Defence Statutory Bodies & Commissions/Committees Closing in 8 days TDR #57323944

Bids Are invited for S And F Of Lt Ug Cable Xlpe At 43 Weu Ramgarh Jaisalmer

Issued by Statutory Bodies & Commissions/Committees · Jaisalmer, Rajasthan
Tender Value
Ref. Documents
Estimated cost
Bid Submission
14 Sep 2026
8 days left
EMD
1.40 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaisalmer → Rajasthan
EMD Exemption
Available
Quantity
28994

Project Description

Bids Are invited for S And F Of Lt Ug Cable Xlpe At 43 Weu Ramgarh Jaisalmer Supply Laying And Commissioning In Replacement Of Lt Ug Cable 4 Core X 16 Sqmm Xlpe Sheathed Pvc Insulated Screened Pvc Bedded Galvanized Steel Strip Of Wire Armd Electric Power As Per Atc , Supply Laying And Commissioning In Replacement Of Lt Ug Cable 3 Point 5 Core X 35 Sqmmxlpe Sheathed Pvc Insulated Screened Pvc Bedded Galvanized Steel Strip Of Wire Armoured As Per Atc , Supply Laying And Commissioning In Replacement Of Lt Ug Cable 3 Point 5 Core X 50 Sqmm Xlpe Sheathed Pvc Insulated Screened Pvc Bedded Galvanized Steel Strip Of Wire Armoured As Per Atc , Supply Laying And Commissioning In Replacement Of Lt Ug Cable 3 Point 5 Core X 70 Sqmm Xlpe Sheathed Pvc Insulated Screened Pvc Bedded Galvanized Steel Strip Of Wire Armoured As Per Atc , Supply Laying And Commissioning In Replacement Of Lt Ug Cable 3 Point 5 Core X 120 Sqmm Xlpe Sheathed Pvc Insulated Screened Pvc Bedded, Galvanized Steel Strip Of Wire Armoured As Per Atc , Supplying And Laying Unreinforced Precast Concrete Cable Cover Class Lv Typei Flat Size 250Mm X 150Mm X 40Mm Complete All As Specified And As Directed , Supply And Fixing In Replacement Energy Efficient Led Street Light Fitting Of 70W Pressure Die Cast Aluminum Housing Or Body Heat Resistant Clear Toughened Glass Better Optics For Uniform As Per Atc , Supply And Fix Junction Box In Replacement Made Out Of Frp With Ip 55 Or Ip 65 Protection Of Size Not Less Than 200 X 140 X 95 Mm Inside Dimension Having 5 Terminal Mounted On Din As Per Atc , Supply And Fixing In Replacement Connecting Elastomer Insulated Flat Sheathed Mutlicore Industrial Flexible Cable 1 Point 5 Sqmm 3 Corewith Bright Annealed Copper Conductor 1100V As Per Atc , Supply Erecting Steel Tubular Poles In Replacement Pcc Or Rcc Poles Complete With Cast Iron Base Plate Finial Taper Plug Bolt Nut Screw Complete All As Specified Type 410 Sp 31 Of 9M Long As Per Atc , Supply Only In Replacement Hv Bushing 11 Kv For Transfermores Up To Capacity 160 Kva Complete All As Specified And Directed , Supply Only In Replacement V Bushing 0 Point 433 Or 0 Point 415 Kv For Transformer Up To Rating 160 Kva Complete All As Specified And Directed , Supply Only In Replacement Hv Spindle Metal Part Made Out Of Brass With Nuts And Washer Complete For Transformer Of Capacity Upto 160 Kva Complete All As Specified And Directed , Supply Only In Replacement Lv Spindle Metal Part Made Out Of Brass With Nuts And Washers Complete For Transformer Of Capacity Upto 160 Kva Complete All As Specified And Directed , Supply Fill And Top Up New Transformer Oil Low Viscosity Type Of Dielectric Strength 35 To 40 Kv Breaking Voltage Confirming To Is Complete For Indoor Or Outdoor Transformer In Various Sub As Per Atc , S Andf In Replacement Silica Gel Breather Transparent Type With Silica Gel Complete Suitable For Up To 160 Kva Transformer Rating All As Specified , S And F In Replacement Dial Type Thermo Meter Of Minimum 10Mm Dia With Maximum Temperature Indicator For Transformer Of Capacity Up To 160 Kva All As Specified And Directed , Supply Only In Replacement Tap Changer Switch Complete With Handle For Transformer Of Capacity Upto 160 Kva , Supply Only In Replacement Fixed Contact Block Of Vcb 630 S 11 Kv Incl Taking Down Old Material , Supply Only In Replacement Support Insulator 75Mm Dia Of Vcb 630 S 11 Kv , Supply Only In Replacement Auxiliary Switch 6No Plus 6Nc Of Vcb 630 S 11 Kv , Supply Only In Replacement Solenoid Closing Coil 3 Or 110 V Dc Suitable For Type V 207G Vcb 630 A Vmx Breaker , Supply Fix And Connect In Replacement Announciator Suitable For 11 Kv Indoor Control Panel With Necessary Writing And Testing On Completion Complete All As Specified And Directed , Supply Only In Replacement Charging Motor For High Tension 11 Kv Vcb Panels 400 S Operated On 230 Volts Ac Or 30 Volts Dc As Per S Le Complete All As Specified And Directed By Eic , Supply Only In Replacement Upper Spout Ht 11 Kv Vcb As Per S Le And Fixing On Panel All As Required At Site Complete All As Specified And Directed , Supply Only In Replacement Male Contact Made Of Tinned Copper Vcb 11 Kv Made Of Brass As Per S Le And Fixing Testing All As Required And Directed At Site Complete All As Specified And Directed , S And F In Replacement Resin Or Epoxy Coated Air Cooled High Tension Current Transformer Of Dual Ratio Of 200 To 100 Or 5 S 10Va Burden Out Put Accuracy Clas 0 Point 5 Suitable For Rated As Per Atc , S And F In Replacement Over Current Earth Fault Relay Having Auxiliary Voltage 24 To 110 Volts Plus 15 Percent Ac Or Dc Complete All As Specified And Directed , S And F In Replacement Panel Lighting L With Holder With On Or Off Toggle Switch Complete All As Specified And Directed , S And F In Replacement Bakelite Hrc Fuses In Control Or Vcb Panels Complete All As Specified And Directed , S And F In Replacement Breaker Control Switch Suitable For 11 Kv Control Panel And Outdoor Vcbs Complete All As Specified And Directed Incl Taking Down Old Complete All As Specified And Directed , S And F In Replacement Digital Multifunctional Meter As Per Existing Or As Approved By The Ge Complete All As Specified And Directed , S And F In Replacement Selector Switch For Various Type Of Control Panels As Per Existing Complete All As Specified And Directed , S And F In Replacement Switch Air Break Gang Operated God Switch Outdoor Type Ht 11 Kv Triple Poles 200 S With Fixed Contacts Of Phosphorus Bronze And Moving Contacts Of Copper As Per Atc , S And F In Replacement Mild Steel Cross Arms Bracing Supports Cl S And Back Plates Fabricated From Structural Steel Section Incl Nuts Bolts Washers Bending Cold Or Hot Drilling Holes As Per Atc , Excavation In Trenches N Exc 1 Point 5M In Depth And Not Exc 1 Point 5M Wide For Laying Of Ug Cable Or Pole Etc And Getting Out Incl Forming Bottom Surface To Required Level And Gradient As Per Atc , Returning Filling In Excavated Soil Incl Spreading Leveling Watering And Well Ramming In Layers Not Exc 25Cm Thick Complete All As Specified , Removing Excavated Material Or Soil To A Distance N Exc 50M And Where Directed At A Level N Exc 1 Point 5 Above The Starting Point Complete All As Specified And As Directed By Engr In Charge , M And L For Sand Cushioning Dry In Trenches Or Ducts For Protection Of Ug Cables Below Above And Around The Ug Cable Laid In Trenches Of 23 Cm Spread Thickness As Per Atc , Plain Cement Concrete 1 Is To 4 Is To 8 Type D 2Using 40Mm Graded Stone Aggregate As In Foundation Of Poles Etc All As Specified , Plain Cement Concrete 1 Is To 2 Is To 4 Type B 1 Using 20Mm Graded Stone Aggregate For Pole Coping Etc All As Specified , Plain Cement Concrete 1 Is To 3 Is To 6 Type C 2 Using 40Mm Graded Stone Aggregate As In Foundation Of Pole Etc All As Specified , M And L In Replacement For Earthing Complete With Galvanized Steel Plate Electrode 60Cm X 60Cm X 6Mm Thick Buried Directly In Ground Earth Pit Not Less Than 2 Point 25 Meters Deep As Per Atc , Transporting Faulty Or Defective Transformer Rating Upto 160 Kva Ratio 11 Kv 0 Point 433 Or 0 Point 415 Kv To Contractor Workshop From Ramgarh Premises As Per Atc , M And L For Centrifusing Filteratin Or Dehydration Of Transformer Oil Incl Filter Action Using Automatic Centrifusing Machine Incl Armging Elect Supply For Operation Of Machine To Achieve As Per Atc , M And L For Painting Of Distribution Transformer Of Capacity Upto 63 Kva To 160 Kva With Two Coats Of Smoke Synthetic Enamel Paint Colour Or Shed Decided By Ge Externally After Necessary As Per Atc , Repair Or Overhauling To 11Kv Ht Control Panels Complete In And Incl The Following Repair Works As Per Atc , M And L Cable Route Indicator Duly Engraved With Lt Cable 1100V On Cast Iron Round Plate 150Mm Dia With Provision Of 500 Mm Long Min Single Leg Or Stand Of Flat Iron 50 X 6Mm Welded As Per Atc

BOQ

Sl. No. Item TitleItem Description
1Supply Laying and Commissioning in replacement of LT UG Cable 4 core x 16 sqmm XLPE sheathed PVC insulated screened PVC bedded galvanized steel strip of wire armd electric power as per ATCSupply Laying and Commissioning in replacement of LT UG Cable 4 core x 16 sqmm XLPE sheathed PVC insulated screened PVC bedded galvanized steel strip of wire armd electric power as per ATC
2Supply Laying and Commissioning in replacement of LT UG Cable 3 point 5 core x 35 sqmmXLPE sheathed PVC insulated screened PVC bedded galvanized steel strip of wire armoured as per ATCSupply Laying and Commissioning in replacement of LT UG Cable 3 point 5 core x 35 sqmmXLPE sheathed PVC insulated screened PVC bedded galvanized steel strip of wire armoured as per ATC
3Supply Laying and Commissioning in replacement of LT UG Cable 3 point 5 core x 50 sqmm XLPE sheathed PVC insulated screened PVC bedded galvanized steel strip of wire armoured as per ATCSupply Laying and Commissioning in replacement of LT UG Cable 3 point 5 core x 50 sqmm XLPE sheathed PVC insulated screened PVC bedded galvanized steel strip of wire armoured as per ATC
4Supply Laying and Commissioning in replacement of LT UG Cable 3 point 5 core x 70 sqmm XLPE sheathed PVC insulated screened PVC bedded galvanized steel strip of wire armoured as per ATCSupply Laying and Commissioning in replacement of LT UG Cable 3 point 5 core x 70 sqmm XLPE sheathed PVC insulated screened PVC bedded galvanized steel strip of wire armoured as per ATC
5Supply Laying and Commissioning in replacement of LT UG Cable 3 point 5 core x 120 sqmm XLPE sheathed PVC insulated screened PVC bedded, galvanized steel strip of wire armoured as per ATCSupply Laying and Commissioning in replacement of LT UG Cable 3 point 5 core x 120 sqmm XLPE sheathed PVC insulated screened PVC bedded, galvanized steel strip of wire armoured as per ATC
6Supplying and laying unreinforced precast concrete cable cover class LV typeI flat size 250mm x 150mm x 40mm complete all as specified and as directedSupplying and laying unreinforced precast concrete cable cover class LV typeI flat size 250mm x 150mm x 40mm complete all as specified and as directed
7Supply and fixing in replacement energy efficient LED street light fitting of 70W pressure die cast aluminum housing or body heat resistant clear toughened glass better optics for uniform as per ATCSupply and fixing in replacement energy efficient LED street light fitting of 70W pressure die cast aluminum housing or body heat resistant clear toughened glass better optics for uniform as per ATC
8Supply and fix junction box in replacement made out of FRP with IP 55 or IP 65 protection of size not less than 200 x 140 x 95 mm inside dimension having 5 terminal mounted on din as per ATCSupply and fix junction box in replacement made out of FRP with IP 55 or IP 65 protection of size not less than 200 x 140 x 95 mm inside dimension having 5 terminal mounted on din as per ATC
9Supply and fixing in replacement connecting elastomer insulated flat sheathed mutlicore industrial flexible cable 1 point 5 sqmm 3 corewith bright annealed copper conductor 1100V as per ATCSupply and fixing in replacement connecting elastomer insulated flat sheathed mutlicore industrial flexible cable 1 point 5 sqmm 3 corewith bright annealed copper conductor 1100V as per ATC
10Supply erecting steel tubular poles in replacement PCC or RCC poles complete with cast iron base plate finial taper plug bolt nut screw complete all as specified type 410 SP 31 of 9M long as per ATCSupply erecting steel tubular poles in replacement PCC or RCC poles complete with cast iron base plate finial taper plug bolt nut screw complete all as specified type 410 SP 31 of 9M long as per ATC
11Supply only in replacement HV bushing 11 KV for transfermores up to capacity 160 KVA complete all as specified and directedSupply only in replacement HV bushing 11 KV for transfermores up to capacity 160 KVA complete all as specified and directed
12Supply only in replacement V bushing 0 point 433 or 0 point 415 KV for transformer up to rating 160 KVA complete all as specified and directedSupply only in replacement V bushing 0 point 433 or 0 point 415 KV for transformer up to rating 160 KVA complete all as specified and directed
13Supply only in replacement HV spindle metal part made out of brass with nuts and washer complete for transformer of capacity upto 160 KVA complete all as specified and directedSupply only in replacement HV spindle metal part made out of brass with nuts and washer complete for transformer of capacity upto 160 KVA complete all as specified and directed
14Supply only in replacement LV spindle metal part made out of brass with nuts and washers complete for transformer of capacity upto 160 KVA complete all as specified and directedSupply only in replacement LV spindle metal part made out of brass with nuts and washers complete for transformer of capacity upto 160 KVA complete all as specified and directed
15Supply fill and top up new transformer oil low viscosity type of dielectric strength 35 to 40 KV breaking voltage confirming to IS complete for indoor or outdoor transformer in various sub as per ATCSupply fill and top up new transformer oil low viscosity type of dielectric strength 35 to 40 KV breaking voltage confirming to IS complete for indoor or outdoor transformer in various sub as per ATC
16S andF in replacement silica gel breather Transparent type with silica gel complete suitable for up to 160 KVA transformer rating all as specifiedS andF in replacement silica gel breather Transparent type with silica gel complete suitable for up to 160 KVA transformer rating all as specified
17S and F in replacement dial type thermo meter of minimum 10mm dia with maximum temperature indicator for transformer of capacity up to 160 KVA all as specified and directedS and F in replacement dial type thermo meter of minimum 10mm dia with maximum temperature indicator for transformer of capacity up to 160 KVA all as specified and directed
18Supply only in replacement tap changer switch complete with handle for transformer of capacity upto 160 KVASupply only in replacement tap changer switch complete with handle for transformer of capacity upto 160 KVA
19Supply only in replacement fixed contact block of VCB 630 Amps 11 KV incl taking down old materialSupply only in replacement fixed contact block of VCB 630 Amps 11 KV incl taking down old material
20Supply only in replacement support insulator 75mm dia of VCB 630 amps 11 KVSupply only in replacement support insulator 75mm dia of VCB 630 amps 11 KV
21Supply only in replacement auxiliary switch 6NO plus 6NC of VCB 630 Amps 11 KVSupply only in replacement auxiliary switch 6NO plus 6NC of VCB 630 Amps 11 KV
22Supply only in replacement solenoid closing coil 3 or 110 V DC suitable for type V 207G VCB 630 A VMX BreakerSupply only in replacement solenoid closing coil 3 or 110 V DC suitable for type V 207G VCB 630 A VMX Breaker
23Supply fix and connect in replacement announciator suitable for 11 KV indoor control panel with necessary writing and testing on completion complete all as specified and directedSupply fix and connect in replacement announciator suitable for 11 KV indoor control panel with necessary writing and testing on completion complete all as specified and directed
24Supply only in replacement charging motor for high tension 11 KV VCB panels 400 Amps operated on 230 Volts AC or 30 volts DC as per sample complete all as specified and directed by EICSupply only in replacement charging motor for high tension 11 KV VCB panels 400 Amps operated on 230 Volts AC or 30 volts DC as per sample complete all as specified and directed by EIC
25Supply only in replacement upper spout HT 11 KV VCB as per sample and fixing on panel all as required at site complete all as specified and directedSupply only in replacement upper spout HT 11 KV VCB as per sample and fixing on panel all as required at site complete all as specified and directed
26Supply only in replacement male contact made of tinned copper VCB 11 KV made of brass as per sample and fixing testing all as required and directed at site complete all as specified and directedSupply only in replacement male contact made of tinned copper VCB 11 KV made of brass as per sample and fixing testing all as required and directed at site complete all as specified and directed
27S and F in replacement resin or epoxy coated air cooled high tension current transformer of dual ratio of 200 to 100 or 5Amps 10VA burden out put accuracy clas 0 point 5 suitable for rated as per ATCS and F in replacement resin or epoxy coated air cooled high tension current transformer of dual ratio of 200 to 100 or 5Amps 10VA burden out put accuracy clas 0 point 5 suitable for rated as per ATC
28S and F in replacement over current earth fault relay having auxiliary voltage 24 to 110 volts plus 15 percent AC or DC complete all as specified and directedS and F in replacement over current earth fault relay having auxiliary voltage 24 to 110 volts plus 15 percent AC or DC complete all as specified and directed
29S and F in replacement panel lighting lamp with holder with on or off toggle switch complete all as specified and directedS and F in replacement panel lighting lamp with holder with on or off toggle switch complete all as specified and directed
30S and F in replacement bakelite HRC fuses in control or VCB panels complete all as specified and directedS and F in replacement bakelite HRC fuses in control or VCB panels complete all as specified and directed
31S and F in replacement breaker control switch suitable for 11 KV control panel and outdoor VCBs complete all as specified and directed incl taking down old complete all as specified and directedS and F in replacement breaker control switch suitable for 11 KV control panel and outdoor VCBs complete all as specified and directed incl taking down old complete all as specified and directed
32S and F in replacement digital multifunctional meter as per existing or as approved by the GE complete all as specified and directedS and F in replacement digital multifunctional meter as per existing or as approved by the GE complete all as specified and directed
33S and F in replacement selector switch for various type of control panels as per existing complete all as specified and directedS and F in replacement selector switch for various type of control panels as per existing complete all as specified and directed
34S and F in replacement switch air break gang operated GOD switch outdoor type HT 11 KV triple poles 200 Amps with fixed contacts of phosphorus bronze and moving contacts of copper as per ATCS and F in replacement switch air break gang operated GOD switch outdoor type HT 11 KV triple poles 200 Amps with fixed contacts of phosphorus bronze and moving contacts of copper as per ATC
35S and F in replacement mild steel cross arms bracing supports clamps and back plates fabricated from structural steel section incl nuts bolts washers bending cold or hot drilling holes as per ATCS and F in replacement mild steel cross arms bracing supports clamps and back plates fabricated from structural steel section incl nuts bolts washers bending cold or hot drilling holes as per ATC
36Excavation in trenches n exc 1 point 5M in depth and not exc 1 point 5M wide for laying of UG cable or pole etc and getting out incl forming bottom surface to required level and gradient as per ATCExcavation in trenches n exc 1 point 5M in depth and not exc 1 point 5M wide for laying of UG cable or pole etc and getting out incl forming bottom surface to required level and gradient as per ATC
37Returning filling in excavated soil incl spreading leveling watering and well ramming in layers not exc 25cm thick complete all as specifiedReturning filling in excavated soil incl spreading leveling watering and well ramming in layers not exc 25cm thick complete all as specified
38Removing excavated material or soil to a distance n exc 50m and where directed at a level n exc 1 point 5 above the starting point complete all as specified and as directed by Engr in ChargeRemoving excavated material or soil to a distance n exc 50m and where directed at a level n exc 1 point 5 above the starting point complete all as specified and as directed by Engr in Charge
39M and L for sand cushioning dry in trenches or ducts for protection of UG cables below above and around the UG cable laid in trenches of 23 cm spread thickness as per ATCM and L for sand cushioning dry in trenches or ducts for protection of UG cables below above and around the UG cable laid in trenches of 23 cm spread thickness as per ATC
40Plain cement concrete 1 is to 4 is to 8 type D 2using 40mm graded stone aggregate as in foundation of poles etc all as specifiedPlain cement concrete 1 is to 4 is to 8 type D 2using 40mm graded stone aggregate as in foundation of poles etc all as specified
41Plain Cement concrete 1 is to 2 is to 4 type B 1 using 20mm graded stone aggregate for pole coping etc all as specifiedPlain Cement concrete 1 is to 2 is to 4 type B 1 using 20mm graded stone aggregate for pole coping etc all as specified
42Plain cement concrete 1 is to 3 is to 6 Type C 2 using 40mm graded stone aggregate as in foundation of pole etc all as specifiedPlain cement concrete 1 is to 3 is to 6 Type C 2 using 40mm graded stone aggregate as in foundation of pole etc all as specified
43M and L in replacement for earthing complete with galvanized steel plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2 point 25 meters deep as per ATCM and L in replacement for earthing complete with galvanized steel plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2 point 25 meters deep as per ATC
44Transporting faulty or defective transformer rating upto 160 KVA ratio 11 KV 0 point 433 or 0 point 415 KV to contractor workshop from Ramgarh premises as per ATCTransporting faulty or defective transformer rating upto 160 KVA ratio 11 KV 0 point 433 or 0 point 415 KV to contractor workshop from Ramgarh premises as per ATC
45M and L for centrifusing Filteratin or dehydration of transformer oil incl filter action using automatic centrifusing machine incl armging elect supply for operation of machine to achieve as per ATCM and L for centrifusing Filteratin or dehydration of transformer oil incl filter action using automatic centrifusing machine incl armging elect supply for operation of machine to achieve as per ATC
46M and L for painting of distribution transformer of capacity upto 63 KVA to 160 KVA with two coats of smoke synthetic enamel paint colour or shed decided by GE externally after necessary as per ATCM and L for painting of distribution transformer of capacity upto 63 KVA to 160 KVA with two coats of smoke synthetic enamel paint colour or shed decided by GE externally after necessary as per ATC
47Repair or overhauling to 11KV HT control panels complete in and incl the following repair works as per ATCRepair or overhauling to 11KV HT control panels complete in and incl the following repair works as per ATC
48M and L cable route indicator duly engraved with LT Cable 1100V on cast iron round plate 150mm dia with provision of 500 mm long Min single leg or stand of flat iron 50 x 6mm welded as per ATCM and L cable route indicator duly engraved with LT Cable 1100V on cast iron round plate 150mm dia with provision of 500 mm long Min single leg or stand of flat iron 50 x 6mm welded as per ATC

AI Tender Summary

OUR REF NO 57323944
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 14-09-2026
Authority
Authority Name Indian Army
Work Description Bids Are invited for S And F Of Lt Ug Cable Xlpe At 43 Weu Ramgarh Jaisalmer Supply Laying And Commissioning In Replacement Of Lt Ug Cable 4 Core X 16 Sqmm Xlpe Sheathed Pvc Insulated Screened Pvc Bedded Galvanized Steel Strip Of Wire Armd Electric Power As Per Atc , Supply Laying And Commissioning In Replacement Of Lt Ug Cable 3 Point 5 Core X 35 Sqmmxlpe Sheathed Pvc Insulated Screened Pvc Bedded Galvanized Steel Strip Of Wire Armoured As Per Atc , Supply Laying And Commissioning In Replacement Of Lt Ug Cable 3 Point 5 Core X 50 Sqmm Xlpe Sheathed Pvc Insulated Screened Pvc Bedded Galvanized Steel Strip Of Wire Armoured As Per Atc , Supply Laying And Commissioning In Replacement Of Lt Ug Cable 3 Point 5 Core X 70 Sqmm Xlpe Sheathed Pvc Insulated Screened Pvc Bedded Galvanized Steel Strip Of Wire Armoured As Per Atc , Supply Laying And Commissioning In Replacement Of Lt Ug Cable 3 Point 5 Core X 120 Sqmm Xlpe Sheathed Pvc Insulated Screened Pvc Bedded, Galvanized Steel Strip Of Wire Armoured As Per Atc , Supplying And Laying Unreinforced Precast Concrete Cable Cover Class Lv Typei Flat Size 250Mm X 150Mm X 40Mm Complete All As Specified And As Directed , Supply And Fixing In Replacement Energy Efficient Led Street Light Fitting Of 70W Pressure Die Cast Aluminum Housing Or Body Heat Resistant Clear Toughened Glass Better Optics For Uniform As Per Atc , Supply And Fix Junction Box In Replacement Made Out Of Frp With Ip 55 Or Ip 65 Protection Of Size Not Less Than 200 X 140 X 95 Mm Inside Dimension Having 5 Terminal Mounted On Din As Per Atc , Supply And Fixing In Replacement Connecting Elastomer Insulated Flat Sheathed Mutlicore Industrial Flexible Cable 1 Point 5 Sqmm 3 Corewith Bright Annealed Copper Conductor 1100V As Per Atc , Supply Erecting Steel Tubular Poles In Replacement Pcc Or Rcc Poles Complete With Cast Iron Base Plate Finial Taper Plug Bolt Nut Screw Complete All As Specified Type 410 Sp 31 Of 9M Long As Per Atc , Supply Only In Replacement Hv Bushing 11 Kv For Transfermores Up To Capacity 160 Kva Complete All As Specified And Directed , Supply Only In Replacement V Bushing 0 Point 433 Or 0 Point 415 Kv For Transformer Up To Rating 160 Kva Complete All As Specified And Directed , Supply Only In Replacement Hv Spindle Metal Part Made Out Of Brass With Nuts And Washer Complete For Transformer Of Capacity Upto 160 Kva Complete All As Specified And Directed , Supply Only In Replacement Lv Spindle Metal Part Made Out Of Brass With Nuts And Washers Complete For Transformer Of Capacity Upto 160 Kva Complete All As Specified And Directed , Supply Fill And Top Up New Transformer Oil Low Viscosity Type Of Dielectric Strength 35 To 40 Kv Breaking Voltage Confirming To Is Complete For Indoor Or Outdoor Transformer In Various Sub As Per Atc , S Andf In Replacement Silica Gel Breather Transparent Type With Silica Gel Complete Suitable For Up To 160 Kva Transformer Rating All As Specified , S And F In Replacement Dial Type Thermo Meter Of Minimum 10Mm Dia With Maximum Temperature Indicator For Transformer Of Capacity Up To 160 Kva All As Specified And Directed , Supply Only In Replacement Tap Changer Switch Complete With Handle For Transformer Of Capacity Upto 160 Kva , Supply Only In Replacement Fixed Contact Block Of Vcb 630 S 11 Kv Incl Taking Down Old Material , Supply Only In Replacement Support Insulator 75Mm Dia Of Vcb 630 S 11 Kv , Supply Only In Replacement Auxiliary Switch 6No Plus 6Nc Of Vcb 630 S 11 Kv , Supply Only In Replacement Solenoid Closing Coil 3 Or 110 V Dc Suitable For Type V 207G Vcb 630 A Vmx Breaker , Supply Fix And Connect In Replacement Announciator Suitable For 11 Kv Indoor Control Panel With Necessary Writing And Testing On Completion Complete All As Specified And Directed , Supply Only In Replacement Charging Motor For High Tension 11 Kv Vcb Panels 400 S Operated On 230 Volts Ac Or 30 Volts Dc As Per S Le Complete All As Specified And Directed By Eic , Supply Only In Replacement Upper Spout Ht 11 Kv Vcb As Per S Le And Fixing On Panel All As Required At Site Complete All As Specified And Directed , Supply Only In Replacement Male Contact Made Of Tinned Copper Vcb 11 Kv Made Of Brass As Per S Le And Fixing Testing All As Required And Directed At Site Complete All As Specified And Directed , S And F In Replacement Resin Or Epoxy Coated Air Cooled High Tension Current Transformer Of Dual Ratio Of 200 To 100 Or 5 S 10Va Burden Out Put Accuracy Clas 0 Point 5 Suitable For Rated As Per Atc , S And F In Replacement Over Current Earth Fault Relay Having Auxiliary Voltage 24 To 110 Volts Plus 15 Percent Ac Or Dc Complete All As Specified And Directed , S And F In Replacement Panel Lighting L With Holder With On Or Off Toggle Switch Complete All As Specified And Directed , S And F In Replacement Bakelite Hrc Fuses In Control Or Vcb Panels Complete All As Specified And Directed , S And F In Replacement Breaker Control Switch Suitable For 11 Kv Control Panel And Outdoor Vcbs Complete All As Specified And Directed Incl Taking Down Old Complete All As Specified And Directed , S And F In Replacement Digital Multifunctional Meter As Per Existing Or As Approved By The Ge Complete All As Specified And Directed , S And F In Replacement Selector Switch For Various Type Of Control Panels As Per Existing Complete All As Specified And Directed , S And F In Replacement Switch Air Break Gang Operated God Switch Outdoor Type Ht 11 Kv Triple Poles 200 S With Fixed Contacts Of Phosphorus Bronze And Moving Contacts Of Copper As Per Atc , S And F In Replacement Mild Steel Cross Arms Bracing Supports Cl S And Back Plates Fabricated From Structural Steel Section Incl Nuts Bolts Washers Bending Cold Or Hot Drilling Holes As Per Atc , Excavation In Trenches N Exc 1 Point 5M In Depth And Not Exc 1 Point 5M Wide For Laying Of Ug Cable Or Pole Etc And Getting Out Incl Forming Bottom Surface To Required Level And Gradient As Per Atc , Returning Filling In Excavated Soil Incl Spreading Leveling Watering And Well Ramming In Layers Not Exc 25Cm Thick Complete All As Specified , Removing Excavated Material Or Soil To A Distance N Exc 50M And Where Directed At A Level N Exc 1 Point 5 Above The Starting Point Complete All As Specified And As Directed By Engr In Charge , M And L For Sand Cushioning Dry In Trenches Or Ducts For Protection Of Ug Cables Below Above And Around The Ug Cable Laid In Trenches Of 23 Cm Spread Thickness As Per Atc , Plain Cement Concrete 1 Is To 4 Is To 8 Type D 2Using 40Mm Graded Stone Aggregate As In Foundation Of Poles Etc All As Specified , Plain Cement Concrete 1 Is To 2 Is To 4 Type B 1 Using 20Mm Graded Stone Aggregate For Pole Coping Etc All As Specified , Plain Cement Concrete 1 Is To 3 Is To 6 Type C 2 Using 40Mm Graded Stone Aggregate As In Foundation Of Pole Etc All As Specified , M And L In Replacement For Earthing Complete With Galvanized Steel Plate Electrode 60Cm X 60Cm X 6Mm Thick Buried Directly In Ground Earth Pit Not Less Than 2 Point 25 Meters Deep As Per Atc , Transporting Faulty Or Defective Transformer Rating Upto 160 Kva Ratio 11 Kv 0 Point 433 Or 0 Point 415 Kv To Contractor Workshop From Ramgarh Premises As Per Atc , M And L For Centrifusing Filteratin Or Dehydration Of Transformer Oil Incl Filter Action Using Automatic Centrifusing Machine Incl Armging Elect Supply For Operation Of Machine To Achieve As Per Atc , M And L For Painting Of Distribution Transformer Of Capacity Upto 63 Kva To 160 Kva With Two Coats Of Smoke Synthetic Enamel Paint Colour Or Shed Decided By Ge Externally After Necessary As Per Atc , Repair Or Overhauling To 11Kv Ht Control Panels Complete In And Incl The Following Repair Works As Per Atc , M And L Cable Route Indicator Duly Engraved With Lt Cable 1100V On Cast Iron Round Plate 150Mm Dia With Provision Of 500 Mm Long Min Single Leg Or Stand Of Flat Iron 50 X 6Mm Welded As Per Atc
Basic Detail
Tender No GEM/2026/B/7969666
Bidding Type Tender
Location
City Jaisalmer
State Rajasthan
Key Dates
Publish Date 03 Sep 2026
Submission Date 14 Sep 2026
Open Date 15 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 1.40 Lakhs
Exemption Available
Document List
aeda8f8a-e947-4a5a-a2d4-b1f06d0d4bb5.pdf
9815979_Boq_1.xlsx
general_condition_2026-08-27-21-12-56_24c37ef55981c4c5bd0da5412ffe8048.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 14, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Sep 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
pdf

aeda8f8a-e947-4a5a-a2d4-b1f06d0d4bb5.pdf

xlsx

9815979_Boq_1.xlsx

pdf

general_condition_2026-08-27-21-12-56_24c37ef55981c4c5bd0da5412ffe8048.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail