Defence Statutory Bodies & Commissions/Committees Closing in 4 days TDR #57321578

Tender For special Repair For Conversion Of Ht Oh Line Into Ab Cables, And Connected Items Of Bana Enclave & Digiana And Ht Oh To Under Ground Cable Of Asc Pl At Bd Bari Mil Stn Under Ge Kaluchak.

Issued by Statutory Bodies & Commissions/Committees · Jammu, Jammu and Kashmir
Tender Value
69 Lakhs
Estimated cost
Bid Submission
07 Oct 2026
4 days left
EMD
1.29 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair For Conversion Of Ht Oh Line Into Ab Cables, And Connected Items Of Bana Enclave & Digiana And Ht Oh To Under Ground Cable Of Asc Pl At Bd Bari Mil Stn Under Ge Kaluchak.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 15-Sep-2026 Corrigendum No 01 BOQ 30-Sep-2026
2 30-Sep-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-Oct-2026

BOQ

Name of Work:- SPL REPAIR FOR CONVERSION OF HT OH LINE INTO AB CABLES, AND CONNECTED ITEMS OF BANA ENCLAVE & DIGIANA AND HT OH TO UNDER GROUND CABLE OF ASC PL AT BD BARI MIL STN UNDER GE KALUCHAK.
Sl. No. Item Description
1M & L for preparation of old painted surface of LT steel tubular electric pole including channel and clamps by removing all dirt, dust,etc and painting with two coat of synthetic aluminium paint over a coat of red oxide paint including making five strips of 30cm each upto 1.5 mtr above PCC pedal with two coats of black and white synthetic enamel paint including marking/numbering of pole number with transformer number by means of stencil complete all as directed by Engineer-in-Charge.
2M & L for preparation of Painting to concrete surfaces of PCC LT poles old painted surface with two coats of synthetic enamel paint in 30cm strips alternate layers with black & white colour upto 1.5 mtr length from PCC padel for LT pole including applying two coats of aluminium paint over cross arms and clamps, marking/numbering of pole with transformer number by means of stencils complete all as specified and directed by Engr in Charge.
3Supply & fixing in replacement of pin type insulators porcelain including one GI steel spindle, two GI washers and one GI nut 100mm height 65mm dia for 1100 volt grade.ISI Marked
4Supply & fixing in replacement of schackle insulators porcelain 75mm height and 90mm dia with GI fittings strap size 31x3mm, dia of bolt 12 mm with nuts, bolts & washers for working pressure 1100 volt.
5Supply & fixing in replacement of loop insulators vitreous porcelain large size with overall dimensions 90x140mm clearance of hole 25.50mm.
6M & L for Re-stretching, restraining ACSR conductor laid over, OH LT line on steel/PCC poles after removing the binding from insulators, lowering the ACSR conductor or broken OH line due to any reason, jointing the broken conductor, Re-winding the ACSR with insulators including providing binding wire, jumpering & connecting the existing service cables after re-stretching/Re-straining to OH line & removing unavoidable sag in the lines, complete all as specified in respect of three phase and neutral with street light feeder and guard wire.
7Description all as per Srl item No 06here in before but one phase and neutral with GI guard wire.
8M & L for Pruning of trees and branches along the LT over head electric lines, surrounding of LT/HT poles, panels Sub-STN bldgs & transformers at different location at 'Y' station and ridge area should be cleared upto 3mtr of outer edge of assets & removing/disposal of branches out side the cantonment area with prior permission of Engr-in-Charge.
9Supply and fixing in replacement of galvanized steel stay assembly complete with stay rod 20mm dia including stay strand 20 mm fixed for stay of poles for complete all as specified and directed by Engr-in-Charge. Note:- Earth work, PCC shall be measured and paid separately.
10Supply & fixing in replacement of OH LT lines line spacers, made from poly propylene composite phase separator moulded or bolted type for 5 lines total phase to phase distance 1200mm overall total length 1260mm, width 25mm, thickness 12mm.complete all as specified and directed
11Description all as per Srl item No 10 here in before but for 4 wires (Lines) phase to phase distance 900mm overall length 960mm, width 25mm, thickness 12mm complete all as specified and directed
12M & L for Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc complete all as specified and directed
13M & L for Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping of poles etc including necessary form work complete all as specified.
14M & L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) in stay assy, filling and mass concrete all as specified.
15Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cables & foundation of poles ,stay assembly and getting out in any type of soil complete all as specified and directed .
16Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
17Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
18Supply & laying dry river sand as cable cushioning 15cm thick layer before laying and 8cm thick over cable after laying the cable in trench complete all as specifieds and directed.
19Supplying and laying reinforced precast concrete cable cover class LV, type -I , flat, size 250x150x40 mm in trenches over under ground electric cable for mechanical protection complete all as specified and directed by E-in-Charge.
20Supply & Errecting truelly vertical position steel tubular swaged poles in replacement of UNSV /Broken PCC poles complete with CI base plate, finial taper plug bolts, nuts & screws 9.0 mtr long type 410 SP-31 including painting of poles with 2 coats of approved aluminium paint over a coat of red oxide, making five strips of black and white paint from PCC of size 30cm thick, numbering of pole with black or white colour by means of stencils all as specified and directed by Engg-in-Charge.
21Supply and fixing in replacement of Danger notice plate of 1.6mm thick MS sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal Red colour and inclusive fixed with MS flat clamps 25x3mm 2 Nos, nuts, bolts for LT 440 volt of size 20x15 cm all as specified and directed.
22Supply and fixing in replacement of anti climbing device, spikes type, fabricated out of MS bars (round, square or flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the poles, spike welded to flat iron, including on primer coat, one under coat and two finishing coats of silver aluminium paint including preparation of surfaces.complete all as specified and directed
23Supply and fixing in replacement of unserviceable GI wire and supply and fixing GI wire 3.15mm dia for guarding from pole to pole.complete all as specified and directed
24Dismantling and Supply & fixing cross Arms, bracings, supports, clamps etc fabricated from steel including nuts, bolts, washers, welding, bending, drilling holes for bolts in any shape or size as directed inclusive of one primer coat, one under coat and one finishing coat of aluminium paint all as specified and directed.
25Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS - 7098 Part-I (1988) with latest ammendments of sizes 16 Sq mm 2 core Cable all as spdf & directed
26Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS - 7098 Part-I (1988) with latest ammendments of sizes 16 Sq mm 4 core Cable all as spdf & directed
27Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS - 7098 Part-I (1988) with latest ammendments of sizes 25 Sq mm 4 core Cable.
28Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS - 7098 Part-I (1988) with latest ammendments of sizes 35 Sq mm 3.5 core Cable all as spdf & directed
29Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS - 7098 Part-I (1988) with latest ammendments of sizes 50 Sq mm 3.5 core Cable all as spdf & directed
30Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS - 7098 Part-I (1988) with latest ammendments of sizes 70 Sq mm 3.5 core Cable all as spdf & directed
31Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS - 7098 Part-I (1988) with latest ammendments of sizes 120 Sq mm 3.5 core Cable all as spdf & directed
32Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS - 7098 Part-I (1988) with latest ammendments of sizes 150 Sq mm 3.5 core Cable all as spdf & directed
33Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS - 7098 Part-I (1988) with latest ammendments of sizes 185 Sq mm 3.5 core Cable all as spdf & directed
34Supply, laying for replacement of unserviciable underground LT cable 1100 Volts grade heavy duty electric cable XLPE insulated & PVC outer sheathing with aluminium multistarended stranded conductor, Armoured confirming to IS - 7098 Part-I (1988) with latest ammendments of sizes 240 Sq mm 3.5 core Cable all as spdf & directed
35Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated multistranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape overall PVC Sheathed 10 sq mm, 2 core cable all as specified and directed.
36Supply and fixing in replacement GI pipe of size 80 mm light grade for floor, road cutting and protection of cable all as specified and as directed
37Supply and fixing in replacement GI pipe of size 50 mm light grade for floor, road cutting and protection of cable all as specified and as directed
38M & L for earthing complete with galvanised steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the plate not less that 1.5M below normal grouond level connected to GI earth wire 4 mm dia by means of nuts, bolts, check nuts, washers of galvanised iron or steel all as shown in electrical plate No 03 of SSR Part-I connected to earthing test point / DB including excavation / earth work in any type of strata, removal of surplus earth, GI pipe for watering pipe with and funnel, PCC 1:3:6 Type C-1 chamber with 40 mm thick RCC 1:2:4 type B-1 in cover slab with TMT bars @ 150 mm c/c both way with GI protection pipe complete all as specified and directed by Engineer-in-Charge.
39M&L for earthling complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 meters below normal ground level surrounded from all sides by mixture of charcoal & common salt & electrode connected to and including galvanised earth strip 25x4mm as earthling lead by means of bolts, nuts, check-nuts, and washers of galvanised iron and GI protection pipe light grade 15 mm dia connected to earth point , GI pipe light grade 20 mm dia for watering funnel with wire mesh all as specified & indicated in Electric plate no 3 of SSR 2009 part I complete .
40M&L for earthling complete with galvanised steel earth plate electrode 600x600x6mm thick, buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 meters below normal ground level surrounded from all sides by mixture of charcoal & common salt & electrode connected to and including galvanised earth strip 32x6mm as earthling lead by means of bolts, nuts, check-nuts, and washers of galvanised iron and GI protection pipe light grade 15 mm dia connected to earth point , GI pipe light grade 20 mm dia for watering funnel with wire mesh all as specified & indicated in Electric plate no 3 of SSR 2009 part I complete .complete all as specified and directed
41M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 25X4 mm dia galvanised iron strip.
42M & L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4 mm dia galvanised iron or steel wire.
43M&L for Bus bar chamber of size 750 x 600 x 500 mm outdoor pedestal type, factory made, powder coated made out of 3.15 mm thick CRCA sheet dust and vermin proof complete with openable shutter in front and rear having proper locking arrangement, duly powder coated with 250 Amp 415 V 4 pole MCCB as incommer control and including 400Amps, 4 pole Aluminium bus bar mounted on insulator, suitable for 3 phase, 415 volts, 50 Hz AC supply including control wiring to panel with suitable size of PVC insulated and sheathed copper cable, duly mounted on angle iron frame 50x50x6 mm including necessary PCC foundation work in all respect with phase indicator lamps (R, Y. B) – 01 Set. all as specified.
44Supply & fix thermoplastic polystyrene polycarbonate enclosures, shock proof, with IP 66 protection junction box of size 210 X 155 X 92 mm with suitable connector for three phase loop in loop out branch out and vibration proof connection and fixing on PCC or MS Electric poles using MS clamp 02 Nos made out of 25mm x 3mm MS strip and nuts & bolts of required size all as directed by Engr-in-charge.
45M & L for cable jointing kit outdoor type, heat shrinkable straight through type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 10 to 16 Sqmm 4/3.5 core cables all as directed and specified.
46M & L for cable jointing kit outdoor type, heat shrinkable straight through type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 25 to 50 Sqmm 4/3.5 core cables all as directed and specified.
47M & L for cable jointing kit outdoor type, heat shrinkable straight through type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 70 Sqmm 4/3.5 core cables all as directed and specified.
48M & L for cable jointing kit outdoor type, heat shrinkable straight through type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 95 Sqmm 3.5 core cables all as directed and specified.
49M & L for cable jointing kit outdoor type, heat shrinkable straight through type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 120 Sqmm 3.5 core cables all as directed and specified.
50M & L for cable jointing kit outdoor type, heat shrinkable straight through type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 150 Sqmm 3.5 core cables all as directed and specified.
51M & L for cable jointing kit outdoor type, heat shrinkable straight through type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 185 Sqmm 3.5 core cables all as directed and specified.
52M & L for cable jointing kit outdoor type, heat shrinkable straight through type including all jointing material & accessories suitable for 1100 Volt grade LT aluminium conductor cables of size 240 Sqmm 3.5 core cables all as directed and specified.
53Material and labour for Cutting of wild grass ,bushes ,unwanted vegetation trees upto 30 cm grith including roots from inside/surrounding of installations ,2 / 4 pole structure including cutting of bushes along barbed/cattle fencing of the installation comlete all as specified and directed by Engr-in-charge.
54M & L hardcore of broken stone of gauge exc 40 mm deposited spread and leveled in layers n.exc 15cm thick watered and well rammed to a true surface in 2/4 pole structure / GOD and Sub station after sand cushioning . complete and all as specified directed by engr-in-charge.
55M & L for Plain cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping of Transformers plate form etc including necessary form work complete all as specified.
56Supply, installation, testing & commissioning in replacement of totally enclosed feeder pillar, outdoor type, fabricated out of 3.15 mm thick CRCA sheet, dust and vermin proof, powder coated, double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete) suitable for operating on 415 Volts, 50 Hz, AC supply. internally wired with copper conductor, having legs 90 cms & made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cm. Brick masonary platform should be 60 cm above the ground Level. and comprising the following:- (a) Aluminium bus bar 500 Amps TPN of suitable length and of cross section as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts- 01 Set Incomer :- MCCB 4 pole 315 Amp, 36 KA and thermal & magnetic releases with Ics=100%Icu. confirming to IEC 60947-2 with short circuit and over load protection. -01 No Out Goings:-(c) MCCB 4 pole 100 Amp, 25 KA and thermal & magnetic releases with Ics=100%Icu. confirming to IEC 60947-2 with short circuit and over load protection. -03 Nos (Out going)(d) MCCB 4 pole 63 Amp, 25 KA -02 Nos( 01 Spare)(e) MCB DP 32 Amp 240 Volts -02 No (Outgoing).(01 Spare) (f) Digital type amp meter 0-500Amp with CT’s & selector switch - 01 No(g) LED Indicating lamp (RYB-one set) (g) Digital voltmeter 0-500 volts with selector switch-01 NoNote:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI, depth of the panel not less than 50 cm. (iii) Cost for construction of platform for panel of brick masonary work built in cement mortar 1:6 with foundation in 100mm thick PCC 1:4:8 type D-2 including plaster work in cement mortar 1:4 , 50mm thick coping in PCC 1:2:4 type B-1 deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing)
57Supply, installation, testing & commissioning in replacement of totally enclosed bus bar panel, outdoor type, fabricated out of 3.15 mm thick CRCA sheet, dust and vermin proof ,powder coated, double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete) suitable for operating on 415 Volts, 50 Hz, AC supply internally wired with copper conductor having legs 90 cm & made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cm. Brick masonary platform should be 60 cms above the ground level and comprising the following:- (a) Aluminium Bus Bar 1000 Amps TPN of length suitable for fixing minimum 6 cables and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts-01 Set (b) Incomer :- MCCB 630 Amp,4 pole, 36 KA having thermal & magnetic releases with Ics=100%Icu. conferming to IEC 60947-2 with short circuit and over load protection. (as incoming) -01 No Outgoings:-(c) MCCB 250 Amp,4 pole,25 KA having thermal & magnetic releases with Ics=100%Icu. confirming to IEC 60947-2 with short circuit and over load protection -04 Nos (01 spare)(d) MCCB 63 Amp,4 pole, 16 KA having thermal and magnetic releases with Ics=100%Icu. conferming to IEC 60947-2 with short circuit and over load protection.(as incoming and outgoing) -02 No (01 Spare)(f) Digital type amp meter 0-500Amp with CT’s & selector switch - 01 No. (g) LED Indicating lamp (RYB-one set) (h) Digital voltmeter 0-500 volts with selector switch -01 No Note:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI depth of the panel not less than 50 cms. (iii) Cost for construction of platform for panel of brick masonary work in CM 1:6 with foundation PCC 1:4:8 type D-2 including plaster work, PCC copping 1:2:4 (40 mm thick stone aggerate), deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing).
58Supply, installation, testing & commissioning in replacement of totally enclosed feeder pillar, outdoor type, fabricated out of 3.15 mm thick CRCA sheet, dust and vermin proof, powder coated, double door type (independent cabin including locking arrangement for each MCCBs, bus bar chamber enclosed complete) suitable for operating on 415 Volts, 50 Hz, AC supply. internally wired with copper conductor, having legs 90 cms & made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cm. Brick masonary platform should be 60 cm above the ground Level. and comprising the following:- (a) Aluminium bus bar 630 Amps TPN of suitable length and of cross section as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts- 01 Set (b) MCCB 4 pole 400 Amp, 36 KA and thermal & magnetic releases with Ics=100%Icu. confirming to IEC 60947-2 with short circuit and over load protection. -01 No (Incoming)(c) MCCB 4 pole 160 Amp, 25 KA and thermal & magnetic releases with Ics=100%Icu. confirming to IEC 60947-2 with short circuit and over load protection. -03 Nos (Out going)(c) Change over switch 100 A, 4 pole -02 No( Rotary Handle Type)(d) MCB DP 32 Amp 240 Volts -01 No (Outgoing). (e) Digital type amp meter 0-500Amp with CT’s & selector switch - 01 No(f) LED Indicating lamp (RYB-one set) (g) Digital voltmeter 0-500 volts with selector switch-01 NoNote:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI, depth of the panel not less than 50 cm. (iii) Cost for construction of platform for panel of brick masonary work built in cement mortar 1:6 with foundation in 100mm thick PCC 1:4:8 type D-2 including plaster work in cement mortar 1:4 , 50mm thick coping in PCC 1:2:4 type B-1 deemed to be included in the item rate. No Extra payment will be made. (iv) MCCB's should be connected with extensions terminals at both side (incoming and outgoing)
59S&F totally enclosed bus bar feeder pillar, outdoor type, fabricated out of 3.15 mm thick CRCA sheet, dust and vermin proof, powder coated, double door type complete suitable for operating on 415 Volts, 50 Hz, AC supply, having legs 90 cm and made out of 50x50x6 mm angle iron grouted on brick masonary platform upto 45 cm. Brick masonary platform should be 60 cm above the ground level and comprising the following:- (a) Aluminium Bus Bar 500 Amps TPN of length suitable for fixing minimum 6 cables and of crossection as per design with colour codding. Bus bars shall be designed to with stand a fault level of 36 KA at 415 volts-01 Set(b) Digital type amp meter 0-500Amp with CT’s & selector switch - 01 No. (c) LED Indicating lamp (RYB-one set) -01 No(d) Digital voltmeter 0-500 volts with selector switch-01 NoNote:- (i) The panel shall be front operated with cable entry from the bottom with cable glands. Earth bus shall be part of the main feeder pillar. (ii) Fabrication of feeder pillar box to be approved by CPRI.(iii) Cost for construction of platform for panel of brick masonary work built in cement mortar 1:6 with foundation in 100mm thick PCC 1:4:8 type D-2 including plaster work in cement mortar 1:4 , 50mm thick coping in PCC 1:2:4 type B-1 deemed to be included in the item rate. No Extra payment will be made. (iv) After fixing the bus bar panel, all electric connections will be made without any extra cost all as specified and directed.
60Taking out broken hinges/unserviceable hinges & door handles from feeder pillar/LT Panel and replace the same with mild steel hinges cold rolled of same size through spot welding & Mild steel sliding door bolt of same size including making necessary adjustment for free and smooth movement of panel and spray painting two coats of powder coating inside & outside the panel complete all as specified and directed.
61Taking out the damaged/deshaped part/portion of the LT Panel/feeder pillar and repalce the same with new portion made out of CRCA sheet 3mm thick including making necessary adjustment and allignment to make the existing feeder pillar/LT Panel to its required shape and size including spray painting two coats of powder coating inside & outside the panel complete all as specified and directed
62Taking out the existing unserviceable voltmeter, ammeter, phase indication lamps, CTs of any description and size and S&F digital voltmeter, ammeter, phase indication lamps,CTs as per existing capacity and sizes complete all as specified and directed.
63S&F in replacement MCCB 630 Amp, 4 pole, 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
64S&F in replacement MCCB 400 Amp, 4 pole, 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
65S&F in replacement MCCB 315 Amp, 4 pole, 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
66S&F in replacement MCCB 250 Amp, 4 pole, 36 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
67S&F in replacement MCCB 200 Amp, 4 pole,25 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
68S&F in replacement MCCB 160 Amp, 4 pole,16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
69S&F in replacement MCCB 125 Amp, 4 pole,16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
70S&F in replacement MCCB 100 Amp, 4 pole,16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
71S&F in replacement MCCB 63 Amp, 4 pole,16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
72S&F in replacement MCCB 100 Amp, 3 pole,16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
73S&F in replacement MCCB 125 Amp, 3 pole,16 KA, thermal and magnetic releases with Ics=100%Icu. conforming to IS/IEC 60947-2 and IEC 60947-2 with short circuit and over load protection. Outgoing and incoming spreaders should be provided for connecting cable without any extra cost complete all as specified and directed.
74S&F in replacement MCB DP, 40 Amps, 10 KA, C curve including making all connections with proper thimbling and connectors complete all as specified and directed.
75S&F in replacement MCB DP, 32 Amps, 10 KA, C curve including making all connections with proper thimbling and connectors complete all as specified and directed.
76S&F in replacement MCB SP, 6 to 32 Amps, 10 KA, C curve including making all connections with proper thimbling and connectors complete all as specified and directed.
77S&F in replacement contactor MO C3 complete all as specified and directed.
78S&F in replacement contactor MO C5 complete all as specified and directed.
79S&F in replacement contactor MO C10 complete all as specified and directed.
80S&F in replacement contactor MO C15 complete all as specified and directed.
81S&F in replacement contactor MO C20 complete all as specified and directed.
82S&F in replacement MCB TP, 20A, C curve in existing panels with proper thimbling complete all as specified and directed.
83S&F in replacement MCB TP, 40A, C curve in existing panels with proper thimbling complete all as specified and directed.
84S&F in replacement APP technology standard duty capacitor 1 Kvar in existing panels all as specified and directed.
85S&F in replacement APP technology standard duty capacitor 2 Kvar in existing panels all as specified and directed.
86S&F in replacement APP technology standard duty capacitor 5 Kvar in existing panels all as specified and directed.
87S&F in replacement APP technology standard duty capacitor 10 Kvar in existing panels all as specified and directed.
88S&F in replacement onload change over switch, 63 Amp, 415V, AC, 4 pole front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc complete all as specified and directed.
89S&F in replacement onload change over switch, 100 Amp, 415V, AC, 4 pole front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc complete all as specified and directed.
90S&F in replacement onload change over switch, 160 Amp, 415V, AC, 4 pole front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc complete all as specified and directed.
91S&F in replacement onload change over switch, 200 Amp, 415V, AC, 4 pole front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc complete all as specified and directed.
92S&F in replacement onload change over switch, 250 Amp, 415V, AC, 4 pole front openable type in sheet steel enclosure including fixing arrangements in existing panel/on wall, including provision of thimble, nut bolts etc complete all as specified and directed.
93Supply, installation, testing and commissioning in repair of outdoor automatic power factor control panel, 40 KVAR, suitable for operation at 415V, 3 phase AC 50 Hz power supply, floor mounted, compartmentalised, load bearing structure of panel fabricated out of 3.15 mm CRCA sheet, partitions, doors etc made of 2mm thick sheet with KIOSK type body having openable front and back doors. The panel shall have angle iron mounting base frame of 600 mm height made out of 50x50x5 mm angle iron. General arrangement drawing shall be got approved before commencing manufacturing. The panel duly powder coated with RAL 7032 shade consisting of following components :-(A) Incomer:(i) MCCB 100A,3 pole ,25 KA having adjustable thermal release -01 No(ii) 3 phase LED indications with control MCBs of 6A SP-01 Set(iii) Aluminium Busbar 200A, TPN, EC grade mounted on DMC supports insulated with color coded heat shrinkable sleeves.-01 No(iv) 3 phase 10 KVAR capacitor can- type 440 volts-04 Nos(v) 3 phase 10 KVAR capacitor duty contactor with additional contact block -04 Nos(vi) MCB 32A, 3P,10 KA-04 Nos (vii) Automatic power factor controller 4 Step with control circuits for Auto/Manual operation of Individual bank, ON indication for each capacitor, control MCBs, copper wiring, power wiring for capacitor banks using suitable size copper wires.-01 No
94Disconnecting existing electrical connections,dismantling,opening, servicing, cleaning existing autmatic voltage stabilizer for automatic operation, oil cooled ,servo controlled type of capacity 100 KVA and refixing/re-installating the same complete all as specified and directed. Note : (i) Replacement of parts (if any) found damaged during repair shall be measured and paid separately.
95Disconnecting existing electrical connections,dismantling,opening, servicing, cleaning existing autmatic voltage stabilizer for automatic operation, oil cooled ,servo controlled type of capacity 50 KVA and refixing/re-installating the same complete all as specified and directed. Note : (i) Replacement of parts (if any) found damaged during repair shall be measured and paid separately.
96Disconnecting existing electrical connections,dismantling,opening, servicing, cleaning existing autmatic voltage stabilizer for automatic operation, oil cooled ,servo controlled type of capacity 20 to 40 KVA and refixing/re-installating the same complete all as specified and directed. Note : (i) Replacement of parts (if any) found damaged during repair shall be measured and paid separately.
97S&F in replacement diameter coil with supper enameled copper wire for voltage stabilizer of capacity100 KVA complete all as specified and directed.
98S&F in replacement diameter coil with supper enameled copper wire for voltage stabilizer of capacity 50 KVA complete all as specified and directed.
99S&F in replacement diameter coil with supper enameled copper wire for voltage stabilizer of capacity 20 to 40 KVA complete all as specified and directed.
100Dismantling and rewinding of dimmer coil with super enameled copper wire including varnishing tapping and insulating material of voltage stabilizer of capacity 100 KVA complete all as specified and directed.
101Dismantling and rewinding of dimmer coil with super enameled copper wire including varnishing tapping and insulating material of voltage stabilizer of capacity 50 KVA complete all as specified and directed.
102Dismantling and rewinding of dimmer coil with super enameled copper wire including varnishing tapping and insulating material of voltage stabilizer of capacity 20 to 40 KVA complete all as specified and directed.
103M&L for dismantling of primary & secondary coils of capacity 100 KVA carefully, taking out winding wire, preparing for rewinding with super enameled copper winding wire of appropriates gauge with allied insulating material, varnishing the winding with air drying, insulating varnish, heat treatment complete all as specified and directed.
104M&L for dismantling of primary & secondary coils of capacity 50 KVA carefully, taking out winding wire, preparing for rewinding with super enameled copper winding wire of appropriates gauge with allied insulating material, varnishing the winding with air drying, insulating varnish, heat treatment complete all as specified and directed.
105M&L for dismantling of primary & secondary coils of capacity 30-45 KVA carefully, taking out winding wire, preparing for rewinding with super enameled copper winding wire of appropriates gauge with allied insulating material, varnishing the winding with air drying, insulating varnish, heat treatment complete all as specified and directed.
106M&L for replacement of printed circuit board (PCB) complete all as specified and directed.
107M&L for replacement of dimmer brush with carbon brush & brush holder complete all as specified and directed.
108M&L for replacement of analog amp meter 96 sqmm, 0-200 amps with CTs complete all as specified and directed.
109M&L for replacement of analog volt meter 0-500 volts with selector switch complete all as specified and directed.
110M&L Repalcement of internal wiring for DC supply with suitable size of LT panels complete as as specified and directed.
111M&L for replacement of brass studs fixed for input & output of stabilizer of 100 KVA capacity with brass nuts complete all as specified and directed.
112M&L for replacement of brass studs fixed for input & output of stabilizer of 50 KVA capacity with brass nuts complete all as specified and directed.
113M&L for replacement of brass studs fixed for input & output of stabilizer of 20 KVA to 50 KVA capacity with brass nuts complete all as specified and directed.
114S&F digital volt meter 0-500 volt with selector switch complete all as specified and directed
115S&F digital Amp meter 0-400 Amp with selector switch complete all as specified and directed
116S&F indicator lamp set (RYB) complete all as specified and directed Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57321578
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 69 Lakhs
LAST DATE 07-10-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair For Conversion Of Ht Oh Line Into Ab Cables, And Connected Items Of Bana Enclave & Digiana And Ht Oh To Under Ground Cable Of Asc Pl At Bd Bari Mil Stn Under Ge Kaluchak.
Basic Detail
Tender No CWE/T-64/2026-27
Bidding Type Tender
Location
City Jammu
State Jammu and Kashmir
Key Dates
Publish Date 30 Sep 2026
Submission Date 07 Oct 2026
Open Date 10 Oct 2026
Finance
Tender Value 69 Lakhs
Tender Fee 1000
EMD 1.29 Lakhs
Exemption Available
Document List
b453bda1-fdcc-4c27-b20f-49da6da4842e.html
BOQ_882517.xls
TENDER64merged.pdf
Tendernotice_1 (8).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 30, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 30, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Oct 07, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 4 days
Oct 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Oct 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

b453bda1-fdcc-4c27-b20f-49da6da4842e.html

xls

BOQ_882517.xls

pdf

TENDER64merged.pdf

pdf

Tendernotice_1 (8).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders