Tender For Construction And Commissioning Of 02 No. 132Kv Gis Feeder Bay (Outdoor) (For 132Kv Sahjanwa Tss) At 220Kv Substation Dulhipar, Sant Kabir Nagar
Tender Value
11.49 Crore
Estimated cost
Bid Submission
22 Sep 2026
4 days left
EMD
11.49 Lakhs
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Construction And Commissioning Of 02 No. 132Kv Gis Feeder Bay (Outdoor) (For 132Kv Sahjanwa Tss) At 220Kv Substation Dulhipar, Sant Kabir Nagar
BOQ
| Sl. No. | Item Description |
| 1 | Tender Inviting Authority: Superintending Engineer, Electricity Substation Design Circle -I, U.P. Power Transmission Corporation Limited, 13th Floor, Shakti Bhawan Extension, 14-Ashok Marg, Lucknow-226001 Name of Work: Construction and commissioning of 02 no. 132kV GIS Feeder Bay (Outdoor) (For 132kV Sahjanwa TSS) at 220kV substation Dulhipar, Sant Kabir Nagar Tender Specification No. : SD-1046 Bidder Name : SCHEDULE- 5 (SUMMARY OF PRICE SCHEDULES) Sl. No. Description Amount (Rs.) |
| 2 | Total Prices of supply of equipments & materials (Schedule-1) |
| 3 | Total Prices of Handling, Erection, Testing & Commissioning Charges (Schedule-2) |
| 4 | Total Prices of supply of mandatory spares (Schedule-3) |
| 5 | Total Prices of civil works (Schedule-4) |
| 6 | Total Prices (1+2+3+4) |
| 7 | GST @ 18% |
| 8 | Total Prices including 18% GST (5+6) Place: Signature Name: Designation: Common Seal: Marked cell are required to filled by the bidders Tender Inviting Authority: Superintending Engineer, Electricity Substation Design Circle - I, U.P. Power Transmission Corporation Limited, 13th Floor, Shakti Bhawan Extension, 14-Ashok Marg, Lucknow-226001 Name of Work: Construction and commissioning of 02 no. 132kV GIS Feeder Bay (Outdoor) (For 132kV Sahjanwa TSS) at 220kV substation Dulhipar, Sant Kabir Nagar Tender Specification No. : SD-1046 Bidder Name : SCHEDULE- 1 (SCHEDULE OF QUANTITIES AND PRICES SUPPLY OF EQUIPMENT & MATERIALS) ( All Prices are in Rupees ) Sl. No. EQUIPMENT / ITEM(Complete with all fittings, accessories, associated equipments etc. as specified in Technical Specifications) Unit Quantity Quoted Unit prices in Rs. (Exclusive of GST) Total FOR Destination Prices without GST (4x8) Unit Ex-Works Prices Unit Pkg, Fwdg, Charges Unit Freight &Insurance charges Total unit rate without GST (5+6+7) |
| 9 | Line Feeder Bay Module as per 220 KV S/S IS Comprising of circuit breaker, CTs & PTs, disconnectors, grounding switch, line disconnector, cable termination enclosure and local control cubicle. |
| 10 | 145kV, 1600A, 40KA for 3 sec SF6 gas insulated outdoor feeder bay module each comprising of SF6 gas insulated circuit breaker(1600A), current transformer (800/400/200/1-1-1A), bus-bar disconnectors with common grounding switch, line disconnector with one normal safety grounding switch, & one high speed fault make grounding switch, Local Control Cubicle, PT, SF6 gas monitoring system for complete bay. Three 1–phase SF6 ducts and gas insulated terminal connection for connecting 3 nos of single phase 630sq.mm XLPE cable with cable termination enclosure etc. and accessories to complete feeder bay module as per technical specification. |
| 11 | 120 KV Polymer Type Surge Arrestors (Short Circuit Rating 40 KA for 3 sec) |
| 12 | 132kV Line C&R panel (SAS based) |
| 13 | 132kV Bus Bar Protection Panel (Centralised) |
| 14 | 145kV Potential Transformer |
| 15 | 132kV Line Isolator as per TS |
| 16 | 145KV, 6KN Polymer Bus Post Insulator |
| 17 | 0.2s accuracy class ABT Energy Meter |
| 18 | Metering cubicle for ABT energy meters |
| 19 | Supply and Installation in complete respect of 2 Ton Split AC 5 star (O General, Hitachi, Daikin make ) along with 5 KVA V Guard or equivalent make stabilizers, stands, drain pipes etc including all labour and T&P and all related works as requiredalong with proper installation and running of the system complete in all respects. |
| 20 | 1.1kV Grade PVC Copper conductor armoured control cables alongwith lugs, glands etc. a 2Cx2.5 sq.mm km 2.0 b 4Cx2.5 sq.mm km 6.0 c 4Cx4 sq.mm km 2.0 d 6Cx4 sq.mm km 5.0 e 10Cx2.5 sq.mm km 3.0 f 14Cx2.5 sq.mm km 1.0 |
| 21 | 1.1kV Grade PVC Aluminium conductor armoured power cables alongwith lugs, glands etc. a 2Cx6 sq.mm km 1.0 b 4Cx16 sq.mm km 1.0 |
| 22 | HT Cable a 145kV. 1-Core. 630sq.mm. XLPE copper cable for 132kV GIS as per Technical specification Mtr. 800.0 b 145 kV Termination Kit at both ends for I x 630 sq mm XLPE copper cable(one end is GIS type and other end is AIS type) Set 12.0 c Single core, 3.3kv 300 sqmm Sheath bonding coaxial cable mtr. 50.0 d Single core, 500 sqmm Copper conductor PVC insulated 3.3 kv grade earthing cable mtr. 400.0 e Single phase link box with/without SVL as required Nos. 4.0 f Three phase link box with/without SVL as required Nos. 2.0 g HDPE Pipe suitable for above XLPE Cable mtr. 30.0 h Aluminium alloy single clamps Nos. 24.0 i Aluminium alloy trefoil clamps Nos. 200.0 j Terminal Connector as required Nos. 4.0 |
| 23 | Main & Aux Structures with MS angles, channels, plates, nuts, bolts, step bolts, U bolts, spring washers, etc., and any other required material a ERW Pipe Structure MT 1.5 b Steel Structure including lattice structure & nut bolts MT 10.0 c ACSR Panther Conductor km 2.0 d 70 KN Anti fog Disc Insulators Nos. 100.0 e Single Suspension Fittings Suitable for ACSR Panther Nos. 10.0 f PG clamps suitable for panther/panther Nos. 16.0 g Bus Post Clamps suitable for panther Nos. 8.0 h 50x6 mm MS Flat for cable trench/panel earthing etc. Mtr. 400.0 i 25x6 mm MS Flat RM 100.0 j 75X12 mm MS Flat for cable trench/panel earthing etc. Mtr. 200.0 k 75x12mm Copper Flat( For GIS switchgear Screening. Shielding and earthing) Mtr. 50.0 l 40mm MS rod for Main Earthmat Mtr. 200.0 m 40mm día MS Electrodes (3 M Long) Nos. 8.0 |
| 24 | Earthing Material Total Note : 1- Any material not specifically mentioned in the above schedule but required for the proper and complete execution of the work shall be deemed to be included in the scope of supply. 2- Bidder is required to quote prices in this Schedule for all the individual items/sub-items. 3- Please confirm that the prices are after taking into account ITC benefits. As per section 171 of CGST act 2017, \\" any reduction in rate of tax any supply of goods or services or the benefit of input tax credit shall be passed on to the recipient by way of commensureate reduction of prices. Hence supplier/ manufacture to ensure to passe the benefit of reduced prices to UPPTCL. Further prices quoted by supplier/manufacturer is subject to scrutiny under above section.\\" 4- Evaluation of Tender shall be made after loading 18% GST (present rate) on all items including supply, erection, Testing & commissioning and civil work asuming the work as Work Contract. 5- SAMAST enebled Energy meter & communication equipments is to be supplied Place: Signature Name: Designation: Common Seal: Marked cell are required to filled by the bidders Tender Inviting Authority: Superintending Engineer, Electricity Substation Design Circle -I, U.P. Power Transmission Corporation Limited, 13th Floor, Shakti Bhawan Extension, 14-Ashok Marg, Lucknow-226001 Name of Work: Construction and commissioning of 02 no. 132kV GIS Feeder Bay (Outdoor) (For 132kV Sahjanwa TSS) at 220kV substation Dulhipar, Sant Kabir Nagar Tender Specification No. : SD-1046 Bidder Name : SCHEDULE- 2 (SCHEDULE OF QUANTITIES AND PRICES FOR Handling, Erection, Testing & Commissioning Charges) Sl. No. EQUIPMENT / ITEM(Complete with all fittings, accessories, associated equipments etc. as specified in Technical Specifications) Unit Quantity Unit Handling, Erection, Testing & Commissioning Charges (in Rs.) Total Prices without GST (in Rs.) (4x5) |
| 25 | Line Feeder Bay Module as per 220 KV S/S IS Comprising of circuit breaker, CTs & PTs, disconnectors, grounding switch, line disconnector, cable termination enclosure and local control cubicle. |
| 26 | 145kV, 1600A, 40KA for 3 sec SF6 gas insulated outdoor feeder bay module each comprising of SF6 gas insulated circuit breaker(1600A), current transformer (800/400/200/1-1-1A), bus-bar disconnectors with common grounding switch, line disconnector with one normal safety grounding switch, & one high speed fault make grounding switch, Local Control Cubicle, PT, SF6 gas monitoring system for complete bay. Three 1–phase SF6 ducts and gas insulated terminal connection for connecting 3 nos of single phase 630sq.mm XLPE cable with cable termination enclosure etc. and accessories to complete feeder bay module as per technical specification. |
| 27 | EREC of 132kV Line C&R Panel & Bus Bar Panel along with complete integration/Augmentation with existing Siemens make system in all respect (Integration of C&R Panel with existing SAS) |
| 28 | Optical fibre for SAS |
| 29 | 120 KV Surge Arresters (Polymer Type) |
| 30 | 145kV Potential Transformer |
| 31 | 145KV, 6KN Polymer BPI |
| 32 | 132kV Line Isolator as per technical specification |
| 33 | Erec of ABT Meter & Metering Cubicle in all respect |
| 34 | HT Cable & accessary |
| 35 | 145KV, 1core,630sqmm XLPE Copper Conductor Cable |
| 36 | 145 kV Termination Kit at both ends for I x 630 sq mm XLPE copper cable(one end is GIS type and other end is AIS type) |
| 37 | Outdoor Termination Kit suitable for 145kV, 1core, 630sq.mm. XLPE Copper Cable |
| 38 | Single core, 3.3kv 300 sqmm Sheath bonding coaxial cable |
| 39 | Single core, 500 sqmm Copper conductor PVC insulated 3.3 kv grade earthing cable |
| 40 | Single phase link box with/without SVL as required |
| 41 | Three phase link box with/without SVL as required |
| 42 | HDPE Pipe suitable for above XLPE Cable |
| 43 | Aluminium alloy single clamps |
| 44 | Aluminium alloy trefoil clamps |
| 45 | Terminal Connector as required |
| 46 | 1.1kV Grade PVC Aluminium conductor armoured power cables alongwith lugs, glands etc. |
| 47 | 2Cx6 sq.mm |
| 48 | 4Cx16 sq.mm |
| 49 | 1.1kV Grade PVC Copper conductor armoured control cables alongwith lugs, glands etc. |
| 50 | 2Cx2.5 sq.mm |
| 51 | 4Cx2.5 sq.mm |
| 52 | 6Cx4.0 sq.mm |
| 53 | 10Cx2.5 sq.mm |
| 54 | 14Cx2.5 sq.mm |
| 55 | 4Cx4 sq.mm |
| 56 | Installation of Complete Earthing System in all respect |
| 57 | Latice type Main & Auxiliary substation Structures with MS angles, channels, plates, nuts, bolts, Anchor bolts,step bolts, U bolts, spring washers, etc.,and any other required material |
| 58 | Installation of Hardware and Fittings in all respect along with Clamp, Conductor,Disc Insulators etc. Installation of type of PERFORATED TRAY for supporting control cables Total Note : 1- Any material not specifically mentioned in the above schedule but required for the proper and complete execution of the work shall be deemed to be included in the scope of work/erection. 2- Bidder is required to quote prices in this Schedule for all the individual items/sub-items. 3- Evaluation of Tender shall be made after loading 18% GST (present rate) on all items including supply, erection, Testing & commissioning and civil work asuming the work as Work Contract. 4- SAMAST enebled Energy meter & communication equipments is to be erected and commissioned. Place: Signature Name: Designation: Common Seal: Marked cell are required to filled by the bidders Tender Inviting Authority: Superintending Engineer, Electricity Substation Design Circle -I, U.P. Power Transmission Corporation Limited, 13th Floor, Shakti Bhawan Extension, 14-Ashok Marg, Lucknow-226001 Name of Work: Construction and commissioning of 02 no. 132kV GIS Feeder Bay (Outdoor) (For 132kV Sahjanwa TSS) at 220kV substation Dulhipar, Sant Kabir Nagar Tender Specification No. : SD-1046 Bidder Name : SUPPLY OF MANDATORY SPARES ( All Prices are in Rupees ) Sl. No. EQUIPMENT / ITEM(Complete with all fittings, accessories, associated equipments etc. as specified in Technical Specifications) Unit Quantity Quoted Unit prices in Rs. (Exclusive of GST) Total FOR Destination Prices without GST (4x8) Unit Ex-Works Prices Unit Pkg, Fwdg, Charges Unit Freight &Insurance charges Total unit rate without GST (5+6+7) |
| 59 | Outdoor Termination Kit suitable for 145kV, 1core, 630sq.mm. XLPE Copper Cable |
| 60 | Total Place: Signature Name: Designation: Common Seal: Marked cell are required to filled by the bidders Tender Inviting Authority: Superintending Engineer, Electricity Substation Design Circle -I, U.P. Power Transmission Corporation Limited, 13th Floor, Shakti Bhawan Extension, 14-Ashok Marg, Lucknow-226001 Name of Work: Construction and commissioning of 02 no. 132kV GIS Feeder Bay (Outdoor) (For 132kV Sahjanwa TSS) at 220kV substation Dulhipar, Sant Kabir Nagar Tender Specification No. : SD-1046 Bidder Name : SCHEDULE- 4 (SCHEDULE OF QUANTITIES AND PRICES FOR CIVIL WORKS) Item. No. Description of item Unit Tendered Qty. Unit Rate (in Rs) (Without GST) Total Prices Without GST (In Rs.) (4*5) |
| 61 | Earth work in surface excavation in all kinds of soil not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge (2.1.1) |
| 62 | Earth work in excavation all kinds of soil by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 SqM on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge.( 2.6.1) |
| 63 | Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.( 2.25(a)) |
| 64 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.(2.27 ) |
| 65 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared.(2.32 ) |
| 66 | Providing and laying in position cement concrete of 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) excluding the cost of centering and shuttering - All work up to plinth level.(4.1.8 ) |
| 67 | Providing and laying 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :(5.1.2 ) |
| 68 | Centering and shuttering including strutting, propping etc. and removal of form for (R.C.C) Foundations, footings, bases of columns, etc. for mass concrete, Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like( 5.9.1) |
| 69 | Centering and shuttering including strutting, propping etc. and removal of form for (R.C.C) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.(5.9.2) |
| 70 | Steel reinforcement for R.C.C. work Thermo-Mechanically Treated bars of grade Fe-500D or more including straightening, cutting, bending, placing in position and binding all complete upto plinth level.( 5.22.6) |
| 71 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand)( 6.1.1) |
| 72 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.(CSI No. 10.1) |
| 73 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.( 10.2) |
| 74 | Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. (11.2 ) |
| 75 | 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand) ( 13.4.1) |
| 76 | 12 mm Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. ( 13.9.1) |
| 77 | Neat cement punning. (13.18 ) |
| 78 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture(13.62.1 ) |
| 79 | Demolishing cement concrete manually Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.(15.2.1) |
| 80 | Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) (16.45 ) |
| 81 | Providing and laying C.C. pavement of mix M-20 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 Kg/CuM. Excess/less cement used as per design mix is payable/ recoverable separately). (CSI16.75-16.76) |
| 82 | Supplying and fixing C.I. cover without frame for manholes 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 Kg (19.18.2 ) |
| 83 | Supply of 28 mm. dia M.S. Anchor bolts (conforming to IS 266) 900 mm. long with base plate (75x75x6mm) welded with anchor bolts including its threading upto a length of 10cm. and also supply of a pair of galvanized standard nuts with threading including supply of 5 mm thick washer and cost of labour, material & T&P for proper completion of work. ( 29.13) |
| 84 | Fixing and grouting 28 mm and above dia bolts in proper alignment level and setout with help of a template complete including supply of all labour & T&P etc. required for proper completion of the work.(labour rates only) . ( 29.14) |
| 85 | Supply of 25 mm dia.M.S. Anchor bolts (conforming to IS-226) 500 mm long with base plate(50x50x6 mm)welded with anchor bolts,including its threading upto a length of 10cm. and galvanizing upto 15cm from top, also supply of a pair of galvanized standard nuts with threading including supply of 5mm thick washer and cost of labour material and T&P etc. required for proper completion of the work. (29.15 ) |
| 86 | Fixing and grouting 25 mm and below dia M.S. Anchor bolt in proper alignment level and setout with the help of a template including supply of all labour T&P etc. reqd. for proper completion of the work. (labour rates only) . (29.16 ) |
| 87 | S/F in position 105 lbs M.S. Rail for transformer plinth including cost of all labour, material and T&P etc. required for proper completion of the work. (29.20 ) |
| 88 | Fixing and grouting of trench edging in proper level and alignment including cost of all labour, and T&P etc. required for proper completion of the work but excluding cost of C.C. (labour rates only). ( 29.22) |
| 89 | Fixing of template in position level and alignment for grouting of Anchor bolt in main gantry (labour rate only). (29.23 ) |
| 90 | Fixing of template in position level and alignment for grouting of Anchor bolt in auxiliary structure. (labour rate only). |
| 91 | Fixing of cable trench racks in proper position and alignment including cost of all labour, material and T&Petc. required for proper completion of the work (Labour rate only). |
| 92 | Champering the edge of concrete in auxiliary structure, of size 25 mm wide in triangular section including all materials, labour & T&P etc complete. |
| 93 | 4.0 cm thick 1:1.5:3 plain cement concrete floor with cement, approved coarse sand & 2cm graded approved stone ballast laid in panels finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 as specified and removing any overlapping mortar at the joints of the panels if any and giving them a uniform finish including supply of all materials, labour and T&P etc, required for proper completion of the work. without base CC |
| 94 | Painting letters & number over cable trench cover or other places with the help of stencils including painting of base of 150 mm. dia of one coat of primer and two coats of superior quality synthetic enamel paint size of letter to be 60 mm. x 10 mm. including cost of all materials labour and T&P etc. required for proper completion of the work including placing of Trench covers in required position. Conditions: 1. All civil work shall be executed according to the approved drawings of UPPTCL. 2. The quantities in BOQ are tentative and may vary up to any extent or be deleted as per the requirement at site. 3. All civil work shall be carried out as per UPPWD/UPPTCL specification. 4. Rates in BOQ are exclusive of CGST,SGST. Labour tax shall be borne by contractor. 5. Pozzlona Portland cement confirming to IS 1489(Part 1) 1991 of approved quality like ACC,Ultra Tech,Birla or equi.shall only be used. 6. Overweight steel section within tolerance shall be measured at standard weight and underweight steel section within tolerence shall be measured at actual weight. 7. In case any change in Bill of Quantity is suggested by higher authority that will be binding on the contractor.The agreement shall be executed on the approved Bill of Quantity only. 8.Performance Guarantee shall be applicable as per GO 622/23-12-2012-2 Audit/08 dt 08 June 2012.adopted by UPPTCL BOD dated 27.06.2017 9. The 60% amount of bricks available from dismantling shall be reovered @ Rs. 2362.00/thousand + GST from firm /contractor. 10. The 30% amount of bricks available from dismantling shall be reovered as brick ballast @ Rs. 700.00/CuM + GST from firm /contractor. 11. The amount of steel/Chain link/Pale Fencing available from dismantling will be recovered Rs. 20.00/Kg + GST from firm /contractor. Signature Name: Designation: Common Seal: Marked cell are required to filled by the bidders |
AI Tender Summary
Tender Timeline
Sep 02, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 23, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender