Defence Statutory Bodies & Commissions/Committees Closing in 9 days TDR #57326905

Tender For Special Repairs To Bldg Nos. Np-69/2, P-95/1, T-96/2 And T-97/1 At Mil Stn Dhrangadhra

Issued by Statutory Bodies & Commissions/Committees · Surendranagar, Gujarat
Tender Value
Ref. Documents
Estimated cost
Bid Submission
22 Sep 2026
9 days left
EMD
76400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Surendranagar → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repairs To Bldg Nos. Np-69/2, P-95/1, T-96/2 And T-97/1 At Mil Stn Dhrangadhra

BOQ

Name of Work:- SPECIAL REPAIRS TO BLDG NOS. NP-69/2, P-95/1, T-96/2 AND T-97/1 AT MIL STN DHRANGADHRA
Sl. No. Item Description
1Taking down old cement plaster any description on brick or stone wall/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc complete as specified and directed.
2Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
3Demolition of reinforced cement concrete in any position not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
4M&L for PCC 1:3:6 type C-1 using 20mm graded stone for embedding of hold fast etc complete all as specified and directed.
5M&L, providing cement concrete 1:2:4 type B1 as in, coping, benching, bressumers, steps, incl necessary form work complete all as specified and as directed.
6M&L for RCC (Nominal mix) type B-1 (1:2:4) (20mm graded aggregate) as in Slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including demolition of existing RCC work in any position complete all as specified and directed.
7M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.
8Supply & Fix 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
9Taking down chowkhat or frames with shutters (without taking off shutters from the frame) exc 1.5 Sqm but n.exc 4 Sqm each complete all as specified and directed.
10Taking down chowkats or frames but with shutters (without taking off shutters from the frame) n.exc 1.50 sqm each complete as specified and directed.
11Taking down old shutters of any description exc. 1 sqm but not exc. 2 sqm each complete all as specified and directed.
12S&F in repair Stainless steel Door hinges medium weight, cold rolled 100 mm size all as specified and directed.
13S&F, in repair stainless steel tubular towel rail 20mm dia, D type, 600mm long complete all as specified and directed.
14Demolition of Brickwork or stone/ boulder masonry, built in CM including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
15M & L for walling of random rubble, uncoursed well bounded, bedded and solidly hearted, built in Cement Mortar 1:6 complete all as specified and directed.
16M & L for walling (Except stone) of random rubble, uncoursed well bonded, bedded and solidly hearted, built in Cement Mortar 1:6 complete all as specified and directed
17Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface n exc 20mm for sand stone and dressing to face stones and dressing of face beds and joints as specified ,of random rubble walling ,uncoursed or brought upto courses completed as specified and directed .
18S&F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws in single length complete all as specified and directed.
19S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
20M&L for false ceiling, consisting of wall angles, main T, cross T all of zise 25mm x 25mm x 1.4mm thick powder coated GI grid frame work jointed angle as directed and mild steel hooks not less than 4mm dia with arrangement for adjesting heights of ceiling with and incl provision of 4mm thick E boards sheet in panels of size 600mm x 600mm with necessary off cuts and fixing arrnagement for ceilling, tube light fitting incl dismantling of existing false ceiling complete all as specified and directed.
21M&L for 18-19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work in cupboard, rebated or flat edged complete all as specified and directed.
22Dismantling floor ,hearth or wall tiling incl cement mortar bedding (but not backing) complete all as specified and as directed.
23Dismantling wrought iron or mild steel work of any description not otherwise proviceded for complete as specified and directed.
24M&L for Non-skid white ceramic tiles 7 to 8 mm thick (square/ rectangular), area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm, as in floors etc. set & jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in CM 1:6 complete as specified and directed.
25M & L, non skid joint free coloured ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 Sqm, in floors over and including 15 mm thick screed bed in CM 1:6 as in floor etc set & jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
26M & L, non skid joint free coloured ceramic tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 Sqm, over and including 15 mm thick screed bed in CM 1:6 as in floor etc set & jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed.
27M & L, glazed joint free coloured ceramic tiles in vertical surface as in skirting & dado, 7 to 8 mm thick area exc 0.06 Sqm but n.exc 0.18 Sqm over and including 10 mm thick rendering in CM1:4 set & jointed in neat cement slurry & pointed in coloured cement to match complete all as specified and directed.
28M&L for rendering cement plaster 10 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface on walls complete all as specified and directed.
29M&L for 15 mm thick cement plaster on fair faces of brick work or concrete surfaces on wall in CM 1:6 finished the plaster surfaces fair and even complete all as specified and directed.
30M&L for 10 mm thick rendering in CM 1:4 on ceiling, soffits, chajja projection etc complete all as specified and directed.
31M&L for 10 mm thick rendering in CM 1:4 on ceiling, soffits, chajja projection (external surfaces) etc complete all as specified and directed.
32M&L for 10 mm thick cement plaster on fair faces of brick work or concrete surfaces on wall in CM 1:6 and finishing even and smooth without using extra cement complete all as specified and directed.
33M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
34M&L for preparation of old plastered surface of wall and applying one coat of cement base paint complet all as specified and directed .
35Preparing of plastered or unplastered old decorated surfaces of walls by complete removal of existing treatment, moulds, moss and efflorescent salt and treating oil and greasy spots and applying three coat of white wash on walls including cornices etc complete all as specified and directed
36Preparation of New plastered surfaces of ceiling and applying Three coat of white wash on ceiling including cornices etc complete all as specified and directed.
37Preparation of plastered or unplastered old decorated surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soots, treating oily/greasy spots, moss and efflorescence and applying two coat of white wash on ceiling including cornices etc complete all as specified and directed.
38Preparation of new plastered surfaces and applying two coat of oil bound distemper over and including a layer of wall care putty to achive a smooth finish surface (average thickness 1 mm) complete all as specified and directed.
39Preparation of old plastered surfaces by complete removal of existing treatment and applying two coat of oil bound distemper over and including a layer of wall care putty (average thickness 1 mm) complete all as specified and directed.
40S&F 4mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq.m in each pane complete all as specified and directed.
41M&L for preparation of new wooden surface of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
42M&L, preparing old previously treated surface of wood and wood based surfaces exceeding 10 cm in width or girth and applying one coat of synthetic enamel paint on old decorated wooden surfaces, complete all as specified and directed.
43M&L, preparing of new steel surface exceeding 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
44M&L, preparation old previously treated steel Surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint on the steel surfaces, complete all as specified and directed.
45S&F standard aluminium section powder coated any colour as approved for window/ventilator frames/shutters sliding/ partitions etc including jointing cleat and rubber eading/linning, Pivot ,locking aragement and all hardware etc and fixed in position with stainless steel screws all as specified and as directed.
46S&F in repair sheet glass 4.8 mm thick ordinary quality and glazing with oil putty in square n.exc 0.8 sqm in each pane complete all as specified complete as specified and directed.
47S&F M.S Framed work such as grills gratings etc with ends of bars sholdered and/or riveted into spikes, framed guard bars / railings all as directed.
48S&F galvanised mild steel wire cloth 0.56 mm nomonal dia of bar and 1.18 mm avrage width of aperture ,fixed with tined tacks or galvanised wire staples complete all as specified and as directed.
49S&F, factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fit-ted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete all as specified and directed.
50S&F, solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube and fixing in opening as per specification complete all as specified and directed
51S&F, aluminium, anodised barrel tower bolts 200mm long of extruded section and fixed complete all as specified and directed.
52S&F, aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy with length of bolt 300 mm and fixed complete all as specified and directed.
53S&F , butt hinges 100mm long, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, complete all as specified and directed.
54S&F, aluminium handles 150mm size, cast type, anodised complete all as specified and directed.
55S&F, 150mm long floor door stopper of aluminium alloy body and tongue with hard drawn steel springcomplete all as specified and directed.
56S&F Harrison rails, mild steel chromium plated with fixing brackets ,stops ,rolleres etc complete all as specified and as directed.
57M&L for RCC 1:1.5:3 type A-1 as in Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified and as directed.
58Use and waste of form work to soffit of suspanded slab such as roof slab ,floor slab landing and similar work n exc 200mm thick (horizontally or sloping complete all as specified and as directed.
59Taking down of roof trusses, above 4 mtr & up to 8 mtr coupled rafters or trussed beams complete all as specified and as directed.
60M&L for MS TMT bars10mm dia and over cut to Length bent to shape required including cranking, bending, spirally for hooping for columns with an incl MS wire(Annealed not less than .90 mm Dia) or securing with clips complete all as specified and directed.
61M&L for TMT 6 to 8 mm dia bar, cut to length, bent to shape required, including cranking, bending, hooking ends, binding with and inlcuding mild steel wire (annealed) not less than steel wire 0.9mm dia or securing with clips and confirming to FE-410-S and 310-0) complete all as specified and directed.
62S&F, rolled mild steel section as in main and cross beams hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding door fixed with angle cleats or other connecting plates conforming to Fe-290, Gde E-165 all as specified and directed.
63Fixing only rolled mild steel section as in main and cross beams hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding door fixed with angle cleats or other connecting plates conforming to Fe-290, Gde E-165 all as specified and directed.
64Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-290 Gde E-165 complete all as specified and directed.
65M&L for rolled mild steel angle iron work as in door frames complete, drilled for fixing of hinges etc. also fastening and fixing conforming to Fe-290 (Gde-E-165) complete all as specified and directed.
66Granite (of any type/ colour) work (table rubbed and polished) 18 to 20mm thick in steps jambs,pillars, window cills, cooking plateform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bed in CM 1:6 incl moulding, chamfering of edges complete as specified and directed.
67M&L for 25mm thick cement concrete type B-0,1:2:4 (12.5 mm graded aggregate) for roof padding finishing cement concrete surface even and smooth with out using extra cement complete as specified and directed.
68M&L for 15 mm thick rendering on fair faces of concrete surfaces of roof as water proofing treatment in CM 1:4, including finishing the surfaces even and smooth, complete all as specified and directed.
69M & L in repair for water proofing treatment to roofs surfaces including a coat of applied bituminous shalitex primer @ 0.30 lit per sqm evenly on roof surface and a coat of hot bitumen 85/25 @ 1.2 kg/sqm shall be applied on primed surface and laying of 3mm thick APP modified polymeric membrane (weight not less than 3 kg/sqm) unrolled and bonded completly to the substrate with side overlap of 75 mm and end overlap of 100 mm and then sealed/fused by flame or bitumen and a coat of hot blown bitumen grade 85/25 @ 1.2 kg/sqm shall be applied on top of APP modified polymeric membrane as per manufacturer instruction and finally it will be finished with a coat of aluminium paint @ 0.20 kg/sqm ,complete all as specified and as directed .
70Demolition of plain cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
71S&F in repairs bib taps cast copper alloy chromium plated fancy type with crutch or butterfly handle screw down ,screwed for iron pipe or or brass ferrule for 15 mm bore of pipe complete as specified and directed.
72S&F in repairs Stop valves/ Angle valves cast copper alloy chromium plated fancy type with crutch or butterfly handle screw down ,screwed for iron pipe or or brass ferrule for 15 mm bore of pipe complete as specified and directed.
73Supply & Fix in repair vitreous china hand wash basin basin white exclusive quality flat back size 550 x 400 mm including brackets, PVC waste pipe and waste coupling fixed complete all as specified and directed.
74S&F, in repairs, 15mm stop valves, fancy type brass chromium plated for iron pipe or for unions and fixed to 15mm bore pipe, complete all as specified and directed.
75S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
76Supply & Fix in repair 600 mm long PVC Connection 15mm size with PTMT nuts complete all as specified and directed.
77Supply & Fix in repair 15 mm dia pillar tap (long nose)cast copper alloy with capstan head chromium plated fancy type, screwed down high pressure, with or without lettered \\"Hot or Cold\\" with long swan neck swivel type screwed for iron pipe and fixed complete all as specified and directed.
78Supply & Fix in repair 15 mm bore Stop valves cast copper alloy chromim plated fancy type with long shank and cup (concealed type) screwed down , high pressure , screwed both ends for iron pipe or for unions complete all as specified and directed.
79S&F in repair vitreous china squatting pan, orrisa pattern, size 580mm x 440mm white, with integral foot rests (excluding flushing cistern & flush pipe) including making good to disturbed floor with PCC complete all as specified and directed.
80Supply & Fix in repair Vitreous China wash down water closet pan (pedestal pattern), white (excluding flushing cistern ) including connection to drain (or outgoing pipe) and to flushing pipe , antisyphonage pipe ,with PVC cover sheet in same colour etc complete all as specified and directed.
81S&F C P Hand shower (health faucet) 1 mtr PVC tube with wall hook complete for EWC, all as specified and directed.
82S & F Brass chromium plated shower rose 125mm size incl shower arm complete all as specified and directed.
83S & F in repair Toilet paper holder with flat recessed type stainless steel complete all as specified and directed.
84S & F Soap dish chromium plated approximate size 160x 160x90mm complete all as specified and directed.
85S&F 20mm bore dia of pipe Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (minimum weight 20mm -210 gms ) complete all as specified and directed.
86S&F, in repair, 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -210 Gms) complete, all as specified and directed.
87S&F in repairs PVC low level 10 lit capacity valveless syphonic action type flushing cistern including 32mm dia PVC flush pipe fixed in repairs complete all as specified and directed
88Supply & Fix in repair vitreous china urinal, Half stall type, white (excluding flushing cistern) incl providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and incl 60mm long brass screws, pointing around urinal back in cement, fixing flush pipe, grating and union for discharge pipe incl supply and fixing of 32mm bore 60mm long discharge pipe complete all as specified and as directed.
89S&F towel rail 600mm long of chromium plated with and incl chromium plated brass screw and wooden /plastic cleats complete as specified and directed.
90S&F chromium plated brass Peg set of Six fixed with brass screw and wooden /plastic cleats complete as specified and directed.
91M&L for 25mm Thick Cement Concrete Type B-1, 1:2:4 (20mm Graded Aggregate) complete all as specified and directed.
92S&F 600x450 mm bevelled edge of slected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screws and cup washers complete all as specified and directed.
93Dismantling water tanks of capacity exc 250ltr but not exc 500ltr and removing from site complete all as specified & directed by Engr-in-Charge.
94S&F Rotational moulded polyethylene water storage tanks of 500 Ltrs capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified & directed by Engr-in-Charge.
95S&F 1000 litres capacity rotational moulded polyethylene water storage tanks double layer (cylindrical vertical with closed top) hoisted and fixed in position including dismantling complete all as specified and directed
96Taking up or down steel tubing 15 mm bore and connection including cleaning for refixing complete all as specified and directed.
97Refixing old serviceable 15 mm GI tubing and connection in new or old position (concealed in Wall, ceiling & floor etc.) including necessary fittings & fixtures etc. complete all as specified and directed.
98S&F, 15 mm bore tubes medium grade galvanised with all fittings and fixed to walls, ceilings or laid concealed in floors incl cutting chases where required incl taking down 15 mm bore steel tubing and connections complete complete all as specified and directed.
99S&F in repair 15 mm bore tubes medium grade galvanised with all fittings and fixed to walls, ceilings or laid concealed in floors incl cutting chases where required incl taking down 15 mm bore steel tubing and connections complete complete all as specified and directed.
100Taking up or down steel tubing 20 mm bore and connection including cleaning for refixing complete all as specified and directed.
101Refixing old serviceable 20 mm GI tubing and connection in new or old position (concealed in Wall, ceiling floor etc.) including necessary fittings & fixtures etc. complete all as specified and directed.
102S&F, 20 mm bore tubes medium grade galvanised with all fittings and fixed to walls, ceilings or laid concealed in floors incl cutting chases where required incl taking down 20 mm bore steel tubing and connections complete complete all as specified and directed.
103S&F in repair 20 mm bore tubes medium grade galvanised with all fittings and fixed to walls, ceilings or laid concealed in floors incl cutting chases where required incl taking down 20 mm bore steel tubing and connections complete complete all as specified and directed
104S&F 20mm Gate valves with iron wheel head screwed both ends for iron pipe and fixed complete as specified and directed.
105S&F, in repair, 20mm Gate valves with iron wheel head screwed both ends for iron pipe and fixed complete as specified and directed.
106Supply & Fix in repairs, 75mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors and fixed to wall with PVC holding clamps complete all as specified and directed.
107S&F in repairs, 110mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors and vertical surfaces complete all as specified and directed.
108Supply & Fix in repairs, 75mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors and fixed to wall with PVC holding clamps complete all as specified and directed.
109S&F in repairs, 110mm bore PVC(SWR) pipes single socketed , in any length with rubber ring joints, laid in trenches or in floors and vertical surfaces complete all as specified and directed.
110S&F in repairs, 125/110mm bore PVC (SWR) 'P’ trap complete all as specified and directed.
111S&F in repairs, 75mm bore dia PVC floor trap (SWR) plain with grating including jointing with solvent cement to waste pipe complete all as specified and directed.
112S &F PVC (SWR) 75 mm dia vent cowl complete as specified and directed.
113S&F in repairs, 110mm bore PVC(SWR) bends any radius, complete all as specified and directed.
114S & F in repairs white glazed earthen ware vitreous china wash hand basin of size 550x400mm with and including CI brackets, 32mm bore brass CP waste coupling Inlet/ outlet, PVC flexible pipe, 600mm size for 15 mm bore pipe with brass nut and washers etc complete as specified and directed.
115M&L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm graded Stone aggregate) as in plinth protection finisheed even and smooth without using extra cement complete all as specified and as directed.
116M&L for 75 mm thick cement concrete 1:3:6 type C2 (using 40 mm graded Stone aggregate in plinth protection finisheed even and smooth without using extra cement including forming necessary joints 12 mm wide to the full depth of PCC at every 3 metre and at change in direction complete as specified and directed.
117M&L for cement concrete 75mm thick type C-2 (1:3:6) using 40 mm graded agg as in sub base to flooring and including demolition of existing concrete work complete as specified and directed.
118Demolition of precast concrete articles and pre-cast cement concrete block walling, ashlar fencings, dressed stone work including all quoins, arches, pillars etc. built in cement mortar complete all as specified and directed.
119Dismantling timber scantling 40 sqcm and over in section ,an any position (framed) complete as specified and directed.
120Dismantling fillet rails, post rafter purlin etc. under 40 sqcm and over in section ,an any position (unframed) complete as specified and directed.
121Dismantling of Asbestos cement (corrugated, semi corrugated, etc) sheet in roof covering complete all as specified and directed.
122M&L, precast cement concrete Block Masonary with solid blocks type C1, 1:3:6 (20mm graded stone aggregate) exc 10 cm in width and setting in mortar 1:6 complete all as specified and directed .
123M&L, precast cement concrete Block Masonary with solid blocks type C1, 1:3:6 (20mm graded stone aggregate) (except blocks) exc 10 cm in width and setting in mortar 1:6 complete all as specified and directed .
124Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete along with fittings such as switches, ceiling roses, bell, regulators sockets etc, and removing from site and making good distribut surfaces of walls, floors etc all as directed.
125Taking down existing unserviceable MCB DB/TPN/SPN/SP along with MCBs complete by disconnecting all as directed.
126Taking down existing unserviceable T/light fitting & box type fitting complete as specified and directed.
127Taking down existing unserviceable sub main wiring 2.56 Sqmm aluminium/copper cable all as directed.
128M&L for point wiring for one light/fan/bell point controlled by one switch one way in & including PVC conduit concealed in brick or stone wall using FRLS PVC unsheathed multistrand copper conductor wire 1.5 sqmm single core for one light/fan point controlled by one switch including modular white cover plate with frame of suitable modules over modular metal flush box concealed type for earth continuity insulated PVC unsheathed (green colour) 1.5 sqmm copper earth wire connected to common earth dolly using complete all as specified and directed by Engr-in-charge. NOTE :- (i) wiring shall be done by using proper colour coding.
129(a) One light point controlled by one way 5 Amps switch
130(b) One ceiling fan/exhaust fan point controlled by one, one way 5 Amps switch
131(c) One 3 pin socket outlet 5 Amps on independent board
132(d) One 3 pin socket outlet 5 Amps on same board
133M&L for Point wiring complete with 2.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 2.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc., all as specified and as directed for one switch socket outlet 16 Amps on independent board.
134M&L for Point wiring complete with 4 Sqmm single core, PVC insulated unsheathed, FRLSH cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on brick/stone wall concealed etc, including provision of PVC insulated (green colour) 4 Sqmm FRLSH cable with copper conductor for earth continuity and connected to common earth dolly and metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc. all as specified and as directed for one switch socket outlet 16 Amps on independent board. Make : Polycab / Havells/Palaza/KEI . NOTE :- (i) wiring shall be done by using proper colour coding. (ii) making necessary plaster and painting as per the exisnting colour complete all as specified and as directed.
135M&L for sub main wiring complete with FRLS PVC insulated unsheathed stranded copper conductor wire 2.5 Sq mm 03 single core runs (for Phase & Neutal) along with earth wire FRLS PVC insulated unsheathed stranded copper conductor wire of size 2.5 sq mm wire drawn through in & including PVC casing caping or conduit as per site requirement complete all as directed by Engr-In-charge.
136M&L for Sub main wiring/power wiring complete with two runs of 6 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories concealed etc. with one run of PVC insulated, 6 Sqmm FRLS copper conductor for earth continuity all as specified and as directed. Note :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
137Supply & Fixing 5/6 Amps 1 way one modular switch complete as specified and directed.
138Supply and Fixing 5/6 Amps three pin socket modular complete as specified and directed.
139Supply and Fixing 15/16 Amps one way one modular switch complete as specified and directed.
140Supply and Fixing 15/16 Amps three pin socket modular complete as specified and directed.
141Supply and Fixing step type electronic fan regulator of capacity 100 watts 230 volts for ceiling fan flush type.
142Supply and Fixing Ceiling rose 3 terminal 5 Amps 230 volts PVC/ Polycarbonate, insulated body complete as specified and directed.
143Disconnection and removing the u/s MCB plug and socket unit and S&F moduler PVC box, 20A Socket and 20Amp moduler MCB SP, 10KA, 240 volt including 20Amp top complete all as specified.
144Disconnection and removing the u/s LED lamp and S&F LED lamp 9/15 watts complete all as spfd and directed.
145S&F VTPN 4 way double door with neutral and earth link, fixed on wall mounted, MCCB,s as incomer is 03 pole V-Tec of 100Amp rating 25KA breaking capacity for incoming supply of MCB is pre-fitted at factory & including price of MCB and provision of MCBs SP/TP as outgoing complete all as directed by Engineer in charge.
146Disconnection and removing carefully and taking down the existing ceiling fan of any size, and depositing to MES E/M store and S&F Ceiling fans 1200 mm sweep energy efficient five star rated 230volt with brushless directcurrent motor (BLDC) with blades, dowen rods, electronic regulators control type including down rods and connecting up with 3 runs of suitable size single core PVC insulated but unsheathed, FRLS cabe with multistanded copper conductors from ceiling rose to fan complete all as specified and as directed.
147S&F batten holder bakelite complete all as specified (ISI Marked) complete as specified and directed.
148S&F MCB DB, SPN, 8 way with 200 Amps rated copper bus bar with mild steel sheet enclosure, vertical, double door type suitable for fixing MCBs including connecting etc. complete all as specified and as directed. NOTE :- All as per specified sr no 09 to 16 make as per
149S & F in repairs MCB, SP, 240Volt, 5 to 32 Amps, breaking capacity 10 KA, complete as specified and directed.
150S & F in repairs MCB, SPN, 240Volt, 40 Amps, breaking capacity 10 KA, complete as specified and directed.
151S & F in repars MCB SPN, 240Volt, 32 Amps, breaking capacity 10 KA, complete as specified and directed.
152Supply and laying GI tubing light grade in tranches for protection of cable for 40 mm dia in cluding taking out. old pipe complete all as diercted by Engr -in-charge.
153Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 4 core complete as specified and directed.
154Excavation in treches not exc 1.5m in width and 1.5 M in depth for foundation of pole, laying of cables etc in Hard and dense soil and getting out complete as specified and directed.
155Returning, filling in including spreading levelling, watering, and well ramming in layers not exc. 25 cm in soft/loose soil complete as specified and directed.
156Removing excavated materials not exc 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete as specified and directed.
157M & L for sand filling using approved clean dry sand for cushioning of UG cables incl spreading levelling and well ramming in layers not exc 25 cm.
158M/L for sub class 'B'old size burnt bricks of class designation 100, for cable protection laid length wise perpendiculer to the axis of the cable complete as specified and directed.
159Disconnection and removing the u/s light fitting and S&F LED Batten box type made of CRCA sheet including 1X20 watt retro LED tube rods and pre-wired with high efficiency electronic driver and connecting with three core PVC copper flexible cable of size 23/.0076 from ceiling rose to connector block complete as specified and directed.
160S&F in repir LED Mirror light fitting complete made out of CRCA Sheet including 1x10 watt LED rod complete connecting up with three core pvc copper flexible cable of size 23/.0076 from ceiling rose to connector comlete all as specifid and as directed by Engr in charge.
161S&F LED flat panel of size 2'X2', 36 Watts, environmental friendly, new generation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling complete all as specified and directed by Engr-in-charge.
162Labour only for Cutting openings, through brick walls for fixing of exhaust fan, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core etc. and rubbish not exc. 50m. Forming jambs, etc. to openings for 300mm to 450mm exhaust fan including cutting in wall fo cement mortar 1:6, toothing, and properly bonding into old work, also facing, jointing and pointing to match existing work, complete
163Supply and fix of Exhaust fan, 300 mm sweep, MS body heavy duty, AC single phase, 230 volts with, blades, and frame and louvers including connection with 0.5 sqmm multistranded copper conductor flexible wire from ceiling rose, necessary fixing arrangement i.e anchor nut, bolt, washer, grouting and making good to disturbed surface complete all as specified and as directed.
164Supply and fix of Exhaust fan, 380 mm sweep, 1400 rpm, MS body heavy duty, AC single phase, 230 volts with, blades, and frame and louvers including connection with 0.5 sqmm multistranded copper conductor flexible wire from ceiling rose, necessary fixing arrangement i.e anchor nut, bolt, washer, grouting and making good to disturbed surface complete all as specified and as directed.
165Supply and fix electric water heater, storage type steel body with stainless steel inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated, 230Volts, single phase, 50 Hz AC, energy saving high density PUF insulation complete with all accessories such as safety valve, thermostate, NRV, inlet and outlet (cold & hot) PVC pipes upto 450mm long, with 15A plug top etc. complete all as specified and directed.
166Disconnection & taking down the unserviceable building light high wattage 30 Watts street light fittings and Supply & fixing energy efficient Intergral type LED 30W Street light luminaire comprising of epoxy powder coated hsg, enclosed with glass cover in frame mounted testing compelte with GI pipe bracket or clamp with nut bolt of suitable size for fitting complete all as specified and directed by Engineer-in-charge.
167M&L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth Lead 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth strip of 25x4mm as earth lead all as specified and testing on completion including provision of earth lead protected by 20 mm dia light grade GI pipe & watering pipe shall be 15 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions:-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 15 mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 20 mm bore light grade 7.5m. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57326905
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 22-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repairs To Bldg Nos. Np-69/2, P-95/1, T-96/2 And T-97/1 At Mil Stn Dhrangadhra
Basic Detail
Tender No GE(A)/GNR/TOKEN/84 of 2026-27
Bidding Type Tender
Location
City Surendranagar
State Gujarat
Key Dates
Publish Date 02 Sep 2026
Submission Date 22 Sep 2026
Open Date 24 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 76400
Exemption Available
Document List
BOQ_882626.xls
c81728e7-b14b-4c0d-8bd1-38745e4f083c.html
TenderDocuments.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Sep 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_882626.xls

html

c81728e7-b14b-4c0d-8bd1-38745e4f083c.html

pdf

TenderDocuments.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders