Tender For Jambutake Industrial Area..... Permanent Water Supply Scheme And Providing Infrastructure Facilities.... Construction Of Jackwell, Approach Road, Approach Bridge, 1.50 Mld Capacity Wtp, 300 Cum Esr, 1000 Cum Sump And Providing Pumping Mach
Tender Overview
Project Description
Tender for Jambutake Industrial Area..... Permanent Water Supply Scheme And Providing Infrastructure Facilities.... Construction Of Jackwell, Approach Road, Approach Bridge, 1.50 Mld Capacity Wtp, 300 Cum Esr, 1000 Cum Sump And Providing Pumping Machinery For Water Supply Scheme Of Jambutake Industrial Area, Construction Of Roads, Providing, Laying And Jointing Of Distribution Network In Industrial Area, Providing, Erecting Testing & Commissioning Of Street Light, Shifting Of 33Kv Or 11 Kv Ht/Lt Lines And Dtc, Construction Of Plug & Play Sheds And Convention Center With Internal Electrification Arrangement & Providing Power Supply Arrangement With 11 Kv Ht&Lt Network With 200 Kva Dtc.
BOQ
| Sl. No. | Item Description |
| 1 | As per Schedule \\"B\\"Jambutake Industrial Area..... Permanent water supply scheme and providing infrastructure facilities.... Construction of Jackwell, Approach road, Approach bridge, 1.50 MLD capacity WTP, 300 cum ESR, 1000 cum sump and providing pumping machinery for water supply scheme of Jambutake Industrial Area, construction of Roads, providing, laying and jointing of distribution network in Industrial Area, Providing, erecting testing & commissioning of street light, Shifting of 33KV or 11 KV HT/LT lines and DTC, Construction of plug & play sheds and convention center with internal electrification arrangement & providing power supply arrangement with 11 KV HT< network with 200 KVA DTC. |
| 2 | Designing (aesthetically), providing and constructing high rate Unconventional Water Treatment Plant i.e. Simplified Water Treatment Plants consisting of Civil Works, including cost of providing and applying Epoxy paint to inside surface of water retaining structures in contact with Chlorine and providing anti-termite treatment to entire structure below ground level, Mechanical and Electrical components of variours sub- works as given below : including necessary hydraulic testing, structural testing and trial run for 3 months, etc. complete as directed by Engineer-in-charge . |
| 3 | Designing (aesthetically), and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5 metres centre to centre for ESR having capacity upto 500 cum and not more than 6 m c/c for ESRs having capacity above 500 Cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling disposing off the surplus stuff within a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental design, providing and fixing accessories such as M.S. ladder, C.I. manhole frame and covers, water level indicators, lightening conductor, G.I. pipe railing around walk way and top slab, providing spiral stair case from ground level to roof level, M.S. grill gate of 2 M height with locking arrangement of approved design, B.B. masonry chambers for all valves, ventilating shafts, providing and applying three coats of cement paint to the structure including roof slab, epoxy painting to internal surface and anti-termite treatment for underground parts of the structure and giving satisfactory water tightness test as per I.S. code. The job to include painting the name of the scheme and other details on the reservoir as per the directions of Engineer-in-Charge. |
| 4 | Designing (aesthetically), and constructing RCC ground service reservoirs / RCC sumps in M-300 mix of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion to inside face of the container, including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 M, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bypass arrangement consisting of C.I. M.S. D/F. pipes, specials and valves of given diameters, providing and fixing accessories such as M.S. ladder inside and outside, C.I. Manhole frame and cover, water top slab, B.B. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per IS code and providing three coats of cement paints to all exposed surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. Anti-termite treatment shall be given for underground portion of the structure. |
| 5 | As per Schedule \\"B\\" |
| 6 | Jambutake Industrial Area..... Permanent water supply scheme and providing infrastructure facilities.... Construction of Jackwell, Approach road, Approach bridge, 1.50 MLD capacity WTP, 300 cum ESR, 1000 cum sump and providing pumping machinery for water supply scheme of Jambutake Industrial Area, construction of Roads, providing, laying and jointing of distribution network in Industrial Area, Providing, erecting testing & commissioning of street light, Shifting of 33KV or 11 KV HT/LT lines and DTC, Construction of plug & play sheds and convention center with internal electrification arrangement & providing power supply arrangement with 11 KV HT< network with 200 KVA DTC. |
| 7 | Providing, erecting, testing & commissioning of pumping machinery & allied accessories at raw water pumping station at Jackwell, Waghad dam. |
| 8 | Providing, installing, commission and testing of VERTICAL TURBINE, self water lubricated above floor type pump capable of discharging raw water at the rate of 50 Cum/ Hr. at the duty point head of 108 Mtr. and operating within the head range of 96 to 118 Mtr. at a speed of 1450 RPM with foundation frame, CF8M impeller, CI casing suitable coupling with all allied material, cutting welding etc. & VHS SPDP induction motor, developing 26 KW i.e.35 HP with \\"F\\" class insulation and thermostat protection embedded in stator winding, operating on 50 cycles, 415 Volts complete with terminal box suitable for 3 core x 25 sqmm, 1.1 KV PVC armored Aluminum cables etc. complete as per specification. |
| 9 | Designing, manufacturing testing and commissioning of L.T. switch board panel consisting of incomer with 200 A 4P MCCB with 200 A 4P Changeover switch, 3 No. outgoing feeders for 3 Nos. of 35 HP FCMA starters with 3 No. of 100 A 3P MCCB main FCMA Incomer, main contactors & bypass starter & FCMA starter, 2 No. of 63A FP MCB, 4 Nos. of 32A FP MCB for auxiliary loads, spare feeder & copper bus bar of suitable ratings etc. complete as per detailed specifications. |
| 10 | Designing, manufacturing testing and commissioning of L.T. switch board APFC panel having main incomer & outgoing of MCCB of suitable rating, Copper bus bar of suitable ratings with total 50 KVAR APFC set as per capacitor banks of various capacities 10 KVARx2, 5KVARx2, 3KVARx4, 2KVARx4 along with 7% Aluminium reactor & heavy duty contactor for all steps etc. complete as per detailed specifications. |
| 11 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3 core 25 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 12 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 13 | Providing erecting Cast Steel/ Spheroidal Graphite (S.G) Iron D/F Sluice Valves / Butterfly Valves with jointing to pipe work (including all hardware and packing) water works quality, having non-rising spindle with hand wheel and without bypass arrangement, spindle of stainless steel as per requirement, inspection charges, transportation upto departmental store, unloading, stacking, excluding GST levied by GOI & GOM in all respect etc. excluding C. C. foundation / structural steel support.3)Sluice Valve- 150 mm dia.a) Sluice Valves. CS-150 |
| 14 | Providing erecting Cast Steel /Spheroidal Graphite (S.G.) Iron D/F Reflux Valves Single Door with jointing to pipe work (including all hardware and packing) water works quality with jointing to pipe without bypass arrangement, with gunmental seats including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. completed but excluding C. C. foundation / structural steel support.For Rating Class 150 (Working Pressure 20 kg/cm2 and Test Pressure 30 kg/cm2)3) Reflux Valve- 150 mm |
| 15 | Providing and supplying at site ductile iron / Spheroidal Graphite (S.G.) iron single / Double chamber tamper proof air valve with isolating sluice valve. Valves in accordance with BSEN 1074-4 of PN 10/16 rated, with body and bonnet of ductile iron confirming to EN 1563/IS 1865 Gr. 500/7 or Gr.400/15 floats, float guide, seat ring of stainless steel 1.4436/1.4306, seat ring gasket of WRAS approved EPDM rubber (suitable for drinking water), internal fasteners of stainless steel A2. Body & Bonnet coated inside & outside with electrostatically applied epoxy powder coated blue colour (suitable for drinking water) as per DIN 30677-2 & GSK guidelines with a coating thickness of min. 250 microns. Flange connections as per IS 1538 raised face & pressure testing a manufactures works shall be done as per IS 14845. including transportation charges excluding GST levied by GOI & GOM in all respect etc. complete. (For PN 10 & 16)50 mm |
| 16 | PW 6-2) 150 mm dia Joint |
| 17 | 4) iv) 8.00 mm. |
| 18 | Manufacturing, providing and supplying spirally welded / ERW/ SAW / fabricated M. S. pipes (Commercial Quality) including procurements of plates, gas cutting to required size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming ‘V’ edge on both ends of pipes including railway freight, insurance, unloading from railway wagon, loading into truck, transport to stores, unloading, stacking, excluding GST levied by GOI & GOM in all respect etc. complete as per IS - 3589 and IS-5504 as applicable as per specifications (No negative tolerance in thickness is permissible). 1) 150 mm dia (ID) with 8 mm thick pipe |
| 19 | Lowering, laying in position to correct line and level including M. S. pipes with / without any outcoating on pedestals or chairs upon prepared formation. The rate to include loading, unloading, hoisting, marginal cutting wherever required, assembling and tack welding, and transportation upto 500 M. etc. completed as specified. 5 to 8 mm thick i)) Upto 250 mm. dia. |
| 20 | Welding in all positions with required number of runs, for M. S. pipes internally and / or externally including gauging wherever necessary, fixing appurtenances and other accessories in connection with pipe laying work as per specification. 8 mm. |
| 21 | Gas cutting (either square cut or V cut) pipes, plates, etc. of thickness. ii) Above 5 mm. Upto 10 mm. |
| 22 | Providing, fabricating, erecting, M.S. Flanges sleep on type (all tables) of required size and thickness with both side machined. PW 10-1) Up to 300 NB |
| 23 | Providing structural steel work in single stanchions composed of RSJ, channel, etc. with caps, bases, mild steel plates, angles, brackets, cleats, gusset plates, anchor bolts, etc. as per detailed design and drawing or as directed by Engineerin- charge including cutting, fabrication, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd- C-6/277) |
| 24 | Supplying, installing and testing earthing with galvanised iron earth plate size 60 x 60 x 0.6 cm complete with all accessories of GI materials & recording the results as per specification No. EA-EP |
| 25 | Supplying and erecting copper strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no EA-EP. |
| 26 | Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 27 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 28 | Providing, erecting, testing & commissioning of pumping machinery & allied accessories at pure water pumping station, WTP, Jambutake IA. |
| 29 | Providing, installing, testing & commissioning of Vertical turbine pump set suitable for discharging pure water at the rate of 50 Cum/hr at the duty point head of 23 mtr. and operating within the head range of 20 to 24 mtr at a speed of 1450 RPM with concrete foundation frame, CF8M impeller, CI casing suitable coupling with all allied material, cutting, welding & VHS SPDP induction motor, developing 7.5 KW i.e. 10 HP with \\"F\\" class insulation and thermostat protection embedded in stator winding, operating on 50 cycles, 415 volts complete with terminal box suitable for 3 core 6 sqmm, 1.1 KV PVC armored Aluminium cables for each pump motor set, etc complete as per specification. |
| 30 | Designing, manufacturing, testing and commissioning of L.T. switch board panel consisting of one incomer with 100 A MCCB with 100A 4P Changeover switch, 2 No. outgoing feeders for 2 No. of 10 HP star delta starter with main incomer 63A 3P MCCB & main contactor/ Delta contactor of 32 A AC3 & Star contactor 25A AC3 and Auxiliary outgoing feeder of 4 No. x 63A MCB, 4 No. x 32 A MCB with digital Ammeter/voltmeter/Phase sequence meter/MFM/LED indicating lamps/motor protection relay/push buttons, CTs, Copper bus- bars & control wiring, etc complete and panel to be out of 14 SWG CRCA sheet with powder coating & erected on necessary MS channels & angles frame work etc as per detailed specifications. |
| 31 | Designing, manufacturing testing and commissioning of L.T. switch board APFC panel having main incomer & outgoing of MCCB of suitable rating, Copper bus bar of suitable ratings with total 15 KVAR APFC set as per capacitor banks of various capacities 5 KVARx1, 3 KVARx2, 2KVARx2 along with 7% Aluminium reactor & heavy duty contactor for all steps etc. complete as per detailed specifications. |
| 32 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable, 1100 V 3 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 33 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 34 | Providing erecting Cast Steel/ Spheroidal Graphite (S.G) Iron D/F Sluice Valves / Butterfly Valves with jointing to pipe work (including all hardware and packing) water works quality, having non-rising spindle with hand wheel and without bypass arrangement, spindle of stainless steel as per requirement, inspection charges, transportation upto departmental store, unloading, stacking, excluding GST levied by GOI & GOM in all respect etc. excluding C. C. foundation / structural steel support. A) For Rating Class 150 (Working Pressure 20 kg/cm2 and Test Pressure 30 kg/cm2) a) Sluice Valves. CS-1503) 150 mm dia. |
| 35 | Providing erecting Cast Steel /Spheroidal Graphite (S.G.) Iron D/F Reflux Valves Single Door with jointing to pipe work (including all hardware and packing) water works quality with jointing to pipe without bypass arrangement, with gunmental seats including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. completed but excluding C. C. foundation / structural steel support.For Rating Class 150 (Working Pressure 20 kg/cm2 and Test Pressure 30 kg/cm2)a) Reflux valve CS-1503) 150 mm |
| 36 | Providing and supplying at site ductile iron / Spheroidal Graphite (S.G.) iron single / Double chamber tamper proof air valve without isolating sluice valve. Valves in accordance with BSEN 1074-4 of PN 10/16 rated, with body and bonnet of ductile iron confirming to EN 1563/IS 1865 Gr. 500/7 or Gr.400/15 floats, float guide, seat ring of stainless steel 1.4436/1.4306, seat ring gasket of WRAS approved EPDM rubber (suitable for drinking water), internal fasteners of stainless steel A2. Body & Bonnet coated inside & outside with electrostatically applied epoxy powder coated blue colour (suitable for drinking water) as per DIN 30677-2 & GSK guidelines with a coating thickness of min. 250 microns. Flange connections as per IS 1538 raised face & pressure testing a manufactures works shall be done as per IS 14845. including transportation charges excluding GST levied by GOI & GOM in all respect etc. complete. (For PN 10 & 16)50 mm |
| 37 | Providing, erecting and commissioning M.S. Dismantling joint as per requirement and Department‘s approved drawing and specifications, including machining and rubber rings and suitable for 16 kg/cm2 working pressure with required flanges of suitable size with nut bolts etc complete. The joint should have through long bolts so that during normal working pressure there should be no sliding movement of sliding flanges. L.O.F. ( length over flange ) should not be less than 75% of dia.PW 6-2) 150 mm dia Joint |
| 38 | Manufacturing, providing and supplying spirally welded / ERW/ SAW / fabricated M. S. pipes (Commercial Quality) including procurements of plates, gas cutting to required size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming ‘V’ edge on both ends of pipes including railway freight, insurance, unloading from railway wagon, loading into truck, transport to stores, unloading, stacking, excluding GST levied by GOI & GOM in all respect etc. complete as per IS - 3589 and IS-5504 as applicable as per specifications (No negative tolerance in thickness is permissible).Dia of Pipe : 200.00 mm (I. D.) Thickness of pipe :4) iv) 8.00 mm. |
| 39 | Manufacturing, providing and supplying spirally welded / ERW/ SAW / fabricated M. S. pipes (Commercial Quality) including procurements of plates, gas cutting to required size rolling, tack welding assembling in suitable lengths to form pipes, welding on automatic welding machine and forming ‘V’ edge on both ends of pipes including railway freight, insurance, unloading from railway wagon, loading into truck, transport to stores, unloading, stacking, excluding GST levied by GOI & GOM in all respect etc. complete as per IS - 3589 and IS-5504 as applicable as per specifications (No negative tolerance in thickness is permissible). 1) 150 mm dia (ID) with 8 mm thick pipe. |
| 40 | Lowering, laying in position to correct line and level including M. S. pipes with / without any outcoating on pedestals or chairs upon prepared formation. The rate to include loading, unloading, hoisting, marginal cutting wherever required, assembling and tack welding, and transportation upto 500 M. etc. completed as specified.5 mm to 8 mm thicki)) Upto 250 mm. dia. |
| 41 | Welding in all positions with required number of runs, for M. S. pipes internally and / or externally including gauging wherever necessary, fixing appurtenances and other accessories in connection with pipe laying work as per specification. 8 mm. |
| 42 | Gas cutting (either square cut or V cut) pipes, plates, etc. of thickness.ii) Above 5 mm. Upto 10 mm. |
| 43 | Providing, fabricating, erecting, M.S. Flanges sleep on type (all tables) of required size and thickness with both side machined. PW 10-1) Up to 300 NB |
| 44 | Providing structural steel work in single stanchions composed of RSJ, channel, etc. with caps, bases, mild steel plates, angles, brackets, cleats, gusset plates, anchor bolts, etc. as per detailed design and drawing or as directed by Engineerin- charge including cutting, fabrication, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd- C-6/277) |
| 45 | Supplying, installing and testing earthing with galvanised iron earth plate size 60 x 60 x 0.6 cm complete with all accessories of GI materials & recording the results as per specification No. EA-EP |
| 46 | Supplying and erecting copper strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no EA-EP. |
| 47 | Providing and laying in situ /Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 48 | Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. |
| 49 | Providing Internal & External Electrification of Plug & Play Sheds & Convention Centre. |
| 50 | Supplying and erecting shockproof 3 pin plug socket 6A with porcelain base/flush type erected on filled polypropylene board or polished thick varnished double wooden block / folded or screwed board with top of either wooden/ 3mm thick hylam sheet/ 4mm thick plywood pasted with 1.5mm thick laminate with S M screws and duly connected. |
| 51 | Supplying and erecting shockproof 3 pin plug socket 16A with porcelain base/ flush type erected on filled polypropylene board or polished thick varnished double wooden block / folded or screwed board with top of either wooden/3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5mm thick laminate with S M screws and duly connected. |
| 52 | Supplying and erecting shockproof Industrial 3 pin plug socket 32A with porcelain base/ flush type erected on filled polypropylene board or polished thick varnished double wooden block / folded or screwed board with top of either wooden/3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5mm thick laminate with S M screws and duly connected with inbuilt MCB |
| 53 | Supplying and erecting shockproof Industrial 3 pin plug socket 63A with porcelain base/ flush type erected on filled polypropylene board or polished thick varnished double wooden block / folded or screwed board with top of either wooden/3 mm thick hylam sheet/ 4mm thick plywood pasted with 1.5mm thick laminate with S M screws and duly connected with inbuilt MCB |
| 54 | Supplying and erecting CRCA powder coated light LED fitting (4 feet) Max. 33W with high transitivity diffuser with system lumens output of Min. 4000 lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 , IP20 rated including driver with end caps on provided PVC Block / wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 55 | Supplying and erecting anodized aluminium light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<20%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs at L70B50 including driver with end caps on provided PVC Block/wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 56 | Supplying and erecting CRCA powder coated down light LED fitting (4 feet) Max. 40W with high transitivity diffuser with system lumens output of Min. 6000 lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 , IP20 rated including driver with end caps on provided PVC Block / wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED with down pipe for hanging the light with necessary arrangement. |
| 57 | Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF. |
| 58 | Providing and erecting air circulator 600 mm. sweep oscillating type, wall mounting 1440 RPM without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 volts single phase, 50 cycles A.C. supply, core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation. |
| 59 | Supplying and erecting exhaust fan heavy duty 440 V A.C. 50 cycles 900 RPM 375/380 mm complete erected in position as per specification no. FG-FN/EXF |
| 60 | Providing and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 R.P.M. Oscillating type, plastic or metal blades chrome plated guard with regulator and moisture proof treatment to winding and with ‘E’ class insulation. |
| 61 | Supplying and erecting modular type (two module) electronic step regulator for fan, on provided plate and box with wiring connections complete. |
| 62 | Point wiring for independent plug in 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire,flush type switch, earthing and required accessories as per specification no. WG-PW/SW |
| 63 | Point wiring for light/fan/bell in 20 mm HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification no. WG-PW/SW |
| 64 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW |
| 65 | Supplying & erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW |
| 66 | Supplying & erecting HMS PVC conduit 20mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification no. WG-MA/CC. |
| 67 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 25 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 68 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 35 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 69 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 95 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 70 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel wire armoured (round) cable, 1100 V 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 71 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 72 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 73 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 50 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 74 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 70 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 75 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. |
| 76 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. |
| 77 | Supplying and erecting mini feeder pillar with 415V, 315-320A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket and enclosure must be dust proof, rust proof, vermin and water resistant, having slanting top and erected on angle iron/ GI frame in provided C.C. foundation complete as per specification no. SW-MFP. |
| 78 | Supplying, erecting & marking SP MCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 79 | Supplying, erecting & marking FP MCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 80 | Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB/TP MCB/FP MCB/RCCB/RCBO complete erected on provided angle iron/GI frame. |
| 81 | Supplying & erecting triple pole and neutral distribution board (TPNDB), 3 pole MCCB as incomer & outgoing SP MCB (24 poles) or TP MCB of 8 ways (24 poles), with door, 1.2mm thickness, surface/flush mounted, on provided iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB1 |
| 82 | Providing & erecting 3 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB |
| 83 | Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB |
| 84 | Providing & erecting 3 Pole MCCB, 415V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB |
| 85 | Supplying, erecting & commissioning 4 pole RCCB 100A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB. |
| 86 | Supplying, installing and testing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill ground ehancing compound complete with all accesories of copper materials & recording the results as per specification no EA-EP/EF |
| 87 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 88 | Supplying and erecting GI earth conductor of required sizes used for earthing or any other purposes on wall with necessary GI clamps fixed on wall/cable/ conduit with screws complete. |
| 89 | Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL. |
| 90 | Supplying and erecting integrated LED flood light fitting Max. 120W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min.14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 including driver with U shaped bracket with minimum 2 Years warranty as per specification No. FG-ODF/FL. |
| 91 | Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 92 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/BKT |
| 93 | Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaries and its control gear box, lightning arrestor, arrangement for fixing aviation light, night glow reflector on pole at suitable height, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with double check nuts & necessary accessories complete. specification no. OH-PL/HM |
| 94 | Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, 25 A TP contactor for automatic switching of luminaries, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete. |
| 95 | Making M-20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal/conical GI pole). |
| 96 | Making M-20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 2m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5m raising lowering high mast). |
| 97 | Supplying & erecting FRP box of size 150mm x 125mm x 100 mm, 2.7 mm thick complete on pole/wall as per specification No. CB-SB |
| 98 | Supplying and erecting street light Wall bracket made from 40 mm. dia ‘B’ class G.I. pipe 1.2 m in total length complete as per specification no. FG-BKT/WB. |
| 99 | Supplying and erecting Gate / garden light fitting with 200mm dia. glass bowl suitable for upto 12W LED Lamp on provided pipe as per specification No. FG-ODF/GLT. |
| 100 | Providing & erecting floor/wall mounting, MCCB panel board, with door, suitable for 4 pole incoming 250A, 8 ways 4 pole outgoing, up to 100A MCCBs on iron frame, as per specification no SW-MCCBPB. (Excluding MCCBs) |
| 101 | Providing surge arrester system at Jackwell, Jambutake. |
| 102 | Providing, Erecting, Water Surge Arrestor Protection system suitable for Line Pressure Including Designing of Bladder Vessel of capacity 1 Cum, Pressure rating 20 Kg/cm2 and Control Panel and all Accessories Suitable for 7 MLD with One Air Valve as per analysis and all type of Civil Work for Bladder Vessel etc complete. |
| 103 | Providing internal & external electrification to Jackwell & WTP at Jambutake. |
| 104 | Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm FRLSH grade copper wire, flush type switch,earthing and required accessories as per specification no. WG-PW/SW |
| 105 | Point wiring for light/bell/exhaust fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW |
| 106 | Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthing and required accessories as per specification no. WG-PW/SW |
| 107 | Supplying and erecting modular type 3 pin 6/16A multi socket with safety shutter on provided plate and box with wiring connections complete. |
| 108 | Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module complete. |
| 109 | Supplying and erecting modular type switch 16A on provided plate and box with wiring connections complete. |
| 110 | Supplying & erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW |
| 111 | Supplying & erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places. as per specification no. WG-MA/BW |
| 112 | Supplying, erecting & marking SP MCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 113 | Supplying, erecting & marking DP MCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 114 | Supplying, erecting & marking DP MCB 40A to 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB |
| 115 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 4 ways/phase (12 poles), with door, 1.2mm thickness, surface/flush mounted, IP 43 protection on provided iron/GI frame (horizontal busbar type) as per specification no. SW-MCBDB. |
| 116 | Supplying & erecting triple pole and neutral distribution board (TPNDB), SPMCB of 12 ways/phase (36 poles), with door, 1.2mm thickness surface/flush mounted, IP 43 Protection provided on iron/GI frame (horizontal busbar type) as per specification no. SW-MCBDB. |
| 117 | Supplying and erecting CRCA powder coated light LED fitting (4 feet) Max. 33W with high transitivity diffuser with system lumens output of Min. 4000 lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 4 kV, Life class of 50,000 Hrs at L70B50 , IP20 rated including driver with end caps on provided PVC Block / wooded board with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 118 | Supplying and erecting integrated LED Highbay Fitting 100W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics, having system lumens output of Min. 15000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs at L50B50 , including driver complete with 2 Year warranty as per specification No. FG-ODF/LED. |
| 119 | Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC. |
| 120 | Supplying and erecting regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF. |
| 121 | Providing and erecting air circulator 450 mm. sweep oscillating type, wall mounting 1440 RPM without speed regulator, overheat protection unit, totally enclosed, flame proof motor suitable for230/250 Volts single phase, 50 cycles A.C. supply, with one metre of 3core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation. |
| 122 | Supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM without speed regulator, metallic blades, overheat protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 metre length and hand shield type 3 pin6A. plug top complete with moisture proof treatment and ‘E’ class insulation. |
| 123 | Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF |
| 124 | Supplying and erecting copper strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint with joints required as per specification no EA-EP. |
| 125 | Supply, installing, and testing of maintenance free earthing comprising of electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity (min. 125kg) complete, and recording the results specification no. EA-MF |
| 126 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 127 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 128 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 50 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU |
| 129 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. |
| 130 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. |
| 131 | Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 132 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/BKT |
| 133 | Making M-20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal/conical GI pole). |
| 134 | Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL. |
| 135 | Supplying and erecting integrated LED street light fitting 85-90W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 9300 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL. |
| 136 | Supplying & erecting street light control panel outdoor type, for three phase 4 wire system having in built astronomical adjustable programmable timer with minimum 5 years battery back up, having IP54, IK10 protection, 4 pole contactor upto 60A, with maintenance mode to switch ON street lights during time of repairs with energy consumption data recording for analysis and LCD display for energy monitoring with numeric keypad in provided box as per specification SW-STCP. |
| 137 | Making bore of 3 to 4 \\" diameter along with casing and capping PVC/DWC pipe for laying cable at road crossing by horizontal boring machine including all materials, labour, excavation and refilling of excavated material etc complete in an approved manner as per instructions of engineer-in-charge |
| 138 | Supplying, Erecting, Testing and Commissioning Generation III / Commissioning Advance Early Streamer Emission (ESE) Protector Lighting Arrestor having following features and controls Mounted at a height of 5 mtr above top terrace level giving level - I protection having 79 mtr radius protection (RP ) complete. Polarized the tip with 20 to 30 KV with the progress of descending tracer and of triggering of an anticipated at star of the Ascending Tracer, remotely testing facility via radio signals with on board Transmitter using standard frequency and transmitting at every 45 seconds to confirm the correct operation of Lightning Conductors Electronics including polarization of tip. 304 L grade stainless steel outer body and tip, Electronic components are protected in inert resin block. The spark gap is made up of solid stainless steel is designed to carry currents of 180 KA, Powered by 6 Volt maintenance free Battery (fixed into LA nside LA) as per drawing charged by 3 indestructible flexible solar cells (fixed on body on LA) charged continuously as per drawing, The faces of each cellared madeborn EthelTetra charged continuously as per drawing, The faces of each cell are made born Ethel Tetra Fluro thylene ( ET’FE ) polymer material, The ESE air terminal is an intelligent device able to synchronies with downward lightning and adopt tothe --- ve and + ve lightning quality ( M/s. Duval Messien of France make having Satelit 3 - 60 model) (Rates excluding GST) Advance early Streamer Emission (ESE) Protector Lighting Arrestor having following features and controls Mounted at a height of 5 mtr above top terrace level giving level - I protection having 79 mtr radius protection (RP ) complete. Polarized the tip with 20 to 30 KV with the progress of descending tracer and of triggering of an anticipated at star of the Ascending Tracer, remotely testing facility via radio signals with on board Transmitter using standard frequency and transmitting at every 45 seconds to confirm the correct operation of Lightning Conductors Electronics including polarization of tip. 304 L grade stainless steel outer body and tip, Electronic components are protected in inert resin block. The spark gap is made up of solid stainless steel is designed to carry currents of 180 KA, Powered by 6 Volt maintenance free Battery (fixed into LA inside LA) as per drawing charged by 3 indestructible flexible solar cells (fixed on body on LA) charged continuously as per drawing, The faces of each cell are made born Ethel Tetra Fluro Ethylene ( ET’FE ) polymer material, The ESE air terminal is an intelligent device able to synchronies with downward lightning and adopt to the --- ve and + ve lightning quality ( M/s. Duval Messiaen of France make having Satellite 3 - 60 model) (Rates excluding GST) |
| 139 | Supplying and Erecting supporting mast of4.5 mtrs. height made up of SS 304 L material for pole structure having 4.5 Mtr. Height com plete with SS base plate of size 250 x 250 mm & 18 mm thick and required civil work and stay supports with wire ropes having 8 / 19 constnioion with suitable insulator etc. (NDSR) (Rates excluding GST) |
| 140 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminus pain in an approved manner with joints required as per specification no EA-EP. |
| 141 | Supplying and Erecting Test Joint ( Test Clamps ) mounted in between the Earth Electrode ( EC ) and Down Conductor ( DC) at the height of 2 meter above ground level to be done as pet referent IS specifications designed and situated so as the resistance of Earth Electrode can be made. (NDSR) (Rates excluding GST) |
| 142 | Supplying and erecting Electromechanical Lighting Strike counter having following features :- i) Counts lightning strikes with 6 digit count display ii) Easy to monitor and install iii) No maintenance required iv) It should count flashes up to 100 kA, v) mounted with monitor and install iii) No maintenance required iv) It should count flashes up to 100 kA, v) mounted with lighting protection system, vi) It should be IP 65 tested. Vii)Easy to monitor & install viii) No maintenance ix) • It should be tested by CPRI (NDSR ) |
| 143 | Supplying and erecting, testing typical earth pit with TEREC + Maintenance Free Earthing compound 3 bags each of 5 kg. in weight as per specifications (each down conductor requires 3 earth pits and each pit require 2 bags of earthing compound of 5 kg ) Rod Electrode - 1.2 tneter 14.2 mm dat. 250 microne copper bonded rod of 2 nos and rod to caple clamp ( NDSR ) (Rates excluding GST) |
| 144 | Providing HDPE chamber for earth pits complete. (Rates excluding GST) |
| 145 | Supplying and testing Remote Tele tester for Generation IK08 ESE Protection Lightning Arrestor as per NFC 17 - 102 standards with guarantee for one year having following features and controls : Operating on standard frequency of 433 MHZ in radio frequency band complying with ETS 3000220 and ETS 300683 with one 9 volts battery of PP 3 type, The Tele tester TESTS3N, receives the information transmitted by Satellite - 3 at every 45 seconds and emits the audio signals continuing that ( the installation is fully functional, seconds and emits the audio signals continuing that( the installation is fully functional, The check can be performed at a distance of 50 meters between Satellite - 3 and Remote Teletester S - 3. ,ABS IP54 + polycarbonate keyboard outer body having dimensions of L 130 mm X l 65 mm X h 25 mm. size IP 54 Protection class. (Mls. Duval Messien of France make having TeleTester TESTS3Nmodel) (Rates excluding ST) |
| 146 | Providing EOT cranes at raw & pure water pumping stations at Wagad dam & Jambutake |
| 147 | Design and fabrication of 3 Ton. Capacity Single Girder EOT Crane With accessories as per technical details given as per above page. VFD Drive will be for LT motion only. Excluding traveling ISBM |
| 148 | Erection & Commissioning of the above crane at local site and giving satisfactorily testing and trials complete using all safety equipments, hooks / hoist etc complete. |
| 149 | Providing, erecting and fixing square bar of EN 8 as rail for over head crane on provided track, girder / continuous corbel beam, including supporting plate and \\"J\\" bolts.LF 5 -1) 50 X 50 mm ( EN 8) |
| 150 | Providing structural steel work in single stanchions composed of RSJ, channel, etc. with caps, bases, mild steel plates, angles, brackets, cleats, gusset plates, anchor bolts, etc. as per detailed design and drawing or as directed by Engineerin- charge including cutting, fabrication, hoisting, erecting, fixing in position, making riveted / bolted / welded connections and one coat of anticorrosive paint and over it two coats of oil painting, etc. complete. (Bd- C-6/277) |
| 151 | Providing power supply arrangement for raw/pure water pumping stations & WTP at Wagad dam & Jambutake. |
| 152 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means |
| 153 | Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift upto 1.5 m). By Mechanical Means |
| 154 | Providing and laying Cast in situ/Ready Mixcement concrete in M20 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 155 | Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ |
| 156 | Supplying and erecting V cross arm with ISM channel of 75x40x6mm for 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts, washers complete as per specification no. OH-PL/VCA |
| 157 | Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV, 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA |
| 158 | Supplying and erecting bracket for guarding of HT OH Line, made from channel iron 1600mm in length and 75x40x6mm. erected on pole complete as per specification no. OH-PL/VCA |
| 159 | Supplying & erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing. |
| 160 | Supplying & erecting inline D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 300 Amps as incomer & 6 Nos. 100 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos of Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete. |
| 161 | Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI |
| 162 | Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete as per specification no. OH-INS/PN |
| 163 | Supplying & erecting strain hardware for 100 sqmm AAAC conductor in an approved manner |
| 164 | Supplying & erecting AAAC conductor - 100 sqmm in an approved manner |
| 165 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 240 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 166 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 70 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 167 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 120 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 168 | Providing and erecting danger board on HT line pole with proper building, etc. complete |
| 169 | Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. |
| 170 | Supplying and fixing MS base plate 30x30x0.6cm size fixed to the pole base either by welding 12mm dia fixed at position. |
| 171 | Supplying and erecting 11 kV outdoor type gang operated air break, triple pole switch 400 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of \\"C\\" class G.I. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp. |
| 172 | Supplying and erecting anti climbing devices, fabricated from pole clamps of MS flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erected on pole complete. |
| 173 | Supplying and erecting GI earth conductor of required sizes used for earthing or any other purposes on wall with necessary GI clamps fixed on wall/cable/ conduit with screws complete. |
| 174 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required as per specification no EA-EP. |
| 175 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 176 | Supplying, installing and testing earthing with galvanised iron earth plate size 60 x 60 x 0.6 cm complete with all accessories of GI materials & recording the results as per specification No. EA-EP |
| 177 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, aluminium wound Non-sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 45? by thermometer in oil and 50 ? by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL. |
| 178 | Supplying & erecting DTC metering box for 200 KVA transformer with single core resin cast CTs and other relevent materals as per MSEDCL requirement in an approved manner. |
| 179 | Supplying & erecting Wedge connector suitable for AAAC-100 Sq.mm in an approved manner. |
| 180 | Supplying & erecting Sleev joint suitable for AAAC -100 sqmm conductor in an approved manner. |
| 181 | Providing street light poles along internal roads in Jambutake IA |
| 182 | Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL |
| 183 | Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/BKT |
| 184 | Making M-20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal/conical GI pole). |
| 185 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 186 | Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FG-ODF/SL. |
| 187 | Supplying & erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/bus bars or any other places as per specification no. WG-MA/BW |
| 188 | Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. |
| 189 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 190 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 191 | Supplying & erecting three phase, 415V, street light control panel upto the max load of 12kW, TPN MCB 63A, powder coated CRCA 14 SWG sheet, outdoor type, having IP54, IK10 protection suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation with overcurrent, short circuit, earth fault protection on provided iron frame / CC foundation as per specification SW-STCP. |
| 192 | Making bore of 3 to 4 \\" diameter along with casing PVC/DWC pipe for laying cable at road crossing by horizontal boring machine including all materials, labour, excavation and refilling of excavated material etc complete in an approved manner as per instructions of engineer-in-charge. |
| 193 | Shifting of 33 KV, 11 KV & LT lines in Jambutake Indl Area. |
| 194 | A) Shifting of 33 KV HT lines with 100 sqmm AAAC conductor on 152X152 mm, 13 mtr. RSJ poles in Jambutake Indl. AreaSupplying and erecting rolled steel joist (girder) pole 152 x 152 mm (37.1 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ |
| 195 | Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. |
| 196 | Supplying and fixing MS base plate 30x30x0.6cm size fixed to the pole base either by welding 12mm dia fixed at position. |
| 197 | Making Cement concrete foundation including excavation (60 x 60)cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45cm x 45cm x 45cm/ 45cm dia. x 45cm height plinth duly plastered, with necessary curing and finishing complete. (for above 9m poles) |
| 198 | Making Cement concrete foundation including excavation (60 x 60 x 150)cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay). |
| 199 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose) |
| 200 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 201 | Supplying and erecting GI earth conductor of required sizes used for earthing or any other purposes on wall with necessary GI clamps fixed on wall/cable/ conduit with screws complete. |
| 202 | Supplying and erecting V cross arm with ISM channel of 100x50x6mm or 22/33kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1530mm bent at angle of 60 degree keeping base 310mm and the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts, washers complete as per specification no. OH-PL/VCA |
| 203 | Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV, 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA |
| 204 | Supplying and erecting bracket for guarding of HT OH Line, made from channel iron 1600mm in length and 75x40x6mm. erected on pole complete as per specification no. OH-PL/VCA |
| 205 | Supplying & erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing. |
| 206 | Supplying and erecting polymer pin type insulator with GI pin suitable for 33kV line, complete as per specification no. OH-INS/PN |
| 207 | Supplying and erecting polymer disc type insulator 70KN with necessary hardware suitable for 33kV line complete as per specification no. OH-INS/DI |
| 208 | Supplying & erecting AAAC conductor - 100 sqmm in an approved manner. |
| 209 | Supplying & erecting strain hardware for 100 sqmm conductor in an approved. |
| 210 | Supplying & erecting Sleeve joint suitable for AAAC - 100 sqmm conductor in an approved manner. |
| 211 | Supplying & erecting Wedge connector suitable for AAAC100 sqmm conductor in an approved manner. |
| 212 | Providing & erecting Danger board on HT line pole with GI wire binding, etc. complete in an approved manner. |
| 213 | Supplying and erecting, 33 kV outdoor type drop out fuse with insulator complete with fuse holders, fuse barrel with metal fitting, fuse element mounted on M.S. channel with working current of 15A capacity complete erected on provided cross arm. |
| 214 | Supplying and erecting anti climbing devices, fabricated from pole clamps of MS flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erected on pole complete. |
| 215 | Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. |
| 216 | Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes. |
| 217 | B) Shifting of 11 KV HT lines with 100 sqmm AAAC conductor on 152X152 mm, 11 mtr. RSJ poles in Jambutake Indl. Area.Supplying and erecting rolled steel joist (girder) pole 152 x 152 mm (37.1 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ |
| 218 | Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. |
| 219 | Supplying and fixing MS base plate 30x30x0.6cm size fixed to the pole base either by welding 12mm dia fixed at position |
| 220 | Making Cement concrete foundation including excavation (60 x 60)cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25 mm stone metal, 45cm x 45cm x 45cm / 45cm dia. x 45cm height plinth duly plastered, with necessary curing and finishing complete. (for above 9m poles) |
| 221 | Making Cement concrete foundation including excavation (60 x 60 x 150)cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete. (for stay). |
| 222 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose) |
| 223 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 224 | Supplying and erecting GI earth conductor of required sizes used for earthing or any other purposes on wall with necessary GI clamps fixed on wall/cable/ conduit with screws complete. |
| 225 | Supplying and erecting V cross arm with ISM channel of 75x40x6mm for 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts, washers complete as per specification no. OH-PL/VCA |
| 226 | Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV, 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA |
| 227 | Supplying and erecting bracket for guarding of HT OH Line, made from channel iron 1600mm in length and 75x40x6mm. erected on pole complete as per specification no. OH-PL/VCA |
| 228 | Supplying & erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing. |
| 229 | Supplying and erecting polymer pin type insulator with GI pin suitable for 11kV line, complete as per specification no. OH-INS/PN |
| 230 | Supplying and erecting polymer disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI |
| 231 | Supplying & erecting AAAC conductor -100 sqmm in an approved manner. |
| 232 | Supplying & erecting strain hardware for 100 sqmm AAAC conductor in an approved manner. |
| 233 | Supplying & erecting Sleeve joint suitable for AAAC -100 sqmm conductor in an approved manner. |
| 234 | Supplying & erecting Wedge connector suitable for AAAC -100 sqmm conductor in an approved manner. |
| 235 | Providing & erecting danger board on HT line pole with proper GI wire binding, etc. complete. |
| 236 | Supplying and erecting kV outdoor type gang operated air break, triple pole switch 400 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of \\"C\\" class G.I. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp. |
| 237 | Supplying and erecting anti climbing devices, fabricated from pole clamps of MS flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erected on pole complete. |
| 238 | Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. |
| 239 | Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes. |
| 240 | C) Shifting of LT lines on 125X70 mm, 9 mtr. RSJ poles in Jambutake Indl. Area.Supplying and erecting rolled steel joist (girder) pole 125 x 70 mm (13.3 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ |
| 241 | Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. |
| 242 | Supplying and fixing MS base plate 30x30x0.6cm size fixed to the pole base either by welding 12mm dia fixed at position. |
| 243 | Supplying and erecting fibre/PVC spacers for LT overhead line 3 to 5 conductors complete erected. |
| 244 | Making Cement concrete foundation including excavation (60 x 60 x 150)cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45)cm /45cm dia. x 45cm height plinth duly plastered, with necessary curing and finishing complete. (above 6m to 9m poles) |
| 245 | Making Cement concrete foundation including excavation (60 x 60 x 150)cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete. (for stay). |
| 246 | Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose) |
| 247 | Supplying & erecting MS pole bracket for LT OH conductor fabricated from 65x65x6 mm section, 1100mm long for necessary nos. of provided insulators and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT |
| 248 | Supplying and erecting porcelain shackle type LT medium insulator 75x115mm dia. with G.l. (shackle) strips, nuts and bolts, complete. |
| 249 | Supplying and erecting aluminum bobbin with G.l. (shackle) strip, nuts complete. |
| 250 | Supplying and erecting all aluminum stranded conductors 7/2.21 mm. complete. (Gnat) (73.77kg/km) as per specification No. OH-CON/AAC |
| 251 | Supplying and erecting all aluminium stranded conductors 7/3.10 mm. complete. (Ant.) (145.0 kg/km) as per specification No. OH-CON/AAC |
| 252 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 253 | Supplying and erecting GI earth conductor of required sizes used for earthing or any other purposes on wall with necessary GI clamps fixed on wall/cable/ conduit with screws complete. |
| 254 | Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the c.c. foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level. |
| 255 | Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes. |
| 256 | Supplying & erecting Wedge connector for Ant & Gnat conductors in an approved manner. |
| 257 | Providing power supply arrangement with 11 KV HT & LT network with 200 KVA DTC & 11 KV express feeder and allied works in Jambutake Indl Area. |
| 258 | Supplying and erecting rolled steel joist (girder) pole 100 x 116 mm (23 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ |
| 259 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 0.00 to 1.50 m.) By Manual Means |
| 260 | Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means |
| 261 | Providing and laying Cast in situ/Ready Mixcement concrete in M20 of trap/ granite/quartzite/gneiss metal for steps including steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface, only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand VSI Grade) |
| 262 | Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete. |
| 263 | Supplying and fixing MS base plate 30x30x0.6cm size fixed to the pole base either by welding 12mm dia fixed at position. |
| 264 | Supplying, installing and testing earthing with galvanised iron earth plate size 60 x 60 x 0.6 cm complete with all accessories of GI materials & recording the results as per specification No. EA-EP |
| 265 | Supplying, installing and testing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.I. Rod complete with all accessories of GI materials & recording the results as per specification no. EA-EP |
| 266 | Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required as per specification no EA-EP. |
| 267 | Supplying and erecting GI earth conductor of required sizes used for earthing or any other purposes on wall with necessary GI clamps fixed on wall/cable/ conduit with screws complete. |
| 268 | Supplying and erecting V cross arm with ISM channel of 75x40x6mm for 11kV HT OH line with arrangement to fix insulator at 45mm from the end & horizontal distance between insulators 1220mm bent at angle of 60 degree keeping base 305mm and the total vertical height of V cross arm as 460mm, and fixed on pole with MS clamp of 80x10 mm, nut bolts, washers complete as per specification no. OH-PL/VCA |
| 269 | Supplying and erecting 75x40 x6mm with 4.4mm thick web and 7.3mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065mm for 11kV, 1320mm for 22kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA |
| 270 | Supplying and erecting bracket for guarding of HT OH Line, made from channel iron 1600mm in length and 75x40x6mm. erected on pole complete as per specification no. OH-PL/VCA |
| 271 | Supplying & erecting single pole cut point channel set of for 11kV HT OH line two channel of size 100x50x6mm 1.6m long having stud angle of size 50x50x6mm 1.5m long with necessary clamps, nut bolts etc. complete as per drawing. |
| 272 | Supplying & erecting inline D. P. Structure for 11/0.415 kV, 200 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 300 Amps as incomer & 12 Nos. 100 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos of Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire. D.P. Structure shall be erected in c.c. foundation complete. |
| 273 | Supplying and erecting porcelain disc type insulator 45KN with necessary hardware suitable for 11kV line, complete as per specification no. OH-INS/DI |
| 274 | Supplying and erecting porcelain pin type insulator with GI pin suitable for 11kV line, complete as per specification no. OH-INS/PN |
| 275 | Supplying & erecting AAAC conductor - 100 sqmm in an approved manner. |
| 276 | Supplying & erecting strain hardware for 100 sqmm AAAC conductor in an approved manner |
| 277 | Supplying & erecting Sleeve joint suitable for AAAC -100 sqmm conductor in an approved manner. |
| 278 | Supplying & erecting Wedge connector suitable for AAAC -100 sqmm in an approved manner. |
| 279 | Providing and erecting danger board on HT line pole with proper building, etc. complete. |
| 280 | Supplying and erecting 11 kV outdoor type gang operated air break, triple pole switch 400 A capacity with 3 post pin type insulator per phase, mounted in horizontal or vertical position with necessary channels on provided cross arm with adequate length of \\"C\\" class G.I. pipe for operating handle erected on extended square shaft. The operating handle provided with lock and key at suitable height from ground level with necessary clamp. |
| 281 | Supplying and erecting anti climbing devices, fabricated from pole clamps of MS flat 40x5 mm, with drooping spikes 15 cm. in length, welded to it and erected on pole complete. |
| 282 | Supplying, installing, testing & commissioning 3 phase, 11/0.433 kV, 50 Hz., 200 kVA, Mineral oil immersed and naturally cooled outdoor type, Aluminium wound Non-sealed transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40? by thermometer in oil and 45? by the resistance method in winding at full load rating, using type A winding insulation (kraft paper) with HV tapping (with off load tap changer)off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 780 Watts at 50% load, 2300 Watts at 100% load as per IS:1180 (part 1) : 2014 , with necessary permissions of Electrical Inspector, as per specification no SS-TR-NSL. |
| 283 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 185 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 284 | Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable, 1100 V 3½ core 240 sq. mm. aluminium conductor complete erected with glands & lugs on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL |
| 285 | Supplying & erecting single compression type brass cable glands for 3½ core 185 sq mm cable as per specification No. CB-GL |
| 286 | Supplying & erecting Single Compression type brass cable glands for 3½core 240 sq mm cable as per specification No. CB-GL |
| 287 | Supplying & erecting crimping type aluminium lugs for cable 185 sq mm complete as per specification No. CB-CL/AL |
| 288 | Supplying & erecting crimping type aluminium lugs for cable 240 sq mm complete as per specification No. CB-CL/AL |
| 289 | Supplying & laying (including excavation) half round reinforced cement concrete pipe of NP-2 class of 250 mm diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete. |
| 290 | Providing, erecting, testing & commissioning of LT feeder pillar 4 way with 200 A FP MCCB as incomer and 4 out going circuits with HRC fuse base and cartridge (12 No.) consists of aluminium bas bars 500 V/300 A complete erected 14 SWG CRCA sheet box with supporting angles, self locks, gasket and slanting top to be erected on provided foundation as per specification etc complete in an approved manner. |
| 291 | Supplying & erecting DTC metering box for 200 KVA transformer with single core resin cast CTs and other relevant materials as per MSEDCL requirement in an approved manner. |
| 292 | Supplying , erecting & terminating XLPE insulated, galvanised steel formed round wire armoured (strip) cable 11 kV(E), 3 x 300 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT |
| 293 | Providing and erecting Heat shrinkable outdoor termination kit for 11 KV (E) XLPE HT cable 3x240 to 300 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 294 | Providing and erecting Heat shrinkable straight through joint kit for 11 KV (E) XLPE HT cable 3x240 to 400 sq. mm. with necessary material as per specification no. CB-JT/HT |
| 295 | Supplying and erecting G.I. pipe ‘C’ class ERW 150 mm dia with necessary fittings duly painted with two coats of synthetic enamel paint of fire red colour over a coat of primer (ISC code 536 as per IS 2932 of 2003) complete as per specification no. FF-PP |
| 296 | Making Horizontal Directional Drill / Bore of 150 mm dia and depth up to 1.5 mtr in soft soil and laying 150 mm HDPE/GI pipe etc. complete. |
| 297 | Providing. installing, testing and commissioning of full bore electromagnetic flow meters on raw & pure water rising mains at WTP Jackwell, Waghad dam. |
| 298 | Providing, installing, testing & Commissioning of Full Bore Electromagnetic flow meter size 200 mm for raw water rising pipe line including witness testing at manufacturer works, pressure transmitter 0-15 bar, weather proof panel Cabinet, Remote Terminal Unit with Online Data Acquisition system, SCADA System, Shain V flow 100, PVC armoured copper cable 4 core x 4 sqmm, HDEP pipe for cable laying, Dismantling joint, MS pipes/specials, chamber with all required materials & labours for erection and commissioning of flowmeter, etc complete |
| 299 | Providing, installing, testing & Commissioning of Full Bore Electromagnetic flow meter size 200 mm for raw water rising pipe line including witness testing at manufacturer works, pressure transmitter 0-15 bar, weather proof panel Cabinet, Remote Terminal Unit with Online Data Acquisition system, SCADA System, Shain V flow 100, PVC armoured copper cable 4 core x 4 sqmm, HDEP pipe for cable laying, Dismantling joint, MS pipes/specials, chamber with all required materials & labours for erection and commissioning of flowmeter, etc complete |
| 300 | Cat (B) - Buy Back Items |
| 301 | Rebate against old dismantled materials such as MS poles, brackets, conductors, etc. |
| 302 | Rebate against old dismantled materials such as MS poles, brackets, conductors, etc. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 24 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender