Drinking Water Supply and Sanitation Government Departments Closing in 10 days TDR #57325059

Tender For Design, Drawing, Construction, Testing & Commissioning Of Sewerage System, 70 Kld Sewage Treatment Plant (Stp) & 10 Kld Effluent Treatment Plant (Etp) For Community Health Centre (Chc) In G. Udayagiri Including Operation & Maintenance For

Issued by Government Departments · Kandhamal, Odisha
Tender Value
2.85 Crore
Estimated cost
Bid Submission
23 Sep 2026
10 days left
EMD
2.85 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kandhamal → Odisha
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Design, Drawing, Construction, Testing & Commissioning Of Sewerage System, 70 Kld Sewage Treatment Plant (Stp) & 10 Kld Effluent Treatment Plant (Etp) For Community Health Centre (Chc) In G. Udayagiri Including Operation & Maintenance For A Period Of Five Years

BOQ

Name of Work:- Design, Drawing, Construction, Testing & Commissioning of Sewerage System, 70 KLD Sewage Treatment Plant (STP) & 10 KLD Effluent Treatment Plant (ETP) for Community Health Centre (CHC) in G. Udayagiri including Operation & Maintenance for a period of Five Years
Sl. No. Item Description
1Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking into pieces not exceeding 0.02 cum in volume, and stacking serviceable materials at designated locations and disposing of dismantled materials up to a lead of 1000 metres, including stacking serviceable and unserviceable materials separately, complete as per the direction of the Engineer-in-Charge.
2Dismantling of cement concrete paver block flooring/pavement, including removal of paver blocks and bedding layer, sorting and stacking of serviceable materials, disposal of rubbish within specified lead, as directed by Engineer-in-Charge.
3Earthwork excavation in all kind of soil and hard rock / laterite rock.For laying of waste water pipe line (SWR (Type-B) Pipe)Supplying all labours and T&P for earth work in all kind of soil within 50mtr intitial lead including rough dressing and breaking of clods maximum 5cmto 7cm size and laying in layers not exceeding 0.30mtr in depth as per direction of Engineer -in -charge.Upto 1.50 mtr. Depth
4Excavation of foundation in laterite rock or any hard rock(other than granite )removed by chiselling including dressing and leveling the bed not exceeding 1.5mtr depth and depositing the soil within 50mtr initial lead as per specification approved by the Deptt. Upto 1.50 mtr. Depth
5Cutting in disintegrated rock not requiring blasting including dressing and leveling the bed not exceeding 1.5mtr depth and depositing the soil within 50mtr initial lead as per specification approved by the Deptt. Beyond 1.50 - 3.00 mtr. Depth
6For laying of Waste water pipe line from Inspection chamber to manhole chamber (DWC Pipe)Supplying all labours and T&P for earth work in all kind of soil within 50mtr inttial lead including rough dressing and breaking of clods maximum 5cmto 7cm size and laying in layers not exceeding 0.30mtr in depth as per direction of Engineer -in -charge. Upto 1.50 mtr. Depth
7Excavation of foundation in laterite rock or any hard rock(other than granite) removed by chiselling including dressing and leveling the bed not exceeding 1.5mtr depth and depositing the soil within 50mtr initial lead as per specification approved by the Deptt. Upto 1.50 mtr. Depth
8Cutting in disintegrated rock not requiring blasting including dressing and leveling the bed not exceeding 1.5mtr depth and depositing the soil within 50mtr initial lead as per specification approved by the Deptt. Beyond 1.50 - 3.00 mtr. Depth
9For laying of Waste water pipe line from MH to MH & MH to STP (RCC NP3 Hume Pipe)Supplying all labours and T&P for earth work in all kind of soil within 50mtr inttial lead including rough dressing and breaking of clods maximum 5cmto 7cm size and laying in layers not exceeding 0.30mtr in depth as per direction of Engineer -in -charge.Upto 1.50 mtr.
10Excavation of foundation in laterite rock or any hard rock (other than granite) removed by chiselling including dressing and leveling the bed not exceeding 1.5mtr depth and depositing the soil within 50mtr initial lead as per specification approved by the Deptt. Upto 1.50 mtr. Depth
11Cutting in disintegrated rock not requiring blasting including dressing and leveling the bed not exceeding 1.5mtr depth and depositing the soil within 50mtr initial lead as per specification approved by the Deptt. Beyond 1.50 - 3.00 mtr. Depth
12For construction of Manhole chamberSupplying all labours and T&P for earth work in all kind of soil within 50mtr inttial lead including rough dressing and breaking of clods maximum 5cmto 7cm size and laying in layers not exceeding 0.30mtr in depth as per direction of Engineer -in -charge. Upto 1.50 mtr. Depth (Manhole 1.2 x 0.9 m Depth)
13Upto 1.50 mtr. Depth (Manhole 1.2 x 1.67 m Depth)
14Excavation of foundation in laterite rock or any hard rock(other than granite )removed by chiselling including dressing and leveling the bed not exceeding 1.5mtr depth and depositing the soil within 50mtr initial lead as per specification approved by the Deptt. Upto 1.50 mtr. Depth (Manhole 1.2 x 0.9 m Depth)
15Upto 1.50 mtr. Depth (Manhole 1.2 x 1.67 m Depth)
16Cutting in disintegrated rock not requiring blasting including dressing and leveling the bed not exceeding 1.5mtr depth and depositing the soil within 50mtr initial lead as per specification approved by the Deptt. Beyond 1.50 - 3.00 mtr. Depth (Manhole 1.2 x 1.67 m Depth)
17Pipe BeddingProviding and laying sand bedding for sewer line trenches, including watering, ramming and consolidation by punners, complete with an initial lead of 50 metres as per specification and direction of Engineer-in-Charge.
18Construction of granular sub base by providing closed gradded granular Bedding materials as per table 400-1 spreading in uniform layers with mortor grader on prepared surface, mixing by in place method with rovator at OMC and campacting with vibratory roller to achieve the desired density complete as per clause 401 of MoSRT&H specification for road & bridge work etc complete.
19Providing and laying cement concrete in proportion 1:3:6 using 40 mm CBHG metal, in floor / bedding / base as required, including cost, conveyance, royalties, taxes of all materials, labour charges, mixing, laying, watering and curing, complete as per specification and direction of the Engineer-in-Charge.
20Supplying all materials, labour, T & P for refilling the trenches with Sand in layers of 300mm thick, including watering, ramming and consolidation, etc complete as per specification and direction of the Engineer-in-Charge.
21Disposal of debris/surplus excavated material to the site about 5km away from the work site, complete as per standard detailed technical specifications and approved design and drawings, including hire charges of machineries, loading and unloading charges, with all lead and lift and any other incidental charges, complete direction of Engineer-in-charge.
22Supplying all materials, labour, T&P for construction of circular type manholes with cover slab of Reinforced cement concrete M25,HD 20 precast manhole cover and ring, bottom slab & shaft made of Reinforced cement concrete M25 below 1.5m upto required depth with graded granite stone aggregate, foundation concrete(1:3:6) using graded HG stone aggregate 40mm nominal size, inside plastering 6mm thick (1:4) finished smooth with neat cement punning, outside plaster 12mm thick(1:4) and making benching with cement concrete M25 using graded granite stone aggregate, making smooth to the surface of benching and channel, testing & commissioning, lighting, watch & ward etc., all complete as per approved design & drawing & direction of Engineer in charge. Size:- 1.20 x 0.90mtr (Circular)
23Every Additional Depth of 0.10 mtr or part there of upto 1.50 mtr.
24Size:- 1.20 x 1.67mtr (Circular)
25Every Additional Depth of 0.10 mtr or part there of upto 2.30 mtr.
26Supplying all materials,labour and T&P for Construction of Gully trap with R.C.P.C. top slab in (1:1.5:3 ) mix with inside plaster 12mm. thick with cement mortar (1:3) finished with neat cement punning, 12mm. thick out side plaster (1:3), flyash brick work with flyash bricks with crushing strength not less than 75kg/sqcm. in cement mortar (1:3) finished smooth complete as per specification & direction of Engineer in charge. Size 250 x 250 x 675 mm
27Supplying all materials,labour and T&P for Constructing Inspection chamber with top slab in (1:1.5:3 ) mix & R.C.P.C. with inside plaster 12mm. thick with cement mortar (1:3) finished with neat cement punning, 12mm. thick out side plaster (1:3), flyash brick work with flyash bricks with crushing strength not less than 75kg/sqcm. in cement mortar (1:3) finished smooth complete as per specification & direction of Engineer in charge. Inspection Chamber 0.75 x 0.75 x 0.45 M
28Every Additional Depth of 0.10 mtr or part thereof
290.75 x 0.75 x 0.75 M
30Every Additional Depth of 0.10 mtr or part thereof
31Supplying all materials,labour and T&P for Re-Construction of damaged Inspection chamber with R.C.P.C. top slab in (1:1.5:3) mix with inside plaster 12mm. thick with cement mortar (1:3) finished with neat cement punning, 12mm. thick out side plaster (1:3), flyash brick work with flyash bricks with crushing strength not less than 75kg/sqcm. in cement mortar (1:3) finished smooth complete as per direction of Engineer-in-charge.0.75 x 0.75 x 0.45 M
32Every Additional Depth of 0.10 mtr or part thereof
330.75 x 0.75 x 0.75 M
34Every Additional Depth of 0.10 mtr or part thereof
35Supply, delivery & laying the following size of ISI marked PVC SWR S/S house sewer pipes (ISI Type - B) of approved diameter and rubber ring gasket and all other materials, labour, T & P, and lowering the pipes in to the trench, aligning, laying to approved level or slope as per P.H. specification and direction of Engineer-in-charge.90mm OD SWR Pipe for interconnectiom between IC & MH
36110mm OD SWR Pipe Pipe for interconnection between IC & MH
37160mm OD SWR Pipe Pipe for interconnection between IC & MH
38Providing, supplying, lowering and Hydraulic Testing instandard length (PE material) DWC pipe Structured-Wall plastic piping system for non pressure underground drainage and sewerage with smooth internal & corrugated external surface confirming to IS16098:Part-2 2013with spigot or plain endwith necessary jointing material coupler including transportation and freight charges, inspection charges, loading and unloading charges, conveyance to departmental store and stacking the same in closed shadeduly protecting from direct sun ray and rains excluding GST levied by Gol and GoM in all respect , etc. complete. Best NABL Approved Vendor tets Report submitted and Approved by Client engineer Incharge. PE / DWC SN-8150 mm Dia.
39Providing and supplying ISI standard HDPE / DWC specials / specials such as bend,tee, all angleand other on site required Specails excluding GST levied by GOI & GOM in all respect, railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store/site,unloading stacking etc. complete as per direction of Engineer-in-charge. 100 mm to 200 mm dia
40Supply and delivery of the following sizes of sulphate Resistant Cement RCC pipes of NP3 class confirming to IS 458, 1988 in Standard lengths wih socket and spigot ends with Suitable rubber rings, lowering in the ready made trenches, laying true to alignment and gradient, jointing with rubber rings, testinng as per the specifications including cost and conveyance of all materials to site, labour charges, all other incidental and operational charges etc, complete as per the direction of Engineer in chief.200 mm dia
41DEWATERINGDewatering of excavated trenches and pools of water in building trenches / pipeline trenches, well works by using pumps and other devices, including disposal of water to a safe distance as directed by the Engineer-in-Charge, complete as per specification.
42BARRICADINGProviding and fixing minimum 50 mm dia Bamboo for covering the barricading in one/two rows one above another and painiting in red and white sheets as per the specifications and direction of Engineer in charge with proper fixing arrangements with Gl implet washers nuts & bolts complete in all respect.
43Supplying all labour, tools & plants for rigid & smooth shoring and shuttering with wooden planks of suitable thickness, hoisting & placing in position of wooden planks and runner, bracing with wooden posts and fixing with sutiable wooden runner etc. wherever necessary at suitable intervals, including cost of all materials, royality, taxes, conveyance of all materials to site and installing in trench on both side upto required depth to retain earth for sewer lines and manholes, dismantling the shoring and shuttering etc. all complete as per direction of Engineer-in-charge.Lift upto 1.50 m depth
44ROAD RESTORATIONCC ROADCement concrete (1:3:6) with 40mm. Size crusher broken hard Granite 1 metal including cost of all labour m³ ,materials with all taxes, lead, T & P etc all complete.
45Cement concrete (1:1.5:3)with 12mm size crusher broken hard granite chips including cost of all labour, materials with all taxes, lead, T & P etc all complete.
46Providing and laying of 60mm thick factory made cement concrete interlocking paver block of M30 grade and approved make, colour and size made by block making machine with strong vibratory compaction of approved size design and shape laid in required colour and pattern over and including 50mm thick compacted bed of sand etc complete coarse sand , filling the joints with the sand etc all complete including cost conveyance, royalties and taxes of all materials and cost of all labour, etc. complete as directed by Engineer in charge.material for reuse
47new material for restoration
48R.C.C DRAINSupplying all material, labour, T & P for construction of R.C.C surface drain for disposal of rain water etc from the premises of ETP / STP (0.25m width x 0.30m depth) etc all complete as per approved design and drawings and as per direction of Engineer-in-charge.
49PLANT CUM SCADA ROOMSupplying all material, labour, T & P for construction of Plant cum SCADA room using R.C.C Column, R.C.C Beam, Lintel, Chajja, Roof Slab, Fly ash brick work in C.M( 1:6), Cement plaster & painting works with lead and lift of all materials to site and etc all complete as per approved design and drawings and as per direction of Engineer-in-charge.
50CHEMICAL STORAGE ROOMSupplying all material, labour, T & P for construction of Chemical storage room using R.C.C Column, R.C.C Beam, Lintel, Chajja, Roof Slab, Fly ash brick work in C.M( 1:6), Cement plaster & painting works with lead and lift of all materials to site as per approved design and drawings and as per direction of Engineer-in-charge.
51COMPOUND WALLSupplying all material, labour, T & P for Construction of RCC framed Boundary Wall with fly ash brick including earthwork, sand filling, CC (1:3:6), R.C.C work, brick work, plastering, painting, etc. all complete as per design and drawings and per direction and drawing to be approved by Engineer-in-charge.
52Supplying all material, labour, T & P for provision of SS Gate including construction of 2 nos. R.C.C pillar, plastering, finishing etc all complete as per approved drawings and direction of Engg.-in-charge.2 Leaf SS Gate (size 6.0M X 1.8 M Ht.)- 1 No.1 Leaf SS Gate (size 1.3M X 1.8 M Ht.)- 1 No.
53Construction of STP & ETPDesigning, drawing, supplying, constructing, testing & commissioning of Effluent Treatment Plant (ETP) & Sewage Treatment Plant (STP) of required capacity and appropriate technology (MBBR / MBR/ Advanced MBBR/ SABRE)) including all civil, electro-mechanical works, tertiary treatment system, automation etc all complete to achieve desired effluent quality as per NGT norms. (Excluding cost of SCADA system, PLC, plant room, chemical storage room, yard lighting, compound wall, external electrification, treated water storage sump and re-use/disposal arrangements) (Technology to be adopted as approved by Engineer-in-Charge) ETP- 10 KLD STP-70 KLD
54Supply, Installation, Testing and Commissioning of Multiparametric Online Continuous Effluent Monitoring System having facilities for pH, COD, BOD TSS analyzer as per technical specifications attached including ( One) year guarantee. Make XYLEM /SCAN /HORIBA /Equivalent make with approval of authority.
55Supply,Installation & Commissioning of SCADA software (Make-Schiender/Simens/Rockwell/Equivalent make with approval of authority) with Graphical processor visualisation Advanced alarm management,historical and Real time trending,Built-inreporting, Stastical process control,Multithreaded citect VBA and Cicode programming language with 2048 Tag SCADA Software (ES+OS) (Make-Schiender/Simens/Rockwell/Equivalent make with approval of authority),1KVa online Ups with 30Min batery backup- 1Nos,CPU Having Preloaded win-10 Proffessional, I3-10gen 2.4 Ghz Prrocessor, DDR4 8gb Ram, 500 gb 7200 Rpm HDD-1 Nos (Make-HP, DELL, LENOVO), USB based keyboard - 1Nos,USB based Optical Mouse- 1Nos,43'' LED monitor - 1Nos,A4 size laserPrinter - 1Nos,Wooden Computer table - 1 Nos ,Preparation of P&I diagram, Creation of Multi visualization screen for Process control,alarm managenent, Historical and realtime process trend, Daily reporting etc complete as per requirement & direction of Engineer - in - Charge. (Including license key)
56Supply,installation & commissioning of PLC Panel with following technical specification i,e. Enclosure: 800x800x2100mm-01 No with double door & lock, CPU should have 1 MB program memory with extended memory slut ,Redundand-24VDC,SMPS 10Amp along with 24V DC SPD,IO count as DI-16,DO-20,AI-20,AO-08 & MODBUS-10 subsystem shall be of same series as CPU,10\\" Panel Mounted HMI,Modem should have support MQTT Protocol by default, 24volt DC Industrial switch with minimum 6 eathernate, 4 SFP Port each AI shall be equiped with sutitable signal isolator of 20 Nos & surge protection device 20 nos LIU Isolater, 230Volt AC/230volt AC torroidal transformer,1KVA 230V AC industrial grade UPS of 8 hrs backup to charge 3 nos 12 VDC 65 AH Battery ,DP MCB of Adequate current capacity,LED tube light 10\\" 5 watt,door limit switch,Fan 6\\" with louver,4 sqmm straight through terminal & fuse terminal 90 nos, with PE & EE.The Approved Make : (Make:- Siemens,Schnider,ABB,Mitsubishi/Equivalent make with approval of authority) including cost of material with all taxes transporataion to Site/Storage with insurance.Programme to be handed over with upload & download facilities for departmental use.
57Treated water storage sumpConstruction of Treated water storage sump of required capacity using RCC including plastering, painting, epoxy treatment, etc. all complete as per approved design and drawings and as per direction of Engineer-in-charge.For 30000 ltr.
58Supply, Installation, Testing and Commissioning of Submersible pump set with required control panel and electrical installation all complete as per approved design and drawings and as per direction of Engineer-in-charge. (1W + 1S)
59Providing and supplying in standard lengths High Density Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc complete as per direction of Engineer-in-charge.75 mm dia HDPE (PE-80) pipe
6090 mm dia HDPE (PE-80) pipe
61110 mm dia HDPE (PE-80) pipe
62YARD LIGHTINGSupplying all material, labour, T & P for providing external street / area lighting with fitting and fixing of 90W LED light mounted on 6mtr. Long tubular GI pole with brackets with required controlled system etc all complete as per relevant electrical specification and direction of Engineer-in-charge.
63EXTERNAL ELECTRIFICATIONProviding for supply, installation, testing and commissioning of 3-phase, 11/0.4 kV LT power supply system including 25 KVA, 11/0.4 kV transformer with all associated materials, accessories, fittings and allied works complete in all respects as per relevant Electrical/IS specifications and as required by the concerned Electricity Distribution Utility. The provision shall also include LT overhead line up to the transformer yard, including conductor, GI poles, stays, insulators, cable from transformer to panel room and all other allied materials and works as required by TPCODL/TPSODL/TPWODL/TPNODL, including necessary supervision, inspection and approval charges. (Work shall be executed under the supervision of TPCODL/ TPSODL/ TPNODL/ TPWODL Authorities as per their estimate and payment shall be made accordingly as per actual).Transformer capacity -25 kVA
64DG SETDesign, engineering, procurement of materials and bought out components, manufacturing, assembly at shop, inspection, testing and painting at manufactures works, packing, supply, unloading/ transportation/ handling/ storage at site, assembly at site, installation including touch-up painting, hook-up, pre-commissioning, commissioning, inspection and testing of the complete of the following capacity (prime power) DG sets along with AMF panels. Acoustic enclosure, supply of all erection & commissioning spares, special tools and tackles (as required), instrumentation, all auxiliaries, Exhaust system & silencer, Fuel tank, Fuel piping etc all complete including RCC foundation,DG set Shed,Chemical earthing 4 nos,Al power cable of required length,trial run with required amount of diesel as per directrion of EIC in complience with CPCB IV+ norms. (Make:- Mahindra Power/ Kirloskar/Ashok Leyland/Sterling/Jackson/ Cumin Powers/ Greaves Cotton/ Greaves/TMTL/Captiva/Equivalent make with approval of the authority)DG capacity - 25 kVA
65Design, manufacture, supply, inspection, handling, installation, testing and commissioning of floor-mounted, extensible type, cubical Main LT Panel fabricated out of 1.6/2.0 mm thick CRCA sheet steel, dust and vermin proof, front operated construction, enclosure protection class IP-42, conforming to IEC 60439. The panel shall be surface treated with 9-tank process and provided with top/bottom removable gland plates, double compression type cable glands, earth bus, hinged and lockable doors, and all internal interconnections complete as required for plant operation, as per the direction of the Engineer-in-Charge.
665 years of Operation & MaintenanceWaste Water Collection System Operation and Maintenance for the first 5 years from Commissioning of the Work and Treatment plant O&M, including deployment of Skilled Man Power, Chemical consumption, operation consumables for ETP & STP plant operation.For 1st Year O & M
67For 2nd Year O & M
68For 3rd Year O & M
69For 4th Year O & M
70For 5th Year O & M Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57325059
AUTHORITY Government Departments
TENDER VALUE 2.85 Crore
LAST DATE 23-09-2026
Authority
Authority Name Public Health Engineer Organisation
Work Description Tender for Design, Drawing, Construction, Testing & Commissioning Of Sewerage System, 70 Kld Sewage Treatment Plant (Stp) & 10 Kld Effluent Treatment Plant (Etp) For Community Health Centre (Chc) In G. Udayagiri Including Operation & Maintenance For A Period Of Five Years
Basic Detail
Tender No EICPH- 04/2026-27 Dt.28.08.2026
Bidding Type Tender
Location
City Kandhamal
State Odisha
Key Dates
Publish Date 03 Sep 2026
Submission Date 23 Sep 2026
Open Date 24 Sep 2026
Finance
Tender Value 2.85 Crore
Tender Fee 10000
EMD 2.85 Lakhs
Exemption Available
Document List
BOQ_607929.xls
cf068200-192f-4e55-a3aa-5d75e04601be.html
DTCNGUDAYAGIRI.pdf
Tendernotice_1 (14).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Sep 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 11 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_607929.xls

html

cf068200-192f-4e55-a3aa-5d75e04601be.html

pdf

DTCNGUDAYAGIRI.pdf

pdf

Tendernotice_1 (14).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders