Drinking Water Supply and Sanitation Local Bodies Closing in 8 days TDR #57334520

Tender For Construction Of Flag Hosting Stage And Repair And Maintenance Work Rdma Office Premises In Vellore

Issued by Local Bodies · Tirupathur, Tamil Nadu
Tender Value
9.20 Lakhs
Estimated cost
Bid Submission
24 Sep 2026
8 days left
EMD
9200
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Tirupathur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Flag Hosting Stage And Repair And Maintenance Work Rdma Office Premises In Vellore

BOQ

Name of Work:- Construction of Flag Hosting Stage and Repair and Maintenance work RDMA Office Premises in Vellore
Sl. No. Item Description
1Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means
2Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.-Mixing by mechanical means
3Supplying and fixing of cuddappah slab of 20/30 mm thick including all cost and conveyance and all other labor charges etc., complete.
4Brick work in following Cement Mortar using best quality Burnt Clay Brick of size 9” x 4 3/8” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally.other type of bond shall be done as directed by the Executive Engineer in charge. ( Cement Mortar of 1: 5)
5Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
6Paving pre-polished concrete anti-skid step tiles (Required shape and design) of 20mm thick of approved quality and colour laid in accordance with IS 1443 in Cement Mortar 1:3 (One Cement and Three crushed stone sand), with required Cement Slurry and Mortar Plasticizer, 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
7UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
8Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
9Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification
10White washing three coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed.
11Painting New Plastered Wall Surface with Two finishing coats of ready mixed (Emulsion) of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
12Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with Two coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
13Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC.unsheathed Cu. Conductor of 1100 V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW witch box and 5A F.T. switch with painting of suitable Colourfor open PVC light point / fan point (For electronic regulator) (6points per coil) SD-20
14Supply and fixing of single box type 4'40W fluorescent fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed copper leads from terminals to the fitting SD 88
15Supply and fixing of 16A 3 Pin Switched Socket - 3 Module including loading, unloading, transportation and labour charges charges etc., complete
16Supply and fixing of 1200mm (48\\") AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp SD 110
17Supply and run of 2of4sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade insuitable heavy gauge Mscoundit pipe on wall and ceiling with continous earth wire cnnection of 4sq.mm copper wire with painting of suitable colour SD 44
18Supply and Fixing of Rain water Harvesting
19Supply and delivery and fixing of of HDPE Water Tank as per IS 12701 / 1996 including loading, unloading, transportation and labour charges for fixing of the GI pipes and specials for pipe connection works including cutting, threading and fixing charges etc., complete
20Supply and delivery and fixing of of Pressure Motor( Compressor) including loading, unloading, transportation and labour charges for fixing of the PVC pipes and specials for pipe connection works charges etc., complete
21Supply ,erection and commissioning of 25L capacity reverse osmosis water treatment system with Membrane Element, Booster Pump, Reject Water Control Mechanism, Power Supply, Auto Shut-off Mechanism etc with ISI Make inculdind cost of Materials and Labour charges etc complete as directed by departmental officers
22Removal of submersible pump set by Machineries and its accessories from borewell for attending repairs with the rates of Labour Charges for Erection of Submersible Pumpset mentioned etc., complete
23Supply and fixing of following PVC pipes specials & water supply arrangements including etc complete., 32mm PVC Pipe
2425 mm UPVC pipe
2532 mm PVC Elbow
2632 mm PVC Bend
27110 mm PVC Pipe
28PVC Hose Pipe
29Fancy Light
30Provision for GST @ 18 %
31Labour Welfare Fund 1% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57334520
AUTHORITY Local Bodies
TENDER VALUE 9.20 Lakhs
LAST DATE 24-09-2026
Authority
Authority Name Municipal Adminitration And Water Supply Department
Work Description Tender for Construction Of Flag Hosting Stage And Repair And Maintenance Work Rdma Office Premises In Vellore
Basic Detail
Tender No E1/64/2026
Bidding Type Tender
Location
City Tirupathur
State Tamil Nadu
Key Dates
Publish Date 03 Sep 2026
Submission Date 24 Sep 2026
Open Date 24 Sep 2026
Finance
Tender Value 9.20 Lakhs
Tender Fee Ref. Documents
EMD 9200
Exemption Available
Document List
BOQ_843019.xls
f3fc6a85-ea96-43c1-b79d-d479c5597db5.html
Tendernotice_1 (14).pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Sep 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_843019.xls

html

f3fc6a85-ea96-43c1-b79d-d479c5597db5.html

pdf

Tendernotice_1 (14).pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders