Educational and Research Institute Government Departments Closing in 1 days TDR #57333371

Tender For Supply Installation Testing and Commissioning of Vrf / Vrv Type Ac And Split-Wac In Different Locations In Iit Delhi (Accr July 2026)

Issued by Government Departments · Delhi, Delhi
Tender Value
52.56 Lakhs
Estimated cost
Bid Submission
15 Sep 2026
1 days left
EMD
1.05 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Vrf / Vrv Type Ac And Split-Wac In Different Locations In Iit Delhi (Accr July 2026)

BOQ

Name of Work:- SITC of VRF / VRV type AC and Split-WAC in Different Locations in IIT Delhi (ACCR July 2026)
Sl. No. Item Description
1SUB HEAD - 1 (SITC of VRV/VRF AC)
2Supply, Installation, Testing & Commissioning of Modular type Variable Refrigerant Flow (VRF)/Variable Refrigerant Volume (VRV) air cooled Outdoor (Condenser) units suitable for cooling having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in conformation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celsius. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz ac power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio of the unit shall be as per following and complete as per CPWD specification, connections, interconnections etc. as required. Value of ISEER shall not be less than 5.4. (Acceptable make: Any Reputed make)
3For B-3/206 (CARE)
4For B-2/156 (Mechanical)
5Supply, Installation, Testing & Commissioning of mini Variable Refrigerant Flow (VRF)/Variable Refrigerant Volume (VRV) air cooled Outdoor (Condenser) units suitable for cooling having 100% hermetically sealed inverter type twin Rotary/Scroll Compressor(s), minimum two compressors (with individual separate PCB) for above 14 HP modules, microprocessor based Controller, side discharge type condensing unit(s), with R-410-A Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To have better efficiency condenser fan shall be capable to operate at different speed with respect to load. The unit shall deliver the rated capacity and in conformation as per IS 18728:2024 and CPWD Specifications and work even at 50°C ambient temperature without tripping. The system shall be able to deliver 100% of the rated capacity upto 39 Degree Celsius. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz ac power supply and BMS compatible. The unit shall be filled with first charge of the refrigerant and ready for use as required. The condenser should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving overall performance and durability. The Indian Seasonal Energy Efficiency Ratio of the unit shall be as per following and complete as per CPWD specification, connections, interconnections etc. as required. Value of ISEER shall not be less than 5.4. (Acceptable make: Any Reputed make)
6Not less than 5 HP single unit (for MS-730 and B-5/205)
7Supplying, Installation, Testing and Commissioning of following minimum capacity 4 way Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation, Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The Indoor units must have provision to shut down upon receiving a signal from the BMS System/Fire signals. The system shall be capable to adjust air flow as per room requirement in auto mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 degree C DB and 19 degree C WB temperature. (Make will be same as of Outdoor)
81.2 TR
91.6 TR
102.4 TR
11Supplying, Installation, Testing and Commissioning of following minimum capacity High wall type Indoor unit equipped with and comfort washable synthetic media prefilter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The Indoor units must shut down upon receiving a signal from the BMS System/Fire Signals. The system shall be capable to adjust air flow as per room requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 0C DB and 19 0C WB temperature. (Make will be same as of Outdoor)
120.8 TR
132.0 TR
14Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original Equipment Manufacturer (OEM) make as of ODUs and IDUs.
15Indoor Units
16Outdoor Multi Joint
17COPPER REFRIGERANT PIPING: Supplying, Installation, testing and commissioning including vaccumisation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports on ceiling, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
186.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
199.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
2012.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
2115.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
2219 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
2322.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
2428.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm
25GI TRAY SUPPORT: Supplying and installing following size of perforated Hot Dipped Galvanised Iron Cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5% in convenient sections, joined with connectors, suspended / supported from the ceiling / wall with GI suspenders including GI bolts and nuts, GI C-Channels, etc. including bends, reducers, Tees, cross-members as required, GI protective sheet covering (for outdoor portion) outside the room etc. as required.
26150 mm width x 50 mm depth x 1.6 mm thickness
27225 mm width x 50 mm depth x 1.6 mm thickness
28DRAIN PIPE: Supplying and laying of ISI marked UPVC pipe of 32 mm dia for draining of sweated water from AC evaporator (indoor) unit including providing tee, joints, elbows, supports, etc. insulated with XLPE class - O tubular insulation / woth Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 9 mm thick etc. complete as required. (Acceptable make: Any Reputed make)
29DRAIN PIPE: Supplying and laying of ISI marked flexible braided PVC pipe of 25 mm dia for draining of sweated water from AC evaporator (indoor) unit including providing tee, joints, elbows, supports, etc. wherever required etc. complete as required.
30Supplying and fixing DP sheet steel enclosure on surface / recess alongwith 6 A, 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. (Acceptable make: Any Reputed make)
31Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required.
32Making Foundation for Outdoor VRF/VRV unit made of PCC / brick suitable to bear dyanmic load of outdoor unit upto 10 HP including Fabricating, Providing and fixing M.S. iron frame fabricated with M.S. C-channel of size 50 mm x 50 mm x 6 mm (thick) for resting the condenser unit on the floor of duly supported from the bottom as required including painting and grouting the framework with cement concrete etc. complete as required. (Acceptable make: Any Reputed make)
33COMMUNICATION CABLE: Supplying and laying of ISI marked FRLS unarmoured screened copper cable of following size and type and of 1.1 kV grade conforming to IS694:2010 including making connection etc. on surface / cable tray through 20 mm ISI marked medium class PVC conduit complete with bends, couplers, elbows, tees, etc. as required. (Acceptable make: Any Reputed make) [NB: Single stranded cable not to be used]
342 core x 1.5 sqmm
35POWER CABLE (CU): Supplying and laying of ISI marked PVC insulated XPLE armoured copper cable of following size of 1.1 kV grade conforming to IS:7098 on surface / above false ceiling etc. as required. (Acceptable make: Any Reputed make)
364 core x 2.5 sqmm
373 core x 6 sqmm
384 core x 10 sqmm
39Supplying and making end termination with brass compression gland and tinned copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required.
404 core x 2.5 sqmm
413 core x 6 sqmm
424 core x 10 sqmm
43Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
446 Way, Double door
45Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Acceptable make: Any Reputed make)
46Single Pole
47Double pole (as incomer to DB)
48Providing and fixing 4mm dia Copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
49Providing and fixing following rating and breaking capacity 4 pole MCCB with thermomagnetic release as per following and terminal spreaders conforming to IS/IEC 60947-2 & IEC 60947-2 in sheet steel enclosure including drilling holes, duly factory painted as required, making connections, etc. as required. (Acceptable make: Any Reputed make) For main power connection. (Ref SS Enclosure type: L&T Cat No. CM90996OOOO, Size -1)
5040 amp, 25 kA, FPMCCB
5163 amp, 25 kA, FPMCCB
52Supplying and fixing of weather proof non-metallic 4P enclosure on surface / recess with 16/25/32 amp, 415 V, \\"C\\" curve TPN MCB with IP-65 rating complete with connections, testing and commissioning as required. (Reference similar product: Legrand 4 Module Plexo Box for MCB, IP-65) - For outdoor
53SUB HEAD - 2 (SITC of SPLIT & WAC)
54Supply, Installation, Testing and Commissioning of Window type Air conditioners complete with copper power cable upto 3 metre, drain pipe upto 3 metre, wireless Remote including batteries, suitable for working between 180 - 260V with low & high voltage cutoff and 50 hz ,1 phase ac supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / Rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50 dB inside the room is acceptable. The unit shall be in conformation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. The system shall be able to operate up to 50 deg C (out door ambient temperature). Material of evaporator & Condenser : made of Copper.
551.0 TR with Inverter 5 Star BEE rating (Rated cooling capacity: Not less than 3500 watts)
561.5 TR with Inverter 5 Star BEE rating (Rated cooling capacity: Not less than 5000 watts)
57Supplying, Installation, Testing and Commissioning of Air Cooled Cassette type Split Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), R-32/R410A/R-407 Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, 50 Hz ,1 /3 phase AC supply, including surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5.5 Mtr (IDU to ODU), copper power and control cable upto 5.5 Mtr (IDU to ODU) including drain 244 DELHI SCHEDULE OF RATES (E&M)-2025 pipe, the system shall be capable of performing cooling,dehumidification, Air circulation, filtration & ventilation of following capacity with Scroll/rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB) as specified. The system shall be able to deliver 100% of the rated capacity as per relevant IS Code. The lab testing reports as per IS: 1391 shall be submitted from National Accreditation Board for Testing and Calibration Laboratories (NABL) accredited as per International Electrotechnical Commission (IEC) 17025 standards/Central Power Research Institute (CPRI)/ Electrical Research and Development Association (ERDA) with Original Equipment Manufacturer (OEM) etc. complete as per CPWD specification and as per IS: 1391 as required. BEE Rating should be 5 star.(Acceptable make: Any Reputed make)
582.0 TR (for MS 702A)
59Supply, Installation, Testing and Commissioning of Air Cooled Hi-Wall split type Air conditioners complete with Indoor (evaporator) unit (IDU), Out door (condenser) unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 metre (IDU to ODU), copper power cable upto 3.5 metre (IDU to ODU) i/c drain pipe upto 3.5 metre R-32/R-410/ R-407 Green Refrigerant, wireless Remote Controller with batteries, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase ac supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / Rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). The work shall include making suitable opening in the wall / glass for drawing of refrigerant pipes, power connections to indoor and outdoor units, sealing the holes properly on the wall, mending good the damages, etc. including supplying and fixing of prototype adjustable readymade stand made of steel for resting condenser unit either on flat surface or on wall [as per site requirement - either floor mounted or wall mounted], having adequate strength for carrying load of condenser unit, duly prepainted with anticorrosive paint, nuts, bolts, fasteners, grouting / properly securing from accidental fall, fasteners, antivibration pad, including topping up of fresh refrigerant after installation, etc. complete as required. Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615; Material of evaporator & Condenser : made of Copper. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 deg Celsius (out door ambient temperature).
60Inverter type 1.0 TR with 5 Star BEE Rating (Rated cooling capacity: Not less than 3500 watt) for cooling only
61Inverter type 1.5 TR with 5 Star BEE Rating (Rated cooling capacity: Not less than 5000 watt) for cooling only
62Inverter type 2.0 TR with 5 Star BEE Rating (Rated cooling capacity: Not less than 6000 watt) for cooling only
63Supplying and laying of ISI marked FRLS industrial multistranded copper flexible cable of following size and type and of 1.1 kv grade conforming to IS694:2010 including making connection etc. for communication / indoor power supply between indoor and outdoor unit and other units, etc. as required. (Acceptable make: Any reputed make) [NB: Single stranded cable not to be used]
644 core x 2.5 sqmm unarmoured Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57333371
AUTHORITY Government Departments
TENDER VALUE 52.56 Lakhs
LAST DATE 15-09-2026
Authority
Authority Name Indian Institute Of Technology
Work Description Tender for Supply Installation Testing and Commissioning of Vrf / Vrv Type Ac And Split-Wac In Different Locations In Iit Delhi (Accr July 2026)
Basic Detail
Tender No IITD/WORKS (SP-5393)/2026
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 03 Sep 2026
Submission Date 15 Sep 2026
Open Date 16 Sep 2026
Finance
Tender Value 52.56 Lakhs
Tender Fee Ref. Documents
EMD 1.05 Lakhs
Exemption Not Available
Document List
25693719-15ee-4da2-90c3-2451a7e275eb.html
BOQ_971797.xls
Tendernotice_1 (8).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 15, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Sep 16, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

25693719-15ee-4da2-90c3-2451a7e275eb.html

xls

BOQ_971797.xls

pdf

Tendernotice_1 (8).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders