Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Bsnl Edbg Nit No 26 Providing Electrical Works For Extending Supply To Vendor Equipment At Room 608 6Th Floor Ntb Bengaluru For Conducting Poc; Elec
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Bsnl Edbg Nit No 26 Providing Electrical Works For Extending Supply To Vendor Equipment At Room 608 6Th Floor Ntb Bengaluru For Conducting Poc; Electrical System Or Inst.. - Supplying And Fixing Of 28W 1150Mm Metal Body Led Batten Light Fitting Suitable For Operation On 230V 50Hz Ac Supply Including Interconnection Testing And Commissioning Etc As Required Ms Crompton Philips Or Similar Superior Make , Supplying And Drawing 3X4.0 Sqmm Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Drawing 3X6 Sqmm Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface/ Recessed Steel/ Pvc Conduit As Required. , Supplying And Fixing Of 20Mm Dia Pvc Flexible Conduit Along With Accessories On Surface As Required , Supplying And Fixing Of 25Mm Dia Medium Class Pvc Conduit Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required , Supplying And Fixing Of Following Size Upvc Trunk Box (Cable Management) System On The Surface Of Wall / Floor / Ceiling / On The The Existing Cable Tray With Necessary Connected Accessories Like Bends, Elbows, Tee, Etc As Required. [Make Mk India / Lk Or Any Similar Superior Make] (A) 50 Mm X 50Mm , (B) 100Mm X 50Mm , Supplying And Fixing Following Size Modular Pvc Box With Base And Cover Plate On Existing Wall/Table Etc. As Required. (M/S Anchor Roma Or Similar Superior Make) (A) 6 Module , Supplying & Fixing Of Following Modular Switches, Sockets Suitable Of Working On 230V, Single Phase Ac Supply Etc, As Reqd (Modular Switches M/S Roma Or Superior Make) A) 20 A 1 Way Modular Switch With Indicator , (B) 16A 3Pin Modular Socket Out Let , Supplying And Fixing 4Way, Double Door Single Pole And Neutral, Sheet Steel, Mcb Distribution Board, 240V, On Surface/ Recess, Complete With Tinned Copper Bus Bar, Neutral Bus Bar, Earth Bar, Din Bar, Interconnections, Powder Painted Including Earthing Etc. As Required. (But Without Mcb/Rccb/Isolator) , Supplying And Fixing Single Pole 5 A To 32 A Rating, 240V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Supplying And Fixing Double Pole 5 A To 32 A Rating, 240V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. , Rearranging The Existing Ups/Raw Power/Ac Units Supply Wiring In Room No 608, Tracing The Wiring In Existing Floor Trunk, Disconnecting The Unused Wires, Bunching The Wires In Existing Trunk, Connections Etc As Required
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Supplying and fixing of 28W 1150mm metal body LED batten light fitting suitable for operation on 230V 50hz AC supply including interconnection testing and commissioning etc as required Ms Crompton Philips or similar superior make | Supplying and fixing of 28W 1150mm metal body LED batten light fitting suitable for operation on 230V 50hz AC supply including interconnection testing and commissioning etc as required Ms Crompton Philips or similar superior make |
| 2 | Supplying and drawing 3x4.0 sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | Supplying and drawing 3x4.0 sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 3 | Supplying and drawing 3x6 sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | Supplying and drawing 3x6 sqmm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 4 | Supplying and fixing of 20mm dia PVC flexible conduit along with accessories on surface as required | Supplying and fixing of 20mm dia PVC flexible conduit along with accessories on surface as required |
| 5 | Supplying and fixing of 25mm dia medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required | Supplying and fixing of 25mm dia medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required |
| 6 | Supplying and Fixing of following size uPVC trunk box (cable management) system on the surface of wall / floor / ceiling / on the the existing cable tray with necessary connected accessories like bends, Elbows, Tee, etc as required. [Make MK India / LK or any Similar Superior Make] (a) 50 mm x 50mm | Supplying and Fixing of following size uPVC trunk box (cable management) system on the surface of wall / floor / ceiling / on the the existing cable tray with necessary connected accessories like bends, Elbows, Tee, etc as required. [Make MK India / LK or any Similar Superior Make] (a) 50 mm x 50mm |
| 7 | (b) 100mm x 50mm | (b) 100mm x 50mm |
| 8 | Supplying and fixing following size modular PVC box with base and cover plate on existing wall/table etc. as required. (M/s Anchor ROMA or Similar Superior Make) (a) 6 Module | Supplying and fixing following size modular PVC box with base and cover plate on existing wall/table etc. as required. (M/s Anchor ROMA or Similar Superior Make) (a) 6 Module |
| 9 | Supplying & fixing of following modular switches, sockets suitable of working on 230V, Single phase AC supply etc, as reqd (Modular switches M/s ROMA or superior make) a) 20 A 1 way Modular switch with indicator | Supplying & fixing of following modular switches, sockets suitable of working on 230V, Single phase AC supply etc, as reqd (Modular switches M/s ROMA or superior make) a) 20 A 1 way Modular switch with indicator |
| 10 | (b) 16A 3pin Modular socket out let | (b) 16A 3pin Modular socket out let |
| 11 | Supplying and fixing 4WAY, DOUBLE DOOR SINGLE pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | Supplying and fixing 4WAY, DOUBLE DOOR SINGLE pole and neutral, sheet steel, MCB distribution board, 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 12 | Supplying and fixing SINGLE POLE 5 A to 32 A rating, 240V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required. | Supplying and fixing SINGLE POLE 5 A to 32 A rating, 240V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 13 | Supplying and fixing DOUBLE POLE 5 A to 32 A rating, 240V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required. | Supplying and fixing DOUBLE POLE 5 A to 32 A rating, 240V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 14 | Rearranging the existing UPS/RAW Power/AC units supply wiring in Room no 608, tracing the wiring in existing floor trunk, disconnecting the unused wires, bunching the wires in existing trunk, connections etc as required | Rearranging the existing UPS/RAW Power/AC units supply wiring in Room no 608, tracing the wiring in existing floor trunk, disconnecting the unused wires, bunching the wires in existing trunk, connections etc as required |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender