Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #57321615

Tender For Misc Repair Works B/R And E/M Works And Cleaning Of Sewage Lines, Manholes, Septic Tank Etc To Md Accn Bldgs And Otm Bldgs Of Dad Residential Complex And Aao Shillong Under Ge Shillong

Issued by Statutory Bodies & Commissions/Committees · East Khasi Hills, Meghalaya
Tender Value
35 Lakhs
Estimated cost
Bid Submission
23 Sep 2026
18 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
East Khasi Hills → Meghalaya
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Misc Repair Works B/R And E/M Works And Cleaning Of Sewage Lines, Manholes, Septic Tank Etc To Md Accn Bldgs And Otm Bldgs Of Dad Residential Complex And Aao Shillong Under Ge Shillong

BOQ

Name of Work:- MISC REPAIR WORKS B/R AND E/M WORKS AND CLEANING OF SEWAGE LINES, MANHOLES, SEPTIC TANK ETC TO MD ACCN BLDGS AND OTM BLDGS OF DAD RESIDENTIAL COMPLEX AND AAO SHILLONG UNDER GE SHILLONG
Sl. No. Item Description
1Complete removal of existing treatment on wall/ceiling/concrete surfaces with Washing, rubbing, down and stopping of distempered and painted surfaces complete all as specified and directed.
2M&L for preparation of surfaces and applying putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed.
3M&L for preparation of surfaces and preparation of surfaces and applying one coat of oil bound distemper with roller on old treated surface of wall/ Ceiling etc complete all as specified and directed.
4M&L for preparation of surfaces and applying two coat of oil bound distemper with roller on old treated surface of wall etc complete all as specified and directed.
5M&L for preparation of old decorated plastered surfaces of ceiling and applying one coat of oil bond distemper on ceiling complete all as specified and directed.
6M&L for preparation of old treated surface of ceiling and applying one coat of white wash complete all as specified and directed.
7M&L for preparation of old treated wood or wood based surface of any description exceeding 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
8M&L for prepration of old treated steel surface of any description exceeding 10cm width or girth and applying one coat of synthetic enamelled paint complete all as specified and directed.
9M&L for preparation of old decorated surface on wall and applying one coat of Exterior emulsion paint ( weather coat), complete all as specified and directed.
10M&L preparation of old painted steel roof surfaces, over 10cm in with or girth and applying one coat of synthetic enamel roof paint complete all as specified and directed.
11Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
12M&L for light shade vitrified ceramic tiles 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:4 complete all as specified and as directed
13M&L for light shade vitrified ceramic tiles 10 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in CM 1:4 complete all as specified and as directed
14M&L for Non skid joint free ceramic tiles, 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile colour over 15mm thick screed bed in CM 1:4 complete all as specified and directed
15M&L for Non skid joint free ceramic tiles, 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile colour over 10mm thick rendering in CM 1:4 complete all as specified and as directed
16M&L for Glazed ceramic coloured tiles in vertical surface of size 300x450mm, 7-8mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match with the tile colour over 10mm thick backing coat in CM 1:4 complete all as specified and directed.
17M&L for Non skid joint free ceramic tiles, 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile colour over 15mm thick screed bed in CM 1:4 complete all as specified and directed
18M&L for outdoor coloured vitrified paving tiles, joint free(edge cut) of size 300x300x8 to 10mm thick as in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed
19M&L for outdoor coloured vitrified paving tiles, joint free(edge cut) of size 300x300x8 to 10mm thick as in skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement over 10mm thick rendering in CM 1:4 complete all as specified and as directed
20Demolition of PCC (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
21M&L 100 mm thick PCC 1:2:4 type B1 using 20mm graded stone aggregate as in hard standing finished even and fair laid in alterrnate bays of size not exc 2 m X 2m with construction joints and filled with joint sealing compound complete all as specified and directed.
22M&L 75mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection/hard standing finished even and fair with 10 mm joint filled with bitumen mastic (mix of bitumen and sand at 3m intervals complete all as specified and directed.
23Dismantling of plain or corrugated AC/ steel /fibre glass reinforced transluscent sheeting any guage thickness including nainital or similar pattern roof covering complete all as specified and directed.
24S&F pre-painted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick having tensile strength 550 Mpa as in roof covering / cladding to wall including fixing with self tapping screws washers, profile, shape and colour as approved by GE, complete all as specified and directed.
25S&F pre-painted Galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick having tensile strength 550 Mpa as in roof covering / cladding to wall including fixing with self tapping screws washers, profile, shape and colour as approved by GE, complete all as specified and directed.
26S&F 2 mm thick fibre reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof , wall etc complete all as specified and as directed
27Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
28M&L for roof truss ( framed), trussed , purlin etc. of angle or other section for fixing of sheets and similar works complete of Gde Fe-290(Gde E-165) complete all as specified and directed.
29M&L for prepration of new steel surface of any description over 10cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide/ zinc chrome primer complete all as specified and directed.
30Dismantling of wall/ceiling boards (fibre, pulp,insulation, etc.) or insulation boards/ slab/blankets, any thickness including cover fillets complete all as specified and directed.
31S&F Anodised Aluminium frame work for snap grid false ceiling comprising of Gl perimeter channnel 0.55 mm thick with Aluminium main T- flange of 25 mm and web of 30 mm fixed to surrounding wall angle with flange and web 25 mm each , Cross T with flange 25 mm and web 25 mm fixed to main T, Main T is suspended from soffit @ 1200 mm c/c using Gi wire of 4mm thickness, Aluminium frame will be 60cm x 60 cm to recieve ceiling board complete all as specified and directed.
32M&L for 4mm thick E - boards 600 mm x600 mm prepainted fibre boards ceiling designer/decorative type with different designs as approved by the GE fixed or laid in ceiling timber /GI/ aluminium frame work in ceiling flat or sloping complete all as per manufacturer instruction complete all as specified and directed.
33S&F For 10mm thick coloured PVC fluted louvers panels with EPS stuck to colour PVC sheet suitably placed in false ceiling/wall panelling, grid made of Aluminium/G.I/M.s or wooden fillets as per specification and drawing all as specified and directed.
34Taking down chowkhat with shutter (without taking off shutter from the frame) and area exc 1.5 sqm but n.exc 4 sqm each complete all as specified and directed.
35Taking down chowkhat with shutter (without taking off shutter from the frame) and area n.exc 1.5 sqm each complete all as specified and directed.
36Taking down shutters of any description exc 1.0 sqm but n. exc 2.0 sqm each complete all as specified and directed.
37Taking down shutters of any description n. exc 1.0 sqm each complete all as specified and directed.
38S&F 2nd class hard wood plain, solid, straight chawkhats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
39S&F 30mm thick flush shutter solid core construction with block board core and plywood face panels, decorative face veneer with lipping/frame to match on both sides complete all as specified and directed.
40S&F 2nd class hard wood glazed and skeleton shutters, 35mm thick, open rebated & prepared to receive wire gauge (with sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitread beads for securing glass etc, sizes of members of shutters as specified in SSR Pt-I, section 8, clause 8.24- (a), supplied and fitted to chowkats complete all as specified and directed.
41M&L 30mm thick 2nd class hard wood factory made glazed and skeleton shutter, open rebated and prepared to receive glass, gauge etc. devided into squares with plain chamfered or rounded, mitred and rebated sash bars edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Part-I Section-8 clause 8.24(b) complete all as specified and directed.
42S&F solid PVC door frame of size 50 mmx 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube as per specifiecation complete all as specified and directed.
43S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with single piece extruded pvc profile both side prelam PVC sheet 'C' channel having a 5mm thick PVC sheet strip of 20mm width stuck inside with solvent cement, forming stiles, and 5mm thick both side prelam single piece extruded pvc profile for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of both side prelam 5mm thick PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement complete all as specified and shown on drawing given in SSR Part II. The width of stiles & rails shall be in proportion to the width of the door shutter as given in SSR Part I complete all as specified and directed.
44M&L for 18/19 mm thick Prelaminated particle board, exterior grade, prelaminated one side with decorative choice laminations and other side balancing white lamination fixed with screws as in cabinet / cup-board completed all as specified and directed.
45S&F Continuous (Piano) hinges, brass, width of flaps 30 mm (when open) complete all as specified and directed.
46S&F in repair Magnet catches for cupboard shutter, brass body and striking plate including letting in complete all as specified and directed.
47S&F brass 150 mm long barrel tower bolts with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and directed.
48S&F extruded fancy type Brass handles fabricated type of size 100 mm complete all as specified and directed.
49S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and directed.
50S&F extruded aluminium alloy handles fabricated type anodised of size 150 mm complete all as specified and directed.
51S&F aluminium anodised barrel bolts and fixed of 100 mm length complete all as specified and directed.
52S&F butt hinges 100 mm medium weight mild steel cold rolled and fixed complete all as specified and directed.
53S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed.
54S&F Mild steel sliding door bolt, plate type stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, length of bolt 300mm complete all as specified and directed.
55Hacking out old broken glass (any thickness, size, quality or description) from wooden frame including taking out old wooden beads complete all as specified and directed.
56S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in square n exc 0.5 sqm in each pan complete all as specified and directed.
57S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
58S&F in repairs stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
59S&F in repair 25 mm dia aluminium drapery rod with wooden finish, decorative, including brackets, decorative finials at both ends (minimum) in one opening complete all as specified and directed.
60S&F in repair 600mm x 450mm beveled edge mirror of selected quality, glass 5mm thick, mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed.
61S&F in repairs Vitreous China Wash Hand Basins, size 550 X 400 mm (Flat Back or Angle Back type) including Pillar Taps 15mm Bore Cast Copper Alloy with Capstan Heads, Chromium Plated, fancy type, 32mm dia Brass Chromium Plated Waste Fitting and PVC connection pipe of 15mm x 600mm long, a Pair of Angle iron Brackets duly Painted/Erecting Stand including Cutting and Pinning in Ends, Making Good Disturbed Surfaces in Cement Mortar 1:3, complete all as specified and as directed.
62S&F in repair Water closet Pedestal pattern, white (excluding fixing bolts, flushing cistern and flush pipe) including plastic water closet seat, white/black, closed pattern with flat bottom and cover and mild steel chroimum plated or aluminised hinging device complete all as specified and directed.
63S&F in repair Vitreous china squatting pan, 'Orissa' pattern, size 580 X 440 mm white, with integral foot rests including provision of lime concrete bedding, fixing of flushing cistern complete all as specified and directed.
64S&F in repair Health faucet (ABS Body) mild steel chroumium plated suitable for 15mm dia pipe with 1.25metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
65S&F in repair PVC valveless, syphonic action type flushing cistern, low level, white, 10 Ltr capacity with inlet, ball valve, float and handle including brackets complete all as specified and directed.
66S&F in repair Bip tap, chromium plated, 15mm fancy type,complete all as specified and directed.
67S&F in repair Angular stop cock, fancy type, chromium plated, 15 mm bore complete all as specified and directed.
68S&F in repairs PVC connections 15 mm size with PTMT nuts of length 450mm complete all as specified and directed.
69S&F in repairs Brass Basin mixture CP mixer for mixing hot or cold water screwed down for iron pipe and fixed complete all as specified and directed.
70S&F in repairs CP wall mixer non telephonic complete all as specified and directed.
71S&F Stainless steel kitchen plate rack of size 31\\" X 30'' X 10\\" made out of stainless steel sheet of 1.00 mm with all accessories including taking down old unservicable rack complete all as specified and directed.
72S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs washers and wastes incl bedding in CM to dwarf wall or incl fixing cantilever brackets and connecting union to pipe overall size 915x460 mm bowl size 410mmx360mmx160 mm complete all as specified and directed.
73S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 1000 Ltrs incl taking down old unservicable tank of any description and in any position complete all as specified and directed.
74S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 500 Ltrs incl taking down old unservicable tank of any description and in any position complete all as specified and directed.
75Taking up or down steel tubing and connections for 15 mm bore of pipes complete all as specified and directed.
76Taking up or down steel tubing and connections for 20 mm bore of pipes complete all as specified and directed.
77S&F GI steel tubing medium grade 15mm bore with all fitting and fixed complete to wall and ceiling or laid under in floor complete all as specified and directed.
78S&F GI steel tubing medium grade 20mm bore with all fitting and fixed complete to wall and ceilings or laid in floors complete all as specified and directed.
79S&F in repairs Gun metal gate 20mm valve class I (ISI) marked with iron wheel head, screwed both ends for iron pipe, suitable for pipe complete all as specified and directed.
80S&F in repairs PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints, fixed to walls/floor including necessary sockets, fitting and clamps for securing pipe complete all as specified and directed.
81S&F in repair PVC (SWR) 75mm dia pipes single socketed in any length with rubber ring joints fixed to walls/floor including necessary sockets, fitting and clamps for securing pipe complete all as specified and directed.
82S&F in repairs PVC (SWR) bend with access door of any radius 110mm bore complete all as specified and as directed.
83S&F in repairs PVC (SWR) bend with access door of any radius 75 mm bore complete all as specified and as directed.
84S&F in repair 75mm dia PVC (SWR) floor trap with CP grating including jointing with solvent cement to pipe complete all as specified and directed.
85Excavation in trenches n. exc. 1.5 m wide and n. exc. 1.5 m depth and getting out in soft/ loose soil for foundation etc. complete all as specified and directed.
86Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25cm in soft/loose soil complete all as specified and directed.
87Removing excavated soils to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed.
88Demolition and breaking up drain pipes 150 mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
89Demolition and breaking up drain pipes 100 mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
90M&L Salt glazed stoneware drain pipes 150mm internal diameter of pipe laid in trenches and jointed as specified complete all as specified and as directed.
91M&L for Concrete bed to160mm drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
92M&L for Concrete bed to100mm drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
93M&L for Concrete bed to110mm drain pipes including packing under and completely surrounding pipes with concrete after they are laid and tested; in complete all as specified and directed.
94Cleaning of sewage lines using split Bamboo with a gunny bag piece tied with binding wire and inserting the bamboo in sewage lines through manhole/gully trap clear flow of sewage is observed of 100/150/200 mm bore pipe complete all as specified and directed.
95Dewatering and taking out/ removing sludge waste / foreign materials from septic tank using mechanical pump and disposal of raw water/effluent sludge/waste/foreign material by burying under ground borrow pit of suitable size and covering the pit with earth or earth mixed rubbish with spreading bleaching powder @ 1 kg per pit for disinfection purpose and removing surplus soil to a distance n.exc 50 m complete all as specified and directed.Note: Measurement of sludge (Solid/Semisolid) shall be taken after draining out of effluent/water over the accumulated sludge and cost of earthwork in excavation for earth pit and spreading of bleaching powder shall deemed to be included in the unit rate quoted by tender against these item complete all as specified and directed.
96Cleaning of manholes depth n.exc 1.50 mtr each, with spades or bucket, taking out sludge from manhole and disposed off aside by burying the entire sludge under ground in a earth pit dug of suitable size by putting earth mixed with rubbish in it and spreading bleaching powder surrounding the pit and again using water with bucket and put into manhole to clear the sludge and ensure the sludge is drain out completely etc complete all as specified and directed.Note: Cost of earth work in excavation for borrowing the pit and removing surplus soil to a distance n.exc 50m and spreading of bleaching powder around and over the pit shall be deemed to be included in the rate quoted.
97Cleaning of CI/RCC/PVC pipes of any dia from first floor to ground floor up to trap and 1st manhole along the wall, floor, including roding and removing waste material to a distance not exceeding 50mtr complete all as specified and directed.
98M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-l smooth finished, and reforming benching as required for 100 mm internal dia of pipe complete all as specified and as directed
99M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-l smooth finished, and reforming benching as required for 150 mm internal dia of pipe complete all as specified and as directed
100M&L 100mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in , sub-base for manholes finished even and fair or even and rough as reqd complete all as specified and directed
101Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
102M&L for precast RCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in cover slabs, shelves and similar articles set in CM (1:6) including necessary form work complete all as specified and directed.
103M&L for Mild steel TMT deformed bars, 10 mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality confirming to Fe 500D complete all as specified and directed.
104Demolition of precast concrete block walling built in cement mortar complete all as specified and directed.
105M&L Precast cement concrete block masonry with solid block exc 10 Cm in width, type C1 (1:3:6) (using 20mm graded stone aggregate) and setting in CM 1:6 complete all as specified and directed.
106M&L Precast cement concrete block masonry with solid block 10 Cm thick, type C1 (1:3:6) (using 20mm graded stone aggregate) with plain or interlocking joints and setting in CM 1:4 complete all as specified and directed.
107Taking down cement plaster on brick or concrete surfaces including raking out joints, hacking for key, scrubbing down with water, etc all as specified and directed.
108M&L for rendering 15mm thick in CM (1:4) in two coats (10mm and 5mm thick) mixed with water proofing compound with 5mm thick layer on fair faces of brick work or concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
109M&L for rendering 10mm thick in CM (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and directed.
110Supply only integral Water proofing compound (ISI Mark) complete all as specified and directed.
111M&L for preparation of new plastered surfaces of wall and applying two coats of cement based paint over a coat of primer complete all as specified and directed.
112M&L for preparation of new plastered surface of walls and applying two coats of acrylic distemper over a coat of alkali resistant priming paint over a coat of 1mm thick wall care putty complete all as specified and directed.
113M&L for preparation of new plastered surfaces of wall and applying two coats of white wash complete all as specified and directed.
114M&L 18-20 mm thick Granite stone slab (table rubbed and polished) in steps, jambs, pillars, window-cill, cooking plateform and like in cement mortar (1:4) including pointing in white cementcement with admixture of pigment to match the shade of granite stone including grinding and polishing, rounding to edges laid in any position over 15mm thick screed bed in CM 1:4 complete all as specified and as directed
115Cleaning and removing all scale and dirt, etc, from PVC/RCC/MS over head tanks by using wire brush, bleaching powder or lime etc of required quantity and washing with clean water from tank and from mouths of circulating pipes, etc after Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position of capacity exc 250 nexc 500 ltrs incl writing \\"TC on -DD/MM/YY\\" with white synthetic enamel paint with 5 CM font in capital letters complete all as specified and directed.
116Cleaning and removing all scale and dirt, etc, from PVC/RCC/MS over head tanks by using wire brush, bleaching powder or lime etc of required quantity and washing with clean water from tank and from mouths of circulating pipes, etc after Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position of capacity exc 500 nexc 1000 ltrs incl writing \\"TC on -DD/MM/YY\\" with white synthetic enamel paint with 5 CM font in capital letters complete all as specified and directed.
117S&F Collapsible gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc, as specified, errected in position and securing runners with holdfasts and brackets complete all as specified and directed.
118S&F powder coated (min powder coating 50 micron) anodised aluminium frame for Partition/doors, windows , ventilators plain or sliding type with one or more rebates including joining cleat for fixing etc complete all as specified and as directed
119S&F powder coated (min thickness of powder coating 50 micron) anodised aluminium door/ sliding door shutters , aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing , handles 2 nos in each door , hinges , anodised aluminium snap beading screws etc complete all as specified and as directed.
120S&F powder coated(powder coating min 50 micron) anodised window and ventilator shutters side hung/sliding type without sash , aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150 mm long(1 no) hinges type B-21 100 mm long (2 no) suitable handle (1 no ) complete all as specified and directed.
121M&L for 4.80 mm thick frosted sheet glass quality and glazing fixed to aluminium frame n'exc 0.50 sqm complete all as specified and as directed.
122Supply and fixing Sheet glass, 5.50mm thick ordinary quality, in squares, exceeding 0.50 sqm in each pane including one side affixed with one way vision film plain / pattern design of required colour, anti UV reflective and rubber packing etc complete all as specified and directed.
123Supply and fixing factory made 6mm thick powder coated anodised aluminium composite panel exterior grade, plain/pattern design minimum 0.50 mm thick aluminium sheet both side on solid polyethylene core (fire resistant) fixing to aluminium frame with necessary jointing/cover strips and screws etc complete all as specified and directed.
124Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion, embedded in concrete and making good disturbed ground complete all as specified and directed.
125Dismantling fencing wire mesh any type complete all as specified and directed.
126Dismantling wrought iron or mild steel work of any description not otherwise provided for.
127Supply only chain link mild steel galvanised fencing of mesh size 75mm x 75mm (design of mesh shall be approved by GE) made of GI wire not less than 3 mm dia including line wires, to any type of standards, rails, straining bolts, etc including provision of binding wire complete all as specified and directed
128Fixing only chain link mild steel galvanised fencing of any mesh and type to any type of standards, rails, straining bolts etc including provision of binding wire complete all as specified and directed
129S&F in repair galvanised two strand steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc. complete all as specified and directed (each line wire to be measured) complete all as specified and directed.
130S&F 10 mm dia MS round bars of any length as in stiffener to chain link fencing fixed to fencing post complete all as specified and directed .
131Excavation in post holes not exc. 0.5 cum, getting out returing, filling in and ramming earth and broken hard core/rubble mixed with earth with around the layers not exiding 25 cm each layers watering and removing surplus soil to a distance not exceeding 50 cm making good complete in soft/loose soil complete all as specified and directed.
132M&L for PCC (1:3:6), type C1 (using 20 mm graded stone aggregate) as in foundation filling and mass concrete including all necessary form work complete all as specified and directed.
133S&F mild steel angle iron or other sections for post and struts in fencing, flat iron fillets (for securing wire mesh etc) to fencing post, cut to shape, drilled and countersunk for screw, including cutting tops to shape as directed, drilling holes, notching for wire, embedding in concrete and screwing etc. conforming to Fe-290 Gde E-165 complete all as specified and directed.
134S&F MS screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc. 5 cm and n. exc 10 cm long, diameter of neck 5 to 10 mm complete all as specified and directed.
135S&F framed work as in doors or gates of angle or other section for fixing of sheets and similar works complete of Gde Fe-290(Gde E-165) all as specified and as directed
136Taking down carefully aluminium/copper conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified and directed.
137Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, including 20 mm dia PVC conduit on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild galvanised sunken box/metal flush box made out of 1.6 mm thick galvanised sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including accessories including cutting chases and making good the disturbed surfaces as per existing for one light point controlled by one switch complete all as specified and directed.
138All as per item No.137 above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and directed.
139All as per item No.137 above but 5 Amp socket on same board with other switches complete all as specified and directed.
140All as per item No.137 above but One call Bell point controlled by one bell Push on independent Board complete all as specified and directed.
141Material and labour point wiring for one light point controlled by one, Two way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including suitable size PVC conduit and fittings of medium grade fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. ncluding cutting chases and making good the disturbed surfaces as per existing complete all as specified and directed.
142Material and labour point wiring for power point controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including 20 mm width or higher size PVCconduit and fittings of medium grade fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. ncluding cutting chases and making good the disturbed surfaces as per existing complete all as specified and directed.
143Supply and fixing submain wiring for DBs/ Power Point, two single core ,4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked) including 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire including taking down old unserviceable one complete all as specified.
144Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, including 20 mm casing caping PVC on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild galvanised sunken box/metal flush box made out of 1.6 mm thick galvanised sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including accessories including making good the disturbed surfaces as per existing for one light point controlled by one switch complete all as specified and directed.
145All as per item No.144 above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and directed.
146All as per item No.144 above but 5 Amp socket on same board with other switches complete all as specified and directed.
147Material and labour point wiring for power point controlled by one, one way switch using 4 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including 20 mm width or higher size PVC casing caping and fittings of medium grade fitted with chromium plated brass screws & washers and 4 sqmm nominal cross sectioanl area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
148Supply and fixing submain wiring for DBs/ Power Point, two single core ,4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC casing caping (ISI marked) including 4 sqmm nominal cross sectional area multistranded copper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed.
149Supply and fixing modular switch 1 way 6 A module 230/250 volt , AC supply, ISI Marked, with cover plate complete all as specified and directed.
150Supply and fixing modular bell push 1 way 6 A module 230/250 volt , AC supply, ISI Marked, with cover plate complete all as specified and directed.
151Supply and fixing modular switch 2 way 6 A module 230/250 volt , AC supply, ISI Marked, with cover plate complete all as specified and directed.
152Supply and fixing modular sockets 6A 2/3 pin combined 2 module 230/250 Volts, 50 Hz , AC supply, ISI Marked complete all as specified and directed.
153Supply and fixing modular switch socket sockets 6A 2/3 pin combined 3 module 230/250 Volts, 50 Hz , AC supply, ISI Marked complete all as specified and directed.
154Supply and fixing modular switch socket sockets 6/16A 6 pin combined 3 module 230/250 Volts, 50 Hz , AC supply, ISI Marked complete all as specified and directed.
155S&F Modular cover plate with frame & flush box of 4 modules complete all as specified and directed.
156S&F Modular cover plate with frame& flush box of 3 modules complete all as specified and directed.
157S&F Modular cover plate with frame & flush box of 2 modules complete all as specified and directed.
158Supply & fix ceiling rose surface bakelite 65 mm x 50 mm three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed.
159Supply and fix Bell push, flush type, 5 amp complete all as specified and directed.
160Supply and fix Call Bell, Ding Dong AC. 230 volts, single pole complete all as specified and directed.
161Supply and fix 18 W LED light fitting wall mounted batten 4'ft , extruded aluminium housing, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 18 watt,6500/3000K including necessary connection including taking down old unserviceable one complete all as specified and directed.
162Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 6500/3000K 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size including taking down old unserviceable one complete all as specified and directed.
163S&F Wall bracket decorative LED fitting with lamp 10 Watt complete with necessary connection complete all as specified and directed.
164Supply and fixing in repair round/rectangular shape 12 watt 220 volts Warm/White AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.Note: (i) All fittings must be mentioned CA No. and date of intallation with permanent marker
165Supply & fix lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings complete all as specified and directed.
166Supply and fix 9 Watt LED bulb including taking down old unserviceable one complete all as specified and directed.
167Supply and fix switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed.
168Supply and fix socket outlets 2 in 1, 3 pin, 5/6 Amps flush type230/240 V complete all as specified and as directed. (For Same Board only)
169Supply and fix switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified and directed.
170Supply and fix switch socket combination 5 in 1 , 6 pin , (5/16 Amps ) flush type controlled by one switch complete all as specified and directed.
171Supply and fix in repair security light fittings 35 watts, minimumm system lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete with GI pipe dia 25mm with all accessories like clamps nut bolts etc. including connected with twin core twisted flexible copper conductor of suitable size including taking down old unserviceable one complete all as specified and directed.
172Supply and fix Distribution board double door MCB TPN 4 way with IP 43 multiphase outgoing suitable for mounting 63 Amps MCB as incomer with Bus bars, Neutral links complete with all accessories including taking down old unserviceable one including MCBs complete all as specified and directed.
173Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact including taking down old unserviceable one including MCBs complete all as specified and directed.
174Supply and fix MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessary connection complete all as specified and directed.
175Supply and fix MCB SPN 40 - 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessary connection complete all as specified and directed.
176Supply and fix MCB TPN 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessary connection complete all as specified and directed.
177Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including enlargement of hole and giving proper finishing including taking down old unserviceable one complete all as specified and directed.
178Supply and fix exhaust fan, plastic body AC single Phase. 230V of size 250mm sweep with, blades, and frame and louvers including enlargement of hole and giving proper finishing complete all as specified and directed.
179Material and labour in repair for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate and bentonite powder , using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I and testing on completion complete all as specified and directed.
180Taking down unserviceable lights removing carbon /loose connection and making street light/Post top lantern/bollard light serviceable including necessary T & P complete all as specified and directed.
181Supply and fixing of driver for LED luminary suitable for single phase 45 watts complete incl taking out of fitting from pole and refixing after repair complete all as per existing specification Make as per fitting fixed at site complete all as specified and directed.
182Supply and fixing of driver for LED Bollard 09 watt complete incl taking out of fitting and refixing after repair complete all as per existing specification Make as per fitting fixed at site complete all as specified and directed.
183Supply and fixing LED flood light 70 watt 230 V AC outdoor type with Efficacy > 100 LPW , 10 KV SPD with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp fixed on wall/roof/pole/floor/highmast with the help of nuts, bolts , washers and clamps etc complete all as specified and directed.
184Supply & fixing in repair Gate / Post Top lantern LED lights fitting of capacity 40 W die-cast aluminium body, 40 watt LED 3000/5700K and toughened glass complete with all accessories incl taking out old unserviceable one complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57321615
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 35 Lakhs
LAST DATE 23-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Misc Repair Works B/R And E/M Works And Cleaning Of Sewage Lines, Manholes, Septic Tank Etc To Md Accn Bldgs And Otm Bldgs Of Dad Residential Complex And Aao Shillong Under Ge Shillong
Basic Detail
Tender No GE/SHL/TOKEN-78 OF 2026-27
Bidding Type Tender
Location
City East Khasi Hills
State Meghalaya
Key Dates
Publish Date 02 Sep 2026
Submission Date 23 Sep 2026
Open Date 24 Sep 2026
Finance
Tender Value 35 Lakhs
Tender Fee 500
EMD 70000
Exemption Available
Document List
57105e88-fdd4-446f-bbb2-d1759650b75e.html
BOQ_882651.xls
TENDERDOCU78.pdf
Tendernotice_1 (8).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 02, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 19 days

Tender Documents

Download All (ZIP) ↓
html

57105e88-fdd4-446f-bbb2-d1759650b75e.html

xls

BOQ_882651.xls

pdf

TENDERDOCU78.pdf

pdf

Tendernotice_1 (8).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders