Tender For Special Repair To Drain And Boundary Wall At Salaria Enclave,Dwaraka Under Ge (West) Delhi Cantt -10
Tender Value
1.15 Crore
Estimated cost
Bid Submission
01 Oct 2026
2 days left
EMD
1.90 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repair To Drain And Boundary Wall At Salaria Enclave,Dwaraka Under Ge (West) Delhi Cantt -10
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-Sep-2026 | corrigendum | Other | 01-Oct-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : HQ CWE NO 2 DELHI CANTT-10 NAME OF WORK: SPECIAL REPAIR TO DRAIN AND BOUNDARY WALL AT SALARIA ENCLAVE,DWARAKA UNDER GE (WEST) DELHI CANTT -10 Contract No : CWE/WEST/TOKEN-35/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Notes: 1. Before commencing any excavation work, the Contractor shall intimate the IGL authorities and obtain necessary clearance/instructions from the authorised IGL representative regarding the location of underground gas pipelines and other utilities. Excavation shall be carried out strictly in accordance with the directions issued by the IGL authorities.2. All unserviceable materials, debris, waste, excavated earth, vegetation, and other spoil generated during the execution of the work shall be removed and disposed of outside Defence land in accordance with the prevailing local Municipal regulations and environmental guidelines, as amended from time to time, at no extra cost to the Government. |
| 3 | Excavation in trenches n. exceeding 1.5m wide and n. Exc 1.5 mtr in depth, for foundation etc, or for shafts, wells, cesspits, manholes, pier holes, etc not exc 10 Sqm on plan and not exc 1.5 m in depth and getting out in soft/loose soil, complete all as specified and directed. |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m in any type of soil, complete all as specified and directed. |
| 5 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m in any type of soil, complete all as specified and directed. |
| 6 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 1.5 m n. exc. 3.0 m in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 3.0 m in any type of soil, complete all as specified and directed. |
| 7 | M&L for plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates, in foundation filling and mass concrete, complete all as specified and directed. |
| 8 | M&L for brick work with subclass 'B' bricks, straight or curved on plan to any radius in walls with old size bricks, built in cement mortar 1:4, complete all as specified and directed. |
| 9 | M&L for PCC 1:2:4 , type B-0 using 12.50 mm graded crushed stone aggregate as in coping, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 10 | M&L for Cleaning of existing open/ covered drains including culverts of any width and any depth including removal and refixing of existing good quality drain covers, removal of loose soil, cement, mud, garbage, debris, sludge (liquid/Dry), vegetation, tree roots etc. in around drain for a meter on either side complete in any position manually or mechanically outside MOD land and dumping the same according to local Municipal guidelines complete all as specified and directed. |
| 11 | Demolition of Brickwork or stone/ boulder masonry, built in lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc. complete all as specified and directed. |
| 12 | M&L for plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates, as in surface channels and drains, complete all as specified and directed. |
| 13 | M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc., complete all as specified and directed. |
| 14 | M&L for Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc., complete all as specified and directed. |
| 15 | S&F Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles n exc 5 kg each, at drain openings in drains complete all as specified and directed. |
| 16 | S&F mild steel work as in posts & struts in fencing over existing wall including cutting tops to shape as directed, drilling holes, notching for wire etc, including all necessary drilling, bolting or welding and similar works conforming to Grade E-165 (Fe 290), complete all as specified and directed.Note: The rate quoted in this item also includes for PCC 1:2:4, type B-0 (using 12.50 mm graded crushed stone aggregate) coping, for fixing of MS section on existing wall as required to match the existing coping on the wall. |
| 17 | M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed. |
| 18 | M&L Preparing surfaces of steel and iron work, new or old, of any description and girth, not otherwise described, and treating small articles such as stop, covers, gully, gratings, holdfasts, ends of posts, backs of chowkats, etc., area n exc 0.1 sq. m each with tar or coal tar black paint complete all as specified and directed. |
| 19 | S&F galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and directed.Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment. |
| 20 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25cm in soft/loose soil complete all as specified and as directed. |
| 21 | Removing of excavated material n.exc 50mtr and depositing where directed at a level n.exc 1.5mtr above the starting point complete all as specified and directed. |
| 22 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 23 | S&F razor blade barbed concertina coil having minimum weight of 15.2 kgs (+) or (-) 5 % per coil stretched to a length of 10 to 12 mts to achieve 600mm dia as in fencing to steel posts and to another coil/MS nibs all as shown on drawings including fixing with special galvanized fastners such as clips,c clips,U clipscomplete all as specified and directed.Note:- Linear length of wall on which coil is fixed after stretching shall be measured for purpose of payment.) |
| 24 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 25 | Taking down cement or cement lime plaster, any description on brick, block, RCC or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc., complete all as specified and directed.Note:- Taking down should be carrying out carefully to avoid damage to the plaster on opposite face of the wall and if damaged, contractor should carry out the necessary repair work on its own cost. |
| 26 | M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings ,complete all as specified and directed.Note:- (Payment for providing grooves shall be made separately). |
| 27 | M&L for Forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using aluminium battens, nailed to the under layer including embedding of aluminium battens, repair to the edges of panels and finishing the groove complete all as specified and directed. |
| 28 | Material and labour for medium duty precast drain cover slab 80 mm thick of RCC 1:1.5:3 type A-1 (20 mm dia crushed stone aggregates) using 10mm dia TMT bars, including flat iron 150mmx6mm all around the slab, complete all as specified and directed. |
| 29 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed. |
| 30 | M&L for laying and testing of Reinforced concrete drain pipes, class NP2, having bore of pipe 200 mm, laid and jointed complete with collars, complete all as specified and directed. |
| 31 | M&L for Concrete bed in cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) to drain pipes having bore of pipe 200 mm, including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified and directed. |
| 32 | M&L for laying and testing of Suction PVC Flexible pipe, having bore of pipe 100 mm, laid and jointed complete with Submersible Pump, including cutting hole in wall (wherever required), etc, complete all as specified and directed. |
| 33 | M&L for Concrete bed in cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregates) to drain pipes having bore of pipe 100 mm, including packing under and completely surrounding pipes with concrete after they are laid and tested;complete all as specified and directed. |
| 34 | Material and labour for Loose filling of Broken stone or boulders/ aggregates of gauge 80 to 150 mm as in rainwater harvesting pits, soakage pits, etc. complete all as specified and directed. |
| 35 | Material and labour for Loose filling of Broken stone or boulders/ aggregates of gauge 40 to 80 mm as in rainwater harvesting pits, soakage pits, etc. complete all as specified and directed. |
| 36 | Material and labour for filling of Moorum/ red bajri filling as in rainwater harvesting pits, soakage pits, etc., laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering ,complete all as specified and directed. |
| 37 | Provn of S&F 5 HP three phase non-clog Submersible sewage pump with motor of delivery size 100 mm dia, headd 12mm & discharge 2100LPM and speed 1450 RPM with CI impeller , SS shaft with 10m cable and susction pipe , double mechanical seal (ceramaic/carbon) IP68 protection connecting to the existing pipe lines electrically and mechanically , making proper alignment , testing and commissioning to the entire satisfaction, complete all as specified and directed. |
| 38 | Provn of S&F fully automatic star delta starter suitable for motor of capacity 5 HP including contactors and wiring with suitable size of copper wire complet all as specified and directed. |
| 39 | Provn of S&F Submersible copper cable 3 core 6 sqmm including connectors complete all as specified and directed. |
| 40 | M & L cement concrete M-30 design mix (using 20mm graded aggregate) for foundations, including rafts, footings, foundations beams, plinth beams, bases for columns etc complete all as specified and directed. |
| 41 | M & L cement concrete M-30 desig2 mix (using 20mm graded aggregate) for columns, pillars, piers, post and strut all as specified. |
| 42 | M & L for formwork to sides of concrete , foundations, footings, bases of columns, rafts and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work for rough finished surface all as specified. |
| 43 | M & L for formwork to sides of pillars, posts, struts, piers, columns and stanchions etc.for fair finished surface all as specified. |
| 44 | M&L for mild steel TMT bars 10mm dia and over cut to length,bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified |
| 45 | - ditto- as ser item above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed |
| 46 | M & L for removing excavated material exc. 250m but not exceeding 500m and depositing where directed all as specified. |
| 47 | S&F Plate (plain or chequered) channel or square cut or notched (ordinary and counter sunk) forming holes, without any attachment |
| 48 | S&F mild steel screw bolts (machine made) with hexagonal or square heads at one and screwed both ands, each screwed and to be fitted with washers and one hexagonal or square but length of bolt exc 30cm long of dia 20 mm. |
| 49 | S&F Fe 410W grade E250 quality 4 Framed work as in doors or gates of angle or other section with gusset plates, rails, braces,heavy duty hinges,roller etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (inclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete incl Add to any of the foregoing items if structural steel is painted one shop coat of zinc chromate primer paint (including preparation of surface) at Contractor's workshop before fabrication complete all as specified and directed. |
| 50 | Providing and Fixing \\"SALARIA OFFICERS ENCLAVE\\" logo ,600X600 in Brass sheet of thickness 2mm with logo engraved over it, matching to colour design fonts as drawings as approved by GE, screwed /welded to gate at loaction as specified and directed. |
| 51 | S&F coloured Mettallic classic series 4mm thick FR, coil thickness-0.5 mm (Top & Bottom), Alloy-H-8 1100, Core thickness-3mm (70% inorganic core & 30% virgin core), Coating-PVDF (KYNAR 500) upto 28 microns(+ 2) ACP sheet including over framework as reqquired and incl necessary cleats and secured with screws as approved by Engineer in charge complete. (The posn of work at height of 16.5 mtr from FFL, hence necessary arrangements for approaching and fixing requried. Rate inclusive of arrangement for approach and no extra cost on account of this factor will be entertained) |
| 52 | S & F 12mm thick toughned glass door in single/double leaf including stainless steel handles & stainless steel fixing arrangement fixed to ground/existing floor surface in cement concrete 1:2:4 B-1 type, incl locking arrangement with 02 sets of duplicate keys incl all required accessories such as cleat, desiner knob & handle etc.including provision of tinted / frosted glass film with the logo of the unit complete all as specified and directed. |
| 53 | Demolition of cement concrete (Un reinforced) in ground floors n.exc 15cm thick (above or below grnd level) complete all as specified |
| 54 | M&L for rendering 15 mm thick in CM 1:4 on any faces of concrete or brick surfaces finished even and smooth without using extra cement complete all as specified. |
| 55 | M & L for applying three coat of cement base paint on newly plastered surfaces of walls including preparation of new surfaces complete all as specified and directed. |
| 56 | Note:- Immediately after acceptance of contract, the contractor shall get the design of Main Gate SALARIA OFFICERS ENCLAVE as per direction of Engr-in-Charge with foundation design, suitably designed by structural consultant and vetted from Govt Engineering college, NIT/IIT before execution of work. The contractor shall consider aspect of payment of Fee to consultant while quoting the tender and No extra whatsover will be paid.DESIGN DATA:SBC = 100KN/m2 at 1.5 m depth.Wind terrain category 4 as per IS-875 Part-III |
| 57 | M & L for Point wiring in open cashing caping complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity conductor, with fabricated modular metal flush box duly make embossed, concealed in walls and with suitable size of modular inner and outer cover plates as required for housing modular switches , socket outlet and fan regulators etc , complete all as specified and directed for the followings:- |
| 58 | One light /Ceiling fan/exhaust fan point controlled by one switch. |
| 59 | One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. |
| 60 | One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board |
| 61 | All as per item No.56 herein before but with 4 Sqmm cable for one 3 pin 15 Amp switch socket outlet and using 4 sqmm PVC single core copper conductor cable multistranded as earth wire complete all as specified and directed. Note for Item 57&58 : (i) In case the wiring is encountered with any beam/column, then the wiring will run on PVC casing&caping/Existing conduit to avoid any damage to the RCC portion. (ii) No cutting shall be done in the roof for laying PVC conduit for ceiling fan point wiring, in this specified portion wires shall run through the surface new conduit shall be provided as mentioned in note (i) above.(iii) Proper colour code will be used for wiring as per the electrical rule and as directed by EIC. |
| 62 | M&L switch Modular type 6 Amp SP one way ISI marked complete all as specified and directed. |
| 63 | M&L switch Modular type type 16 Amp SP one way, ISI marked complete all as specified and directed. |
| 64 | M&LModular type socket outlet 5 pin 6 Amp flush type, ISI marked complete all as specified and directed. |
| 65 | M&L Modular type socket outlet 2 in 1,5 pin 6/16 Amps, ISI marked complete all as specified and directed. |
| 66 | M&L ceiling rose 3 terminals PVC polycorbonate,isolated body, complete all as specified and directed. |
| 67 | S & F Modular electronic fan regulator step type,2 module ,360 degree rotation complete all as specified and directed. |
| 68 | Supply and fix Air freshner fan PVC type ventilating single phase 230 volt of 250 mm sweep with louver shutter including making provision for fixing the ventilating fan on window/in wall all as specified and directed. |
| 69 | S&F factory made, sheet steel distribution boards, double door, protection class IP-42 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 200 Amps rating copper bus bar SPN 08 ways. |
| 70 | M&L MCB SPN 240 volt 32 Amp \\"B \\" curve |
| 71 | M&L MCB Lexic SP 6 to 32 Amp \\"B\\" curve. |
| 72 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 73 | Supply & fix in repair Slim concealed in panel round LED panel aluminium die cast body with premium diffuser to ensure glare free & even distribution of lights capacity 18/20 watts, 6500 K , Luminarie is >100lm/W complete with electric connection all as specified and directed by Engr-in-Charge. |
| 74 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete withIP 65/66 protection complete. |
| 75 | Supply and fixing 1100 volts grade heavy duty cable with PVC insulated aluminium solid conductor served with an inner sheathing of PVC armoured, PVC sheathed 6 sq. mm nominal cross section, 2 core. |
| 76 | M&L far Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, burieddirectly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed. |
| 77 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 900 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC). Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Sep 15, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Oct 01, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 2 daysOct 01, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender