Tender For special Repair To Roof Treatment Of Otm Bldg No P-20,& P-21 Of Eme Bn And P-16 Of Arty Bde At Old Amritsar Cantt.
Tender Overview
Project Description
Tender for special Repair To Roof Treatment Of Otm Bldg No P-20,& P-21 Of Eme Bn And P-16 Of Arty Bde At Old Amritsar Cantt.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 15-Sep-2026 | BOQ | BOQ | 26-Sep-2026 |
| 2 | 15-Sep-2026 | Date | Date | 26-Sep-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Disconnecting existing tanks exc 250 ltrs but n exc 500ltrs cap, setting aside (or lowering of required) cleaning, etc. and hoisting if required reconnecting and refixing in position after Cleaning and removing all scale and dirt, etc., from tanks and from mouths of circulating pipes, etc complete all as specified and directed by Engineer-in-charge . |
| 2 | Cutting or uprooting grass on roofs, removing rubbish off the premises, cleaning surface and preparing to receive new plaster complete all as specified and directed by Engineer-in-charge . |
| 3 | Dismantling brick/PCC tiles laid in single layer jointed & pointed in cement mortar complete all as specified and directed by Engineer-in-charge . |
| 4 | Demolition of mud phuska in roofs, any thickness, including leeping plaster (whether full thickness removed or only a part thereof) complete all as specified and directed by Engineer-in-charge . |
| 5 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in mass concrete and roof padding and like including weathering slight rounded and throating complete all as specified and directed by Engineer-in-charge |
| 6 | M&L for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including cleaning surfaces etc complete all as specified and directed by Engineer-in-charge . |
| 7 | S&F (minimum) 3mm thick APP film based poly meric membrance minimum weighing 3Kg per Sqm reinforced with polyester non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application along the length of 100mm lapping strip to either sides and sealed in after cleaning down the roof by brooms complete all as specified and directed by Engineer-in-charge . |
| 8 | M&L for 40 mm thick brick/PCC tiles laid on 15mm thick cement mortar 1:6 and joints grouted flush in cement mortar ( 1:3) mixed with 5 % of crude oil by weight of cement complete all as specified and directed by Engineer-in-charge |
| 9 | All as per Srl Item No. 08 here-in-before above but except brick tiles. Note:- Old serviceable tiles obtained from serial No. 8 shall be reused. |
| 10 | M&L for cement concrete (1:2:4), type B-0 using 12.5mm graded stone aggregate as in benching, kerbs, mud stop, rounded or chamfered on edges including form work complete all as specified and directed by Engineer-in-charge |
| 11 | Demolition of Brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-charge |
| 12 | M&L for Brick work with sub class \\"B\\" bricks straight or curved on plan exc 6 m mean radius in CM 1:4 complete all as specified and directed by Engineer-in-charge . |
| 13 | All as per Srl item No. 12 here-in-before above but except bricks. Note :- Old serviceable Brick obtained from serial No. 11 shall be reused. |
| 14 | Taking down cement or cement lime plaster on brick walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed by Engineer-in-charge . |
| 15 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 using WPC 2% of weight of cement and finishing even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge . Note :- WPC will be measured and paid separately under relevant item. |
| 16 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces on walls in CM 1:6 finishing even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge . |
| 17 | M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces on ceiling in CM 1:3 finishing even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge . |
| 18 | M&L for preperation of newly plastered surfaces and applying three coats of white wash on ceiling including complete all as specified and directed by Engineer-in-charge . |
| 19 | M&L for preparation of newly plastered surface of wall and applying two coats cement base paint over a coat of primer to match the existing treatment complete all as specified and directed by Engineer-in-charge . |
| 20 | M&L for preparation of newly plastered surface of wall and applying two coats of oil bound distemper with necessary putty filling complete all as specified and directed by Engineer-in-charge . |
| 21 | Supply only integral water proofing liquid complete all as specified and directed by Engineer-in-charge . |
| 22 | Taking up or down existing steel water tubing 15mm dia alongwith connection fixes/laid in any situation complete all as specified and directed by Engineer-in-charge . |
| 23 | S&F 15mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-charge . |
| 24 | All as per Srl item No. 23 here-in-before above but except GI Pipe 15mm Note :- Old serviceable pipe obtained from serial No. 22 shall be reused. |
| 25 | Taking up or down existing steel water tubing 20mm dia alongwith connection fixes/laid in any situation complete all as specified and directed by Engineer-in-charge . |
| 26 | S&F in repair 20mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-charge . |
| 27 | All as per Srl item No. 26 here-in-before above but except GI Pipe 20mm Note :- Old serviceable pipe obtained from serial No. 25 shall be reused. |
| 28 | S&F Gun metal globe or gate valves 20mm bore with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed by Engineer-in-charge . |
| 29 | S&F in repair 110mm bore PVC(SWR) pipes single socketed in any length fixed to walls with nut and bolt and clamps at every 2mtr length including) including all fittings complete all as specified and directed by Engineer-in-charge by Engineer-in-charge |
| 30 | S&F in repair 110mm bore PVC (SWR) bends any radius With access door complete all as specified and directed by Engineer-in-charge by Engineer-in-charge |
| 31 | M&L for repairing of chajja / roof projection by taking down old plaster and applying 10mm thick rendering in cement mortar 1:3 including providing chicken mesh wire netting 25 gauge, 20 mm mesh, finishing the surface even & smooth with out using extra cement complete all as specified and directed by Engineer-in-charge by Engineer-in-charge |
| 32 | All as per ser item No. 14 above but of valve pit of internal dimension 450mm x 450mm x 600mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysCorrigendum-2 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender