Tender For Construction Of 8 Nos. E-Type Staff Quarter (S+2) Of New Court Building At Laxmannath, Jaleswar In The District Of Baleshwar For The Year 2026-27.
Tender Value
3.50 Crore
Estimated cost
Bid Submission
17 Sep 2026
10 days left
EMD
3.50 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Baleshwar → Odisha
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of 8 Nos. E-Type Staff Quarter (S+2) Of New Court Building At Laxmannath, Jaleswar In The District Of Baleshwar For The Year 2026-27.
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL PORTION OF THE WORK:- Earth work in ordinary soil in excavation of foundation trenches within 50 meter initial lead and 1.5mt. Intial lift including rough dressing and levelling the bed including all labour, T&P etc. complete as directed by the Engineer in Charge. |
| 2 | Filling in foundation trenches and plinth, with with sand in layers including watering and ramming with cost conveyance, royalities, taxes of all materials and labour with T&P required for the work etc. complete |
| 3 | 300mm dia 7.0 mtr long. Bored cast-in- situ compaction pile Double Under ream Pile foundation with RCC M25 using 12mm size black hard granite chips including cost of boring but excluding the cost of MS/Tor steel and labour charges for cutting, bending, binding of steel. |
| 4 | Dismantling of Prestressed / Reinforced cement concrete grade M-20 & above including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 metres |
| 5 | Carriage of Dismentaling materials from work site to out side with in 5 km lead and lift including all labour as per direction of the Engineer-in-charge |
| 6 | Supplying, filling in foundation & plinth with sand in layers including watering and ramming with cost conveyance, royalities, taxes of all materials and labour with T&P required for the work etc. complete |
| 7 | Providing & applying Post constrution of Antitermite treatment by drilling 12 mm dia holes at a distance of 30cm@ junction of wall and floor about 300mm apart deep enough to each the soil below and chemical emulsion(PREMISE,IMIDACHLOPRIED 30.5SC OF BAYER MAKE mixed with475 ltr water) pumped these holes to soak the soil @1Ltr solution of each holea as per manufactures specification and the holes should be pluged with filling materials including cost of all materials,labour charges,conveyance and all taxes and hiring charges of machinaries as per direction of Engineer in charges. |
| 8 | Cement concrete of proportion (1:3:6) in foundation and floors using 4cm size black broken granite stone aggregates of approved quality and from approved quarry including hoisting, lowering and laying concrete in layers not exceeding 15cm(6\\") thick to the required level ramming, watering, curing etc. complete including cost and conveyance royality taxes of all materials and labour with T&P required for the work etc. complete i as per direction of the Engineer-in-charge. |
| 9 | :Cement concrete (1:2:4) with 12mm hard granite chips(Crusher broken) per 1 cum. |
| 10 | Ground floor |
| 11 | First floor |
| 12 | Second Floor |
| 13 | Terrace floor |
| 14 | First class Fly ash Brick masonry using bricks of size 23cm. x 11 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Foundation & Plinth including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
| 15 | First class Fly ash Brick masonry using bricks of size 25 cm. x 12 cm. x 8 cm. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:6) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
| 16 | Ground floor |
| 17 | First floor |
| 18 | Second Floor |
| 19 | Terrace floor |
| 20 | First class Fly ash Brick masonry using bricks of size 25 cm. x 12 cm. x 8 cm.. having crushing strength not less than 75 kg. Per. Sqr. Cm. in cement mortar of mix( 1:4) with ordinary Portland slag cement(PSC) and screened & washed sand for mortar after immersing the bricks for 6 (Six) hours in water before use in Super stracture including splays cutting, circular moulding, corbelling, chamfering and similar such type of works, watering and curing etc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, scaffolding, sundries, T&P required for the works etc. complete in all respect as directed by the Engineer-In-Charge. |
| 21 | First floor |
| 22 | Second Floor |
| 23 | R.C.C. work of M-25 in following works using 12 mm. to 20 mm. (½” to ¾”) size (20 mm. not to exceed 25%) hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per the direction of the Engineer-in-charge. |
| 24 | Pile cap |
| 25 | Grade Beam |
| 26 | Column |
| 27 | Ground floor |
| 28 | First floor |
| 29 | Second Floor |
| 30 | Terrace floor |
| 31 | Lintel |
| 32 | Ground floor |
| 33 | First floor |
| 34 | Second Floor |
| 35 | Terrace floor |
| 36 | Chajja |
| 37 | Ground floor |
| 38 | First floor |
| 39 | Second Floor |
| 40 | Terrace floor |
| 41 | Roof Beam |
| 42 | Ground floor |
| 43 | First floor |
| 44 | Second Floor |
| 45 | Terrace floor |
| 46 | Roof Slab |
| 47 | Ground floor |
| 48 | First floor |
| 49 | Second Floor |
| 50 | Terrace floor |
| 51 | Stair case |
| 52 | Ground floor |
| 53 | First floor |
| 54 | Second Floor |
| 55 | Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / Tiscon / RINL / JINDAL STEEL / SHYAM STEEL (grade Fe-500D) etc. including bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes of M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge. |
| 56 | Ground floor |
| 57 | First floor |
| 58 | Second Floor |
| 59 | Terrace floor |
| 60 | 12mm thick Cement plaster (1:4) over brickwork with neat Cement punning for skirting including curing etc. complete. |
| 61 | Ground floor |
| 62 | Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 63 | Ground floor |
| 64 | First floor |
| 65 | Second Floor |
| 66 | Terrace floor |
| 67 | Providing 16 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge. |
| 68 | Ground floor |
| 69 | First floor |
| 70 | Second Floor |
| 71 | Terrace floor |
| 72 | Providing 6 mm thick cement plaster to the RCC surface in ceilings in cement mortar (1:4) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge. |
| 73 | Ground floor |
| 74 | First floor |
| 75 | Second Floor |
| 76 | Terrace floor |
| 77 | Providing & laying granite stone flooring using 20 mm thick granite stone slab of approved quality, colour and size between 0.4 Sqm. to 1.0 Sqm. & above in Stair Treads and Risers over an under layer of 20 mm thick cement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443/1972 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shade, with polishing and rubbing ,forming and nosing,moulding edge including cost of all labour, materials, ,, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge |
| 78 | Ground floor |
| 79 | First floor |
| 80 | Second Floor |
| 81 | Terrace floor |
| 82 | Supplying fitting and fixing of Chequerred tiles in floors in cement mortar (1:4) including cost of all labour, materials, ,, royalties, loading and unloading, conveyance, sundries, watering and curing, etc. complete as per the direction of the Engineer-in-Charge |
| 83 | Ground floor |
| 84 | Supplying, fitting and fixing vitrified tile in floor of size 600 mm x 600 mm of approved make conforming to IS:13755 laid on 20 mm thick cement mortar (1:4) (1 cement : 4 coarse sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-in-charge. |
| 85 | First floor |
| 86 | Second Floor |
| 87 | Providing & Fixing Vitrified Tiles in Dados skirting and risers of steps on 12 mm thick cement plaster (1:3) Jointed with Neat cement slurry mixed with pigments to match the shade of the tiles including rubbing and polishing complete as per the direction of Engineer-In-Charge. |
| 88 | First floor |
| 89 | Second Floor |
| 90 | Fixing of ceramic wall tiles in dados, skirting riser of stepps 20cmx30cm / 20cmx20cm special plane / printed series of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 on12 mm thick bed of Cement mortar 1:3 ( 1 Cement :3 sand ) jointed with neat Cement slury mixed with pigment to match the shades of the tiles including rubbing and polishing complete excluding cost of tiles or stones. |
| 91 | First floor |
| 92 | Second Floor |
| 93 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 94 | Ground floor |
| 95 | Supplying, fitting & fixing of well dressed and seasoned sal wood choukath of approved size wrought and put up in door frame including two coat of coaltaring to wall and lintel side faces, in all floors including cost, conveyance, taxes of all materials, cost of all labour, labour cess, T&P etc. complete as directed by Engineer-In-Charge. |
| 96 | First floor |
| 97 | Second Floor |
| 98 | Supplying and fixing W.I. clamps 33cm to 38cm long of 35mm x 5mm size for doors and windows and ventilators including fixing in cement concrete (1:3:6) with 12 mm. to 20mm hard stone chips or in cement mortar (1:3) including cost of all materials. |
| 99 | First floor |
| 100 | Second Floor |
| 101 | Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design including cost of all door fittings and fixtures etc. complete |
| 102 | First floor |
| 103 | Second Floor |
| 104 | Providing and fixing of Fixed Glazing with part Top hung of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6 mm thick “D” quality, galvanized as per IS-277 with zinc of 120 Gm/Sq.mtr) with paint specification being with primer of 5-7 microns and finished paint with polyster paint (Black /Pearl white/ Chocolate Brown) of 12-16 microns alongwith the alkyd backer at the back of 5-7 microns and the sizes of outer frame being of 46x52 mm and with all vertical and horizontal mullions are of 46x70 mm and fixed beadings are of 18x25 mm. Top hung shutter should be of 46 x 46 mm. Accessories / gaskets are to be used as per the manufacturer’s supply and specification like handle being made of high grade aluminium powder coated and with nylon receiver and gasket will be made of EPDM. All corner brackets are to be made of CRCA with zinc phosphating. The mullion caps and louvere d-clips should be of glass filled nylon. The sections are to be cut to length ,mitre joined with corner bracket and frames are fixed to the concrete/masonry walls by means of self expanding screws and glass to be used of 5 mm reflective with all taxes complete. |
| 105 | Ground floor |
| 106 | First floor |
| 107 | Second Floor |
| 108 | Terrace floor |
| 109 | Supplying, fitting and fixing of two track UPVC sliding window of approved make with 6mm thick glass of approved quality complete with frame, shutters and all fitting and fixtures. |
| 110 | Ground floor |
| 111 | First floor |
| 112 | Second Floor |
| 113 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. including cost of all materials with ,, transportation, all labour, sundries, T&P etc. complete as per direction of Engineer in charge. |
| 114 | Ground floor |
| 115 | First floor |
| 116 | Second Floor |
| 117 | Terrace floor |
| 118 | Supplying & fixing G.I Door with G.I pipe made out of G.I sheet including the cost of materials , labour etc all complete as per the direction Engineer-in-Charge. |
| 119 | Terrace Floor |
| 120 | Painting two coats over iron work with approved Enamel paint over a coat of primming, including cost and conveyance of all materials to site, and all labour charges complete as per direction of E.I.C. |
| 121 | Ground floor |
| 122 | First floor |
| 123 | Second Floor |
| 124 | Terrace floor |
| 125 | Painting two coats over wood work with approved Enamel paint over a coat of primming, including cost and conveyance of all materials to site, and all labour charges complete as per direction of E.I.C. |
| 126 | First floor |
| 127 | Second Floor |
| 128 | Finishing wall surfaces with Acrylic wall putty (Water based) of approved make and finished smooth and even surfaces to receive painting including cost of all materials taxes, labour T&P etc. |
| 129 | Ground floor |
| 130 | First floor |
| 131 | Second Floor |
| 132 | Terrace floor |
| 133 | Wall painting two coats with 100% Acrylic emulsion paint (1st quality) weather seal coat exterior grade of approved make & shade manufactured by reputed manufacturer like NEROLAC / ASIAN / BERGER / DULOX or equivalent to make an even finished surface over a coat of primer with water bond cement primer in all heights with all scaffolding and staging charges including cost, conveyance, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete. |
| 134 | Ground floor |
| 135 | First floor |
| 136 | Second Floor |
| 137 | Terrace floor |
| 138 | Wall painting 2-coats with plastic emulsion paint of approved shade on new work 1coats to give an even shade excluding cost of paint. |
| 139 | Ground floor |
| 140 | First floor |
| 141 | Second Floor |
| 142 | Terrace floor |
| 143 | Supplying fitting and fixing of stainless steel of 304 grade in hand railing using 50mm dia. Of 2mm thick circular pipe with balustrade of size 32mmx32mmx2mm @ 0.90mtr C/C and stainless square pipe of size 32mmx32mmx2mm in 3 rows in staircase as per approved design and specification etc all completed. |
| 144 | Ground floor |
| 145 | First floor |
| 146 | Second Floor |
| 147 | 2.5 cm thick grading concrete (1:2:2) on Roof slab with 6 mm size hard broken granite chips on new works |
| 148 | Terrace floor |
| 149 | Dismantling Precasted / Reinforcement cement concrete of grade M-20 and above including T&P and scaffolding wherever necessary, sorting the dismantled materials disposal of unserviceable materials and stacking the serviceable materials with all lifts and lead of 1000m etc.complete as per Clause -202 of MoRT&H Specifications for Road & Bridge works (5th Revision). |
| 150 | Dismantling cement concrete of M-10 and bellow including T&P and scaffolding wherever necessary, sorting the dismantled materials disposal of unserviceable materials and stacking the serviceable materials with all lifts and lead of 1000m etc.complete as per Clause -202 of MoRT&H Specifications for Road & Bridge works (5th Revision). |
| 151 | Dismantling of Granular Courses including stacking the useful materials for reuse and removing the debris within 50mt lead including all labour,machineries, scaffoldings, T&P, Sundries complete as per specification and direction of Engineer-in-Charge. |
| 152 | Carriage of Dismentaling materials from work site to out side with in 8 km lead and lift including all labour as per direction of the Engineer-in-charge. |
| 153 | PH PORTION OF THE WORK:- Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipes confirming to C-PVC / ASTM-D- 1785/89 (Sch-80) and pipe fittings of the following nominal borewith clamps including making good the wall , ceiling and floor, testing all complete as per specification and direction of the Engineer in charge. First Floor |
| 154 | 20 mm dia C-PVC Pipe |
| 155 | 25 mm dia C-PVC Pipe |
| 156 | 32 mm dia C-PVC Pipe |
| 157 | Second Floor |
| 158 | 20 mm dia C-PVC Pipe |
| 159 | 25 mm dia C-PVC Pipe |
| 160 | 32 mm dia C-PVC Pipe |
| 161 | 40 mm dia PVC(Sch-80) Pipe |
| 162 | Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar ( 1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge. In First Floor - 250mm thick wall |
| 163 | Second Floor - 250mm thick wall |
| 164 | Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge.First Floor |
| 165 | Second Floor |
| 166 | Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per the direction of the Engineer in charge. In First Floor |
| 167 | Second Floor - |
| 168 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all complete as per PH specification and direction of the Engineer in charge |
| 169 | Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge |
| 170 | Supplying all materials,labour,T&P and fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 1st class Fly ash brickwork in cement mortar (1:6) of 0.46m height in staging and in circular protection wall to support the tank, 12mm thick cement plaster (1:6) over brickwork, R.C.C slab of size 1.60mx1.60m and 0.10m thick, R.C.C beam of 0.25mx0.30m and 2.60m average length in cement concrete(1:2:4) using 12mm size h.g chips including centering and shuttering, watering, curing, conveyance of all materials to worksite etc all complete as per specification and direction of the Engineer in charge. Fixing 1000 Ltr Roto-moulded water storage tank (Syntax Make) 3 layer on the roof of Second Floor |
| 171 | Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials complete as per specification and direction of the Engineer in charge. (Fixtures make of Brass / G.M / C.P fittings are to be pre-approved by the E.I.C) . |
| 172 | 15mm dia CP Long body bib cock (Jaguar-ARI-CHR-39021) |
| 173 | 15mm dia CP angle stop cock (Jaguar-KKUP-CHR-35053PM |
| 174 | 20mm dia CP Concealed stop cock (Jaguar-FLR-MCH-5089N) |
| 175 | 15mm dia CP two Way bib cock (Jaguar-FUS-CHR-29041) |
| 176 | 15mm dia Jaguar (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible CP Tube & Wall Hook ALD CHR -573 |
| 177 | 25mm dia brass fullway valve(Shakti Make) IS:778 - 1984 class-I |
| 178 | 32mm dia brass fullway valve(Shakti Make) IS:778 - 1984 class-I |
| 179 | 40mm dia brass fullway valve(Shakti Make) IS:778 - 1984 class-I |
| 180 | 15mm dia Extension Piece |
| 181 | 15mm dia CP Flange |
| 182 | 125mm dia. CP grating |
| 183 | 15mm dia C.P Pillar cock(CON-CHR-021KN) |
| 184 | 32mm dia PVC waste pipe with brass coupling nut |
| 185 | Sink cock -jaguar cat no. FLR-CHR-5347N |
| 186 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method /as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. |
| 187 | 110mm diameter U-PVC SWR pipes (Asirvad / Supreme Make) |
| 188 | 75mm diameter U-PVC SWR pipes (Asirvad / Supreme Make) |
| 189 | 110mm dia U-PVC plain Bend |
| 190 | 110mm dia U-PVC Door bend |
| 191 | 110mm dia U-PVC Door Tee |
| 192 | 110mm dia U-PVC Door cross Tee |
| 193 | 110mm dia U-PVC plain Tee |
| 194 | 110mm dia socket plain |
| 195 | 75mm dia socket plain |
| 196 | 110mm dia plain shoe bend |
| 197 | 75mm dia plain shoe bend |
| 198 | 110mm dia U-PVC Offset without ear |
| 199 | 110mm dia U-PVC Cowl |
| 200 | 110mm dia P-trap |
| 201 | Supplying all materials, labour, T&P and fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification and direction of the Engineer in charge.European water closet with ‘S’ trap plain (Parryware/Hind ware/Cera) |
| 202 | supplying all materials, labour, T&P and fitting and fixing 10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 litres capacity PVC LL cistern (Slimline-Deluxe-white-Parryware make) |
| 203 | Supplying all materials ,labour ,T&P and fixing Wash basin with hole for pillar taps with cast iron or MS brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc. fixing pedestral for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin , fixing 12mm dia CP brass waste etc.all complete as per specification and direction of Engineer-in-charge.550mmx440 mm size wash hand basin With porcelain pedestal (Parryware/Hindware/Cera |
| 204 | Supplying all materials ,labour ,T&P and fixing wash kitchen sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste , fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc. including cutting holes in walls and making good the damages etc.all complete as per specification and direction of Engineer-in-charge.600x450x250 mm stainless steel kitchen sink with drain board-glossy-IS:13983 - 1994 (Jayna make) |
| 205 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5m thick on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer in charge.600mmx450mm size B.E mirror (swivelled type) |
| 206 | Supplying all materials ,labour ,T&P and fitting and fixing CP shower with 15mm or 20mm inlet including polishing etc.all complete as per specification and direction of Engineer-in-charge.15mm dia CP revolving shower with arm (Plaza/Aquatic/Cera/ Hindware |
| 207 | Supplying all materials,labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge.CP Towel ring(Plaza/Aquatic/Cera/ Hindware |
| 208 | 25mmx600mm long CP Towel rail(Plaza/Aquatic/Cera/ Hindware |
| 209 | Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge.600mmx125mm plate glass shelf with CP/NP guard rails. |
| 210 | Supplying all materials ,labour ,T&P and fixing CP Soap Holder complete with CP brass brackets fixed to wooden plugs with chromium plated brass screws etc.all complete as per specification and direction of Engineer-in-charge. CP soap holder |
| 211 | CIVIL WORK for PH:- Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. First Floor |
| 212 | Second floor |
| 213 | Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size crusher broken hard black granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.(a) First Floor |
| 214 | Second floor |
| 215 | Providing vitrified tile flooring using Matt vitrified tiles having thickness of 8mm to 10mm conforming to IS 13756 of 600mm x 600mm / 600mm x 300mm Colour & Printed Series (homogeneous) of approved quality of Somany / Kajaria / Asian / Johnson or equivalent in all floors at all height on 25mm thick bed of cement mortar of mix (1:1) laid in proper slope and gradient with screened and washed sharp sand for mortar and grouted with epoxy grout with required quantities of pigments of approved marks to match the shades of the vitrified tile if required watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.Kajaria(600x600mm) First Floor |
| 216 | Second floor |
| 217 | Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge. First Floor |
| 218 | Second floor |
| 219 | Supplying, fitting & fixing of Ceramic wall tiles of premium grade of size 600x300mm having thickness 6.5mm to 6.7mm confirming to IS 13753 in dadoes, skirting and risers of steps laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) jointed with slurry mixed with pigment to match the shades of the tiles etc. complete including cost of all materials, labour T&P etc. required for the work all complete as per direction of the Engineer-in-charge. Kajaria(600x300mm) First Floor |
| 220 | Second floor |
| 221 | Supplying, fitting & fixing of Granite Tiles of minimum upto 0.40 sqm. (10mm thick) of approved make in floors laid on 25 mm thick cement mortar (1:1) (1 cement : 1 course sand) and filling joints with slurry including cost of all materials, labour T&P etc. required for the work all complete incl. rubbing as per direction of the Engineer-in-charge.First Floor |
| 222 | Second floor |
| 223 | Finishing wall surface of walls with Acrylic wall putty (Water based ) of approved make and finished smooth and even surface to receive painting including cost of scaffolding staging charges with cost of all materials taxes, labour T&P etc complete. First Floor |
| 224 | Second floor |
| 225 | Supplying all materials, labour, T&P and providing cement washing 2 coats including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. First Floor |
| 226 | Second floor |
| 227 | Supplying all materials, labour, T&P and distempering two coats to walls with distemper of approved shade on new work to give an even shade etc all complete as per specification and direction of the Engineer in charge. First Floor |
| 228 | Second floor |
| 229 | Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge |
| 230 | 16x (0.91m+2.13m+2.13m) |
| 231 | Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter. |
| 232 | 16x 0.91m x 2.13m |
| 233 | Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, K.B brickwork in c.m (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size C.I grating etc all complete as per approved drawing, specification and direction of the Engineer in charge |
| 234 | Supplying all materials, labour, T&P and constructing inspection chamber of the following size with cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class Fly ash brickwork in cement mortar(1:6),moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:2:4) using 12mm size h.g chips with RCC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge |
| 235 | Inspection chamber Inside size 760mmx760mmx 460mm |
| 236 | Supplying all materials ,labour ,T&P and constructing Man Hole Chamber of inside size 910mmx910mmx910mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , Fly ash brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken black hard granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing, conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-chargeInside size : 910mmx910mmx910mm |
| 237 | Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and 1st class K.B brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge Brick masonry soakway pit 1.40m dia x 2.00m deep |
| 238 | Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge. |
| 239 | 110mm dia u-pvc pipe alround concrete |
| 240 | 50 User RCC Septic tank- 1 NosEarthwork in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing and breaking clods to minimum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer in charge. Initial lift |
| 241 | ……… do ………. with 1st extra lift of 1.50m |
| 242 | Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge. |
| 243 | Supplying all materials, labour, T&P and filling in foundaton and plinth with sand well watered and rammed including conveyeance of all materials to worksite,payment of royalty, taxes etc all complete as per direction of the Engineer in charge. |
| 244 | Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 245 | Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor |
| 246 | Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor |
| 247 | Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. |
| 248 | R.C.C beams, columns, girder and bressmer etc--In G.F |
| 249 | R.C.C floor and roof slabs, landings, balconies, projecting sunshades and chajjas up to 4.30m height |
| 250 | Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in chargeIn ground floor (inside) |
| 251 | Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4)with cement punning and butimen painting including watering,curring and conveyance of all materials to site. |
| 252 | Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site. |
| 253 | Supplying all materials, labour, T&P and futting and fixing 20mm dia MS/CI step iron including supply of necessary C.C(1:2:4) for fixing etc complete as per P.H.D. specification. |
| 254 | Supplying all materials, labour, T&P and fitting and fixing S.W.Tee of size 110mx110mx110m as per P.H.D.specification and direction of the E.I.C. |
| 255 | Supplying all materials, labour, T&P and constructing vent base as per P.H.D specification etc all complete. |
| 256 | Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the engineer in charge. 110mm diameter U-PVC SWR pipes(Supreme/Ashirvad) |
| 257 | 110mm U-PVC cowl |
| 258 | Supplying all materials, labour, T&P for removing the excavated earth by mechanical means etc . |
| 259 | Sinking of 2 Nos.150mm dia tubewell through hand boring (water jet ) method .Supplying all materials, labour, T&P and setting up boring equipments including erection of suitable staging for installation of the required size of tube well, dismantling and removing the same after complection of the work, including transportation of the boring equipments, cleaning and levelling the site, excavation of mud pit, channels etc, levelling of site all complete as per direction of Engineer in charge |
| 260 | Supplying all labour, T&P and transporting the boring pipes, top casing , grouting pipes, P.V.C pipes and fittings, P.V.C well screens, cement, bentonite and gravels etc to the worksite including loading and unloading etc all complete as per direction of Engineer in charge |
| 261 | Supplying all labour, T&P and drilling pilot bore not less than 102mm dia, without casing pipes in all kinds of soils and rocks for the following depths excluding supply of necessary boring pipes including supply of necessary cutting equipments, extra sockets (whenever required) etc and withdrawing the boring pipes, washing and keeping the bore clear for logging if required all complete as per direction of Engineer in charge. Drilling pilot bore from 0 to 360 metres |
| 262 | Supplying all labour, T&P and reaming the pilot bore to the following sizes and depths without casing pipes including withdrawing the boring pipes, washing the bore by means of pipe cylinder etc all complete as per direction of Engineer in charge Reaming 100mm to 150mm dia from 0 to 360 metres |
| 263 | Reaming 150mm to 200mm dia from 0 to 360 metres |
| 264 | Reaming 200mm to 250mm dia from 0 to 360 metres |
| 265 | Supplying all labour, T&P and jointing materials and lowering the 300mm dia top casing pipes into the position and removing the same after use all complete as per direction of Engineer in charge from 0 to 360 metres |
| 266 | Supplying all labour T&P and grouting with cement slurry for saline sealing in the bore around the 150 mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge. |
| 267 | Supplying all labour, T&P and jointing materials and lowering the pvc casing pipes, fittings and well screens in position, including fitting and fixing of centraliser, cutter plug and washing the bore all complete as per direction of Engineer in charge 150mm dia PVC casing pipe from 0 to 360 metres |
| 268 | Cost of 150mm dia PVC ASTM pipe (sch-80) |
| 269 | Cost of 150mm dia strainer cutting |
| 270 | Cost of 150 mm dia C.I. end plug |
| 271 | Cost of bentonite powder |
| 272 | Supplying all materials, labour, T&P and packing the bore with washed gravel of river shingles of required size and specification around the well screen and pipe etc all complete as per the direction of the Engineer in charge |
| 273 | Cost and Conveyance of Gravel |
| 274 | Supplying all materials, labour, T&P and packing the bore with river sand over the gravel pack etc all complete as per the direction of the Engineer in charge |
| 275 | Cost and Conveyance of sand |
| 276 | Supplying all labour T&P and grouting with cement slurry for sanitary sealingin the bore around the upper most 3 metres of 150mm dia PVC casing pipe etc all complete as per the direction of the Engineer in charge. |
| 277 | Cost of Cement |
| 278 | Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per direction of the Engineer in charge By Compressor |
| 279 | Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge2.00 H.P three phase submerssible pump set |
| 280 | DOL Control panel |
| 281 | 40mm dia steel short piece |
| 282 | Well cap |
| 283 | 50mm size CI bracket |
| 284 | 2.50sqmm flat cable |
| 285 | 40mm dia GI pipes |
| 286 | Steel rope with cover |
| 287 | 32mm dia HDPE pipe |
| 288 | Labour charges for lowering including transportation |
| 289 | Supplying all materials, labour, T&P and constructing Bore well protection chamber of the inside size 650x650x1000hight with cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ash brickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4) inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. |
| 290 | EI PORTION OF THE WORK:- Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/Vguard with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type ( flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. |
| 291 | GROUP-A |
| 292 | GROUP-B |
| 293 | GROUP-C |
| 294 | Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 295 | Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 296 | Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type) with suitable size modular box & cover including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 297 | Supply and fixing of ISI marked modular type 2nos 6Amp socket with switch on suitable size of metal box and modular cover in front on surface or recess including all conection as per direction of E.I.C. All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials. (Make :Legrand(Myrius)/-Schneider(Zencelo)/PANASONIC(VISION) |
| 298 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5) |
| 299 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5) |
| 300 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEIV Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5) |
| 301 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.2 nos single core 6 sq. mm copper wire for phase and neutral and 01 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit.(2X6+1X2.5) |
| 302 | Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI/V Guard in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge.4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(4X6+2X4) |
| 303 | Supplying and installation of AC Point having 16-20A DP MCB, C series with enclosure, Schneider/Siemens/Legrand/ABB of suitable size as required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 1 year against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 304 | Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision) as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 305 | S/F of Bakelite angle holder/batten holder (make-Anchor/Havells or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling rose as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. |
| 306 | Sub-Head II (Light fitting Fixture & Fan) |
| 307 | Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years. |
| 308 | Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC copper winding ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix/Bajaj Turbo Pro 12DC5 ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.(With fan Regulator) |
| 309 | Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years |
| 310 | SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories with diffuser having 2 years warranty i/c connection etc as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj). The luminaire should be Replacement Warranty will be 2 years . |
| 311 | SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years |
| 312 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved. |
| 313 | S/F of 5 step type Modular electronic Fan Regulator ISI Marked with all connection complete in all respect as per direction of Engineer in charge ( Make-Schneider(Zencelo)/legrand( Myrius)/Panasonic (vision) |
| 314 | Supplying and fixing 32 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole+E-DP plug & socket DB with 32A DP MCB,C series,10ka as per IEC-61439-3 ,suitable for flush & surface mounting,supplied with neutral link with provission for mounting modular devices as per direction of Engg.-in-Charge. Make-Legrand/ Siemens/Schneider/ABB |
| 315 | BDBS,DB,AC DB,FLOOR PANELS,MCBS |
| 316 | Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB Itus as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years |
| 317 | Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years . |
| 318 | Supply and fixing of 6 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years . |
| 319 | Supplying and fixing 6-32 Amps rating, C series,10KA breaking capacity,SP, 240 volts, MCB . Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 1 years.. |
| 320 | Supplying and fixing 40-63Amps DP 230 volts,10KA C series MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years |
| 321 | Supplying and fixing 32Amps DP 230 volts,10KA C series MCB Make-LEGRAND-DX3 / Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. The MCB should be Replacement Warranty will be 1 years |
| 322 | (Earthing) INSTALLATION:- Supplying,installation,testing & commissioning of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge. |
| 323 | Providing and fixing 25mm x 5 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 324 | Providing and fixing 50mm x 6 mm GI strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge. |
| 325 | CABLING AND END TERMINATION MAIN AREA |
| 326 | Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. |
| 327 | 3.5core x 120 sq mm |
| 328 | 4core x 16 sq mm |
| 329 | 3.5core x 35 sq mm |
| 330 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 331 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge. |
| 332 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 333 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM but not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 334 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in open duct etc as required as per direction of Engg.-in -charge. |
| 335 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size exceeding 25 SQ. MM in open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge. |
| 336 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 337 | Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge. |
| 338 | Supplying and making end termination with double brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge. |
| 339 | 4 core x16sq mm |
| 340 | 3.5 core x35 sq mm |
| 341 | 3.5 core x120 sq mm |
| 342 | Providing,fixing and laying of following dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 343 | 50 mm dia |
| 344 | Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 345 | 200 mm dia |
| 346 | S/I/T&Commissioning of CPRI tested LT indoor floor mounted cubical type electrical main panel (for power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed as G.A drawing. (FOR ALL MAIN CONNECTED LOAD) )as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessories must be 1 years & compelete test certificate must be submitted along with panel board including component list.50x10mm Separate Aluminium Earth bus bar should be installed.All the feeders shall have ON/OFF/TRIP indication. |
| 347 | In commer-1-01 number of 150A 4P Icu=100%Ics,36Ka Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) (FROM TRANSFORMER) |
| 348 | Busbar- 04 numbers of 250 Amps aluminum bus bar duly sleeved by color coded PVC sleeve & supported by suitable size DMC insulator. |
| 349 | Out going- 03 numbers of 63A 4P MCCB,16Ka MCCB with TMR based release with adjustable overload ,Icu=100%Ics( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS/ ABB Formula) |
| 350 | Out going- 8 numbers of 63A DP MCB10kA,C series. Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200 With 8 Nos 1 Phase Energy Meter. |
| 351 | 01 no of 80A 4P onload changeover switch (Make-Siemens/Schneider/Legrand/ABB) |
| 352 | Out going- 3 numbers of 32A 4P MCB10kA,C series. Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200 |
| 353 | Out going- 3 numbers of 40A DP MCB10kA,C series. Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9//ABB SB 200 |
| 354 | Instrument- (i) 06 numbers phase indicating lamp with toggle switch & HRC fuse. |
| 355 | (ii) Digital Meter Displays Current, line to neutral & line to line Voltages, frequency & Power Factor. (VA & PF - Phase Wise & Average) (SECURE/ Legrand /abb/Siemens/Schneider) for all the feeders |
| 356 | (ii) 02 set of 4 pole (3P+N) ( T1+T2 - Iimp 8 kA/pole T2 - 60 kA) 65 KA SPD with 63A, 4P MCB, C series, 10kA (Make : Schneider (ACTI 9 ) /legrand (DX 3)/siemens (Betaguard)/ABB SB 200 for all the incomers |
| 357 | CABLE TRAY /RACE WAY FOR DISTRIBUTION OF POWER |
| 358 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 200mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 359 | Supplying,fixing of perforated cable trays with horizental & vertical bends,reducers ,tees,crossover,brakets & other accessories ar requited confirming to IS-IEC -61537 ,the cable tray shall be galvanised for corrosion protection confirming to DIN EN 10346/ISO 1461. Size 60mm(H) x 300mm(W) of MAKE- Profab/OBO/Neidax.The Load bearing capacity of the Cable Trays should be minimum of 104.8Kg/meter at the span of 1.5Meter as per UL specifications as required as per direction of Engg.-in-Charge. |
| 360 | VTPN DB FOR FLOOR DISTRIBUTION - Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years.FLOOR LIGHT DBFloor LIGHT DB(6Way VTPN DB) Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9 with 100A 4P MCCB (25KA)( Make-LEGRAND-DPX3 / Siemens-3VA Model/ Schneider- CVS) as Incomer, Outgoings-63A TP MCB 10 KA breaking capacity,C series, (Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9) -6Nos.Warranty on DB is 3 years |
| 361 | SUPPLY AND FIXING OF 1no. of cubicle panel for installation of Sub Meter of 2mm thick CRCA panel box of follwing dimensuion:- 1 m x 1 m(30 cm depth)= 1 sqmtr in complete fabrication of metal clad,powder coated,compartmentalised cubicle panel as per CPWD Electrical specification including insulated busbars,supports,interconnections,erection of switchgears and making provisions of incoming/outgoing cables etc.- |
| 362 | EXTERNAL AREA LIGHTING S/F of Street light- 90W,120 lm/w efficacy ,IP PC Lens new generation energy saving & environmental friendly long life versatile pressure die-cast alluminium IP66 roadway luminaire with high power LED as light source with acrylic cover(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) (5Years Warranty) |
| 363 | Supply of 6 mtr long hot dip Galvanized Octagonal pole manufactured from HT steel(single arm) as per BS EN 10025/IS 2062 having minimum yield strength of 350 N/ SQMM having top dia of 70 MM A/F and bottom dia of 130 MM A/F of 3 mm thick or more , base plate as per IS 2062 complete with 4 nos. En 8 grade foundation bolts to withstand basic wind speed of 180 KM/HR wind speed (As per structural calculation of pole manufacturer )or more (Make of poles: Utkarsh/Bajaj/RR Ispat/Vakarangee as per direction of Engg. in Charge. |
| 364 | Installation of pole by making the suitable size foundation by embeding the pole 1 mtr into the ground with necessary civil work and fixing the light on the pole equievalant make ISI marked as approved as per direction of Engg. in Charge. |
| 365 | Supplying, Erection, Fixing, connection & testing of 40W LED GATE Light of (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj) maintenance free having 2 years warranty G.I P ipe with braket including MCB box & including with foundation as per the Drawing for inspection as required & as per direction of Engg.-in-Charge. |
| 366 | S/IT/C of materials and installation of GI earth plate 600mmx600mmx6mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge |
| 367 | Supply and laying of 6SWG GI wire on surface or recess as per the direction of Engineer-in-charge |
| 368 | S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type IP66 based panel made out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed as G.A drawing. (FOR USE) with 63A TPN MCB 01 NO,1 no. Astronomical digital timer, AUTO MANUAL(with start and stop push button) SELECTOR 63 A 3P contactor, OLR,RYB,ON,OFF trip indication, Type-II SPD 40ka ,,04 nos 10A 4P MCB,C,10KA as outgoing MCB legrand dx3/ schneider acti9 A9N/ Siemens betaguard/ ABB ( SB 200) as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 1 years of acceptance of materials |
| 369 | Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Make-Polycab/KEI/RR Kabel/Finolex/Gloster/Havells |
| 370 | Providing,fixing and laying of fallowing dia PN10 HDPE pipe (medium class) in ground complete with fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge. |
| 371 | Supply and fixing of digital time switch for controlling Daily and weekly time switch, Quick and easy programming due to the option to Select Day blocks, day blocks can be individually set or Selection from the Blocks Mon-Sun, Mon-Fri or Sat- Sun Programming with precission to the Second swithch time vidisible in weekly overview on display. Make:- Legrand/LT. |
| 372 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 373 | Supply of Roof conductor holder for parapet- PolyamideConductor holder:With M8 female thread or diameter 7mm, M8Screw to connect the conductor holder.Weather andtemperature resistant from -35 to +90 degree Celsius tested.Conductor holder @ 1 meter distance.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO/Dehn/ABB |
| 374 | Supply of Polyamide roof cable holder for flat roof:DIN 48829 Form B1. Closed form with bottom. Filling weight1Kg (frost-resistant concrete). Sleeve from polyethylene, black@ 1 meter distance. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 375 | Supply of Connector: For T cross and parallel connectors. Quickinstallation using hexagonal bolt M10X30 high-grade hot dipgalvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO/Dehn/ABB |
| 376 | Supply of 1 mtr vertical air terminal with mounting accessorieson the flat surface to meet the requirements of IS/IEC 62305.Tested for Electrical , mechanical and chemical as per IEC62561. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 377 | Supply of Vertical air terminal with accessories:Providing of Air terminalsas per IS-IEC -62305 part-3Nominal size Ø10/16 mm aluminium rod:2 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN48801) Suitable for high wind load.Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 378 | Supply for Providing of Stand for Fang Fix system 16 kg with base andclamp ,made up of frost resistant concrete and clamp testedupto 100KA lightning current . Make-OBO/Dehn/ABB |
| 379 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frostresistant concrete. Make-OBO/Dehn/ABB |
| 380 | Supply of Test Joint (Folding Clamp) suitable to connect 8mmround conductor and max by 30x3 mm GI strip as specified indrawing and directed by Engineer.Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 381 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr HeightFor Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/Dehn/ABB |
| 382 | Supply of Galvanised Steel Flat 30X3 mm thickness from earthelectrode directly in ground as required. Flat conductor HotDipped Galvanized. Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 383 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB |
| 384 | Supply of flat conductor holder- Fit: FL 30, With mounting hole6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece fromhot-dip galvanised steel, Bottom section from polyamide, black.Tested as per IEC 62561. Make-OBO/Dehn/ABB |
| 385 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB |
| 386 | Supply of UL Listed maintenance free ,Low carbon coppercoated earth rod of 3 metre electrode having diameter of 17.2mm with copper coating thickness of 250micron tested as perIEC 62561-2 Make-OBO/Dehn/ABB |
| 387 | Supply of universal clamp made of SS to connect rod with flatconductor Make-OBO/Dehn/ABB |
| 388 | Supply of Earth conductivity enhancing mineral compound shall be of 25kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO/Dehn/ABB |
| 389 | Supply of The above arrangements shall be provided with Heavy dutyearth champer of 5000kg load bearing capacity to ensure thesafety of earthing system Make-OBO/Dehn/ABB |
| 390 | Lightnig counter - To count no of lightning strike & it can record the date and time of the lightning incident also tested as per IEC 62561-6. Make-OBO/Dehn/ABB |
| 391 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 392 | FIRE FIGHTING PUMPS AND APPURTENANCES Supplying, installation, testing and commissioning of Electric Motor Driven Pressurization Terrace Pump having discharge of 450 LPM at 35 Mtr head complete with Pump Set, Electric Motor suitable for operation on 415 V ,3 ph, 50 c/s AC supply , Base Frame.Make-Wilo/KSB/Kirloskar/Grundfoss |
| 393 | Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required comprising of One (1)- 63 Amp, 10 KA,TPN (Class-C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB, Digital Voltmeter with selector switch. DOL starter with O/L and Single Phasing Preventor suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button.as per direction of engineer in charge Control panel for fire pumps for auto action.make-Legrand/schneider/Siemens/eq. Model of ABB/L&T/Hager/C&S/Havells |
| 394 | 1100 V GRADE POWER/CONTROL CABLES :SITC of FRLS,PVC outer sheateh, steel armoured, aluminium, 1100v grade power cables with glands etc. The minimum size of the cables shall as mentioned below as per direction of engineer in charge.Make-Polycab/Havels/KEIRR KABEL/FINOLEX/GLOSTER 3.5C x 16 mmsq |
| 395 | 2 C x 1.5 mmsq |
| 396 | PIPE & VALVES ETC. |
| 397 | Supply,Installation,Testing & Commissioning of 'C' Class heavy duty MS pipe (as per IS 1239 upto 100 mm NB and IS 3589 for above 100 mm 6.33mm thick) with flanges and fitting such as bends, tees, reducers, rubber insertions and galvanized nuts and bolts of following size on surface along wall / shaft with MS bracket, suspended from ceiling/ beam with suspenders duly painted with two coats of primer and finished with enamel paint of approved colour laid through pipe or in trench after wrapping with hassen cloth after applying coal tar primer as required as per direction of Engineer-in- charge.Make-TATA/SAIL/JINDAL |
| 398 | 100mm NB |
| 399 | 80mm NB |
| 400 | 25mm nb |
| 401 | Providing, fixing, testing and commissioning of following size manually operated hand lever type cast iron double flanged slim seal wafer type Butterfly valves with EPDM iron disc as per IS-13095 having pressure ratting PN -1.60 including fixing the same with supply of required jointing materials like rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of E.I.C. Make-Zoloto/AUDCO/Leader |
| 402 | 100mm NB |
| 403 | Providing, fitting & fixing of following size cast iron double flanged type dual plate Non return Valve as per IS- 5312 (Part 1): 2004 with ISI mark of pressure ratting PN-1.60 including fixing the same with supply of required jointing materials like flanges, rubber insertion, MS nuts & bolts, paint etc. and testing the joints with required water pressure etc. all complete as per specification & direction of Engineer-in-charge. Make-Zoloto/AUDCO/Leader |
| 404 | 100mm NB |
| 405 | Supply,Installation,Testing & Commissioning of Pressure gauge of 0-16 Kgf/sq.cm. range with cut-off bronze ball valves of suitable size with all accessories as per direction of Engineer-in-charge.Make-H.Guru/G.Guru |
| 406 | Supply,Installation,Testing & Commissioning of Pressure Switch with cut-off bronze ball valves with integral strainer & flare nut (mixed ends) of suitable size with all accessories as per direction of Engineer-in-charge.Make-Danfoss/Indfoss/Grundfoss |
| 407 | Supply,Installation,Testing & Commissioning of stainless steel strainer fabricated out of 1.6 mm thick stainless steel sheet Y Stainer with 3 mm dia hloes with stainless steel flange as required. Make-Zoloto/AUDCO/Leader |
| 408 | 100mm NB |
| 409 | DOWN COMER SYSTEM |
| 410 | Supply,Installation,Testing & Commissioning of Stainless steel Hydrant Valve / Landing valve, of 63 mm NB size, type-A, single headed , oblique type, as per IS :5290/93 and as per direction of Engineer-in-charge.Make-Newage/Minimax/Fireshield |
| 411 | Supply,Installation,Testing & Commissioning of SS short branch pipe with 63 mm male inlet and 19 mm outlet nozzle, as per IS:903 and as per direction of Engineer-in-charge. Make-Newage/Minimax/Fireshield |
| 412 | Supply,Installation,Testing & Commissioning of 63 mm NB and 15meter long RRL Fire Hose fitted with 63mm intstantaneous stainless steel male & female SS coupling, complete by GI wire binding for Internal Hydrant as per direction of Engineer-in-charge. Make-Newage/Minimax/Fireshield |
| 413 | Providing supply & fixing of MS Hose Box for of suitable size(750X600X250mm) to accomodate 2 nos. of 15/ 1 no of 30 mtr long fire hose and a branch pipe, wall mounted type as per direction of Engineer-in-charge. Make-Newage/Minimax/Fireshield |
| 414 | Supply,Installation,Testing & Commissioning of Swinging pattern wall fixing first aid hose reel made from MS sheet and waterways and moving parts with rubber hose of 20 mm dia. and 30 mtrs. long with ABS(Plastic) shut-off nozzle as per IS: 444/IS: 12585 Type-I., complete with all accessories as per direction of Engineer-in-charge. Make-Newage/Minimax/Fireshield |
| 415 | Providing, fitting and fixing of C.I. 25 MM single air relief valve with stop cock confirming to IS:14845/2000 with ISI mark for water works purpose including fixing the same with hydrant riser including testing & commissioning the system etc. all complete as per approved specification & direction of Engineer-in-charge. |
| 416 | Providing, fitting & fixing of 2-Way GM fire brigade connection consisting of 63 mm dia instantaneous type male couplings with built-in check valves, 150mm dia flanged outlet complete with bolts, nuts and rubber insertions confirming to IS:904 with ISI mark including testing & commissioning the system etc. all complete as per apporoved specification & direction of EIC. Make-Zoloto/Kirloskar |
| 417 | EXTINGUISHER SYSTEM |
| 418 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,Carbon di-oxide type capacity 4.5kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex/Flameklog) |
| 419 | Supply,Installation,Testing and Commisioning of ISI marked (IS:2878) Fire Extinguisher ,ABC type capacity 6kg with all accessories (Ever safe/Fire shield/Ceasefire/Safex/Flameklog) |
| 420 | Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \\"FIRE\\" in black out side and handle with mounting bracket. |
| 421 | SIGNAGES |
| 422 | SIGNAGES:-Providing and installing in position the following type of sign boards made out of 3mm thick flexyle photoluminescent based glow in dark sheeting with luminous properties enclosed in a weather proof Uvstabilized film with UV screen printing by imported links pasted over3 mm thick cast acrylic from front side with 6 mm thick acrylic, -20 to+80 deg C, Suitablefor indoor use, greenish yellow, glow visible upto 4-6 hr in total darkness.Make-Prolite/Bajaj |
| 423 | Illumination Glow light for Exit Indication with Battery Back-up. |
| 424 | MANUAL FIRE DETECTION AND ALARM SYSTEM |
| 425 | Manual Fire AlarmSystem-:Supply, installation, testing and commissioning of Conventional type Main Fire Alarm Control Panel (FACP), the panel shall be conventional type fire detection and alarm system with capacity of 4 zone complete with all accessories and battery back up for 48 hours in standby mode and 15 minutes in alarm condition. The panel shall have minimum of 80 character display complete accessories.Make- System sensor by Honeywell/Ravel/Bosch. |
| 426 | Supplying, installing, testing and commissioning of conventional type Manual call point with all accessories complete. The device Make-System sensor by Honeywell/Ravel/Bosch. |
| 427 | Supplying, installing, testing and commissioning of conventional type Hooter at 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication with all accessories etc., complete. Make-System sensor byHoneywell/Ravel/Bosch.. |
| 428 | Supplying, installing, testing and commissioning of 2C x 1.5 sq. mm, Twisted Pair PVC insulated FRLS unarmored Cable with Accessories confirming to IS standards and specifications. The quoted rate shall includes of Acrylic Fire stop Sealant in the opening for cables passing through fire compartment walls of RCC floors, masonry walls to provide up to 2 hours fire rating. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 03, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 10 daysSep 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender