Housing Urban and Rular Development Government Departments Closing in 6 days TDR #57320214

Tender For Construction Of Agriculture Office / Store And Residential Facility At Gurez

Issued by Government Departments · Bandipora, Jammu and Kashmir
Tender Value
2.81 Crore
Estimated cost
Bid Submission
22 Sep 2026
6 days left
EMD
5.63 Lakhs
Bank guarantee accepted
Document Fee
5500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bandipora → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Agriculture Office / Store And Residential Facility At Gurez

BOQ

Name of Work:- Construction of Agriculture office / Store and Residential Facility at Gurez
Sl. No. Item Description
1Agriculture Office/StoreEarth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres (ordinary rock) .
2P/L, of dry stone soling 75 mm nominal size duly hand packed with ramming, dressing, watering and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material.
3P/L, in position cement concrete of specified grade excluding the cost of centering & shuttering. All work up to floor V- level in 1:4:8 (1cement: 4 coarse, sand: 8 graded stone) aggregate of 40 mm Nominal size (nallah).Including carriage complete job.
4Providing and laying in position specified grade of reinforced cement concrete In 1:1.5:3 mix including curing but excluding the cost of centering, shuttering, finishing and reinforcement with 20 mm agg. all works upto plinth level.
5Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1.5:3 mix with 20 mm nominal stone agg.
6P/L, in position cement concrete of specified grade excluding the cost of centering & shuttering. All work up to plinth- level in 1:2:4 (1cement: 32coarse sand: 4 graded stone aggregate of 20 mm Nominal size .
7Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand).
8Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
9Carriage of materials by mechanical transport including loading, unloading and stacking complete.bricks from 160 km.
10Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns
11Suspended floors, roofs, landings, balconies and access platform.
12Lintel, Beam ,plinth beams,girders,bressumers and cantilevers.
13Reinforcement for R.C.C work incld straightening, cutting, bending, placing in position and binding all complete:- (Thermo Mechanically Treated Bars.)
14Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position with two coat of primer Kiln seasoned and chemically treated hollock wood complete job.
15Providing and fixing of ISI marked flush door shutters 35 mm decorative type core of block board construction and well matched teak 3 ply veeneering with vertical grains or cross bands and face veener on both sides of shutters with butt hinges and necessary accessories complete job.
16Providing and fixing of 35mm thick panelled & glazed shutters for windows & clerestory windows incl. cost of butt hingesKiln seasoned & chemically treated hollock wood.
17Providing and fixing if 35mm thick wire gauge shutters using galvanized MS wire gauge of average width for doors and windows incl.MS butt hinges & necessary beadings completeKiln seasoned & chemically treated hollock wood.
1812 mm Cement plaster of mix:1 : 6 ( 1 cement : 6 coarse sand).
19supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.
20Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 2 mm thick.
21Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: 13.57.1 Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter /10sqm.
22Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm)
23Painting with synthetic enamel paint on wood/Steel works with primer of approved brand and manufacture of required colour to give an even shade two or more coats 0n new work complete job.
24Providing and fixing 3.5mm thick glass panes of approved make including wooden beading of required size and section with necessary nails et. Complete.
25Structural Steel work welded in built up section, trusses and framed work in trusses,purlins,rafters,posts,post plates, angles channels or like components including cutting, hosting, fixing in position and applying a priming coat of approved steel primer complete.
26Providing and fixing hi-rib colour coated G.S sheet roofing 0.50mm thick fixed,self trapping screws with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm dia. With bitumen and G.I limpet washers or with G.I limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete( upto a pitch of 60 degree ) excluding the cost of purlins, rafters and trusses.
2750mm cement concrete flooring in 1:2:4 (1 cement: 2coarse sand: 4 graded stone agg., 20mm nominal size finished with a floating coat of neat cement slurry all inclusive leads, lifts, loading, un-loading, head load, cost and carriage of materials from approved nearest sources to site of work complete.
28Providing and fixing hardware fittings for doors and windows of approved brand and required shade and pattern complete.P/F premium and attractive strong durable door handle set with lock body and cylinder for main doors and internal doors,reversible latch,inside and outside opening door with colour of silver or black of godrej brand with all accessories.
29Door magnet stopper 4 inch stainless steel.
30Tower Bolt 150mm.
31Tower Bolt 100mm.
32Handle ornamental 600mm .
33Handle 100mm.
34Making Plinth protection 50mm thick of cement concrete 1:3:6 (1 cement:3 course sand:6 graded stone agg. 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand incl. finishing the top smooth.(nallah).incl.carriage complete job.
35Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of size 600mm x 1200 mm as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Incl. all carriage complete job.
36Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design incl. CI plate cover.
37Providing and laying Ceramic glazed anti skid floor tiles 600x600mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete
38Providing and fixing wash basin with pedestal making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm of jaquar,cera,hindware brand
39Providing and fixing cp wall mixer of jaquar,cera,hindware make.
40Providing and fixing CP Angle valve of 15mm dia with CP cap.jaquar, brand.
41Providing and fixing 20 mm ppr Pipe with all fittings & fixtures.
42Providing and fixing PVC pipe 3\\" with all fixtures.
43Providing and fixing PVC pipe 4\\" with all fixtures.
44Providing and fixing CP W.B mixture of jaquar cera,hindware make and shape.
45Providing and fixing 50 Lts Geyser of approved quality or venus,hindware,jaquar.
46Providing and fixing S.S square 6\\"x6\\" push to open floor gating,anti foul of approved brand CP jali.
47Providing and fixing mirror of superior glass of 5mm thick.
48Providing and fixing of cp connection 600mm.
49Providing and fixing of waste pipe.
50Providing and fixing of Towel rod 600 mm jaquar cera,hindware.
51Providing and fixing of Health fauset of approved brand jaquar cera,hindware.
52Providing and fixing white China ware one piece western european type W.C of ceramic material of specified size with dual flushing cistern of capacity 10 ltr and PVC flush pipe etc with soft close seat cover slow motion seat cover of size 64.5cmx36cmx75cm with s-trap 110mm and good to walls and floor all complete job of brand Jaquar cera,hindware.
53Providing and fixing of pvc water storage tank of approved quality.complete job.
54Dry random rubble masonry with hard stone in foundation and plinth incuding cost and carraige of stones complete job.
55Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) :
56Providing and fixing of wardrobe in walls of 600mm deep and 19 mm thick plywood, teak wood , sun mica ,white liner,drawer and all necessary item/accessories handle,lock complete job.
57Stone tile work for wall lining upto 10m height with special adhesive like araldite or equivalent over 12mm thick bed of cement mortar 1: 3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade 8mm thick (mirror polished and machine cut edges).
58Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel posts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered including fixing accessories such as master pillar,nuts, bolts, fasteners etc.).
59Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete job size--600x600mm.
60Providing and fixing of readymade wooden panelling t&g imported inclusive of polish , framework with 12mm ply incl. cornice 2\\" complete job.
61Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
62Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin- charge. (Cost of aluminum snap beading shall be paid in basic item.)With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm) including frame work, handels ,door closer all aluminium hardware fittings complete job.
63Providing and fixing gang saw cut, mirror polished, premoulded and prepolished,machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels,Granite of any colour or shade Area of slab over 0.5 sqm) 18mm thick.
64Carriage of materials by mechanical transport including loading, unloading and stacking complete.Aggregates from avg.lead of 115 km.
65Sand from avg.lead of 10 km.
66Residential FacilityEarth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres (ordinary rock) .
67P/L, of dry stone soling 75 mm nominal size duly hand packed with ramming, dressing, watering and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material.
68P/L, in position cement concrete of specified grade excluding the cost of centering & shuttering. All work up to floor V- level in 1:4:8 (1cement: 4 coarse, sand: 8 graded stone) aggregate of 40 mm Nominal size (nallah).complete job.
69Providing and laying in position reinforced cement of specified grade of concrete including curing but excluding the cost of centering and shuttering, finishing and reinforcement. All works upto plinth level with :1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size).
70Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1.5:3 mix with 20 mm nominal stone agg.
71P/L, in position cement concrete of specified grade excluding the cost of centering & shuttering. All work up to plinth- level in 1:2:4 (1cement: 32coarse sand: 4 graded stone aggregate of 20 mm Nominal size .
72Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:6 ( 1 cement : 6 coarse sand).
73Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
74Carriage of materials by mechanical transport including loading, unloading and stacking complete.bricks from 160 km.
75Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases for columns
76Suspended floors, roofs, landings, balconies and access platform.,Beams.
77Reinforcement for R.C.C work incld straightening, cutting, bending, placing in position and binding all complete:- (Thermo Mechanically Treated Bars.)
78Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position with two coat of primer Kiln seasoned and chemically treated hollock wood complete job.
79Providing and fixing of ISI marked flush door shutters 35 mm decorative type core of block board construction and well matched teak 3 ply veeneering with vertical grains or cross bands and face veener on both sides of shutters with butt hinges and necessary accessories complete job.
80Providing and fixing of 35mm thick panelled & glazed shutters for windows & clerestory windows incl. cost of butt hingesKiln seasoned & chemically treated hollock wood.
81Providing and fixing if 35mm thick wire gauge shutters using galvanized MS wire gauge of average width for doors and windows incl.MS butt hinges & necessary beadings completeKiln seasoned & chemically treated hollock wood.
8212 mm Cement plaster of mix:1 : 6 ( 1 cement : 6 coarse sand).
83supplying and filling in plinth with fine sand under floors including, watering, ramming, consolidating and dressing complete.
84Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 2 mm thick.
85Finishing with Deluxe multi surface paint system for interiors and exteriors using primer as per manufacturers’ specifications: 13.57.1 Two or more coats applied @ 1.25 liter/10sqm over and including one coat of special primer applied @ 0.75liter /10sqm.
86Painting with synthetic enamel paint on wood/Steel works with primer of approved brand and manufacture of required colour to give an even shade two or more coats 0n new work complete job.
87Providing and fixing 3.5mm thick glass panes of approved make including wooden beading of required size and section with necessary nails et. Complete.
88Structural Steel work welded in built up section, trusses and framed work in trusses,purlins,rafters,posts,post plates, angles channels or like components including cutting, hosting, fixing in position and applying a priming coat of approved steel primer complete.
89Providing and fixing hi-rib colour coated G.S sheet roofing 0.50mm thick fixed,self trapping screws with EPDM seal or with polymer coated J or L hooks, bolts and nuts 8mm dia. With bitumen and G.I limpet washers or with G.I limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete( upto a pitch of 60 degree ) excluding the cost of purlins, rafters and trusses.
9050mm cement concrete flooring in 1:2:4 (1 cement: 2coarse sand: 4 graded stone agg., 20mm nominal size finished with a floating coat of neat cement slurry all inclusive leads, lifts, loading, un-loading, head load, cost and carriage of materials from approved nearest sources to site of work complete.
91Providing and fixing hardware fittings for doors and windows of approved brand and required shade and pattern complete.P/F premium and attractive strong durable door handle set with lock body and cylinder for main doors and internal doors,reversible latch,inside and outside opening door with colour of silver or black of godrej brand with all accessories.
92Door magnet stopper 4 inch stainless steel.
93Tower Bolt 150mm.
94Tower Bolt 100mm.
95Handle ornamental 600mm .
96Handle 300mm ornamental.
97Making Plinth protection 50mm thick of cement concrete 1:3:6 (1 cement:3 course sand:6 graded stone agg. 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand incl. finishing the top smooth.(nallah).incl.carriage complete job.
98Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of size 600mm x 1200 mm as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Incl. all carriage complete job.
99Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design incl. CI plate cover.
100Providing and laying Ceramic glazed anti skid floor tiles 600x600mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete
101Providing and fixing wash basin with pedestal making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm of jaquar,cera,hindware brand
102Providing and fixing cp wall mixer 3 in 1 of jaquar,cera,hindware make.
103Providing and fixing CP Angle valve of 15mm dia with CP cap.jaquar, brand.
104Providing and fixing 12\\"x12\\" square ultra slim shower head with 18\\" square arm CP shower of jaquar make and shape.
105Providing and fixing 20 mm ppr Pipe with all fittings & fixtures.
106Providing and fixing PVC pipe 3\\" with all fixtures.
107Providing and fixing PVC pipe 4\\" with all fixtures.
108Providing and fixing CP W.B mixture of jaquar cera,hindware make and shape.
109Providing and fixing 50 Lts Geyser of approved quality or venus,hindware,jaquar.
110Providing and fixing S.S square 6\\"x6\\" push to open floor gating,anti foul of approved brand CP jali.
111Providing and fixing mirror of superior glass of 5mm thick.
112Providing and fixing of cp connection 600mm.
113Providing and fixing of waste pipe.
114Providing and fixing of Towel rod 600 mm jaquar cera,hindware.
115Providing and fixing of Health fauset of approved brand jaquar cera,hindware.
116Providing and fixing white China ware one piece western european type W.C of ceramic material of specified size with dual flushing cistern of capacity 10 ltr and PVC flush pipe etc with soft close seat cover slow motion seat cover of size 64.5cmx36cmx75cm with s-trap 110mm and good to walls and floor all complete job of brand Jaquar cera,hindware.
117Providing and fixing of pvc water storage tank of approved quality.complete job.
118Dry random rubble masonry with hard stone in foundation and plinth incuding cost and carraige of stones complete job.
119Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) :
120Providing and fixing of wardrobe in walls of 600mm deep and 19 mm thick plywood, teak wood , sun mica ,white liner,drawer and all necessary item/accessories handle,lock complete job.
121Stone tile work for wall lining upto 10m height with special adhesive like araldite or equivalent over 12mm thick bed of cement mortar 1: 3 (1 cement : 3 coarse sand) including pointing in white cement with an admixture of pigment to match the stone shade 8mm thick (mirror polished and machine cut edges).
122Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel posts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered including fixing accessories such as master pillar,nuts, bolts, fasteners etc.).
123Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete job size--600x600mm.
124Providing and fixing of readymade wooden panelling t&g imported inclusive of polish , framework with 12mm ply incl. cornice 2\\" complete job.
125Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer.
126Providing and fixing 25mm dia stainless steel curtain rod with side brackets and curtain rod holder fix on windows and doors complete job.
127Providing and fixing 2'x2' sink of approved make.
128Providing and fixing cp sink mixer of cera,jaquar,hindware make .
129providing and fixing 50mm thick precast cement concrete tiles in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing, cleaning and curing complete, on 50 mm thick bed and sand cushioning with cement concrete 1:3:6 complete job.
130Providing and fixing gang saw cut, mirror polished, premoulded and prepolished,machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels,Granite of any colour or shade Area of slab over 0.5 sqm) 18mm thick.
131Providing and fixing 12mm thick ply including frame work of KD wood with wooden decorative sunmica laminates of superior quality and durability of 1mm on both sides of ply with 2\\" cornice including nails,scaffolding charges and other neccesary accessories complete job.
132Providing and fixing wooden kitchen cabinets with box drawer, white liner,handles all accessories complete job.
133Providing and fixing 5mm thick glass panes of approved make including wooden beading of required size and section with necessary nails etc. Complete.
134Supply and stacking of good earth at site including royality earth measured in stacks including leads lifts carraige complete job.
135Spreading of sludge dump manure or good earth in reqd thickness .
136Mixing earth and sludge or manure in proportion specified.
137Grassing with selection no. grass including watering and maintanence of the lawn for 30 days or more till the grass forms a thick lawn free from weeds .
138Providing and fixing planed weather boarding 25mm thick of approved design with overlapping, rounding of edges,beading and frame work of required size and carraige complete job.(budloo wood)
139Carriage of materials by mechanical transport including loading, unloading and stacking complete.Aggregates below 40mm from avg.lead of 115 km.
140Sand from avg.lead of 10 km.
141Electrification for Agriculture office/storeWiring for Light point/Fan point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells Lifeguard/Anchor fireguard/Polycab Green/Eq Make) in surface/recessed Conduits laid in slabs (Including Cost of Conduit 25mm) with 01 No. of 6 Amp Modular Switch, Modular Plate/Cover in front & suitable GI box etc. IS0/IEC Certified/Schneider Zencelo/Havells Crab tree/Legrand Arteor/Anchor roma plus/ABB Tvisha/Eq.Make & along with 2.5 Sqmm (P+N+E) Circuit Wire of same make as mentioned above & items shall be approved before execution of work by SDO.
142Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/Anchor fireguard/Polycab Green/Eq Make)
143Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified of Schneider Zencelo/Havells Crab tree/Legrand Arteor/Anchor roma plus/ABB Tvisha/Eq.Make & shall be approved before execution of work by SDO
144Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/Anchor fireguard/Polycab Green/Eq Make)
145Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified of Schneider Zencelo/Havells Crab tree/Legrand Arteor/Anchor roma plus/ABB Tvisha/Eq.Make & shall be approved before execution of work.
146Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells Lifeguard/Anchor fireguard/Polycab Green/Eq Make) & shall be approved before execution of work (Including Cost of Conduit/Channel).2 X 10 sq.mm + 1 X 6 sq.mm earth wire.
1472 X 6 sq.mm + 1 X 6 sq.mm earth wire.
1482 X 4 sq.mm + 1 X 4 sq.mm earth wire
1492 X 2.5 sq.mm + 1 X 2.5 sq.mm earth wire
150Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections. (L&T/Siemens/Legrand/Havells/ABB/Eq. Make)
151Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C* Curve 10K, Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens/Legrand/Havells/ABB/Eq Make)63Amp.
15240Amp.
15332Amp.
154Supplying and Fixing of MCB way 6-way (4 + 18), horizontal typed, sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/Schneider/ABB/Eq Make)
155Supply/Installation/Testing and Commissioning of 18W + LED Conceal/Surface (Commercial Type) light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95, THD<10%, CCT 5700K, CRI >80. The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 150V to 270V. The Fixture should have In-built Surge Protection of 2kV Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Philips/Havells/Wipro/Halonix/Eq Make
156Providing & Fixing of IP-66 protected high power LED 50 Watt flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses to achieve various beam angles, of high power LED of 3 to 5 watt each. Integrated potted driver & a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/wt. LED driver Input Voltage AC 120 to 270 VAC with High voltage Cutoff @ 300 VAC and Auto resetting Safety Power Factor >0.95, THD(i) <10%, driver current <=750mA. Driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector, Surge Protection Min 10KV internal and LOR external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI N70 and CCT 5700K/385K. Manufacturers Word Mark Name Engraved/Embossing/Screen printing on die cast housing to allow traceability authenticity. Fixture shall be IS 10322 C complianced OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures (LM79/LM80) Certificate/report with lab warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure “A” attached with this BSR. High Power LED Flood Light Minimum lumen output 6200 lm of Havells/Crompton/Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt. The job further includes replacement warranty of fixture (if damaged/burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning/handing over of site to intending department.
157Supply/Installation/Testing and Commissioning of 225-250mm Shutter Type, 320 Cu.m/Hr. AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection etc. USHA/Havells/Crompton/Eq. Make. (Min 1-Star)
158Supply/Laying/Connecting and Commissioning of 50 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq. Make with required size of thimbles duly crimped with hydraulic crimping tool including Providing/Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench. (Material to be approved before execution)
159Supply, Installation Testing and Commissioning of CPRI Approved (IS/IEC:61439) Main Controlling Panel, fabricated out of heavy gauge sheet steel, duly painted with powder coated paint, dust protected earth terminal fitted on epoxy cleats, volt meter & ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified. The switch are adjustable type made of Havells/L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/L&T/Legrand/Schneider Make. 1) Normal Incomer: (a) 125 Amp-4-Pole 35kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand/Schneider Make as approved-01 No. (b) 200 Amps TPN Al Bus Bar Set = 01 Set. Digital Voltmeter, Ammeter, CT Coils with Selector Switch & Phase indicator Set. 125 Amp. 4-pole changeover to switch between main supply and generator supply. Outgoing: (1) Normal outgoing for Heating AC Lighting Inverter etc load (a) 63-Amp DP MCB = 02 No. for Heating Sub-main (b) 40-Amp DP MCB = 02 No. for Lighting Machine Sub-main (c) 32-Amp DP MCB = 02 No. for inverter Sub-main and AC Sub main
160ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value. Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man-hole cover for the above. Including cost of 20MM Wide copper strip as required in one run fitted with brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Polyethylene Pipe having Corrugation complete job
161Supply Installation/Testing/Commissioning of Inverter 2KVA/24V Pure Sinewave Inverter. Intelligent Load Sharing & BIS Certified (with 2-Year Warranty), 02 No. of 200Ah,12V Tubular battery (with 60 Months Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery etc /Luminious/EXIDE/AMRON/Eq. Make
162Supply and fixing of PVC ceiling rose (2/3 pin), ISI marked, suitable for connection of light/fan point, complete with necessary accessories, including connections and testing as required of Havells/Anchor/Legrand/Eq.make
163Supply and fixing of Hylum sheet (phenolic laminated sheet), 3 mm / 6 mm / 10 mm thick (as specified), duly cut to required size and shape, fixed with necessary nuts, bolts, screws, washers, spacers etc., including finishing and making good the surface, complete as required
164Supply installation testing, & commissioning of 20 KVA 3-Phase SERVO controlled VOLTAGE Stabilizer of Approved brand with following SPECIFICATIONS: (1) INPUT VOLTAGE: 156 Volt -450 Volts P-P (90V-260V N-P) (2) OUT PUT VOLTAGE: 400Volts + 1% (230VAC) (3) Winding Material Insulation: 99.97% PURE COPPER WOUND FIBER GLASS (4) IN DOOR TYPE (5) COOLING: OIL IS 335 (6) MICRO CONTROLLED TRUE RMS Based LCD display (7) Protections are Over Load. COPPER wound of Electric Field /Alba /AE /Cosco/Eq.make etc ISI/ISO certified for smooth functioning/constant voltage supply having Technical Specifications: Input voltage=90-260 volts & output voltage=220 volts +/- 2%. Buck Boost Transformer Copper wound 99.9%, OIL Immersed COOLING OIL, High cut/Low Cut/Time delay/Over Cut through Micro Control and Spike Protection including, Carriages, installation charges, testing & taxes complete job alongwith servo bypass switch of adequate rating.
165Supply/Installation/Testing and Commissioning of 125 Amp Four Pole manual bypass changeover switch of Havells/Siemens/ABB/Schinder/L&T/Eq make to switch between Generator Supply and Main Supply.
166Electrification for Agriculture Residential facilityWiring for Light point/Fan point/Exhaust fan/Bell point with (P+N+E) 3x1.5 sq.mm FRLS-H PVC insulated Multi strand Copper conductor single core cable, (Havells Lifeguard/Anchor fireguard/Polycab Green/Eq Make) in surface/recessed Conduits laid in slabs (Including Cost of Conduit 25mm) with 01 No of 6 Amp Modular Switch, Modular 2 Plate, Cover in front & suitable GI box etc ISO/IEC Certified/Schneider Zencelo/Havells Crab tree/Legrand Arteor/Anchor roma plus/ABB Tvisha/Eq.Make & along with 2.5 Sqmm (P+N+E) Circuit Wire of same make as mentioned above & items shall be approved before execution of work by SDO.
167Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/Anchor fireguard/Polycab Green/Eq Make)
168Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc as required. ISO/IEC Certified of Schneider Zencelo/Havells Crab tree/Legrand Arteor/Anchor roma plus/ABB Tvisha/Eq.Make & shall be approved before execution of work by SDO.
169Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Havells Lifeguard/Anchor fireguard/Polycab Green/Eq Make)
170Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). ISO/IEC Certified of Schneider Zencelo/Havells Crab tree/Legrand Arteor/Anchor roma plus/ABB Tvisha/Eq.Make & shall be approved before execution of work.
171Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Havells Lifeguard/Anchor fireguard/Polycab Green/Eq Make) & shall be approved before execution of work (Including Cost of Conduit/Channel).2 X 10 sq mm + 1 X 6 sq. mm earth wire
1722 X 6 sq mm + 1 X 6 sq. mm earth wire
1732 X 4 sq mm + 1 X 4 sq. mm earth wire
1742 X 2.5 sq mm + 1 X 2.5 sq. mm earth wire
175Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP.240v, C*C Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB DB Complete with connections.(L&T/Siemens/Legrand/Havells/ABB/Eq. Make)
176Supply/Fixing/Testing and Commissioning of following rating, Double pole, (P+N) 240 V, C*C Curve 10K, Miniature Circuit Breaker (MCB) in the existing MCB DB complete with connections. (L&T/Siemens/Legrand/Havells/ABB/Eq Make)63 Amp.
17740 Amp.
17832 Amp.
179Supplying and Fixing of MCB way 8-way (4 + 24), horizontal typed, sheet steel, Double Door Distribution Board, TPN 240V/415 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/Schneider/ABB/Eq Make).
180Supply/Installation/Testing and Commissioning of 18W + LED Conceal/Surface (Commercial Type) light luminary fitting round shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 THD<10%, CCT 5700K, CRI 80. The LED with Useful life of 50000 Hrs at L70. The Input voltage range shall be 150V to 270V. The Fixture should have In-built Surge Protection of 2kV. Certification - LM79 & LM80 test report should be from govt approved In-house NABL lab/government of India authorised lab. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years, which includes replacement of fixtures of Philips/Havell's/Wipro/Halonix/Eq Make.
181Providing & Fixing of IK08 IP-66 protected high power LED 50 Watt flood light system with single piece Pressure die cast aluminium housing, toughened glass diffuser with suitable lePnses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each Integrated potted driver as a unique BIS R number having efficiency more than 85% and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/w; LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff (a >= 300 V AC and Auto reseting Safety Power Factor -0.95, THD(i) <10%, driver current <750mA, driver should be Phase to phase protection of 440 V for 4 Hrs Electrical Connector, Surge Protection Min >=4KV internal and 10KV external but inside driver compartment. System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K 355K. Manufacturer's Word Mark/Name Engraved Embossing Screen printing on die cast housing to allow traceability authenticity. Fixture shall be IS 10322 Complianced OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products work, refer Annexure “A” attached with this BSR - High Power LED Flood Light Minimum lumen output 6200 lm of Havells Crompton Philips Make as approved and to be installed on outside block including S/F of suitable size of Gyser bolt. The job further includes replacement warranty of fixture (if damaged burnt out what so ever reason) for a period of two years reckoned from date of successful commissioning handing over of site to intending department
182Supply/Installation/Testing and Commissioning of 225-250mm Shutter Typed, 320 Cu.m/Hr AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB of Following Sizes including connection etc USHA/Havells/Crompton/Eq. Make. (Min 1-Star)
183Supply/Laying/Connecting and Commissioning of 70 sq.mm 3.5-Core XLPE/PVC insulated and steel armored 1.1 KV grade Aluminum Cable of Havells/Polycab/Eq. Make with required size of thimbles dully crimped with hydraulic crimping tool including Providing Fixing of saddles/clips with making of connection and partially to be laid underground through DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refilling the Trench (Material to be approved before execution)
184Supply Installation/Testing and Commissioning of CPRI Approved (IS/IEC 61439) Main Controlling Panel, fabricated out of heavy gauge sheet steel, dully Painted with powder coated paint, dust protected, earth terminal fitted on epoxy cleats, volt meter & Ammeters with selector switch & CT Coil of required ratio with all necessary connections & inner wiring of panel on both heating and lighting circuits. The switches are connected with bus bars inside panel & manufacturer CPRI Certified. The switch are adjustable type made of Havells/L&T/ABB/Legrand/Siemens Make and change over switch should be of Havells/L&T/Legrand/Schneider Make.(1) Normal Incomer:a) 160 Amp-4-Pole .35kA C-CURVE MCCB with extended terminals Havells/L&T/Legrand Schneider Make as approved — 01 No.b) 300 Amps TPN Al Bus Bar Set = 01 Set, Digital Voltmeter Ammeter, C.T Coils with Selector Switch & Phase indicator Set160 Amp 4-pole changeover to switch between main supply and generator supplyOutgoing:(1) Normal outgoing for Heating AC Lighting Inverter etc load(a) 63-Amp DP MCB — 02 No. for Heating Sub-main(b) 40-Amp DP MCB — 02 No. for Lighting Machine Sub-main(c) 32-Amp DP MCB — 02 No. for inverter Sub-main
185ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER Rod EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value. Supplying, Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man-hole cover for the above, Including cost of 20MM Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through DWC High Density Poly ethylene Pipe having Corrugation complete job
186Supply and fixing of PVC ceiling rose (2/3 pin), ISI marked, suitable for connection of light/fan point, complete with necessary accessories, including connections and testing as required of Havells/Anchor/Legrand/Eq.make
187Supply and fixing of Hylum sheet (phenolic laminated sheet), 3 mm / 6 mm / 10 mm thick (as specified), duly cut to required size and shape, fixed with necessary nuts, bolts, screws, washers, spacers etc., including finishing and making good the surface. complete as required
188Supply/Installation/Testing/Commissioning of Inverter 2KVA/24V Pure Sinewave Inverter, Intelligent Load Sharing & BIS Certified (with 2-Year Warranty), 02 No. of 200Ah,12V Tubular battery (with 60 Months Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery etc /Luminous/EXIDE/AMRON/ Eq. Make Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 57320214
AUTHORITY Government Departments
TENDER VALUE 2.81 Crore
LAST DATE 22-09-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Agriculture Office / Store And Residential Facility At Gurez
Basic Detail
Tender No E-NIT No 45 of 2026-27 EE-RnB-Grz-5768-75 E-tendering Dated-02-09-2026
Bidding Type Tender
Location
City Bandipora
State Jammu and Kashmir
Key Dates
Publish Date 03 Sep 2026
Submission Date 22 Sep 2026
Open Date 24 Sep 2026
Finance
Tender Value 2.81 Crore
Tender Fee 5500
EMD 5.63 Lakhs
Exemption Not Available
Document List
06fe0ce8-1019-4293-a5a3-4738956679c9.html
BOQ_1087521.xls
Tendernotice_1 (14).pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 03, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Sep 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
html

06fe0ce8-1019-4293-a5a3-4738956679c9.html

xls

BOQ_1087521.xls

pdf

Tendernotice_1 (14).pdf

pdf

Tendernotice_2.pdf

Disclaimer