R.S. JOISTS, CHANNELS, ANGLES, TEES, PLATES, BASE PLATES, LACINGS, BOLTS NUTS, CUTTING RIVETS / WELDING AT ALL HEIGHTS INCLUDING STACKING SEPARATELY THE SERVICEABLE, HANDING OVER THE SAME TO THE OWNER'S / CONSULTANT'S STORE/SCRAP YARD AT SITE AND DISPOSAL OF UNSERVICEABLE MATERIALS TO STORE/SCRAP YARD IN FACTORY, COMPLETE IN ALL RESPECTS AND AS DIRECTED BY ENGINEER -IN- CHARGE.PAYMENT AS PER RCF WEIGH BRIDGE WEIGHMENT CHALLAN. |
| 22 | SUPPLYING AND FIXING IN POSITION COLOUR ANODISED ALUMINIUM SECTION THREE/TWO TRACK SLIDING WINDOWS WITH MOSQUITO JALLI WITHOUT BOX FRAME MADE UP OF FOUR/THREE TRACK DRAIN BOTTOM SECTION OF SIZE 92 X 31.75 X 1.3 MM THK (WT. 0.637 KG/M) AND TOP AND SIDES SECTIONS OF SIZE 92 X 31.75 X 1.3 MM THK (WT. 1.07 KG/M). THE SHUTTER SHOULD BE OF BEARING BOTTOM OF SIZE 40 X 18 X 1.25 MM THICK (WT. 0.417 KG/M), TOP MEMBER OF SIZE 40 X 18 X 1.25 MM (WT. 0.417 KG/M) THICK, INTER LOCKING SECTION SIZE OF 40 X 18 X 1.25 MM THICK (WT. 0.417 KG/M) AND HANDLE SECTION SIZE OF 52 X 18 X 1.13 MM THICK (WT. 0.488 KG/M) SELECTED QUALITY 5 MM THK CLEAR GLASS TO BE FIXED IN SHUTTER WITH NEOPRENE GASKET WITH APPROVED QUALITY PVC ROLLERS NECESSARY LOCKS HANDLES PVC LINING AND WOODEN ENCASEMENT WHEREVER NECESSARY ETC. COMPLETE AS DIRECTED BY ENGINEER IN CHARGE. |
| 23 | PROVIDING AND FIXING SUPERIOR TYPE BELGIUM MIRROR ETC. COMPLETE AS DIRECTED APPROVED BY EIC. |
| 24 | PROVIDING AND LAYING 1:2:4 (1 CEMENT: 2 FINE AGGREGATE :4 GRADED STONE AGGREGATE 20 MM NOMINAL SIZE). PLAIN CEMENT CONCRETE, MANUAL / MACHINE MIXED AND MANUAL / MECHANICALLY VIBRATED IN FOUNDATIONS, PLINTH, UNDER FLOORS,SCREEDING AS PER EIC ETC., INCLUDING ALL NECESSARY COST OF CENTRING AND SHUTTERING & CURING ETC. COMPLETE : |
| 25 | PROVIDING SUPPLYING, DE-RUSTING BY SHOT BLASTING FABRICATING, ERECTING, HOISTING AND FIXING IN POSITION STRUCTURAL STEEL WORK IN ROLLED STEEL JOINTS, CHANNELS, ANGLES TEES, FLATS, PLATES, LATTICE MEMBERS BUILT UP / COMPOUND SECTIONS IN COLUMNS, PORTALS, GIRDERS, BEAMS, BRACINGS, TRUSSES, PURLINS, RAFTERS, STAIRCASE, STEPS, HAND-RAILINGS, WALKWAY, CAT LADDER WITH CAGES, TOE PLATES, SIDE WALLING, TRESTLES, CONVEYOR GANTRIES ETC. INCLUDING GUSSET PLATES, ETC., INCLUDING SITE AND SHOP FASTENERS, RIVETING, BOLTING, WELDING AT SHOP OR WORK SITE AT ALL HEIGHTS INCLUDING SCAFFOLDING WITH MS PIPE ETC.SURFACE PREPARATION SURFACE PREPARATION FOR ALL THE ITEMS TO BE PAINTED AFTER SLAG BLASTING.AIR USED FOR SLAG BLASTING MUST BE DRY AND OIL FREE.SLAG USED FOR BLASTING MUST BE OF GOOD QUALITY FOR ACHIEVING SURFACE FINISH AS DIRECTED BY EIC.SLAG BLASTED SURFACE MUST BE COATED WITH PRIMER WITHIN 2 HOURS.PAINTING SYSTEM TO BE USED AS INDICATED BELOW. I. P1-ONE COAT OF ETHYL SILICATE INORGANIC ZINC PRIMER HAVING DFT OF 70 MICRONS PER COAT.II .IP1ONE COAT OF EPOXY MIO HAVING DFT OF 70 MICRONS PER COAT.III.FP1 ONE COAT OF FINISH EPOXY PAINT USING TWO PACK POLYAMIDE CURED EPOXY HAVING DFT OF 40 MICRONS PER COAT.IV.FP2 - ONE COAT OF ALIPHATIC ACRYLIC POLYURETHANE PAINT HAVING DFT OF 40 MICRONS PER COAT. ETC COMPLETE AS DIRECTED BY EIC. (ALL MATERIAL SUPPLY IS IN CONTRACTOR’S SCOPE INCLUDING PAINTS (AS PER TS). (ONLY TATA/SAIL/JINDAL/RINL MAKE STEEL TO BE USED) . |
| 26 | FABRICATING STRUCTURAL STEEL WORK IN ROLLED SECTIONS, FIXED WITH CONNECTING PLATES OR ANGLE CLEATS IN MAIN AND CROSS BEAMS, HIP AND JACK RAFTERS, PURLINS CONNECTING TO TRUSS MEMBERS, JOISTS, CHANNELS, ANGLES, TEES GRATINGS, RAILING, GI PIPE, GRATTING ETC. AS PER DETAILED DESIGNS AND DRAWING OR AS DIRECTED INCLUDING CUTTING, FABRICATING, HOISTING, ERECTING, FIXING IN POSITION, MAKING RIVETED / BOLTED / WELDED CONNECTIONS AND ONE COAT OF ANTICORROSIVE PAINT AND OVER IT TWO COATS OF EPOXY PAINTING COMPLETE (RCF WILL SUPPLY ONLY STRUCTURAL STEEL AND CONSUMABLE GASES IF AVAILABLE FREE OF COST AT RCF STORES CONTRACTOR HAS TO SHIFT THE MATERIAL FROM STORES TO SITE AT OWN COST.) |
| 27 | DISMANTLING OF ROOFING (METALLIC/CEMENT) AT ANY HEIGHT INCLUDING RIDGES, HIPS, VALLEYS AND GUTTERS ETC., AND STACKING THE MATERIAL WITHIN 50 METRES LEAD. |
| 28 | PROVIDING & APPLYING TWO OR MORE COATS OF 100% EXTERIOR GRADE ACRYLIC EMULSION PAINT (WEATHERSHIELD OR APEX) COLOUR /SHADE AS PER APPROVED BRAND AND MAKE TO EXTERIOR OLD/ NEW RCC/MASONRY SURFACES AFTER ONE COAT OF COMPATIBLE WATERPROOF PRIMER, NECESSARY CLEANING ETC. COMPLETE AS DIRECTED BY EIC. |
| 29 | PROVIDING AT ALL HEIGHTS 20 MM THICK CEMENT PLASTER ON SINGLE OR HALF BRICK WALLS IN ALL POSITION INCLUDING BASE COAT OF 12 MM THICK IN CEMENT MORTAR 1:4(1CEMENT:4 READY MIXED GRADED PLASTER SAND) USING WATERPROOFING COMPOUND AT 1 KG PER CMENT BAG CURING THE SAME FOR NOT LESS THAN 2 DAYS AND KEEPING THE SURFAE OF THE BASE COAT ROUGH TO RECEIVE THE SAND FACED TREATMENT 8 MM THICK IN CEMENT MORTAR 1:4 FINISHING BY TAKING OUT GRAINS AND CURING FOR 14 DAYS , ETC., COMPLETE IN ALL RESPECTS AND AS DIRECTED INCLUDING NECESSARY SCAFFOLDING, CURING ETC. COMPLETE. |
| 30 | PROVIDING & FIXING EXTERIOR GRADE ALUMINUM COMPOSITE PANELS 3 MM THICK WITH SHEET OF APPROVED QUALITY AND MAKE(VIVA,EURO OR EQUIVALENT APPROVED MAKE) TO RCC STRUCTURES/BRICKWORK IN PLAIN CLEAR OR ANY APPROVED COLOUR WITH HEAVY SECTIONAL ALUMINUM FRAME WORK AND CLADDING COMPOSITES WITH SILICON SEALANTS INCLUDING PROVIDING SCAFFOLDING AND INSTALLATION IN PROPER LINE AND LEVEL AS DIRECTED BY EIC COMPLETE. |
| 31 | PROVIDING AND APPLYING (BY BRUSH/SPRAY) WATERPROOF ANTICARBONATION COATING ON EXTERIOR WALLS (SHALICRYL 215P OF M/S STP LTD OR KRISHNA CONCHEM OR EQUIVALENT AS APPROVED BY EIC) AS PER APPROVED SHADE IN TWO COATS INCLUDING M.S. PIPE SINGLE SCAFFOLDING(PUTLOG SCAFFOLD)/SUSPENDED ROPE PLATFORM, PREPARING THE SURFACES BY BRUSHING,WATERJET CLEANING AND BROOMING DOWN ETC. COMPLETE WITH ONE COAT OF PRIMER AS PER MANUFACUTRES SPECIFICATION ETC. COMPLETE AS DIRECTED BY EIC. |
| 32 | PROVIDING AND LAYING HEAVY DUTY EXTERIOR GRADE TILE OF APPROX. SIZE 300 MM X 300 MM, 15 MM THICKNESS (JHONSON ENDURA OR EQUIVALENT) FOR EXTERNAL AREA OVER 20 MM THK. CEMENT MORTAR 1 : 3 OF APPROVED COLUR SHADE & DESIGN AS DIRECTED. |
| 33 | PROVIDING & FIXING IN POSITION MISC. MATERIALS NOT COVERED IN THE SCHEDULE OF RATES MENTIONED ABOVE INCLUDING TRANSPORTING, LOADING, UNLOADING AT SITE ETC. (CASH RECEIPT TO BE SUBMITTED). |
| 34 | PROVIDING AND FIXING SINGLE LEAF FRP DOOR SHUTTER 30 MM THICK OF APPROVED SHADE AND PATTERN INCLUDING NECESSARY HARDWARE, LOCK, DOOR STOPPER, HANDLES AND OTHER FITTINGS ETC. AS DIRECTED BY EIC. |
| 35 | PROVIDING AND FIXING FRP MESH AS APPROVED BY EIC FOR WALLS, COLUMNS, BEAM JUNCTION AS DIRECTED BY EIC |
| 36 | PROVIDING AND FIXING ISI MARKED HYDRAULIC DOOR CLOSER (80 TO 90 KG CAPACITY) FOR ALUMINIUM DOORS/WOODEN DOORS AS DIRECTED BY EIC. |
| 37 | PROVIDING AND FIXING TILED FALSE CEILING OF SPECIFIED MATERIALS OF SIZE 595X595 MM IN TRUE HORIZONTAL LEVEL, SUSPENDED ON INTERLOCKING METAL GRID OF HOT DIPPED GALVANIZED STEEL SECTIONS ( GALVANIZED @ 120 GRAMS/ SQM, BOTH SIDE INCLUSIVE) CONSISTING OF MAIN \\"T\\" RUNNER WITH SUITABLY SPACED JOINTS TO GET REQUIRED LENGTH AND OF SIZE 24X38 MM MADE FROM 0.30 MM THICK (MINIMUM) SHEET, SPACED AT 1200 MM CENTER TO CENTER AND CROSS \\"T\\" OF SIZE 24X25 MM MADE OF 0.30 MM THICK (MINIMUM) SHEET, 1200 MM LONG SPACED BETWEEN MAIN \\"T\\" AT 600 MM CENTER TO CENTER TO FORM A GRID OF 1200X600 MM AND SECONDARY CROSS \\"T\\" OF LENGTH 600 MM AND SIZE 24X25 MM MADE OF 0.30 MM THICK (MINIMUM) SHEET TO BE INTERLOCKED AT MIDDLE OF THE 1200X600 MM PANEL TO FORM GRIDS OF 600X600 MM AND WALL ANGLE OF SIZE 24X24X0.3 MM AND LAYING FALSE CEILING TILES OF APPROVED TEXTURE IN THE GRID INCLUDING, REQUIRED CUTTING/MAKING, OPENING FOR SERVICES LIKE DIFFUSERS, GRILLS, LIGHT FITTINGS, FIXTURES, SMOKE DETECTORS ETC. MAIN \\"T\\" RUNNERS TO BE SUSPENDED FROM CEILING USING GI SLOTTED CLEATS OF SIZE 27 X 37 X 25 X1.6 MM FIXED TO CEILING WITH 12.5 MM DIA AND 50 MM LONG DASH FASTENERS, 4 MM GI ADJUSTABLE RODS WITH GALVANIZED BUTTERFLY LEVEL CLIPS OF SIZE 85 X 30 X 0.8 MM SPACED AT 1200 MM CENTER TO CENTER ALONG MAIN T, BOTTOM EXPOSED WIDTH OF 24 MM OF ALL T-SECTIONS SHALL BE PRE-PAINTED WITH POLYESTER PAINT, ALL COMPLETE FOR ALL HEIGHTS AS PER SPECIFICATIONS, DRAWINGS AND AS DIRECTED BY ENGINEER-IN-CHARGE. PROVIDING AND FIXING 8 MM THICK PERFORATED CALCIUM SILICATE BOARD MADE WITH CALCAREOUS & SILICEOUS MATERIALS REINFORCED WITH CELLULOSE FIBER MANUFACTURED THROUGH AUTOCLAVING PROCESS TO GIVE STABLE CRYSTALLINE STRUCTURE WITH MINIMUM COMPRESSIVE STRENGTH 225 KG/ SQ. CM, BENDING STRENGTH 100 KG/SQ. CM , OF SIZE 595X595 MM, HAVING PERFORATION OF DIA. 10 MM WITH MINIMUM PERFORATED AREA 18 % WITH NON WOVEN TISSUE ON THE BACK SIDE, HAVING AN NRC ( NOISE REDUCTION COEFFICIENT) OF 0.85. |
| 38 | PROVIDING AND FIXING 12 MM THICK IS:303 BWR GRADE WATERPROOF PLYWOOD, FULL RED CORE TO FRAME OF WINDOWS IN WALL PANELS AS DIRECTED BY EIC. |
| 39 | POINT WIRING FOR POINTS - POINT WIRING THROUGH 20/25 MM HMS PVC CONDUIT WITH ALL REQUIRED ACCESSORIES WITH 2 NOS OF 1.5 SQMM & 1 NO OF 1.5 SQMM ( FOR EARTH) PVC INSULATED COPPER FRLS WIRES WITH MODULAR TYPE SWITCHES COMPLETE WITH ALL ACCESSORIES AS DETAILED IN THE SPECIFICATIONS. THE SWITCH BOXES SHALL BE FLUSH MOUNTED WITH PARTITION WORKS OR AS DIRECTED BY THE ARCHITECTS AND SHALL BE DONE IN CO-ORDINATION WITH INTERIOR FURNITURE WORKS. THE RATE SHALL INCLUDE CIRCUIT WIRING FROM DB TO SWITCHBOARD & FROM SWITCHBOARD TO SWITCHBOARD. 2 NOS OF 2.5 SQMM & 1 NO OF 2.5 SQMM (FOR EARTH) PVC INSULATED COPPER FRLS CONDUIT SHALL BE FIXED ON WALL / TRAYS OR CEILING WITH SPACERS & SADDLES. THE WIRES WILL BE TERMINATED IN A SEPARATE CONNECTOR BEFORE FIXTURES. APPROVED MAKES:-CONDUITS-PRECISION/DIAMOND,FINOLEX,KALINGA WIRES-FINOLEX/POLYCAB, SWITCHES-CLIPSAL-OPALE/NORTHWEST/SALZER/ANCHOR/CRABTREE/SSK |
| 40 | PRIMARY POINTS (3C*2.5 SQ.MM)(SWITCH BOX TO FIRST LIGHT POINT INCL. SUPPLY OF SWITCH & WIRING ACCESS.) |
| 41 | POINT WIRING WITH 3C*1.5 SQ.MM CU.FR LS WIRES IN PVC CONDUITS FROM PRIMARY POINTS TO SECONDARY POINTS |
| 42 | SECONDARY POINTS (LOOPING FROM PRIMARY POINT ONWARDS) |
| 43 | SECONDARY POINTS (1/2 POINT) ON SAME SWITCH BOARD 6 AMP WITH ACCESS. |
| 44 | SECONDARY POINTS (1/2 POINT) ON SAME SWITCH BOARD 6/16 AMP 5 PIN WITH ACCESS |
| 45 | POINT WIRING/POWER WIRING FOR PASSAGES - SUPPLY & INSTALLATION OF THE FOLLOWING SOCKETS, SWITCHES - POINT WIRING THROUGH ALREADY LAID FLOOR RACEWAYS & CONDUITS WITH ALL REQUIRED ACCESSORIES WITH 2 NOS OF 2.5 SQMM & 1 NO. OF 2.5 SQMM (FOR EARTH) PVC INSULATED COPPER FRLS WIRES WITH MODULAR TYPE SWITCHES & SOCKETS COMPLETE WITH ALL ACCESSORIES AS DETAILED IN THE SPECIFICATIONS. THE SWITCH BOXES SHALL BE FLUSH MOUNTED WITH PARTITION WORKS OR AS DIRECTED BY THE ARCHITECTS AND SHALL BE DONE IN CO-ORDINATION WITH INTERIOR FURNITURE WORKS. THE RATE SHALL INCLUDE CIRCUIT WIRING FRLS FROM DB TO SWITCHBOARD AND SOCKET TO SOCKET. APPROVED MAKES : WIRES-FINOLEX/ POLYCAB/HAVELLS/KEI/KEC/APAR, SWITCHES- CLIPSAL-OPALE/ NORTHWEST/ SALZER/ANCHOR/CRABTREE/SSK |
| 46 | 1 NO. OF 6 A SOCKETS & 1 NO. 6A SWITCH (RAW POWER) |
| 47 | Supply and laying of 2 Nos of 2.5 sqmm & 1 no. of 2.5 sqmm (for earth) PVC insulated Copper FRLS sheathed cable as spare cables through floor raceways and conduitcs |
| 48 | SUPPLY AND LAYING RACEWAYS / CONDUITS (FOR UNDER FLOOR TRENCHES/ON TRAYS) ON EXISTING FLOORING. RACEWAYS/CONDUITS SHALL BE FIXED TO THE FLOORING WITH GI CLAMPS FOR FINISHED LEVELS AS PER THE SITE CONDITIONS OR THROUGH PARTITIONS WITH ALL ACCESSORIES. THE RATE SHALL PREPARATION OF TRENCHES UPTO 22” WIDE BY CAREFULLY REMOVING THE FLOOR TILES & MALWA BELOW THE TILES FOR LAYING RACEWAYS/CONDUITS FOR POWER, TELEPHONES ETC. THE DEPTH OF THE TRENCHES SHALL BE AT LEAST 2 INCHES FROM THE FINISHED FLOOR LEVEL OR UPTO RCC OF THE SLAB. THE RATE SHALL INCLUDE THE COST OF THE RACEWAYS/CONDUITS. THE RATE SHALL INCLUDE THE ACTIVITY OF CLEARING THE DEBRIS GENERATED FROM THE PREPARATION OF TRENCHES & FILLING THE SAME WITH PCC 1:2:3 9FOR THE PORTION WITHOUT FALSE FLOORING), APPROVED MAKES : GEETA/JINDAL |
| 49 | 80MM X 38MM X 2MM THICK RECTANGULAR ALUMINUM SECTION FOR ROUTING OF ELECTRICAL, DATA & VOICE CABLES AS SPECIFIED |
| 50 | 25 MM RIGID HG PVC CONDUITS |
| 51 | SUPPLY AND LAYING OF SHEET STEEL FABRICATED METAL JUNCTION BOXES WITH KNOCKOUT HOLES ON THE SIDE WALLS OF THE BOX AND STAINLESS STEEL COVER OF 2.5/3 MM THICKNESS WITH A GASKET TO MAKE THE INSTALLATION WATER PROOF. JUNCTION BOXES SHALL BE FABRICATED FROM 16 GAUGE CRCA SHEETS DULY PAINTED WITH TWO COATS OF RED OXIDE PRIMER AND TWO COATS OF SYNTHETIC ENAMEL PAINT AND SHALL BE PROVIDED AT SUITABLE LOCATIONS SO THAT THE CABLES MAY BE PULLED OR REPLACED OF ADDITIONAL CABLES MAY BE PULLED WHENEVER REQUIRED IN FUTURE. COVER FOR THE TRUNKING SHALL ALSO BE FABRICATED AS ABOVE AND SHALL BE FIXED WITH RUST PROOF BRASS COUNTER SUNK LEVELER TYPE SCREWS. |
| 52 | S & I OF FLOOR JUNCTION BOXES OF SIZE 300MM X 300MM X 50MM |
| 53 | S & I OF FLOOR JUNCTION BOXES OF SIZE 200MM X 200MM X 50MM |
| 54 | LIGHTING FIXTURES - SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF FOLLOWING ITEMS, APPROVED MAKES: WIPRO/ PHILIPS/ HAVELLS - |
| 55 | INDOOR COMMERCIAL RECESS MOUNTED LED LUMINAIRE. LIGHT FIXTURE COMPLETE WITH 1 X 36W LED LAMP.(600 X 600) APPROVED MAKE:BAJAJ,C&G,HAVELLS. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender