Tender For Special Repair To Internal Pipeline And Conversion Of Ci Pipe Into Pvc Pipes At Certain Bldgs At Darjipura At Af Stn Vadodara
Tender Overview
Project Description
Tender for Special Repair To Internal Pipeline And Conversion Of Ci Pipe Into Pvc Pipes At Certain Bldgs At Darjipura At Af Stn Vadodara
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 17-Sep-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 24-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking up or down steel tubing and connections for 15mm bore, including cleaning for refixing or removal to store |
| 2 | Taking up or down steel tubing and connections for 20 mm bore, including cleaning for refixing or removal to store |
| 3 | Taking up or down steel tubing and connections for 25 mm bore, including cleaning for refixing or removal to store |
| 4 | M&L for 16 mm outer dia CPVC pipe SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors includes all plain CPVC fittings and pipe cutting, fixing with CPVC solvent cement and testing, All pipes & fittings of CPVC are UV Stable, leak proof, tough, rigid and suitable for internal and external water supply applications. One step CPVC yellow solvent cement or equivalent as approved by Engr-in-Charge/GE to be used for pipe & fittings Complete all as specified and directed. |
| 5 | S&F 20mm bore GI tube medium grade including all fittings of pressure rating 10 kgf/cm2 fixed complete to walls,ceiling or in floors etc complete to walls and ceiling or laid in floors, etc complete and making good the area to match with existing surface complete all as specified and directed |
| 6 | S&F 25mm bore GI tube medium grade including all fittings of pressure rating 10 kgf/cm2 fixed complete to walls,ceiling or in floors etc complete to walls and ceiling or laid in floors, etc complete and making good the area to match with existing surface complete all as specified and directed |
| 7 | M&L for Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of shelves , for water tubing etc and making good, cutting exc 10cm girth but not exc 20cm girth in stone walls. |
| 8 | Demolition and breaking up drain pipes (CI drain pipes /PVC/ AC or Reinforced concrete) set in cement mortar (100mm dia), if required complete all as specified and directed. |
| 9 | S&F 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or in trenches or in floor incl neccesary fixing arrangement all as specified and directed. |
| 10 | S&F 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or in trenches or in floor including neccesary fixing arrangement all as specified and directed. |
| 11 | S&F 110 mm bore PVC (SWR) branch piece, single (single Y) equal or unequal all as specified and directed. |
| 12 | S&F 110 mm bore PVC (SWR) branch piece, double (double Y) equal or unequal all as specified and directed. |
| 13 | S&F 75 mm bore PVC (SWR) junction single,(single T) equal or unequal provided with access door all as specified and directed |
| 14 | S&F 110 mm bore PVC (SWR) junction single,(single T) equal or unequal provided with access door all as specified and directed |
| 15 | S&F 75 mm bore PVC (SWR) bends any radius with access door all as specified and directed |
| 16 | S&F 110 mm bore PVC (SWR) bends any radius with access door all as specified and directed |
| 17 | S&F 75 mm bore PVC (SWR) reducer all as specified and directed |
| 18 | S&F 110 mm bore PVC (SWR) reducer all as specified and directed |
| 19 | S&F 75 mm bore PVC (SWR) coupler all as specified and directed |
| 20 | S&F 110 mm bore PVC (SWR) coupler all as specified and directed |
| 21 | S&F 75 mm bore PVC (SWR) vent cowl all as specified and directed |
| 22 | S&F 110 mm bore PVC (SWR) vent cowl all as specified and directed |
| 23 | M&L for 75mm PVC (SWR) floor trap , plain with grating including jointing with solvent cement complete all as spd and directed |
| 24 | M&L for 75mm PVC (SWR) multi floor trap with grating including jointing with solvent cement complete all as spd and directed |
| 25 | M&L for PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement |
| 26 | S & F stack clamp made of 50 mm X 5 mm flat iron and 16 mm dia round iron stay including nut bolts and securing ends of stay to wall or roof suitable for 100 mm bore pipe complete all as specified and directed. |
| 27 | M&L for special treatment to sunken portion (including necessary dismantling of tiles and PCC of any description and thickness alongwith) with 10mm thick plaster in CM 1:4 mixed with and including WPC liquid complast 421 or equivalent as approved by GE and applying one coat each of Nitroproof 100 and Nitroproof 120 or equivalent as approved by GE on plastered surface. Rendering again 10mm thick in CM 1:4 mixed with and including complast 421 in sunken portion of WC and CI pipe joint shall be fitted including filling of lean cement concrete 1:5:10 type E2 complete all as specified and directed |
| 28 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. |
| 29 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match.incl screed bed 15 mm thick in CM 1:4 as bedding layer for floor finishes. |
| 30 | M&L for Glazed ceramic tile coloured in verticle surface such as dado /skirting etc of size 450x300x7/ 350x 250x 7mm/ 350x 250x 7mm thick set and jointed in neat cement slurry and pointed in white and coloured cement to match over and including 10 mm thick rendering in CM 1:4 as backing coat complete all as specified and directed |
| 31 | Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed. |
| 32 | M&L for 75 mm thick Cement concrete Type D2 1:4:8 (40 mm graded graded aggregate) as in sub bases,floor finishes and pavings. |
| 33 | M&L 75mm thick & plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in Plinth protection finished even and fair without using extra cement including necessary formwork complete all as speciifed & directed |
| 34 | S&F in repair Vitreous china wash hand basin (550X400mm) white, flat back excluding taps, including brackets &32mm waste coupling complete all as specifed and directed. |
| 35 | S&F in repair vitreous China squatting pan, Orissa pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) complete all as specified and as directed. |
| 36 | S&F EWC vitreous china wash down water closet pan (pedestal pattern) white (excluding flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flush pipe anti syphonage pipe etc and with plastic water closet seat cover black closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device complete all as specified and as directed. |
| 37 | S&F PVC low level flushing cistern 10 Ltrs capacity with all internal accessories and fixed to wall including provision of PVC flush pipe 32mm dia 90 cm long fixed properly to inlet of EWC/IWC etc complete all as specified and as directed. |
| 38 | S & F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube SS and ABS wall hook including making connections and fixed in position complete in all respect as specified |
| 39 | S & F in repair for 15 mm bore Chromium plated fancy type Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as directed. |
| 40 | S & F pillar tap swan neck type cast copper alloy with capstan heads, chromium plated screwed down high pressure with BF or without lettered Hot or cold with long screwed shanks and flynuts, screwed for union pipe and fixed to 15mm dia pipe. |
| 41 | S & F PVC connection 15mm size with PTMT nuts of length 450mm. |
| 42 | S & F in repair 15mm dia angle valves cast corper alloy screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed. |
| 43 | M&L for 15 mm dia brass CP two way Bib cock with wall flange concealed type screwed down for iron pipe or for unions complete all as directed. |
| 44 | M&L for Demolition of brick or stone masonary built in cement mortar complete |
| 45 | M&L for brick work with sub class B bricks old size straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 including provision of weep holes at every 2m complete all as specified and directed. |
| 46 | Taking dawn cement plaster any description on brick or stone wall/ ceiling including racking out joint, hacking for key and scrubbing down with water etc complete all as specified & directed. |
| 47 | M & L for 15 mm thick rendering in two layers ie.10mm thick backing coat in CM 1:6 and finishing coat 5mm thick in CM 1:4 using water proofing compound on faces of brick masonry wall, finished even and fair etc complete. |
| 48 | Material and labour for two coats of water based permium acrylic smooth exterior emulsion of approved colour with silicon additive & Color stay Technology, Excellent Dirt Pick up resistance with low VOC less than 50 gram / litre as per the LEEDS specifications, Anti Algal properties in two coats not less than 1.79 ltr (undiluted)/ 10 sqm diluted with water as per manufacturer instructions applied over priming coat with fully automatic airless spray machine of paint application with a flow speed of min 1 ltr per minute having a pressure of 3300 PSI. Allow 6-8 hrs to dry the surface in both the coats of paint complete all as specified and directed. |
| 49 | Taking down chowkats or frame n exc 1.5 Sqm each (without taking off shutter from the frame) all as specified and as directed. |
| 50 | Supply and fix Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., all as specified and as directed by Engineer-in-charge |
| 51 | Supply and fix to 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded with 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing all as specified and as directed by Engineer- in-charge |
| 52 | S&F 75mm long SS butt hinges and fixed to frame with scrwewd or welding comlete all as specified and as directed by Engineer- in-charge |
| 53 | S&F 150mm long aluminium anodized barrel tower bolt of extruded section complete. |
| 54 | S&F 100mm long aluminium handle cast type anodized all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 5 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender