Public Administrative Department Local Bodies Closing in 14 days TDR #57328168

Tender For Composite Work For Establishment Of Electrical, Civil, Fire And It Infrastructure For Scada Disaster Recovery Centre At 66/11 Kv Ess B.D Marg.

Issued by Local Bodies · New Delhi, Delhi
Tender Value
2.64 Crore
Estimated cost
Bid Submission
13 Oct 2026
14 days left
EMD
5.29 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Composite Work For Establishment Of Electrical, Civil, Fire And It Infrastructure For Scada Disaster Recovery Centre At 66/11 Kv Ess B.D Marg.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 24-Sep-2026 Extension of date Date 13-Oct-2026

BOQ

Name of Work:- Composite work for Establishment of Electrical, Civil, Fire and IT Infrastructure for SCADA Disaster Recovery Centre at 66/11 kV ESS B.D Marg.
Sl. No. Item Description
1Part -B: (Major component:Supply, Installation, Testing & Commissioning of Electrical Infrastructure) Supply, Installation, Testing & Commissioning of LT Panel Board in two sections for SCADA Disaster Recovery Centre. Complete in all respect as per technical specification mentioned in Annexure TS-1
2Supply, Installation, Testing & Commissioning of 3 Phase, 415V, 50Hz, 125kVA rating CPCB IV compliant DG Set having inbuilt fuel supply system and separate AMF Panel including following:-(a) Casting of M-20 Grade cement & concreate foundation for installation of supplied DG-Set & AMF Panel.(b) Establishment of dedicated Earth grid of copper material for connection of neutral earthing of alternator of DG-sat through cooper earth strip of appropriate size.(c) Establishment of dedicated Earth grid of GI material for connection of body earthing of DG-sat through GI earthing strip of appropriate size.Detailed specification is provided in Annexure TS-2
3Supply of Earth Grid material for maintenance free and water less earth grid to deliver earth result not exceeding 02 Ohms, consisting of earth electrode (s), Earth Strip and hardware for interconnection of earth electrodes, earth enhancing material (conductive concrete), complete in all respect and as per Technical Specification Prescribed at Annexure-TS-3
4Supply of Copper bonded MS strip having size 50X6 mm for connection of earthing from earth grid to equipment, as per Technical Specification prescribed at Annexure-TS-3
5Supply of 65 mm size, medium class GI pipe
6Establishment of maintenance free and water less earth grid as per design of individual site, consisting following:-(i) Making of number (s) of vertical bore of dia and depth mentioned in design and embedding pre casted earth electrode (s) in bore (s)(ii) Interconnection of earth electrode (s) by jointing earth strip with stainless steel nut & bolts. Joint shall be treated with hot solder to make jointing air free gap.(iii) After placing the pre-casted earth electrode (s) in vertical bore (s), rest of the space of vertical bore (s) shall be filled by earth enhancing (conductive concrete) material in slurry form.
7Laying of 50X6 mm copper bonded strip at 0.50 meter below ground level/surface/in recess including connections/jointing to connect equipment with earth grid.
8Laying of 65mm size GI pipe horizontally at 0.5 meter below ground level/across the passage/wall/floor and vertically in recess/surface and drawing of 50X6 mm copper bonded strip through it for earthing.
9Supplying ,Installation, Testing and Commissioning 415V 3 Phase 50Hz High Performance Precision A.C of 2 Ton Rating with humidity control arrangement and Necessary Ducting fabricated from GI Sheet suitable to deliver/suction of Air from dedicated point, as per requirement of SCADA server of disaster Recovery centre.Precision Air conditioning system should be capable for round the clock functioning without any interruption.Operational Logic: Two PAC shall constitute one unit. The unit operation logic shall be such that one PAC of the unit shall operate for defined number of hours and other PAC of the unit will be in standby mode. The standby unit will come in operation after set hours. If any issue/Alarm comes in the active unit then stand by unit should take over the control and becomes active until the issue in the other unit is resolved. Switching should happen automatically without any user intervention. The other unit of Two precision A.C shall operate in same sequence as explained above.Detailed Technical specification is enclosed at Annexure-TS-4
10Supplying , Installation, Testing and Commissioning of Air Cooled Inverter Type - Hot & Cold 1.5 TR with 3 Star BEE Rating High Wall split type Air conditioners complete with Indoor unit (IDU), Outdoor unit (ODU),surface/concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll/rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5-year Original Equipment manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply: Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS:1391 Part II 2023. The system shall be able to operate up to 50 0C (outdoor ambient temperature).
11Supply, Installation, Testing and Commissioning of 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
12Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable etc. as required.
13Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note: More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
14Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 22 watt LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P.F.≥0.95, IP20,CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry),of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends,CCT 3000°K/4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching)<3,Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty.System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.(Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
15Supply Installation, Testing and Commissioning of 15 inch sweep exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc.Complete in all respect as required at site.
16Supply Installation, Testing and Commissioning of 16 inch sweep wall mounted fan including connection with 2 core copper conductor flexible wire drawn through PVC Flexible pipe etc. complete in all respect as required at site.
17Powder coated die cast /Extruded aluminium Body 22 watt LED Panel light 2x2 ft., (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching) required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
18Supplying and fixing of Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board 4 way (4 + 12), of sheet steel, dust protected, duly powder painted, inclusive of 200A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .
19Supplying and fixing Cable End Box (Loose Wire Box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc. as required.
20Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).
21Supplying and fixing Cable End Box (Loose Wire Box) suitable for 4 way, Double door triple pole and neutral (TPN MCBDB ), sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required.
22Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. 125 A,36KA,FPMCCB
23Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. 200 A,36KA,FPMCCB
24Supplying and fixing 5 A to 32 A rating single pole & neutral, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
25Supplying and fixing 5 A to 32 A rating single pole, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
26Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
27Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group B
28Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
29Supplying and fixing 15/16A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
30Supplying and fixing 6 pin 15/16A modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
31Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
32Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
33Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm)
34Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 12 Module (200mmX150mm)
35Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
36Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
37Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
38Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
39Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
40Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 4 sq. mm + 2 X 4 sq. mm earth wire
41Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
42Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
43Wiring for light/ power plug with 2X4 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
44Supply of 1.1 Kv grade Aluminium conductor,XLPE Insulated,outer PVC sheated, armour power cable of size185sq x 3.5Core as per Technical Specifications provided in Annexure TS-5
45Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of185Sqmm/3.5 C size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
46Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of 185 Samm/3C in the existing RCC/ HUME/ METAL pipe as required.
47Handling of LT Cable-185 mm²/3½C which are not necessarily laid in ground but part of it going up to pole/panel/pillar & part in the building in open trench/pillar/panel or otherwise.
48Road Cut of any thickness (Metalled/Concrete) for one cable . Road berm/stone footpath/ brick footpath/CC Slab/approach Gat
49Supplying & Laying of 110 mm dia. (O.D ) HDPE pipes ISI marked PN-4 Class of following sizes by trench less technology across in various roads service road/main gate in NDMC area.
50Supplying and making end termination for L.T. XLPE 1.1 KV cable of size 185 sq.mm/3.5 C. [ MAKE : 3M / Cabseal / Raychem ]
51Sub Part C-1 (Minor Component: Supply, Installation, Testing & Commissioning of IT Infrastructure ) Desktop Computers and its Accessories (All in One)
52Data Points
53IP Phone + IPAX
54IPBAX for IP Phone
55Network Rack
56Wifi Router
57Personal Printers
58Common Printers
59Access Controlled Door Lock
60Video Conferencing System
61Lease Line Cost for 100 Mbps for 03 Years at DC Center
62Sub Part C-2 (Minor Component: Supply, Installation, Testing & Commissioning of Fire Infrastructure ) P/F/T/C of Mild Steel Black Pipe IS:1239 (Part I) C-class including cutting, screwing, welding etc. and providing i.e. flanges, bends, tees, elbows, reducers, chilly clamps, dash fastner hanger, M.S. angles for support of pipes etc. including cutting holes and chases in bricks/core cutting in RCC wall/slab and making the same good including providing coat of steel primer and two or more coats of synthetic enamel paint of approved quality & shade to the entire satisfaction of Fire Officer. The measurement of pipe upto the level finish MS Pipe in the elbow. 25 mm dia
63P/F/T/C of Mild Steel Black Pipe IS:1239 (Part I) C-class including cutting, screwing, welding etc. and providing i.e. flanges, bends, tees, elbows, reducers, chilly clamps, dash fastner hanger, M.S. angles for support of pipes etc. including cutting holes and chases in bricks/core cutting in RCC wall/slab and making the same good including providing coat of steel primer and two or more coats of synthetic enamel paint of approved quality & shade to the entire satisfaction of Fire Officer. The measurement of pipe upto the level finish MS Pipe in the elbow. 100 mm dia
64P/F/T/C of Mild Steel Black Pipe IS:1239 (Part I) C-class including cutting, screwing, welding etc. and providing i.e. flanges, bends, tees, elbows, reducers, chilly clamps, dash fastner hanger, M.S. angles for support of pipes etc. including cutting holes and chases in bricks/core cutting in RCC wall/slab and making the same good including providing coat of steel primer and two or more coats of synthetic enamel paint of approved quality & shade to the entire satisfaction of Fire Officer. The measurement of pipe upto the level finish MS Pipe in the elbow. 150 mm dia
65Supplying and fixing of fire brigade connection of cast iron body with gun metal male intantaneous intel coupling complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required2 way-100 mm dia M.S.Pipe
66P/F/T/C of Fire Cabinet fabricated from 16 SWG M.S. Sheet with front double door opening including fixing/welding BRC fabric of size 25 x 25 mm of 12 SWG in door opening as well as providing 4 mm thick glass sheet of required size. The cabinet may be suitable to accommodate two way/one way landing valve one No. hose reel, two No. 15 metre long RRL delivery hose pipe and two No. branch pipe and providing godown lock and necessary locking arrangement complete including painting with a coat of steel primer and two or more coat of synthetic enamel paint of approved quality and shade to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.2100 x 900 x 600 mm
67Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless Steel (Grade 304)
68Supplying & fixing 63 mm dia Stainless Steel short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required.Stainless Steel (Grade 304)
69Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS:12585.20 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 M Long
70P/F/T/C/ of Forzed Brass Ball Valve screwed type of approved quality complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge. 25 mm dia
71Supplying, Testing and Commissioning of CO2 type Fire Extinguisher ISI marked conforming to IS: 15683:2018 of Capacity 4.5 Kg. complete with delivery hose horn, squeeze grip/ wheel type release valve, locking arrangement, operation manual and bracket. Operating Temperature: - 30ºC to + 60ºC etc. complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.
72Supplying, Testing and Commissioning of Water Fire Extinguisher (Stored Pressure) Capacity 09 Litre duly ISI marked conforming to IS: 15683. Complete with delivery hose, squeeze grip release valve, locking arrangement, pressure gauge, operation manual and bracket. Operating Temperature: +5ºC to + 60ºC etc. complete in all respect to the entire satisfaction of Fire Officer.
73Supplying, Testing and Commissioning of Powder Fire Extinguisher (Stored Pressure type) Capacity 06 Kg duly ISI marked conforming to IS: 15683:2006, with IS 4308, ISI marked ABC powder complete with squeeze grip release valve, discharge pipe, locking arrangement, pressure gauge, operation manual and bracket. Operating Temperature: -30ºC to + 60ºC etc. complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.
74Providing and Fixing of Egress Edgelit light having 2-3 Hours backup on battery (Safety Sign Boards Single sided and Double Sided) complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge. Single Sided
75Providing and Fixing of Egress Edgelit light having 2-3 Hours backup on battery (Safety Sign Boards Single sided and Double Sided) complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge. Double sided
76Providing and Fixing of Emergency Light providing through 16Watt Twin UL Listed High Intensity LED fitted Lamps with Adjustable Swivel Type Beam Lights fitted upon Powder Coated CRCA/MS Sheet Sleek Electronic Cabinet with Customized Signage fitted with 12V, 7AH SMF Battery giving Battery Backup of Upto 5 Hours provided with feature of Trickle Charging facilitating Overcharging and Low Battery Protection. 4 nos. UL certified Dual Tone LEDs with CRI Index greater than 90 provide maximum Smoke Penetration from each Lamp. Certificate of UL listed LED used are provided with each unit of Emergency Light. Electrical Supply is suitable for 230V 50Hz AC fitted with Fuse safety etc. complete in all respect to the entire satisfaction of Fire Officer.
77Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 100 mm dia
78P/F/T/C of following size of 1.1 KV grade multicore Copper conductor PVC insulated PVC sheathed / XLPE armoured cable ISI marked conforming to IE (Part I)1988 of National /Polycab/Havells or equivalent make as required with proper termination complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge. 1.5 sq. mm x 6 core
79Supply and fixing of 2 hour fire rated Steel Fire Door Frame 100x57mm single rebated as per site and location complete with directions of Engineer-in-charge/ Fire Officer.a) The door frame shall be 2 hours 3 criteria rating (Stability, Integrity and thermal Insulation) fire door- fabricated and complying with requirements of CBRI Roorkee/Government Department and conforming to relevant BS: 476 Part 20 & 22 & IS: 3614 Part II.b) The frame shall be fabricated from 1.6 mm thick galvanized steel sheet conforming to IS:277 with a factory pre-punhced groove so as to accomodate Fire & smoke seal size 10 x 4mm Frames should be butt jointed and field assembeled with bolting sytem for proper strength. Frames shall be provided with holdfasts, fasteners etc. complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.Note: The frame shoule be finished with Powder coating in desired shade.
80Providing and Fixing 46 mm thick Steel fire check door shutter of 120 minutes fire rating for stability & Integrity & 20 minutes of insulation confirming to BS:476 Part 22 and IS: 3614 Part II fabricated with 2 nos. 1.2 mm thick galvanized sheet with infill of fire rated Mineral Wool insulation filler of 64 Kg./M3 bonded to both faces of sheet with lock seam joints at stile edges and internal reinforcement at top, bottam and stile edges for fire rating. The door frames are manufactured from 1.6mm thick galvanized steel sheet pressed form to single Rebate profile of size 100mm 57mm. The door frames and door shutters are finished with \\"H\\" primer plus powder coating etc. complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.Note: The shutter shoule be finished with Powder coating in desired shade.
81Providing and fixing of 2 hour fire rated Door Closers UL tested for fire doors, fire tested in accordance of EN 1634-3 and for mechanical test to EN 1154 for 50000 cycles and shall be tested with fire door for 2 Hours fire rating door weight upto 36 kg, to 80 Kg and door width from 701mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc. complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.(Make - Assa Abloy / Dorma / Hafele / equvilent)
82Supply and fixing of 2hour fire rated 6mm thick, 2 Hrs. Fire Rated Glass clear glass which can also withstand thermal shock upto 800 degree centigrade shall be used as in vision panel and is to be fixed in between the glass beading by using ceramic fiber and fire rated acrylic sealant in accordance with BS : 476 Part 22, EN 1363/EN 1364 for stability and integrity etc complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.
83Supplying and Fixing of Stainless Steel Tower Bolt of 300 x 10 mm 2 hrs Fire rated on existing double leaf door shutters openable inside or outside etc. complete U.L. listed, CBRI tested complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.(Make - Assa Abloy / Dorma / Hafele / equvilent)
84Supplying and Fixing of Door Buffer 2 hrs Fire rated on existing single/ double leaf door shutters openable inside or outside etc. complete U.L. listed, CBRI tested complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.(Make - Assa Abloy / Dorma / Hafele / equvilent).
85Providing and fixing stainless steel 304 Grade D - Type pull handle 2 hrs fire rated of size 300 mm long and 22 mm Dia including stainless, Caps, nuts and bolts etc. of required size complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.(Make - Assa Abloy / Dorma / Hafele / equvilent)
86Providing and Fixing of 2hrs fire rated Mortice dead Lock of superior quality complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.(Make - Assa Abloy / Dorma / Hafele / equvilent)
87Supplying, installation, testing and commissioning of microprocessor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.Two Loop Panel
88Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required
89Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required
90Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required
91Supplying, installation, testing & commissioning of addressable manual call point complete as required
92Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required
93S/I/T/C of 4 x 1.5 sqmm Copper Conductor PVC Insulated and PVC sheathed / XLPE armoured cable ISI marked including saddles screw etc. as required for termination etc. complete in all respect to the entire satisfaction of Fire Officer.
94S/I/T/C of 6 x 2.5 sqmm Copper Conductor PVC Insulated and PVC sheathed / XLPE armoured cable ISI marked including saddles screw etc. as required for termination etc. complete in all respect to the entire satisfaction of Fire Officer.
95Supplying and Fixing of 80 Litres Capacity Seamless Cylinder CCOE Approved, complete with valve assembly and pressure gauge with a safety burst disc etc. complete as directed by the Engineer-In-Charge.
96Supplying and Fixing of 120 Litres Capacity Seamless Cylinder CCOE Approved, complete with valve assembly and pressure gauge with a safety burst disc etc. complete as directed by the Engineer-In-Charge.
97Supplying and Fixing of 140 Litres Capacity Seamless Cylinder CCOE Approved, complete with valve assembly and pressure gauge with a safety burst disc etc. complete as directed by the Engineer-In-Charge.
98Supplying and Fixing of FK-5-1-12 Fire Protection fluid compound of carbon, fluorine and oxygen (CF3CF2C(O)CF(CF3)2) etc. complete as directed by the Engineer-In-Charge.
99Supplying and Fixing of Electric Control Head operated electrically from the Detection & Control System or locally with a manual lever on the control head etc. complete as directed by the Engineer-In-Charge.
100Supplying and Fixing of Pressure Operated Control Head which allows for pressure actuation slave cylinders and is mounted directly on top of the slave cylinders valve etc. complete as directed by the Engineer-In-Charge.
101Supplying and Fixing of Discharge Nozzles are designed to provide the proper flow rate and distribution of FK-5-1-12 to total flood a hazard area : 180 deg. / 360 deg etc. complete as directed by the Engineer-In-Charge.
102Supplying and Fixing of Master Cylinder Adapter Kit used to actuate the Slave Cylinder etc. complete as directed by the Engineer-In-Charge.
103Supplying and Fixing of Discharge Hose, 2” (use with 80, 120 & 140 Ltr. Cylinders) etc. complete as directed by the Engineer-In-Charge.
104Supplying and Fixing of 2\\" Manifold Check Valve installed at the discharge manifold to allow removal of any FK-5-1-12 cylinder from the manifold while still retaining a closed system etc. complete as directed by the Engineer-In-Charge.
105Supplying and Fixing of Flexible Actuation Hose (Pilot pressure is directed to a pressure operated control head on each cylinder valve using 1/4 inch actuation hose) etc. complete as directed by the Engineer-In-Charge.
106Supplying and Fixing of Manifold Supervisory Switch for indication of discharge of system etc. complete as directed by the Engineer-In-Charge.
107Supplying and Fixing of Cylinder Protective Cap for 42 Bar System etc. complete as directed by the Engineer-In-Charge.
108Supplying and Fixing of Cylinder Strap for 80 Ltr. Cylinder etc. complete as directed by the Engineer-In-Charge.
109Supplying and Fixing of Cylinder Strap for 120 & 140 Ltr. Cylinder etc. complete as directed by the Engineer-In-Charge.
110Supplying and Fixing of Brass Male Tee etc. complete as directed by the Engineer-In-Charge.
111Supplying and Fixing of Brass Male Elbow etc. complete as directed by the Engineer-In-Charge.
112Suppying and Fixing of cylinder frame and support for one cylinder etc. complete as directed by the Engineer-In-Charge. For one cylinder
113Suppying and Fixing of cylinder frame and support for one cylinder etc. complete as directed by the Engineer-In-Charge. For two cylinder
114Suppying and Fixing of cylinder frame and support for one cylinder etc. complete as directed by the Engineer-In-Charge. For four cylinder
115Suppying and Fixing of cylinder frame and support for one cylinder etc. complete as directed by the Engineer-In-Charge. For one cylinder
116Suppying and Fixing of cylinder frame and support for one cylinder etc. complete as directed by the Engineer-In-Charge. For two cylinder
117Suppying and Fixing of cylinder frame and support for one cylinder etc. complete as directed by the Engineer-In-Charge. For four cylinder
118Supplying and Fixing of M.S. Sechule 40 seamless pipe including painting and pipe pressure testing job for following cylinder etc. complete as directed by the Engineer-In-Charge.For one cylinder
119Supplying and Fixing of M.S. Sechule 40 seamless pipe including painting and pipe pressure testing job for following cylinder etc. complete as directed by the Engineer-In-Charge.For two cylinder
120Supplying and Fixing of M.S. Sechule 40 seamless pipe including painting and pipe pressure testing job for following cylinder etc. complete as directed by the Engineer-In-Charge.For four cylinder
121Supplying and Fixing of Gas Release Panel etc. complete as directed by the Engineer-In-Charge.
122Supplying and Fixing of 7.2 AH X 12 V batteries with racks etc. complete as directed by the Engineer-In-Charge.
123Supplying and Fixing of smoke detector etc. complete as directed by the Engineer-In-Charge.
124Supplying and Fixing of 4*4 Junction box etc. complete as directed by the Engineer-In-Charge.
125Supplying and Fixing of Hooter with strobe etc. complete as directed by the Engineer-In-Charge.
126Supplying and Fixing of Cable gland, PG-19. PVC material etc. complete as directed by the Engineer-In-Charge.
127Supplying and Fixing of Manual release switch etc. complete as directed by the Engineer-In-Charge.
128Supplying and Fixing of Manual abort switch etc. complete as directed by the Engineer-In-Charge.
129Supplying and Laying of 2 Core, 1.5 Sq. mm FRLS armoured cable etc. complete as directed by the Engineer-In-Charge.
130Supplying and Fixing of other accessories like saddle, conduit, flexible conduit, cable tie, screw, screw sleeve, fastner, nut-bolt screw etc. complete as directed by the Engineer-In-Charge.
131Supplying, installation, testing & commissioning of Addressable smoke detectors bring the latest and most advanced detection technology to provide very early warning and the best nuisance alarm rejection to a wide range of applications. Built on the Flair detection technology and years of application experience, laser based ultra high sensitive aspiration smoke detector with sensitivity range of 0.005 % OBS / m TO 20 % OBS / M, having 1 pipe inlets, shall support minimum 130 meters pipe length per pipe, inlet Area Coverage 1,000 m2 (10,760 sq. ft) by one pipe single detector, 4 alarm levels, auto cleaning mechanism for detection chamber, on-board dual stage filter with memory, built-in event memory of 20000 events, pipe wise 4 stage flow monitoring, LED indications for alarm and fault conditions .Detector shall have an IP 66 rated enclosure and shall be suitable for Harsh environment applications, also detector shall support installation of additional displays & relay cards at remote location over 2 core wire for remote monitoring / alarmProposed aspiration detector shall be UL, FM, EN, LPCB & VDS approved.
132Supplying, installation, testing & commissioning of laser based ultra high sensitive aspiration smoke detector with sensitivity range of 0.005 % OBS / m TO 20 % OBS / M, having 1 pipe inlets, shall support minimum 130 meters pipe length per pipe, inlet Area Coverage 250 m2 (2690 sq. ft) by one pipe single detector, 4 alarm levels, auto cleaning mechanism for detection chamber, on-board dual stage filter with memory, built-in event memory of 18000 events, pipe wise 4 stage flow monitoring, LED indications for alarm and fault conditions . Detector shall have an IP 66 rated enclosure and shall be suitable for Harsh environment applications, also detector shall support installation of additional displays & relay cards at remote location over 2 core wire for remote monitoring / alarm. Proposed aspiration detector shall be UL, FM, EN, LPCB & VDS approved.
133Supplying, installation, testing & commissioning of Power Supply Unit for above Detector 220VAC to 24VDC 2 Amp Power Supply,FM approved with 24 hour battery back up
134Supplying, installation, testing & commissioning of End cap or Nozle Termination as per required.
135Supplying, installation, testing & commissioning of CPVC PIPE 22.5 mm internal Fittings dia complete in all respect as required.
136Supplying and Fixing of Water Tank made of Stainless Steel grade 304 of Capacity 5000 LTRS,Dia-1800mm, Height-2000mm,Shell Thk 5mm, Top/Bottom Flat Thk-6mm, Inlet/Outlet & Manhole As Per Requirement, Type-Vertical Cylindrical Tank, MOC-SS304 (Weight 800KGAppx.)etc.complete to the entire satisfaction and direction of Fire Officer/Engr-in-Charge.
137Providing and laying cement concrete in foundation for Polyethylene Water StorageTank at terrace level including thecost of centering, shuttering and finishing1:2:4 (1 Cement: 2 coarses and (zone-III) derived from natural sources : 4 graded stoneaggregate 20 mm nominal size derived from natural sources)
138Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)(a) Horizontal type,multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b) Suitable HPs quirell cage induction motor TEFC type suitable for operation on 415 volts,3 phase,50 Hz,AC supply with IP 55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325.(c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.(d) Suitable cement concrete foundation duly plastered and with anti vibration pads. 900 lpm at 35 m Head
139P/F/T/C of Motor Control panel of cubical construction floor mounted type, fabricatedout of 2mmthickCRCAsheet, compartmentalized with hinged lockable doors, dust & vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with solid aluminium strip/single core PVC insulated FRLScopper conducted cable, having suitable mounting for switch hear & accessories & internal control (relay,timer,sensor annunciation window for fault indicationON/OFF/TRIP indication alongwith suitable conductors, overload protection, current sensing type single phase preventer & colour coded powerwiring with suitable size fire retardant low smoke PVC insulated copper cable with conductor,earth terminals,numbering suitable for operation on 415 V,3 phase,50 HZ AC supply with enclosure protection class IP 42 complete as per satisfaction. Starter meter, selector switches, indicating LED with terminal facilities for repeat indicator of various audio & visual at terrace level & remote push button for ON/OFF operation in Fire Control Room etc. complete to the entire direction and satisfaction of Engineer in-Charge Suitable for Terrace pump - 02 Set
140Sub Part -C-3/1: (Minor Component: Supply, Installation, Testing & Commissioning of Civil Infrastructure )Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift up to 1.5 m, as directed by Engineer-in-Charge: All kinds of soil
141Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.
142Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 manufactured sand derived from Recycled Concrete Aggregate (RCA) : 10 graded stone aggregate 40 mm nominal size including Recycled Aggregate (RA))
143Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand(zone-III) including manufactured sand derived from Recycled concrete aggregate (RCA) up to 25% : 4 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 25% )
144Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
145Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : Red sand stone - exposed face fine dressed with rough backing. .30 mm thick
146Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood.
147Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
148Providing M.S. Piano hinges ISI marked IS : 3818 finished with nickel chromium plating grade 1 as per IS: 1068 and fixing with necessaryscrews etc., complete. Overall width 65 mm
149Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
150Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete. 50 mm
151Providing and fixing bright finished brass handles with screws etc. complete:125 mm
152Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 250x10 mm.
153Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 125 mm
154Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 1.0 mm thick
155Providing and fixing plain lining with necessary screws/nuts & bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-incharge (Frame work shall be paid for separately).12mm thick commercial ply conforming to IS : 1328 BWR type
156Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod pf approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS:16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for:(i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 (ii) Sites with structure height more than 20m for all wind speeds. Casement cum fixed panel window having single casement panel at both ends & middle fixed panel with S.S 304 friction hinges as per size and weight of sash, multi-point locking system, zinc alloy (zamak) powder coated handles. Using R3 series with frame (55mm & above) x (45mm & above) & sash (55mm & above) x (65mm & above) & mullion (55mm & above) x (65mm & above). (Height upto 1.8 meter; each openable shutter upto 0.8m width)
157Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes.
158Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
159Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
160Providing and fixing removable raised/false access flooring with system and its components of approved make for different plenum height with possible height adjustment upto 50 mm, comprising of modular load bearing floor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of:(a) Providing at required spacing to form modular framework, pedestals made out of Gl tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.l. pedestal head of size 75mmx75mmx3.5 mm welded with Gl fully threaded stud 16mm outer diameter with two Gl Check nuts screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate using epoxy based adhesive of approved make or the machine screw with rawl plug.(b) Stringers system in all steel construction hot dipped galvanized of rectangular size 570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-charge.(c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip noncombustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with High Pressure laminate with Non Warp technology upto 1mm thickness for superior adhesion and Surface flatness within 0.75mm. The panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved manufacturers specification and as per the direction of Engineer-in-charge. All specification must be printed on the side of the panel to ensure the quality of the product. 150mm Finished Floor Height(FFH)
161Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
162Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness60 microns (minimum), including factory painted after bending and perforation and backed with a black Glass fiber acoustical fleece.
16312 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand)
164Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
165Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
166Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
167Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.old work (one or more coats)
168Varnishing with flatting varnish of approved brand and manufacture one or more coats on old work.
169Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/rubbish to the nearest municipal dumping ground, all complete as per directions of Engineer-In-Charge. For door/ window/ clerestory window.
170Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
171Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.. In cement mortar
172Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below.
173Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
174Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge.
175Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
176Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shallbe measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
177Taking out existing kerb stones of all types from footpath/ central verge, including removal of mortar etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
178Laying at or near ground level old kerb stones of all types in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints, except at sharp curve, shall not be more than 5 mm), including making drainage opening wherever required etc. complete as per direction of Engineer-in-charge. (Length of finished kerb edging shall be measured for payment). (Old kerb stones shall be supplied by the department free of cost)
179Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
180Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10 kg/sqm)
181Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600mm center to center in a floor and ceiling channel section of size 50 x 32m fixed to the floor and soffit at 600mm centers using 12mm dia, 50mm long wedge type expanded zinc alloy dash fastner with 10mm bolt. This same channel is then to be fixed in horiziontal direction at 600mm center to center so as to form a grid of 600mm x 600mm. Glasswool of 50mm thickness is then to be inserted in the slots and finally calcium silicate non combustible panels/ tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished using recommended jointing calcium silicate based compound and fiber joint tape roll 50mm wide (90 metre) roll and two coats of primer suitable for panelling as per manufacturer’s specification as per direction of Engineer-in-Charge all complete. With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles
182Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge 15 mm thick false ceiling tiles at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistance of 100%, thermal conductivity < 0.043 W/m K as per ASTM 518:1991,in true horizontal level and as directed by Engineer-in-charge
183Providing and laying DN 160 mm dia HDPE Pipe of Pressure Cuts PN-3.2 of PE63 & SDR 33 as per IS 4984-2016 approved make and quality including jointing with both fusion both weld appropriate meterial including accessories etc. complete as per instrcution and direction of Engineer-in-charge
184Providing and fixing Roller Blind of reputeted make of approved fabric having facility of folding locking complete arrangement i/c cutting fixing as per site requirement and approved by engineer-in-charge(only area of window to be measured for payment purpose).
185Providing and fixing glazing in aluminium/uPVC door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . With toughnened glass panes of 6 mm thickness.
186Providing and fixing Stainless steel grade 304 brush finished plate of required size and 0.9mm to 1.0mm with side bending made in deep photo etching. The required informatory matter wages picture etc filled with colour in PU combination, polished border and fixing arragement at the back using studs etc complete (surface area with bend shall be measured for payment pupose)
187Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical means, including loading ,transporting and unloading the same at any C&D waste management site within 25 kms lead i.e. Shastri park/ Burari/ Mundka including weighing at plant etc complete as per direction of Engineer in charge. Weighing and unloading at plant shall be as per procedures/rules of the plant management. The rates are inclusive of all operations, labours, lead and lifts from site of work to the C&D waste plant. The processing fee of C&D management at prescribed rates will be deposited by the agency and the same shall be reimbursed by department on production of only original cash receipts.
188Sub Part -C-3/2: (Minor Component: Buy Back items of Civil Infrastructure )Purchase and taking away dismantled material which is to be received from the work on as is where is basis. Cartage of dismantled material shall be bron by the contractor himself and the cost of dismantled material shall be received from the contractor. Aluminium scrap Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57328168
AUTHORITY Local Bodies
TENDER VALUE 2.64 Crore
LAST DATE 13-10-2026
Authority
Authority Name New Delhi Municipal Council
Work Description Tender for Composite Work For Establishment Of Electrical, Civil, Fire And It Infrastructure For Scada Disaster Recovery Centre At 66/11 Kv Ess B.D Marg.
Basic Detail
Tender No O1/EE(E) SCADA and AMISP/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 24 Sep 2026
Submission Date 13 Oct 2026
Open Date 13 Oct 2026
Finance
Tender Value 2.64 Crore
Tender Fee Ref. Documents
EMD 5.29 Lakhs
Exemption Not Available
Document List
7c948938-f842-4e70-beeb-21733980a938.html
BOQ_397117.xls
Tendernotice_1 (14).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 24, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 13, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 14 days
Oct 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 14 days
Oct 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

7c948938-f842-4e70-beeb-21733980a938.html

xls

BOQ_397117.xls

pdf

Tendernotice_1 (14).pdf

Disclaimer