Tender For Repair/ Replacement Of Water Service Tank, Cleaning Of Sumps & Oh Tanks And Water Supply Distribution System And Other Connected Works At Af Stn Leh
Tender Value
10 Lakhs
Estimated cost
Bid Submission
24 Sep 2026
4 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Leh → Ladakh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Replacement Of Water Service Tank, Cleaning Of Sumps & Oh Tanks And Water Supply Distribution System And Other Connected Works At Af Stn Leh
BOQ
| Sl. No. | Item Description |
| 1 | M&L for cleaning of insulated steel overhead tanks of 50,000 ltrs capacity by adopting following method :-(a) Removing accumulated sludge and solid particles etc deposited at the bottom of tank and removing the same to a distance not exceeding 50 mtr away complete all as specified and directed by Engr-in-Charge.(b) Fabrication & welding work with the specified size of MS plain sheet and angle iron to steel tank to stop leakages complete all as directed by Engr-in-charge.(c) Washing with clean water bleaching powder solution by rubbing with wire brush on all side walls and bottom of the tank and removing grits and other deposited materials complete inside, outside of the tank and applying two coats of water bond distemper making it absolutely germ free complete all as specified and directed by Engr-in-Charge. |
| 2 | All as per item no. 1 above but 30,000 Ltr capacity |
| 3 | All as per item no. 1 above but 25,000 Ltr capacity |
| 4 | M&L for cleaning of under ground/ semi underground sumps of 1,00,000 ltrs capacity by adopting following method :-(a) Taking out the water from the sump with the help of monoblock/submersible pump set and removing accumulated sludge and solid particles etc. deposited at the bottom of sump and removing the same to a distance not exc 50 meter away complete all as specified.(b) Washing with clean water bleaching powder solution by rubbing with wire brush on all side walls, dome portion and bottom of the tank and removing grits and other deposited materials complete inside and from the outside of sump and wash with two coat of cement wash, plastering internally with 15mm thick in cement mortar 1:6 & flush pointing externally in the same mortar. (applying two coats of water bound distemper making it absolutely germ free) complete all as specified and dircted by Engr-in-Charge. |
| 5 | M&L for cleaning of Static water tank sumps by adopting following method :-(a) Taking out the water from the sump with the help of monoblock/submersible pump set and removing accumulated sludge and solid particles etc. deposited at the bottom of sump and removing the same to a distance not exc 50 meter away complete all as specified.(b) Washing with clean water bleaching powder solution by rubbing with wire brush on all side walls, dome portion and bottom of the tank and removing grits and other deposited materials complete inside and from the outside of sump and wash with two coat of cement wash, plastering internally with 15mm thick in cement mortar 1:6 & flush pointing externally in the same mortar. (applying two coats of water bound distemper making it absolutely germ free) complete all as specified and dircted by Engr-in-Charge. |
| 6 | M&L for cleaning of overhead tanks of 10,000 ltrs capacity by adopting following method :-(a) Removing accumulated sludge and solid particles etc deposited at the bottom of tank and removing the same to a distance not exceeding 50 mtr away complete all as specified.(b) Washing with clean water bleaching powder solution by rubbing with wire brush on all side walls, dome portion and bottom of the tank and removing grits and other deposted materials complete inside and from the outside of the tank, plastering internally wtih 15mm thick in cement mortar 1:6 & flush pointing externally in the same mortar to stop leakages (applying two coats of water bound distemper making it absolutely germ free) complete all as specified and dircted by Engr-in-Charge. |
| 7 | M&L for painting to steel ladder all along the overhead tank approx 15 mtr high, painting to staging and overhead tank of capacity 50000 ltrs by applying two coats of primer and top coating with synthetic enamel paint black inlcuding preparation of old painted surfaces and writing \\"Tank cleaned on the date\\" and next due date with white paint complete on the base of black paint all as directed by Engr-in -Charge. |
| 8 | All as per item no. above but 30,000 ltrs capacity |
| 9 | All as per item no. above but 25,000 ltrs capacity |
| 10 | M&L applying two coats of white wash to overhead tank of capacity 10000 Ltrs including preparation of old surface and writing \\"Tank cleaned on the date\\" and next due date with white paint complete on the base of black paint complete all as directed by Engr-in-Charge. |
| 11 | M&L applying two coats of white wash to underground/semi underground/ static water tank sump including preparation of old surface and writing \\"Tank cleaned on the date and next due date \\"in white with synthetic enamel paint complete on the base of black paint complete all as directed by Engr-in-charge. |
| 12 | S&F in repair Ball brass valve, high pressure with polythene float and fly nut complete ISI marked of size 15mm complete all as specified and directed by Engr-in-charge. |
| 13 | S&F in repair Ball brass valve, high pressure with polythene float and fly nut complete ISI marked of size 20mm complete all as specified and directed by Engr-in-charge. |
| 14 | S&F in repair Ball brass valve, high pressure with polythene float and fly nut complete ISI marked of size 25mm complete all as specified and directed by Engr-in-charge. |
| 15 | Disconnecting existing tanks of size 300 Ltrs to 500 Ltrs setting aside (for lowering ) and cleaning of all scaling all dirt etc. Hoisting reconnecting and refixing in position including preparation of old painted surfaces complete all as directed by Engr-in-charge. |
| 16 | Disconnecting existing tanks of size 1000 Ltrs on the ground (for lowering) and cleaning of all scaling all dirt etc. Hoisting reconnecting and refixing in position including preparation of old painted surfaces complete all as directed by Engr-in-charge. |
| 17 | Supply and fixed in repair Gun-metal, globe or gate valves, 15 mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified & directed by Engr-in-Charge. |
| 18 | Supply and fixed in repair Gun-metal, globe or gate valves, 20 mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified & directed by Engr-in-Charge. |
| 19 | Supply and fixed in repair Gun-metal, globe or gate valves, 25 mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified & directed by Engr-in-Charge. |
| 20 | Supply and fixed in repair Gun-metal, globe or gate valves, 40 mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified & directed by Engr-in-Charge. |
| 21 | Supply and fixed in repair Gun-metal, globe or gate valves, 50 mm dia , heavy duty, with iron wheel head, screwed both ends (ISI marked), complete all as specified & directed by Engr-in-Charge. |
| 22 | Supply and fixed in repair cast iron sluice valve ISI marked 80 mm dia class PN 1.6 flanged with gun metal spindle including all fittings such as nuts , bolts, washers tec with iron wheel confirming to IS: 780/14846 complete in all respect all as specified. |
| 23 | Labour for Cleaning drain pits by removing the waste materials (soil) to a distance exceeding 50 m and depositing where directed at a level not exc 1.5 m above the starting point, making all good of drains for easy draining the pits in winter complete all as specified and directedby engr-in-charge. |
| 24 | M&L for collecting the water sample from the pump house and sending to the laboratory Approved by Govt for testing of the water including chemical analysis as PH value,Turbidity,Mineral Test,Residual test on the interval of 6 Month in a year conforming to IS:3025, IS:10500-2012 complete all as specified and directed. |
| 25 | M &L for Repair to existing valve pit of internal size (120cm x 120cm x 120 cm), with resetting the stones with cement mortar 1:6 including relastering, recoping with PCC 12:4 type B-1 (using 20mm graded stone aggregate), welding of hinges with angle iron frame bringing the bended MS sheet into flat shape etc complee ass as specified and as directed by Engr-in-Charge. |
| 26 | M &L for Repair to existing valve pit of internal size (150cm x 150cm x 150 cm), with resetting the stones with cement mortar 1:6 including relastering, recoping with PCC 12:4 type B-1 (using 20mm graded stone aggregate), welding of hinges with angle iron frame bringing the bended MS sheet into flat shape etc complee ass as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
| 27 | M &L for Repair to existing valve pit of internal size (150cm x 150cm x 150 cm), with resetting the stones with cement mortar 1:6 including relastering, recoping with PCC 12:4 type B-1 (using 20mm graded stone aggregate), welding of hinges with angle iron frame bringing the bended MS sheet into flat shape etc complee ass as specified and as directed by Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 26, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer