Drinking Water Supply and Sanitation Government Departments Closing in 6 days TDR #57330511

Tender For Supplying, Erection, Testing And Commissioning Of Horizontal Split Casing (Hsc) Centrifugal Pumpsets And Its Allied Works At Vyasarpadi Water Distribution Station Area-Iv

Issued by Government Departments · Chennai, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
22 Sep 2026
6 days left
EMD
2.03 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supplying, Erection, Testing And Commissioning Of Horizontal Split Casing (Hsc) Centrifugal Pumpsets And Its Allied Works At Vyasarpadi Water Distribution Station Area-Iv

BOQ

Name of Work:- Supplying, Erection, Testing and Commissioning of Horizontal Split Casing (HSC) Centrifugal pumpsets and its allied works at Vyasarpadi Water Distribution Station Area-IV
Sl. No. Item Description
1Horizontal Split casing Centrifugal pumpsets
2Supply and delivery of AC three Phase 4 pole Horizontal squirrel cage Induction motor confirm ing to IS 325/1996 and as amended thereafter with Class F insulation to suit the speed of pump and suitable for operation with continuous S1 rated, 415 V +/- 10 %, 50 HZ +/- 5%, TEFC (upto 20 HP), SPDP (above 20 HP). The motor offered should be of energy efficient motors.(220KW- 300HP).
3Supply and delivery of Horizontal split casing centrifugal pump conforming to IS 1520 and as amended thereafter with CI casing and split glands, stainless steel shaft, hydraulically and dynamically balanced bronze impellers capable of discharging required quantity of water against a total head noted below due to all causes and with the accessories such as G.M air release cock, Grease cup, G.I priming funnel, M.S lifting hook, drip water G.I pipe connections, leading to the outside of pump house rubber water deflector, double flap foot valve, G.M strainer including unique tyre type coupling, common M.S fabricated base to mount pump and motor and other standard fittings etc complete. Pump shall be capable of discharging the specified quantity at the head noted at the minimum NPSH at site conditions. The shut off head shall be atleast 25% over and above the head at duty point. The pump shall be suitable for operation in AC three phase, 415 V, 50 Hz, 1500 RPM. ( Flow: 32,700 LPM, Head 36 Meters)
4Supply, delivery and installation of Variable Frequencty Drive with IP65 Enclosure Model FC302. Horizintal Centrifugal Pumpset including Control panel and cable adopter box with following specifications:Fuse unit 800A, 2A single pole MCB, ON/OFF indication lamp and trip indication lamp of 230V AC-3 nos, CT disconnector terminal block - 4 nos, 6A double pole MCB 10KA - 2nos, 6A single pole MCB 10KA - 1 no, 9A power contactor - 1no, push button - 2 nos, 6\\" cooling fan - 2 nos, 6\\" air filter - 2nos. The Panel technical specification includes rated operation voltage of 415V AC, rated insulation voltage of 1100V AC +/-10% voltage variation, rated frequency of 50Hz. IP54 degree of protection, floor mounting, control wiring of 1.5sqmm copper cables as per specification required in the site etc., complete for motors 320HP - 350HP
5Supplying & laying of 3½ core 300 sq.mm. LTUG cable in a trench to be excavated at a depth of 2½' putting 6” layer of sand and covering the cable with brick and sand refilling the earth to make good
6Supplying and fixing of cable gland and termination with Aluminium cable by 3½ core 300 sq mm PVC UG cable and with earth connection
7Dismantling the existing pump set including motor, base frame and accessories
8C.I. D/F Reflux (Non-Return) Valve as per IS 5312:2004 (Part I), PN-1,600mm with bypass arrangement, ISI marked and 5 years warranty.
9600mm CI sluice valves non raising spindle types to pressure rating of 1.6 PN to be used in pump houses (long body/ long face to Face) conforming to IS and with 5 years warranty
10Supply,delivery, erection, testing and commissioning of electrically operarated actuator
11Fabrication and fixing of 600mm dia M.S dismantling joint with 3 nos of IS standard flanges welded & 1no free flange including cost of material, Making flange holes, Rolling, welding, machining, FRB coating, \\"O\\" ring etc complete as per site condition as directed by the Engineer-in-Charge.
12Cement concrete1:3:6 using Crushed stones and (M sand) and 40mm gauge hard broken stone jelly for plain cement concrete works including laying in layers of not more than 15cm thick including ramming curing, etc.,complete
13Stock brick work with II class bricks in cement mortar1:3(Crushed stones and (M-sand)) for over 23 cm thick wall including curing etc. complete
14Plastering with cement mortar 1:3 (Crushed stone sand (M-sand)) for 15mm thick including curing, etc., complete.
15Painting two coats with approved cement paint over one coat of cement paint over cement plastered wall surface, ceiling including cleaning preparing the surface and curing, etc., complete
16Pump for filling point
17Supply, installation, testing and commissioning of Vertical Openwell Submersible Pumpset of approved make (Kirloskar/EKKI/KSB/CRI or equivalent), capable of delivering 100 m³/hr against a Total Dynamic Head (TDH) of 30 metres, driven by a suitable 3-phase, 415 V, 50 Hz squirrel cage induction motor with Variable Frequency Drive (VFD), complete with pump, motor, VFD control panel, non-return valve, sluice/butterfly valve, pressure gauge, delivery piping connections, power cable, cable glands, lugs, earthing, all necessary accessories, erection, alignment, testing, trial run and commissioning, including all labour, tools, tackles and incidental charges, complete as directed by the Engineer-in-Charge.Duty PointDischarge (Q): 100 m³/hrTotal Dynamic Head (TDH): 30 mPower Supply: 415 V, 3 Phase, 50 HzMotor Rating: Suitable HP as per manufacturer's selection (approximately 30 HP).
183 Core × 50 sq.mm, 1.1 kV Grade, Armoured Aluminium Conductor, XLPE Insulated, PVC Sheathed Cable conforming to IS 7098 (Part I) with ISI marking.( LT Cables )
19Light and fans
20Supply, delivery and erection of Three Phase 12 way, LDB with the following:1 No of 63 A FP isolator for incoming supply3 Nos. of 40A, 30mA, DP RCBO18 Nos.of 10 / 16A, SP MCBin sheet steel enclosure fitted with busbars and neutral links and suitable angle iron frame works with provision for earthing etc. complete
21Run of 2 of 2.5 sq.mm. PVC unsheathed copper SC cable in PVC pipe for mains with continuous earth connection by 14SWG TC wire
22a) Wiring with 2.5 sq.mm. PVC unsheathed copper SC cable in suitable PVC rigid pipe concealed for lights TW box switches and joint boxes with continuous earth connection by 14 SWG TC wire
23b) Wiring with 2.5 sq.mm PVC unsheathed coppe single core cable in suitable conduit pipe for fans with 5 amps single pole switch M joint box and MS switch box in flush with all and covered with PVC sheet of 3mm thick with continuous earthwire connection by 14 SWG Tinned copper wire
24Wiring with 2.5 sq.mm. PVC unsheathed SC copper cable on suitable rigid PVC pipe for 5A 3pin CS plugn on interlocking including S&F plug pin top inTW box with continuous earth connection by 14 SWG TC wire
25Supplying and fixing of surface mount 18-22W LED light fitting
26Supplying and fixing of ceiling fixture with gallery complete (Indian type suitable for 60W bulb (Adopting LED bulbs in place of incandescent lamps )
27Supplying and fixing of 12” sweep AC exhaust fan complete including providing necessary opening in the wall
28Supplying and fixing of 48” sweep AC ceiling fan complete with regulator with 1m down rod (steampipe) including supplying and fixing of fan clamp with side plates and cross arm
29Supplying & laying of 4 core 16 sq.mm LTUG cable in a trench to be excavated at a depth of 2½' putting 6” layer of sand and covering the cable with brick and sand refilling the earth to make good
30Supply and fixing of cable gland and lamination with Aluminium cable by 2 core 10 Sqmm LTUG cable and with earth connection.
31Supplying and clam ping of 2 core 4sq.mm.PVC LTUG cableby MS clamps on wall
32Suppling and fixing of cable gland and termination with earth connection for 2 core 4 sq.mm
33GI STEEL TUBULAR POLE FOR STREET LIGHT with 6 Metre Length Double Bracket Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 6000mm Length
34Supply and fixing of 80W LED Focus Light Fitting with LED
35Supply and fixing of 150W LED Industrial type High bay light fitting
36Sub Total (excluding GST)
37GST @18% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57330511
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 22-09-2026
Authority
Authority Name Chennai Metropolitan Water Supply And Sewerage Board
Work Description Tender for Supplying, Erection, Testing And Commissioning Of Horizontal Split Casing (Hsc) Centrifugal Pumpsets And Its Allied Works At Vyasarpadi Water Distribution Station Area-Iv
Basic Detail
Tender No CNT/WSS/MWB/3776/2026-27
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 03 Sep 2026
Submission Date 22 Sep 2026
Open Date 23 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 2.03 Lakhs
Exemption Not Available
Document List
8b3adfa1-59f0-4200-a3e2-4c1d0d4dd464.html
BOQ_842512.xls
CHECK_LIST_3776.pdf
Tendernotice_1 (14).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 23, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

8b3adfa1-59f0-4200-a3e2-4c1d0d4dd464.html

xls

BOQ_842512.xls

pdf

CHECK_LIST_3776.pdf

pdf

Tendernotice_1 (14).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders