Housing Urban and Rular Development Government Departments Closing in 5 days TDR #57325062

Tender For Supply Installation Testing and Commissioning of Arena Light Fitting, Outdoor Hanging Light, 60Kva Servo Stabilizer And Ups, Repair Of Wooden Block Flooring In Badminton Arena And Repair Of Paver Block Of Approach Road In Mpis, Kesinga Of

Issued by Government Departments · Kalahandi, Odisha
Tender Value
25.38 Lakhs
Estimated cost
Bid Submission
10 Sep 2026
5 days left
EMD
25381
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kalahandi → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Supply Installation Testing and Commissioning of Arena Light Fitting, Outdoor Hanging Light, 60Kva Servo Stabilizer And Ups, Repair Of Wooden Block Flooring In Badminton Arena And Repair Of Paver Block Of Approach Road In Mpis, Kesinga Of Kalahandi District Buildings.

BOQ

Name of Work:- SITC of Arena Light fitting, Outdoor hanging light, 60KVA Servo Stabilizer and UPS, repair of wooden block flooring in Badminton Arena and repair of paver block of approach road in MPIS, Kesinga of Kalahandi District Buildings.
Sl. No. Item Description
1350W LED Sports Light fitting 44000 Lumen) with 80CRI (4KV inbuild and 10KV external surge protection, IP66, Aluminium die cast body,cool white (5700K),Impact resistance of IK08, Over current, short circuit, over voltage , dust and water protection, entire luminarie should act as Heat shrink(LED life 50000 burning hour),The fixture must have 3-4mm thick safety glass cover with BIS Certified driver of IP67 protection and fixture must have Two nos LED Driver as required of make Moso/Inventronics/Sosen. Light Fixture of make Bajaj CAT No GLEAM GF 420L ) or Equivalent of Philips/ DISANO/Abacus.
2S/F of 120 W 5700 K Cool White , IP Rating IP66,, Lumen 12000 lm Flood hanging Light ,make - Bajaj , Philips , Havells
3Supply of of 120 sq mm AB Cable to replace damaged incoming cable
4Supply and Making end Termination with brass compression gland and aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable) 3.5C X 120 sqmm
5SITC of 60 KVA servo Volatge stabalizer with following specification: Ol colled , unbalanced type , Input - 330 - 470 V AC , Output - 400 V 1 , . Connection - Star / Star (3 P N) ,Type - Unbalanced Type, Independent Phase Regulations ,Metering - Voltmeter to Read Input / Output Voltages using Toggle Switch. Construction - Variable Auto Transformer Buck Boost Transformer Servo Motor ,Auto Transformer : Copper Wound ,IS Standard : As per IS: 9815 Standards.Frequency : 47 - 53 Hz. ,Response Time : 10 Milli Seconds ,Rate of Correction : As per IS: 9815 Wave Form Distortion : Nil ,Efficiency : As per IS: 9815, Ambient Temperature : 0 - 50 C. ,Insulation : Class B as per IS 9815 ,Duty Cycle : Continuous. Voltage Adjustment : Provided. ,Enclosure : MS TANK Enclosure on Wheels with suitable Input /Output , Terminations, Cable Box, Oil Filling Hole, Oil Level Indicator.make-
6Supply of cable 35sq mm x 3.5 core for panel to stabalizer connection , make - Havells , Polycab , RR Kabel
7Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
8Supplying and making end termination with aluminium lugs for above mentioned size cable.as per direction of Engg.-in-Charge.
9Supplying,installation,testing andcommissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts and washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil and rock as required and as per direction of Engineer-in-charge.
10Supply and fixing of SPD type II in existing TPN DB/ Panel with 32amp 4P MCB in series including all accessories
11Supply ,installation ,testing and commissioning of 20KVA Parallel UPS SYSTEM WITH IGBT based inverter system, true online double conversion system, inbuilt isolation transformer & automatic phase sicuency corrector of 3ph in put to 3 ph output,415V, with built in BMS with battery back up up to 30 minutes with MS Rack for battery Housing, DC cable 7 Mtr with SFU and links for installation (Battery required: 12V, 65AH, 32 No.s) protection for fault by OL, UV, EF ,GF, OC,Ph. (Make: Numeric / APC/ VERTIV) LOAD OF OT ,ICU ) as per direction of Engg.-in-Charge. Warrentee period of all accessories and component and system must be 2 years and compelete test certificate must be submitted along with ups including component list and SLD.
12S/F of PCB for 400/350 watt sports light of make - Bajaj / Equivalent
13Dressed seasoned sal wood work framed and fixed ( Wrought and put up ) in burgahs, rafters and posts per 1cum.
14Providing & fixing 19mm thick BWR Plywood including cutting to proper sizes,fixing in position including all cost of materials, all labour & T&P etc. all complete.
15Providing and installation of Impact sports 65 Vinyl Sheet Flooring manufactured by Tarkett/Equivalant with a nominal thickness of 6.5 mm as per EN ISO 24346 and width of 2m as per EN ISO 24341. Impact sports 65 shall conform to EN 14001. The wear surface shall haveTop Clean XP treatment. Impact sports 65 shall have Resistance to wear as 1g as per EN ISO 5470-1, Resistance to impacts as per EN 1517 with no degradation, Tested for rolling loads as per EN 1569 and found compliant, Reaction to Fire as per Class Cfl-S1 as per EN 13501-1, tested for Resistance to Indentation and found compliant as per EN 1516 norms, Vertical Deformation value of P1 as per EN 14809, Shock absorption value of P1 as per EN 14808, Friction compliant as per EN 13036-4. The product should provide acoustical improvement of less than or equal to 65 dB - Class A as per EN 16205. The product does not contain Pthalate based plasticizer and emission rate of VOC is very low, measured after 28 days. TVOC and formaldehyde emissions are below 10/m3. It is 100percent Recyclable with 23percent recycled content and 100% REACH compliant.including cost of all materials, labour, conveyance, sundries, T&P, complete as per direction of Engineer-in-Charge.
16Cement concrete (1:3:6) with 4cm size hard granite cb metal including watering curing and cost of all labour T and P etc complete.
17Supplying & laying of precast interlocking concrete blocks of 80mm thick of approved design and filling the joints with sand on the prepared surface including cost of all chargesetc.complete as per MORD Specification. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57325062
AUTHORITY Government Departments
TENDER VALUE 25.38 Lakhs
LAST DATE 10-09-2026
Authority
Authority Name Road And Building Department
Work Description Tender for Supply Installation Testing and Commissioning of Arena Light Fitting, Outdoor Hanging Light, 60Kva Servo Stabilizer And Ups, Repair Of Wooden Block Flooring In Badminton Arena And Repair Of Paver Block Of Approach Road In Mpis, Kesinga Of Kalahandi District Buildings.
Basic Detail
Tender No BC KLD-05/2026-27
Bidding Type Tender
Location
City Kalahandi
State Odisha
Key Dates
Publish Date 03 Sep 2026
Submission Date 10 Sep 2026
Open Date 11 Sep 2026
Finance
Tender Value 25.38 Lakhs
Tender Fee 6000
EMD 25381
Exemption Available
Document List
30b114e3-d94e-496c-9f1f-f5550610f7ce.html
BOQ_608001.xls
Tendernotice_1 (14).pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Sep 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 6 days

Tender Documents

Download All (ZIP) ↓
html

30b114e3-d94e-496c-9f1f-f5550610f7ce.html

xls

BOQ_608001.xls

pdf

Tendernotice_1 (14).pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders